Request for Information Phase 1-RFI 178 Detailed, RFIs Grouped by RFI Number 4682 - Endless Mountains Health Systems Route 706 100 Hospital Way Montrose, PA 18801 Project # 4682 Tel: (570) 432-0109 Fax: (570) 287-0298 RFI #: Phase 1-RFI 178 Date Created: 9/19/2012 Answer Company Answered By Author Company Stratton Brook Associates 244 Farms Village Road Post Office Box 576 West Simsbury CT, 06902 W. Randolph Cole Sordoni Construction Services, Inc. Jeffrey Kiluk 45 Owen Street Forty Fort, PA 18704 Co-Respondent Julie Solomon Author RFI Number Noto Subject Main Level Clean Linen Room Swap Cc: Authored By Company Name Discipline Architectural Contact Name G. R. Noto Electrical Const A J Palazzari Andy Kingery Dunmore Roofing & Supply Rado Enterprises, Inc. Corey Yule Village Carpet Bill Fehringer Georgetti Painting Company Rudy Georgetti Sordoni Construction Services, Inc. Joseph Homza American Millwork & Cabinetry, Inc. Jeffrey Mease Standard Iron Works Kristi Dennebaum McMullen Hopson Specialty Systems Brian Lombardo Caretti, Inc. Mark Fesler Arrow Auto Glass Operating Co. Rich Kaminski LLC Classic Fire Protection, Inc. Stacy Clum Category Drawing Discrepancies Copies Notes 1 1 1 1 1 1 1 1 File 4682 1 1 1 1 Question Date Required: 9/26/2012 It was discussed on Wednesday 9/12/12 between Randy Cole, Mark Gendron and G.R. Noto that the Clean Linen Room (1733) would be switched with the Electric Room (1712) on the main level. Please provide an updated drawing to show the revised layout of this area. Suggestion Answer Julie Solomon responds on 09/19/2012: ... See attached sheets A-111 & A-411. Prolog Manager Printed on: 9/21/2012 Date Answered: 9/19/2012 SCS PA Page 1 General Floor Plan Notes Stratton Brook Floor Plan Legend Note: Main Level is at elevation 1773.0' fec 1. Refer to Floor Plan Legend for list of typical abbreviations and typical architectural graphic legends and symbols. Fire Extinguisher Cabinet fec-1 Fire Extinguisher Cabinet in CMU Wall A S S O C I A T E S 2. Refer to Sheet A-801 for typical partition types and details Indicated. All partitions to be type 0 unless noted otherwise 3. Refer to the fire safety plans on sheet G-002 for locations of smoke compartmentation. Wall Bumper wg2 Wall Guard with integral handrail wg 4. Dimensions are from face of stud to face of stud. Dimensions noted as "clear" shall be from finish face to finish face. cg-4 5. All Masonry dimensions, Indicated as "M.O." are nominal dimensions unless noted otherwise. Actual masonry opening dimension = Nominal masonry opening dimension + one mortar joist (I.E., 4'-0" M.O. = 4'-0" + 3/8" Actual opening dimension) Stainless Steel Corner Guard Wall Types (see Sheet A-801 for partition types) 2.2 6. Refer to plan enlargements for additional dimensions. 1010 Door Number Designation (see Sheets A-802 thru A-804 for door schedules) 7. Refer to Drawings A-805 & A-806 for door and frame details. Provide minimum 4 inch clearance from face of door jamb to face of adjacent wall, unless noted otherwise. BL-12 Window Number Designation (see Sheets A-??? for window schedules) sheet number 8. Refer to Sheet A-800 for typical mounting locations and heights for toilet accessories, equipment, wall specialty designations, visual display boards, ETC. Typical toilet room room elevations and toilet accessory schedule. Interior Elevation Designation (see Sheets A-900 thru A-912 for interior Elevations) A-900 5A elevation number section number 9. Provide fire treated wood