Preview only show first 10 pages with watermark. For full document please download

Reznor Pap Tech Data

   EMBED


Share

Transcript

Page __________ of __________ ® Model UDAP Power Vented, Low Static Axial Fan Unit Heaters for Residential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada C T CQS P M NT Y UA E RO LITY SYST A DU CT WARR Q CUS MER TO CSA 2.6b P C Y ROC EN E R G ES V EN ON START-UP G ● ● ● ● ● ● S A STANDARD FEATURES ANSI Z83.8b DESCRIPTION Reznor® Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input. Sizes 30-125 are approved for residential application. All sizes are approved for commercial/industrial installations. Model UDAP heaters are designed for 82-83% thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association (CSA). Series unit heaters have a refreshing new Reznor® appearance with a glossy white cabinet finish and less visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or, an optional hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the cabinet makes connecting control wiring easy with no panels to remove. The addition of a “G” terminal to the strip, along with the new design of the circuit board, allows for fan only operation (without adding relays). All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the TCORE2 ® heat exchanger and single burner combustion system. Other standard features include a single-stage gas valve, multi-try direct spark ignition with 100% lockout, pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly, and a high temperature limit control. Sizes 30-125 also include a flame rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The new Series unit heaters are designed to provide all the features you expect in a Reznor heater plus improved efficiency, easier installation, and a new look ~ both inside and out. ● ● ● ● ● ● ● ● ● ● ● ● ● Sizes 30-125 certified for residential heating application Sizes 30-400 certified for commercial/industrial heating application 82-83% Thermal efficient ~ TOP in its class! 50-60°F Rise range NEW TCORE2 ® titanium stabilized aluminized steel heat exchanger NEW patented** TCORE2 ® single burner combustion system including a onepiece burner assembly 115/1/60 Supply voltage 115 Volt open fan motor with internal overload protection Transformer for 24-volt controls Integrated circuit board with diagnostic indicator lights Multi-try direct spark ignition with 100% lockout Fan relay (included on the circuit board) Single-stage natural gas valve (field adjustable for operation to 9,000 ft elevation) Vibration/noise isolated fan and venter motors ~ designed for low noise operation 2-pt and 4-pt Suspension ~ standard on all sizes External terminal strip for 24-volt wiring External gas connection Full fan guard ~ engineered for safety Improved cabinet design with less visible hardware and a NEW Reznor appearance OPTIONAL FEATURES - FACTORY INSTALLED ● Single-stage, propane gas valve (field adjustable for operation to 9,000 ft elevation) ● Two-stage natural gas or propane gas valve - Sizes 60-400 ● 409 or 316 Stainless steel heat exchangers ● 208 or 230 Single phase voltage ● Totally enclosed fan motor (Sizes 30-250, 115V only) ● Common venting with other gravity vented Category I appliance(s) (Sizes 