ENGINEERING DEPT. REVISIONS ECN12049-0 PRODUCT SPECIFICATION For ST Optic Connector and Adaptor SPEC.NO.: SPSTP01B PAGE: 1/5 1. SCOPE: This specification contains the test requirement of subject connectors when tested under the condition or procedure defined in applicable standards use in single mode or multimode fiber optical cable assembly for ST/PC patch cord and/or pigtail 2. APPLICABLE STANDARDS: TIA/EIA-568-B.3 Optical Fiber Cabling Components Standard JIS C5978 F09 Type connectors for optical fibre cables IEC 61754-2 Fibre optic connector interfaces – Type BFOC/2,5 connector family GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies 3. APPLICABLE SERIES NO: For ST Optic Connector and Adaptor 4. SHAPE, CONSTRUCTION AND DIMENSIONS See APPENDIX 5. MATERIALS 5.1 Connector Ferrule: Housing Boot: Flange: Dust Cap: 5.2 Adaptor Sleeve Holder: Housing Washer: Nut: Dust Cap: Sleeve: Zirconia Zinc Alloy/Ni-Plating PP+TPR C3604 PE C3604 Zinc Alloy/Ni-Plating C3604 Zinc Alloy/Ni-Plating Silicone ZrO2 for S.M. and PhBr for M.M. 6. Optical Characteristics 6.1 Maximum insertion loss 6.2 Optical return loss : 0.2dB(SM)/0.3dB(MM) : ≤ -25dB for MM/PC ≤ -45dB for SM/PC ≤ -50dB for SM/UPC CVILUX CORP 2012.05.07 ISSUED REVIEWED : David APPROVED : Eisley VERIFIED : Erin . ENGINEERING DEPT. REVISIONS ECN12049-0 PRODUCT SPECIFICATION For ST Optic Connector and Adaptor SPEC.NO.: SPSTP01B PAGE: 2/5 7. MECHANICAL PERFORMANCE: (Base on TIA/EIA-568-B.3) The appearance of DUT should be No Significant Damage after test ITEM 7.1 7.2 7.3 7.4 7.5 TEST CONDITION Height: 1.8M REQUIREMENT Insertion Loss ≤ 0.5dB No. of Impact: 8 drops Change ≤ 0.2dB Strength of coupling mechanism 33N at 0-degree pull angle Insertion Loss ≤ 0.5dB Duration: 5 seconds Change ≤ 0.2dB Durability Mating cycles: 500 times Test record taken at: 50,100,250,500 Tensile Load: 50N (With strength members) 2.2N (Without strength members) at 0°, 90° Duration: more than 5 sec Tensile Load: 50N (With strength members) 2.2N (Without strength members) Insertion Loss ≤ 0.5dB Impact Cable retention Flex Change ≤ 0.2dB Insertion Loss ≤ 0.5dB Change ≤ 0.2dB Insertion Loss ≤ 0.5dB Change ≤ 0.2dB Angle: 0°~+90°~0°~-90°~0° Cycle: 100 7.6 Twist Tensile Load: 15N (With strength members) 2.2N (Without strength members) Insertion Loss ≤ 0.5dB Change ≤ 0.2dB Rotate: 2.5rev.~-5rev.~+2.5rev. Cycle: 9 Remark: Wavelength 1.31μm . Insertion Loss Change shows Insertion Loss difference between before and after test. ENGINEERING DEPT. REVISIONS ECN12049-0 PRODUCT SPECIFICATION For ST Optic Connector and Adaptor SPEC.NO.: SPSTP01B PAGE: 3/5 8. ENVIRONMENTAL PERFORMANCE: (Base on TIA/EIA-568-B.3) The appearance of DUT should be No Significant Damage after test 8.1 8.2 8.3 ITEM Low Temperature Temperature Life Humidity TEST CONDITION Temperature: 0°C Measurement require during test Duration: 96Hrs(4days) Temperature: 60°C Duration: 96Hrs(4days) Temp.:40±2℃ Humidity: 90~95% Measurement require during test Duration: 96Hrs(4days) REQUIREMENT Insertion Loss ≤ 0.5dB Change ≤ 0.2dB Insertion Loss ≤ 0.5dB Change ≤ 0.2dB Insertion Loss ≤ 0.5dB Change ≤ 0.2dB Remark: Wavelength 1.31μm . Insertion Loss Change shows Insertion Loss difference between before and after test. 9. TEMPERATURE AND HUMIDITY RANGE 9.1 Storage temperature: -40 to + 85°C 9.2 Operating temperature: -40 to + 75°C 9.3 Humidity (Non-condensing): 0~95% R.H. ENGINEERING DEPT. REVISIONS ECN12049-0 PRODUCT SPECIFICATION For ST Optic Connector and Adaptor SPEC.NO.: SPSTP01B PAGE: 4/5 Appendix: Spec Drawings For Simplex ST/PC Plug Reference A B C D E G J P Note: Dome eccentricity of the spherical polished endface shall be less than 50μm Dimensions Minimum Maximum 2.4985mm 2.4995mm 5.25mm 5.46mm 0.91mm 1.07mm 7.06mm 7.24mm 7.75mm 8.00mm 0.58mm 0.76mm 9.4mm 9.8mm 1.6mm 3.2mm ENGINEERING DEPT. REVISIONS ECN12049-0 PRODUCT SPECIFICATION For ST Optic Connector and Adaptor SPEC.NO.: SPSTP01B PAGE: 5/5 For Simplex ST/PC Adaptor Reference B C D E F H J M Dimensions Minimum Maximum 5.49mm 5.82mm 1.12mm 1.47mm 6.86mm 7.04mm 6.99mm 7.62mm 4.8mm 5.56mm 1.07mm 1.57mm 2.501mm 2.84mm 2.36mm 3.53mm