blocking or minimum 0.0312" thick steel flat strap and backing plate at, but not limited to, the following locations: toilet accessories, casework, millwork, door wall bumpers, and all other wall mounted equipment or devices. P.O. Box 576 244 Farms Village Road West Simsbury, CT 06092 Tel: 860.651.6751 Fax: 860.651.6572 Corner Guard cg 8 A-900 Section Designation 8 A-900 Detail Designation sheet number 10.Refer to interior elevations for casework elevations. detail number 11.Refer to the finish plans for the floor patterns. sheet number 9' - 0" 9' - 0" 10" F2 2G A-915 3G 0 5G A-915 0.1 A-915 0.1 0.1 MD Ofc 1908 Pulmonary Function 1906 1904 0.1 F2 1 A-915 7F 1912 Pat Tlt 1911 1908 2' - 10 1/4" 9' - 0" 1903 1905 1902b 0.1 9' - 0" 9' - 0" 1907 9' - 0" 1909 3' - 4" 0 3' - 8" 15' - 4 1/2" 1' - 3 1/2" 1' - 3 1/2" G 0 9G EKG, EMG, Holter 1903 0 2' - 10" 0 0 Exam 1909 5' - 3 3/4" 2' - 3 3/4" 1' - 3 5/8" 1 6' - 0" 3' - 3 5/8" typical cg 1 3' - 0 1/8" F2 1 1006 0 Drop-Off 0.1 4 3/4" Women 1005 A-912 3G Bulk Storage 1918 6A A-800 PL.1 2G A-912 11' - 9" 13' - 8 3/8" 15' - 0" Soiled Workroom 1517 1 F2 1 wg2 3 1511 80 SF 80 SF cg wg2 wg2 wg2 2 1512 wg2 1 1513 86 SF 87 SF wg2 0.1 A-912 8' - 2 3/8" 8' - 4 7/8" 4' - 0 3/4" PACU Nurse 1518 cg wg2 cg 1027 wg 0.1 10' - 6" Equipment Storage 1555 PL.1 104' - 7 5/8" face of EIFS to face of brick 2' - 5 1/2" D.6 1 2 1521 1' - 1" 2' - 0" 1 I.T. 1028 1 1520 125 SF E 84 SF wg2 Reviewed By: Date: Revision No. and Date: SB08A Cole 09/19/2012 wg2 0.1 0.1 1028 fec 14' - 3 1/4" 27' - 4 5/8" 3 A-611 4 7 Sim 6A A-804 Revision 1 RFI-080 RFI-085 Rev. 4 Shaft Enlarged Rev. 4 RFI 127 Rev. 4 RFI 126 Rev. 4 Dimension tolerance Rev. 4 1805 door swing Rev. 4 Dimension clarification Rev. 4 RFI 178 08/16/2011 03/20/2012 04/24/2012 05/21/2012 07/03/2012 07/12/2012 08/29/2012 09/07/2012 09/13/2012 09/19/2012 1027a 1' - 5 1/4" 2' - 8" concrete pad and location of exhaust fans from kitchen below 0.1 5' - 4 7/8" PL.1 1920b 0.1 9 5/8" 0.1 1918 10' - 2 3/8" 1919a 10' - 2 3/8" 1919b 1' - 11 1/4" EMHS Dispensing 1919 0.1 Exit and Delivery Vestibule 0.1 1920 1' - 3 1/2" A-915 5H 1' - 9" 10 1/2" 8 3/4" 3' - 10" Drawing Name G Phase 1 Main Level Plan 2' - 8" Sim 2A A-804 30' - 0" Project Number: F F2 30' - 0" This project has been designed by me, or under my supervision, in accordance with the 2009 International Building, Plumbing, and Mechanical Codes, the 2008 National Electrical Code, and applicable Federal, State and local laws, codes and regulations; and to the best of my knowledge and belief, these construction documents are in conformance therewith. RA404343 Registered Architect PA Reg. No. Date 1A A-141 wg2 0.1 wg2 cg 1920a 15' - 0" 3' - 3" 26' - 4" AL-5 wg2 5 13 A-610 wg 69' - 10" 4' - 2 3/8" 9' - 4 5/8" wg2 7B A-912 5B 19' - 4" A-911 8" 1555 86 SF wg2 cg wg2 1 12' - 3 1/4" 1 wg 8' - 4 7/8" 104' - 4" face of stud to face of stud wg2 8' - 7 3/8" A-912 3F emerg cart fec 0.1 16' - 3 5/8" 4' - 2 3/4" 7' - 8 5/8" wg2 21' - 3" 5' - 1 1/4" wg2 6' - 0 1/4" wg2 D 1552b 3 1522 2' - 7" 4F wg2 wg2 cg 6B 0.1 Vestibule 1551 1 Post Anesthesia Care Unit 1519 1507 wg2 0.1 1 8 3/8" 2' - 3 5/8" 1512 wg2 cg 0.1 wg2 9 5/8" 8' - 9" wg2 cg Women's Lockers 1552 81 SF 3' - 6 1/8" Sim 7E A-917 2' - 2 5/8" stretcher alcove cg wg2 wg2 5' - 11 1/8" wg2 fec 1517a cg cg-1 4C A-800 8" wg2 9' - 1" Shower 1553 1' - 8" cg-1 3' - 7" 0 cg 7' - 8 7/8" cg-1 wg2 3A A-141 4 1510 cg wg2 0.1 F2 8' - 1 1/4" Outpatient Pre-Op/ Stage II Recovery 1507 8" wg2 1519 cg-1 