30-100) ACCESSORIES - FIELD INSTALLED ● ● ● ● ● ● ● ● ● ● ● Vent cap Thermostat Thermostat guard with locking cover Vertical louvers ~ new design Downturn nozzle kits ~ new design Gas conversion kits (natural and propane) Master/Slave controls for zoning up to six units Ceiling suspension kit - Sizes 30-125 Hanger kits for 1” pipe Stepdown transformer (for 230/3 and 460/3 supply voltage) Manual shutoff valves ** U.S. Patent No. 6,889,686 Form RZ-NA-C-UH Page 6 Page __________ of __________ MODEL UDAP TECHNICAL DATA - Sizes 30 - 125 Size BTUH kw/h Input Heating Capacity Thermal Efficiency (%) BTUH kw/h Natural B Gas Connection (inches) Propane C Vent Connection Size (inches diameter) Control Amps (24 volt) Full Load Amps (115 volt) D Maximum Over Current Protection (115V) Normal Power Consumption (watts) Discharge Air Temperature Rise (°F) CFM Air Volume 3 M /minute 2 ft Discharge Air Opening Area 2 M FPM Output Velocity M/minute Open E Fan Motor HP Enclosed Fan Motor RPM Fan Diameter (inches) Sound Level dba @ 15 ft lbs Approximate Net Weight kg lbs Approximate Ship Weight kg Output Heating Capacity A 30 45 60 75 100 125 30,000 8.8 82 24,600 7.2 1/2 1/2 4 1.0 1.9 15 109 50 456 12.9 0.96 0.09 475 145 0.02 0.06 1550 10 40 54 24 61 27 45,000 13.2 83 37,350 11.0 1/2 1/2 4 1.0 2.4 15 155 55 629 17.8 0.96 0.09 656 200 0.03 0.06 1550 10 40 59 27 66 30 60,000 17.6 83 49,800 14.6 1/2 1/2 4 1.0 2.4 15 155 60 769 21.8 1.25 0.12 616 188 0.03 0.06 1550 12 40 67 30 74 33 75,000 22.0 83 62,250 18.3 1/2 1/2 4 1.0 3.3 15 217 60 961 27.5 1.25 0.12 770 238 0.06 0.06 1550 12 49 72 33 79 36 105,000 30.8 83 87,150 25.6 1/2 1/2 4 1.0 3.9 15 276 60 1345 36.7 2.01 0.19 668 196 1/30 1/4 1050 16 54 96 44 118 54 120,000 35.2 83 99,600 29.2 1/2 1/2 4 1.0 5.1 15 354 60 1537 45.9 2.01 0.19 763 245 1/20 1/4 1050 16 55 101 46 123 56 A CSA rating for altitudes to 2000 ft. B Size shown is for gas connection to a single stage gas valve, not supply line size. C Smaller or larger vent pipe diameters may be allowed; refer to the Venting Installation Manual, Form I-V-PV. If vent diameter is different from vent connection, reducer/enlargers will be field-required. D MODP = 2.25 x (largest motor FLA) + smallest motor FLA. Answer is rounded to the nearest commercially available circuit breaker. E All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. MODEL UDAP TECHNICAL DATA Sizes 150 - 400 Size BTUH kw/h Input Heating Capacity Thermal Efficiency (%) BTUH kw/h Natural B Gas Connection (inches) Propane C Vent Connection Size (inches diameter) Control Amps (24 volt) Full Load Amps (115 volt) D Maximum Over Current Protection (115V) Normal Power Consumption (watts) Discharge Air Temperature Rise (°F) CFM Air Volume 3 M /minute 2 ft Discharge Air Opening Area 2 M FPM Output Velocity M/minute Open E Fan Motor HP Enclosed Fan Motor RPM Fan Diameter (inches) Sound Level dba @ 15 ft lbs Approximate Net Weight kg lbs Approximate Ship Weight kg Output Heating Capacity A 150 175 200 225 250 300 350 400 150,000 43.9 83 124,500 36.4 1/2 1/2 5 1.0 3.8 15 392 60 1921 54.4 2.56 0.24 752 229 1/6 1/4 1050 18 51 172 78 204 93 175,000 51.2 83 145,250 42.5 1/2 1/2 5 1.0 3.8 15 392 60 2242 63.5 2.56 0.24 877 267 1/6 1/4 1050 18 52 187 85 219 100 200,000 