1550 Toilet 1550 8' - 0 1/4" wg2 1 5A 1' - 6 3/4" cg 80 SF cg 4B A-912 3B 7A A-912 2B 8' - 8 3/4" 1553 1' - 8" 1515 8" 10' - 8" MedsA-912 1515 Nourish 1516 6A 0.1 cg wg2 1517 wg2 7' - 2 3/8" wg2 8' - 4 5/8" fec wg2 1 2A 6' - 2 3/4" 9 5/8"1 1' - 8A-611 3/8" 30' - 0" 6' - 8 3/8" wg2 1516 F2 5' - 4" m.o. 18' - 0" 7' - 8 3/8" wg2 2 A-611 6' - 4 3/8" 100 Hospital Drive Bridgewater Township Montrose, PA 18801 C F2 F2 8' - 1 3/8" cg 7' - 5 3/4" 5' - 11 1/2" 2 A-606 6' - 8 3/8" Nurse Station 1514 Semirestricted Corridor 1523 1523 O.R. Mgr 1524 Toilet 1548 cg wg2 5' - 11 1/2" wg2 1541 1548 4' - 11 7/8" 1552c wg2 1 Vestibule F2 1554 9' - 11 3/8" 1 wg2 3' - 2 3/8" 1 7' - 0 3/4" 6' - 11 1/4" 1 4 A-606 1524 wg2 1540a 1 Hskpg 1541 3C A-912 1543 S3 Shower 1549 9 5/8" cg cg 5 1509 6' - 2 5/8" wg2 8' - 1 1/4" 3' - 5 5/8" S3 linen chute 8' - 1 1/4" 8" 1552a 1547 10' - 2" 6D A-912 5D S3 2C 8' - 1 1/4" 80 SF 1' - 3 5/8" 9' - 4 1/4" 3' - 10 1/4" 1' - 8 1/4" 6' - 9 5/8" 3' - 7" 1 1 cg cg 6 1508 3' - 0 3/4" 1 Soiled F2 Workroom 1543 10" wg2 11' - 0 1/4" 1 1543a 5' - 10 5/8" 8' - 2 3/8" 9 5/8" 6' - 2 3/4" Men's Lockers 1547 Semirestricted cg Corridor 1544 7' - 0 3/4" 4 BL-3 6' - 0 5/8" wg2 wg2 wg2 10' - 7 1/2" 6' - 3 3/8" wg2 6' - 2 3/8" 3' - 0 1/2" 5 A-606 2' - 8 1/2" 2' - 2" 2' - 7" wg2 wg2 5' - 8 3/8" 5' - 5 1/4" Corridor 1506 1539 1 6' - 2" F2 1 Hskpg 1528 7' - 7 3/8" 1505 2' - 1" 3' - 8 3/4" SS counter and storage 8' - 1 1/4" 6' - 3 1/2" 40 SF fec 15' - 0 3/8" 5' - 8" SS storage SS storage 40 SF 1 pat belongings wg2 5' - 1 1/4" 5' - 1 1/4" Patient Toilet 1505 1504 1' - 6 3/4" 3' - 8" 1' - 8 3/8" 6' - 9 5/8" 2' - 11 3/4" 2' - 10" 10' - 11 1/4" 6' - 0 7/8" 3' - 7" 3' - 7" 3' - 10 1/4" 1' - 7 3/8" 18' - 7 1/4" 18' - 11 3/4" 9 5/8" 6' - 1 1/4" 2' - 11" 6' - 1 1/4" Patient Toilet 1504 Clean Storage 1540 2' - 11 1/2" cg 7' - 9" F2 8' - 1 1/4" 5' - 8 3/8" 1540 6" stud wg2 0 3' - 3 1/2" 1D A-141 1545b F2 2' - 8 3/8" wg2 7C cg 1C A-142 1' - 10 3/8" 4' - 5 1/4" cg 13' - 0 3/4" 6 0 4' - 0" clear Retail Dispensing 1916 wg2 5' - 1 1/8" 2E A-801 PL.1 3' - 6" 8' - 1 1/4" 0.1 9 5/8" 8' - 2 3/8" 1503b cg 7' - 8 3/8" wg2 3' - 8 3/8" 5' - 10 1/2" A-912 1545a A-912 8F F2 Restricted Corridor 1539 8' - 8 3/8" 1528 fec 0.1 F2 Staff Lounge 1545 B.3 Replacement Hospital and Physician Suite 0.1 Men 1006 0.1 22' - 0" 0.1 cg wg 0.1 1544 1' - 7 3/8" 25' - 11 3/8" Restricted fec Corridor 1530 1545 cg 9' - 0 5/8" Pharmacist 1917 0 wg 1500 cg cg 2D 1 0.1 GL1 8' - 3" 11' - 0 3/8" 0.1 20' - 2 5/8" 0.1 20' - 11 1/2" 7H A-915 1' - 11 5/8" scrub sinks F2 0.1 1552 white board 1525 cg F2.1 3E A-912 Authorized cg-2 Access Only 0.1 wg2 cg Stair B 9' - 7 1/4" 1040b F2 Meds 1529 wg2 Patient Visitor Elevator Lobby 1026 GL1 cg 4' - 10" 1506 wg2 1 600 SF wg2 3' - 2" wg2 7' - 5 3/4" A-916 F2 F2 2' - 10 1/4" Sim Sim 3C 2C A-916 A-916 Clean Scopes 1527 5' - 5 3/4" 4C 1 A-600 F2.1 2' - 0 3/4" F2.1 F2 6' - 0" Outpatient Surgery Reception Seating 1500 7' - 8" F1.1 8' - 10 7/8" 7' - 5 3/4" cg wg 1 0.2 2' - 10 1/4" F2.1 F1.1 1 O.R. 2 Orthopedics 1536 1529 cg 1525a 0.1 cg cg-1 1532 0.1 cg-2 cg-2 4' - 11" wg2 1536 F2 cg-1 5C 1 0.1 F2 1 cg 1503 6' - 1 1/4" A-912 4D cg 6C A-912 4C 2' - 0 1/4" 8' - 1 1/2" 2 A-600 0.1 0.1 BL-6 sinks wg2 3' - 2" 0.1 0.1 BL-1 6G A-913 3G A-912 303 SF 1 wg 4C A-710 1' - 6 3/4" 8' - 11 3/4" 6' - 4 5/8" 5E 1535 scrub F2 A-912 Anesth F2.1 1501 A-912 4E 8" Elev A 1534 2' - 3 5/8" 6' - 10 1/2" wg2 wg2 1532 7D 1' - 9 3/8" F2 Pathology 1531 Special Procedure/ Endoscopy 1525 F2.1 Subwait 1503 BL-1 Endless Mountains Health Systems UP 4D A-144 8' - 1 1/4" F2 1535a 6' - 4 3/4" 1' - 11 1/8" 1503a A-912 3A Recept 1501 1034 1C Outpatient Imaging Reception Seating 1700 8' - 9 1/8" 1917 4A BL-1 B fec wg F2.1 0.1 10' - 0 5/8" 8C A-710 1' - 9 3/8"Substerile cg F2.1 8' - 8 3/8" F1.1 wg 2A A-714 4' - 4 7/8" 1' - 1 1/2" 3H A-915 3' - 10 1/4" Patient Admission 1034 Corridor 1033 F1.1 Sim 3' - 10 5/8" 1wg2 8' - 10 5/8" 8' - 0 5/8" 8' - 8 3/8" fec 1531 3' - 8 1/8" 1526 1' - 2 3/8" 8' - 11 3/8" cg Patient Consult/ Exam 1502 Nutritionist/ Dietician 1035 1535 2D A-912 Soiled Work 1526 1502 1033 21' - 11" 0 wg2 9' - 1 3/8" 4' - 7 3/8" 2C A-916 0.1 11' - 8 3/8" 2' - 10 1/8" cg cg Pick-Up 6' - 3" 9' - 3 1/2" 7' - 10 1/4" 5' - 6 3/4" 2' - 1 5/8" 4' - 0" 1' - 10 1/4" 6' - 1 1/4" 9' - 9 3/4" fec wg2 3D 6' - 1 1/4" 5' - 8 3/8" 4 warming cabinet 1 1 wg 0.2 6' - 0" Sim 1 13' - 5" 2' - 2 5/8" 6' - 8 3/8" wg 4' - 8 3/8" 3' - 0" cg-2 cg-2 S3 flash sterilizer BL-6 6' - 1 5/8" 1' - 9 5/8" cg wg2 4' - 8 3/8" 2' - 2 3/8" 6 1709 wg 416 SF 5F A-912 6" stud 3' - 0" 4G O.R. 1 General 1534 1031 Corridor 1032b A-714 8' - 11 1/8" wg2 3' - 3 1/2" 4A A-144 5' - 10 1/4" F1 A-914 2E cg-1 Check Out 2H Private 1602 1032b 1035 0.1 3E 12' - 6" 4' - 4 7/8" 4 1C A-141 12' - 10 7/8" S3 13 SF Phlebotomy 1601 10' - 6" S3 cpr wg2 9' - 0 3/8" cart S3 4' - 0 5/8" 1033a Reception 1701 2' - 7 3/4" 4' - 1" 1609 2' - 7 3/4" 7' - 7 1/2" 5' - 1 1/4" Stair A 7G A-915 1' - 11 5/8" 2A 1' - 11 5/8" cg-2 cg-2 4F S3 S3 Elec 1031 8' - 2" 1600 wg 1709 5' - 1 3/8" 6H Exam 1910 2' - 3 5/8" 5' - 0 1/8" 5' - 1 1/4" 5' - 2" 9' - 3 7/8" 0.1 243 SF 1031a 1602 0.1 0 1910 1604 7' - 5 3/4" A-914 4E 5 1708 1916 A-915 Exam 1907 7' - 2 7/8" Gate, see 2C /A-706 for detail 7E Exam 1905 7E BL-1 6F A-913 3F S3 Corridor 1032a 4A A-914 F2 BL-1 0.1 0.1 5' - 7 3/8" 8' - 0 1/8" wg 4' - 8 3/8" 10' - 2 3/8" 8' - 0 1/8" wg 4 1707 4D A-710 wg2 F2 8E A-914 A-600 1706 BL-1 1 3' - 11 5/8" Spec. Tlt 1604 3A A-914 S3 5' - 11 1/4" F2 F2 F2 4' - 1 3/4" 10' - 7 1/8" 6' - 1 1/4" 2' - 9 5/8" BL-1 0.1 6E A-915 0 3 1706 1700 0.1 10" 1' - 8 7/8" 6' - 8 7/8" fec Outpatient Lab Reception Seating 1600 fec 6A 16' - 4 5/8" 4C 9' - 8 3/8" 3' - 0" 1601 5D A-914 2C 8' - 8 3/8" 0 5' - 1" 6' - 0" m.o. AL-3 Nurse Station 1901a 9' - 11 1/8" 21' - 10" 2' - 3" 6' - 3 1/2" BL-1 2' - 10" 7C Dept Mgr 1714 Storage 3 1713 F2 1 ref 1' - 10 5/8" 6' - 9 3/4" 1' - 6 1/2" 6' - 4 7/8" 1 Urinalysis 8' - 10 5/8" 3' - 0" 0.1 1715 4' - 7" A.8 F1 wg F2 foot controls 0.1 3' - 6 7/8" 1708 3C A-916 2' - 8 3/8" 10" BL-1 7B A-914 8A Lab Manager 1606 3C 0.1 1714 Dressing Rooms 1703 6F A-915 7' - 8 3/8" 5' - 1 1/4" 2' - 3" 9 5/8" A-915 6G BL-1 1606 1' - 8 3/8" Bone Density 1715 Elev B 2A A-804 cg-2 cg-2 3B A-914 5A 2D 2F wg 8' - 2 3/8" 9 5/8" 1' - 0 3/4" 7' - 7 7/8" 6' - 1 1/4" F2 2' - 6 7/8" 1' - 7 5/8" 4' - 4 3/8" 1607 wg 10' - 0 7/8" 5' - 6 3/8" Retail Pharmacy and Gift Shop 1915 A-915 5F Check In3F Check Out 1901 cg 0.1 6' - 0 1/2" Chemistry Coagulation 8C A-914 6C 0.1 1716 1705 6' - 11 1/2" 0.1 0 8G A-915 fec 1915 0.1 3' - 9 1/4" Corridor 1902 6' - 1 3/8" 9' - 9 1/8" 1911 0 1 5F Patient Toilet 1716 2 1705 1704 cg cg BL-1 8B Microbiology 1607 3F A-914 7' - 2 3/8" Corridor 1037 0.1 ref NIC freezer NIC fec 0 1906 4' - 8 3/8" 2' - 9" 5' - 8 3/8" wg wg BL-1 1' - 0 1/4" 8' - 6 3/4" Hskpg 1608 1608 Laboratory 1605 11 3/4" 2 5' - 8 3/8" 9' - 7 3/4" 1 1' - 0 1/4" 10" 10" 5' - 8 3/8" fec cg 8' - 1 1/4" 1037 A-911 5' - 1 1/4" wg 4' - 9 1/4" 2' - 9 1/2" wg 14' - 