58.6 83 166,000 48.6 1/2 1/2 5 1.0 4.6 15 491 60 2562 72.5 2.56 0.24 1003 306 1/6 1/4 1050 18 53 187 85 219 100 225,000 65.9 83 186,750 54.7 3/4 3/4 5 1.0 7.5 15 747 60 2882 81.6 3.51 0.33 820 250 1/4 1/4 1050 20 56 203 92 245 111 250,000 73.2 83 207,500 60.8 3/4 3/4 5 1.0 7.5 15 747 60 3202 90.7 3.51 0.33 911 278 1/4 1/4 1050 20 56 215 98 257 117 300,000 87.8 83 249,000 72.9 3/4 3/4 6 1.0 11.0 20 1086 60 3843 108.8 4.79 0.45 802 244 1/2 1/2 1050 24 59 269 122 321 146 350,000 102.5 83 290,500 85.1 3/4 3/4 6 1.0 11.0 20 1086 60 4483 126.9 4.79 0.45 936 285 1/2 1/2 1050 24 61 294 133 346 157 400,000 117.1 83 332,000 97.2 3/4 3/4 6 1.0 11.0 20 1086 60 5123 145.1 4.79 0.45 1069 326 1/2 1/2 1050 24 62 306 139 358 163 Form RZ-NA-C-UH Page 7 Page __________ of __________ Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS p p p M N R - Hanger Dimension for 2-pt Suspension Combustion Air Inlet P P and Q Hanger Dimensions for 4-pt Suspension R TOP VIEW Q Thermostat Connection REAR VIEW (30-125 Vertical; 150-400 Horizontal) 3/8”-16 Female Thread - all suspension points G J Line Voltage Inlet (connects at circuit board) B H External Gas Connection F FRONT VIEW A C ® REZNOR D Form RZ-NA-C-UH Page 8 K E RIGHT SIDE VIEW (Access Panel) Vent Connection (see Technical Data for size) Page __________ of __________ Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS (cont'd) MODEL UDAP DIMENSIONS (± 1/16") Size 30, 45 60 75 100 125 150, 175, 200 225, 250 300, 350, 400 A 12-1/8 15-1/8 15-1/8 23-1/8 23-1/8 B 26-5/8 26-5/8 26-5/8 26-5/8 26-5/8 C 10 13 13 21 21 20-1/8 38-3/16 16 23 42 35-3/8 26-1/8 38-3/16 22 23 42 35-3/8 13-1/16 8-13/16 34-1/8 30 23 42 35-3/8 17-1/16 41 D E F G 13-13/16 26 21-9/16 5-3/16 13-13/16 27 21-9/16 7-7/8 13-13/16 27-5/8 21-9/16 7-7/8 13-13/16 28-5/8 21-9/16 14-1/2 13-13/16 29-3/8 21-9/16 14-1/2 8-1/2 H 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 J 2-11/16 5-1/2 5-1/2 8-3/4 8-3/4 K 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 8-1/4 5-7/16 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 16-3/8 9 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 15-5/8 9 M 17-3/8 17-3/8 17-3/8 17-3/8 17-3/8 N 11/16 11/16 11/16 11/16 11/16 P 4-5/16 4-5/16 4-5/16 4-5/16 4-5/16 Q 13 13 13 13 13 R 9-9/16 10-1/2 10-1/2 10-1/2 10-1/2 11-13/16 7-5/16 27-11/16 1-3/8 8-3/16 22-3/16 16-3/16 MODEL UDAP DIMENSIONS (± 2mm) Size 30, 45 60 75 100 125 150, 175, 200 225, 250 300, 350, 400 A 308 384 384 587 587 B 676 676 676 676 676 C 254 330 330 533 533 D 351 351 351 351 351 E 660 686 702 727 746 F 548 548 548 548 548 G 132 200 200 368 368 H 165 165 165 165 165 J 68 140 140 222 222 K 98 98 98 98 98 M 441 441 441 441 441 N 17 17 17 17 17 P 110 110 110 110 110 Q 330 330 330 330 330 R 243 267 267 267 267 511 970 406 584 1067 899 216 210 138 165 652 35 208 564 416 664 970 559 584 1067 899 332 224 229 165 652 35 208 564 397 867 1041 762 584 1067 899 433 229 300 186 703 35 208 564 411 CLEARANCES Size Top inches mm Flue Connector inches mm Access Panel inches mm Non-Access Side inches mm Bottom* inches 1 25 6 152 18 457 1 25 1 30-125 4 102 6 152 18 457 2 51 1 150-400 *Suspend the heater so that the bottom is a minimum of 5' (1.5M) above the floor. Rear mm inches mm 25 25 18 18 457 457 Form RZ-NA-C-UH Page 9