9 1/2" 5' - 1 1/4" 6' - 1 1/4" 5' - 6 1/8" Respiratory Therapist Office 1912 1 1704 1700a 6' - 7 3/4" 3' - 6 1/2" 3 1 10' - 6 7/8" 2' - 8 3/8" 12' - 7 5/8" 6' - 5 3/4" wg 8' - 8 7/8" wg 5' - 8 3/8" wg wg 8' - 6" 8' - 7 3/4" 1' - 0 1/4" 0.1 7' - 11 5/8" 4B cg-2 PA License RA404343 Sim wg Corridor 1040 1' - 7 3/8" emerg shower and eye wash 6F 0.1 0.1 0.1 3' - 6" 1934 1122 2F 1/2" 3' - 7 0.1 wg 0.1 3/4" 3' - 4 1/8" 2' - 11 5C F2.1 5' - 7 3/4" 4' - 8 3/8" 0.1 F2 A. 3' - 0 3/4" 0.1 6H A-914 7H 2' - 9 3/4" wg Stress Test 1904 4' - 4 1/4" 1/8" 1' - 0 /2" 1 3' - 4 1/2" 1' - 8 1 Reading A-914 1720 5' - 1 3/8" wg cg cg BL-1 6B A-914 5B 1' - 3 1/2" 6' - 0" 11' - 10 1/4" 10' - 7 5/8" Vending 1934 Walls to have STC 65 min. and ceiling to have STC 45 min. cg 4' - 11 1/8" 6' - 2 1/2" AL-3 8' - 0 1/8" 5' - 4 1/4" fec 5' - 3 3/8" 0.1 I.T. 1802 B. 1802 1 0.1 3H EMHS Registration Reception 1930 0 Sim 3C A-916 A-914 Film Storage 1719 1719 3' - 0" cg-2 Hematology A-914 1605 fec A-914 5H 3' - 8" 3/4" 2' - 9 4' - 8 3/8" 6' - 4 7/8" 7' - 6 5/8" 1 6' - 7 3/4" 13' - 7 1/8" 5' - 1 1/4" 1' - 10 5/8" Public 0.1 Toilet Bereavement 1803 1801 0.1 3' - 4" 6' - 0" m.o. F2 1 1931 5' - 2" Corridor 1702 3' - 6" 0 F2 CR system, scanner, printers, etc. 1720 7' - 6 1/8" 1707 Mammo 1710 0.1 EMHS Registration 1931 1801 1902a 29' - 0" 0.1 8' - 4 7/8" 0.1 0.1 F2 4' - 1 1/4" Corridor 1711 cg 6' - 8 1/4" 5E 0.1 9E A-915 0.1 8C 8 1/4" 1722 1932 1 Physician Suite and Respiratory Therapy Reception 1900 9' - 0" face of stud to face of stud 9' - 0" face of brick to face of brick 4A A-800 8' - 2 3/8" 1' - 8" fec 1 7" 1 1 5' - 8 3/8" 4' - 10 3/8" 8E Admin. Ofc. 1932 1933 A-915 9C 1803 cg F2 AL-3 Admin. Ofc. 1933 8F 9 5/8" 1712 Hskpg 1722 A-914 F2 A-913 6D 8' - 2 3/8" 1' - 6" 1' - 8" 6' - 5 3/4" 2' - 9" 12' - 0" m.o. 3' - 9 3/8" 4' - 4" 1' - 0" 18' - 0" 1' - 0" 4' - 8" 1' - 0" 6' - 0" m.o. 1 Pat Tlt 1728 1 F2 3' - 0 5/8" Hi-Lo E.W.C. 0.1 Clean Storage 1610 1713 wg Clean Linen 1712 /2" F.1 9 5/8" 0.1 F2 1718a F2 1710 1728 1836 7' - 10 1/4" equip wg cg wg 5/8" 6' - 0" 7D 5' - 8 3/8" cg-1 cg-1 1' - 11 F2 cg A-914 7F cgF2 1 5' - 2 1 BL-2 0.1 1717 9' - 5" 12° 5' - 8 3/8" wg 0.1 wg2 7' - 7 1/4" 6E /2" wg BL-3 s.s. 9' - 1 1/4" Emergency Department Lobby 1038 1039 wg A-913 1' - 9 5/8" 2' - 9" F2 cg 3' - 0" 1032a 0.1 1 1718 A-914 3' - 0" 1606a cg wg 2' - 7 3/4" Triage 1835 Patient Toilet 0.1 1836 wg2 wg fec 1834 2E cg 1' - 8" cg-2 F2 0.1 cg cg 1' - 8" cg 5' - 8 3/8" 6' - 9" BL-3 1835 Sim cg 2C A-916 A-913 1729 Staff Corridor 1613 0.1 Soiled Holding 1717 3' - 0" BL-1 1 3D 1 0.1 4 Elec 1733 1 5' - 2 F 7' - 4" 1' - 3" cg-2 Airborne Infection Isolation Room 1834 wg2 wg 0.1 2' - 7 3/4" Ultrasound 1729 11' - 6" Hskpg 1833 1733 12° 8" 0.1 3' - 0" 0.1L 9' - 5 3/8" 12' - 3 3/8" 8' - 0" 8C Sim 4 9 5/8" 3B 0.1L 0.1L 259 SF 3' - 4 1/8" 2' - 4" A-913 2B 2C A-142 F2.1 0.1 wg 1835a 0.1 Emergency Walk-in Vestibule 1039 F2.1L 5' - 8 3/8" Reception/ Security 4B 1804 8' - 0 1/4" Sim 6A A-804 1039a 5' - 4 1/4" cg 0.1 5 A-610 12' - 4 1/4" 8' - 1 1/4" F2.1L 0.1L 1834a 1833 F2.1L 0.1L cg wg2 cg Toilet 1612 1612 Radiography 1736 8' - 1 1/4" Nuclear Medicine 1730 12' - 6 7/8" fec cg wg F2 Staff 4F A-914 Blood Bank 4D 1609 0.1 1610 11' - 5 5/8" 1L Soiled Workroom 1827 A-913 BL-5 5' - 10 3/4" BL-1 1611 8' - 3" 1737 6' - 6 7/8" wg 0.1 2 A-601 A Gate, see 2C /A-706 for detail 4 7/8" AL-8 1742a Ref. Tech Work 1718 4' - 1" 3 5/8" 13' - 3 1/2" wg 1' - 2 1/4" AL-13 2' - 5 5/8" Corridor 1832 1' - 3" E 8' - 2 3/8" 1730 4D 1 17' - 0 5/8" 633 SF 18' - 2" 2D A-141 cg cg wg 1' - 10" ED Walk-In Reception Seating 1800 8" 9' - 4 5/8" F2 1827 5' - 0 7/8" 3A A-142 5' - 8 3/8" 8' - 3 3/4" 2' - 7 3/4" AL-2 0.1L 1 1 2' - 6" 0.1L 9 5/8" 0.1L 1736 1732a 1731 2' - 9 3/4" wg 1804 4 7C cg Corridor 1734 1732 4' - 4 1/4" wg2 cg 8' - 1 1/4" 9' - 4 1/4" 9' - 4 1/4" F2 1831 9 5/8" 6' - 2 3/8" 1800 1 Hot Lab 1731 F2.1L 3 5/8" F2 3C A-916 9' - 0" m.o. F2 1' - 6" 1805a 13' - 10" 3' - 4" 11' - 2 1/2" 8 117 SF A-610 cg D.9 F2 Patient Toilet 1831 F2 1805 1' - 0" 7E 29' - 0" 12' - 0" m.o. A-913 1' - 1" D.6 wg2 cg-2 cg-2 cg-2 0.1 ref NIC Control 1737 F2 F2 1' - 9 3/8" 10' - 9" 1807 cg wg2 T-1/ 8E Secure 1805 1L A-914 Patient Toilet 1732 1' - 9 1/2" Patient Toilet 1807 cg cg AL-1 A-913 F2 F2.1L 1735 0.1L 8F cg CT Control 1735 2' - 2" 8' - 1 1/4" cg 2' - 11 1/4" 4 wg2 4 1 1 drug warming disp cab Clean Workroom 1822 wg cg 3G A-914 1 Pat Tlt 1739 5' - 10" 1613 6D 9 5/8" 0.1L 10' - 2 3/8" 2G 269 SF 1822 wg BL-8 8' - 2 1/4" 0.1 1' - 10 3/8" 4C A-141 0.1L wg2 cg-1 A-913 3D wg2 8G A-914 4G 4' - 1" 7G BL-5 3' - 3 1/8" 0.1L 1735a Trauma/ Cardiac 1819 wg2 wg 3' - 1" cg cg 8' - 1 1/4" wg wg wg 6' - 1 1/4" 12' - 0 3/4" 11 5/8" 4' - 7 3/4" 8B F2.1L 1739a BL-2 Staff Lounge 1611 A-914 0.1L 1739 2' - 11 1/8" BL-2 8D 6G 6' - 1" A-913 5E 0.1 5' - 1 3/8" 1' - 2 1/8" 8' - 2 3/8" Rad/Fluor 1738 0.1L wg2 Coats 1823 0.1L 1738 1740 1819 6' - 0 3/8" 2' - 5 5/8" 11' - 1 3/8" 17' - 4" 5' - 4" 123 SF wg2 cg 4' - 9 3/4" A-913 5' - 1 1/4" wg 1806 cg-2 0.1 10' - 7 3/8" 0.1L 1823 10' - 2 1/8" wg2 T-2 1806 cg wg wg2 cg cg-1 cg cg CT 1740 9 5/8" 9' - 0 1/2" Nurse/ MD Station 1811 wg fec 0.1 0.1L 3E 6' - 8 3/8" wg2 6C A-913 wg AL-1 fec 0.1L wg 5' - 10 7/8" Corridor 1820 cg 5C 5' - 1 1/4" 12' - 0" m.o. 124 SF 0.1 cg-1 cg 10' - 3 1/8" BL-2 1734 0.1 8' - 8 3/8" 10' - 7 7/8" T-3 1808 111' - 4" face of brick to face of brick 110' - 2" face of stud to face of stud 10' - 7 5/8" F2 A-913 wg cg wg 0.1L 7A 2' - 4 7/8" 4' - 5 3/8" cg wg2 0.1 6' - 1 1/4" Staff cg-1 Lockers 1821 6B 4' - 1" 16' - 0" wg2 cg 4' - 7 3/4" cg wg cg wg cg-1 D 1' - 10" cg-1 124 SF wg2 F2 3D A-141 2' - 1 3/8" wg Corridor 1809 T-4 1810 4' - 0" cg-1 8' - 1 1/4" 6A A-710 wg 10' - 7 7/8" 3A A-913 2 A-610 30' - 0" Corridor 1817 2A wg2 A-913 wg cg-2 1A A-142 10' - 3 1/8" cg-2 0.1L 1817 7' - 11 1/2" 7E A-917 5B 2C A-913 AL-1 Staff Lounge 1844 Staff Tlt 1845 wg cg wg2 wg 0.1 2' - 5 5/8" 0.1 0.1L scrub sink 1818 4' - 0 5/8" 0.1 19' - 1 7/8" cg-2 0.1 wg 2' - 9 1/4" 4' - 0" 103 SF cg wg2 wg BL-3 8' - 9 3/4" 4 10' - 0 3/4" 12' - 0" wg2 fec 4' - 0" cg wg AL-8 wg cg-2 1744 1745 0.1 wg 8' - 1 1/4" T-5/ 4A Decontam 1812 11' - 0 1/2" 2' - 8" 2A 5A A-913 A-805 0.1 2D A-913 wg 1' - 7 5/8" 9 5/8" 8' - 2 3/8" 6' - 1 1/8" Sim 15' - 5 3/8" 6' - 6" 1040a 9 A-610 Corridor 1742 3' - 8" Surgery 5' - 8 3/8" 11' - 4 7/8" wg cg fec cg cg-2 26' - 0" 12 A-610 AL-8 wg cg-2 0.1 1816 8' - 1 1/4" 1812 0.1 5' - 1 1/4" 8' - 1 1/4" wg 13' - 5 1/4" 6A 1813 2' - 9 3/4" wg cg cg 12' - 0 3/4" wg2 12' - 0" m.o. 8' - 2 1/4" 105 SF 0.1 4' - 10 1/8" 5' - 10 7/8" wg 0.1 wg2 4' - 6 1/2" T-6/ Decontam 1813 wg2 4' - 0" m.o. 2' - 0" wg 0.1 0.1 wg2 C 1814 wg2 AL-1 10' - 0" 12' - 0" m.o. 30' - 0" On-call 1814 9 1/2" B.3 6' - 8 5/8" 2' - 2 3/8" 9' - 6 3/4" Ambulance Entry Vestibule 1816 4' - 1 5/8" wg 0.1 cg 2A A-142 4D A-711 4 A-610 10' - 6 1/8" 16' - 8" 0.1 A-913 ED Mgr 1818 5' - 1 1/4" 10' - 8" 4C 7 A-610 1816b cg-2 4' - 0" Lab 1742 wg cg-2 cg-2 0.1 26' - 0" 11 A-610 A.4 DN 1743 4' - 0" 3' - 7" 144 SF AL-9 wg cg cg 0.1 wg wg F2 9' - 4 1/4" 0.1 1815 wg 4B A-800 8' - 1 1/4" wg 3' - 1 1/4" 0 4' - 10 1/8" B 1816a 26' - 0" 3' - 7 5/8" 10 A-610 15' - 4" Mobile Technology Dock 1743 7" AL-9 Sim 2A A-805 4" 3' - 4" Sim 4A A-804 5' - 2" 3' - 4" 3' - 7 3/8" Imaging 19' - 4" 14' - 1 1/2" Shower/Toilet 1815 3' - 4" 8' - 2 3/8" Emergency Department 19' - 0" 12' - 1 1/8" 26' - 0" m.o. 3' - 11 5/8" 4' - 0" 5' - 0" 26' - 0" m.o. 1' - 3 1/2" 8' - 0" A.4 7' - 4" 3' - 7 3/4" 12' - 0" m.o. Sim 6A A-804 cg 14' - 4" 8' - 0" 7' - 0" A 2 5/8" 9' - 10 1/2" 8" 30' - 0" 27' - 6" 30' - 0" 2 5/8" 6' - 0" 18' - 8" 8" 19' - 6" 11' - 4" 8" W. Randolph Cole, AIA 3' - 3 5/8" 11' - 4" 22' - 8 3/4" overall EIFS to EIFS 1 20' - 11 1/2" A-601 face of stud to face of stud 8' - 10 1/2" 11' - 3" 3 A-601 4' - 4 3/8" 18' - 8" 10 23' - 8 1/8" 30' - 0" 9.6 27' - 6 1/2" 30' - 0" 115' - 6 7/8" face of brick to face of EIFS 116' - 4 1/2" face of stud to face of stud 30' - 0" 9.3 30' - 0" 26' - 0" face of brick to face of brick 24' - 10" face of stud to face of stud 9 9' - 1 1/4" 30' - 0" 8 3' - 1 1/2" 1' - 8" 7 wg2 8" 6 3' - 9" 108' - 8" face of brick to face of brick 108' - 0" face of stud to face of stud 5.4 7' - 4 3/8" 5 5' - 1 1/4" 4.6 1549 4 4' - 2 3/8" 3 wg2 7" 2 4' - 3 1/4" 1 30' - 0" 30' - 0" 21' - 0" 143' - 11 5/8" Drawing Number 0 1 1.3 2 2.3 3 3.3 4 4.3 4.6 5 5.35.4 6 7 8 9 9.3 9.6 10 Project North 1 Main Level Phase 1 Floor Plan 1/8" = 1'-0" A-111 copyright 2011 Stratton Brook A S S O C I A T E S P.O. Box 576 244 Farms Village Road West Simsbury, CT 06092 Tel: 860.651.6751 Fax: 860.651.6572 Shower/Toilet 1815 8' - 0" 10' - 0" Corridor Corridor Corridor 1742 1742 1040 Ambulance Entry Vestibule 9' - 6" 10' - 2" 1844 Staff Tlt 1610 Blood Bank 1609 8' - 0" 8' - 0" 1845 open to above Staff Lounge 9' - 0" 1611 3' - 10 1/8" 8' - 0" 10' - 0" 1740 1738 Staff Toilet 1612 Trauma/ Cardiac 9' - 6" 10' - 0" 1605 1613 8' - 0" CT Control 9' - 6" Control Film Storage 1737 1719 Tech Work Corridor 1735 1820 Staff Lockers 9' - 0" 8' - 0" 1601 1823 1732 Hot Lab Reading 1731 Corridor 8' - 0" 1820 8' - 0" 8' - 0" 8' - 0" 1717 Patient Toilet 8' - 0" 1716 Corridor Corridor 1711 1032b Storage 8' - 0" 8' - 0" Ultrasound 1831 1729 1805 2 3 1804 Triage 1704 1705 1706 Stair A 8' - 0" 8' - 0" 8' - 0" Dressing Rooms 1703 Pat Tlt Airborne Infection Isolation Room 9' - 6" 8' - 0" 8' - 0" 8' - 0" 1525 Semirestricted Corridor Mammo 1710 1932 4 5 6 1707 1708 1709 1555 1504 1505 1515 8' - 0" Subwait 8' - 0" 8' - 0" 8' - 0" Corridor 1503 1506 8' - 0" 8' - 0" Recept Nurse Station 6 Outpatient Pre-Op/ Stage II Recovery 1508 1507 8' - 0" 1501 1514 1033 8' - 0" Patient Toilet 1836 I.T. Admin. Ofc. 1802 1933 8' - 0" EMHS Registration Reception Reception 1930 Public Toilet Vending 1803 EMHS Registration 1934 8' - 0" 9' - 0" 1931 Bereavement 4' - 3 7/8" 8' - 0" Outpatient Imaging Reception Seating 6' - 5 1/8" Patient Visitor Elevator Lobby 1700 8' - 0" 1038 6' - 5 1/8" 6' - 0" 3' - 6 1/4" GB GB 8' - 6" 2' - 0" 3' - 0 3/4" 2' - 5 1/8" 9' - 0" Emergency Department Lobby 1039 2 1519 1521 9' - 0" 1518 8' - 6" 6' - 0" I.T. 4' - 3 7/8" 9' - 0" 1028 9' - 0" 1 1520 5 8' - 6" 1026 1509 GB 4 3 2 1 1510 1511 1512 1513 8' - 0" 89' - 7" BL-9 Corridor GB 1037 ? 2' - 8" 2' - 8" BL-9 12' - 0" 10' - 6" Post Anesthesia Care Unit PACU Nurse 48' - 5 1/4" 2' - 5 1/8" 1522 1500 1801 Emergency Walk-in Vestibule 1517 8' - 0" Outpatient Surgery Reception Seating T 9' - 0" 3' - 0" 1800 Elev A 1701 8' - 0" 4' - 1" ED Walk-In Reception Seating 3 8' - 0" 1834 Corridor 9' - 6" 8' - 0" Soiled Workroom 8' - 0" 8' - 0" 8' - 0" T 100 Hospital Drive Bridgewater Township Montrose, PA 18801 8' - 0" Meds 1034 8' - 0" Admin. Ofc. Equipment Storage Patient Toilet Patient Toilet Patient Admission 10' - 0" 1728 8' - 0" Special Procedure/ Endoscopy 9' - 0" 8' - 0" GB 1835 GB 8' - 0" 8' - 0" 9' - 0" 8' - 0" Replacement Hospital and Physician Suite 1551 3' - 7 1/8" 1523 9' - 0" Reception/ Security 1541 Vestibule Nutritionist/ Dietician 1 8' - 0" 8' - 0" Hskpg 1722 8' - 0" 1832 8' - 0" 1550 1524 1035 1712 1833 8' - 0" Toilet O.R. Mgr 10' - 0" 1502 Hskpg Clean Linen Hskpg T-1/ Secure 8' - 0" 1553 1540 1528 3' - 7 1/8" 8' - 0" 4 Patient Toilet 1714 1713 9' - 0" Patient Consult/ Exam Dept Mgr Shower Clean Storage Hskpg 9' - 0" 9' - 0" 8' - 0" Clean Scopes ? GB 3' - 8 1/2" This project has been designed by me, or under my supervision, in accordance with the 2009 International Building, Plumbing, and Mechanical Codes, the 2008 National Electrical Code, and applicable Federal, State and local laws, codes and regulations; and to the best of my knowledge and belief, these construction documents are in conformance therewith. RA404343 Registered Architect PA Reg. No. Date 12' - 0" 2' - 5 1/8" 8' - 6" 33' - 1 1/8" 5' - 0" 5' - 6" Respiratory Therapist Office GB 8' - 6" 1912 Physician Suite and Respiratory Therapy Reception MD Ofc 1908 GB 8' - 6" 3' - 8 7/8" GB Retail Pharmacy and Gift Shop 8' - 6" GB Pharmacist 1917 1915 Stress Test 1904 1900 9' - 6" 8' - 0" Pulmonary Function T Pat Tlt 9' - 0" 1911 1906 8' - 0" Bulk Storage Corridor 1918 1902 EKG, EMG, Holter 9' - 0" 1901 8' - 0" Nurse Station 1901a Men Women 1006 1005 Retail Dispensing 1916 1903 Check In Check Out Endless Mountains Health Systems 1552 8' - 0" 1543 8' - 0" 8' - 0" 1733 1730 T-2 Soiled Workroom 1530 8' - 0" 8' - 0" Soiled Holding Corridor 8' - 0" Elec 4 1807 9' - 6" 1526 Women's Lockers 1549 1527 Nuclear Medicine 8' - 0" 1806 8' - 0" Soiled Work Shower 8' - 0" 1529 Restricted Corridor 2' - 3 3/8" Soiled Workroom 1827 Patient Toilet Meds 8' - 0" 8' - 0" 1809 9' - 6" 8' - 0" 1602 1600 8' - 0" 8' - 0" 1532 Private 1715 Corridor 1808 Bone Density 8' - 0" 1720 1548 1544 Anesth PA License RA404343 Toilet Semirestricted Corridor Corridor 1032a Patient Toilet 1547 GB 1531 9' - 0" 8' - 0" T-3 Pathology Outpatient Lab Reception Seating 8' - 0" Men's Lockers 1539 Phlebotomy 8' - 0" 8' - 0" Restricted Corridor 9' - 0" Spec. Tlt 1821 1822 1554 1604 8' - 0" W. Randolph Cole, AIA Vestibule 8' - 0" 1736 Coats 1536 Substerile 1606 8' - 0" 1811 9' - 6" Lab Manager 8' - 0" Radiography Clean Workroom 1534 1607 2' - 3 3/8" T-4 1810 8' - 0" 1718 1734 Nurse/ MD Station O.R. 2 Orthopedics GB 1608 Microbiology Corridor O.R. 1 General 1535 Pat Tlt 1739 9' - 0" 8' - 0" Hskpg GB 9' - 0" GB 9' - 0" 9' - 0" 8' - 0" 1819 1812 Laboratory 8' - 0" 1545 9' - 0" 3' - 8 3/4" 1817 Staff Corridor 5' - 5" Staff Lounge 3' - 8 3/4" Corridor 1813 Rad/Fluor 14' - 0" GB 9' - 0" CT 5' - 5 1/8" 3' - 0" 8' - 0" 8' - 0" T-6/ Decontam 3' - 8 3/4" Clean Storage Staff Lounge 1818 10' - 0" ED Mgr 1814 3' - 8 3/4" 1816 On-call T-5/ Decontam Stair B 10' - 0" 10' - 2" 8' - 0" Exam Exam Exam Exam 1905 1907 1909 1910 EMHS Dispensing 1919 1 Phase 1 Main Level 1/8" = 1'-0" Project Number: Reviewed By: Date: Revision No. and Date: Exit and Delivery Vestibule SB08A Cole 09/19/2012 1920 RFI-085 Rev. 4 Dimension tolerance Rev. 4 RFI 178 General Ceiling Notes 04/24/2012 08/29/2012 09/19/2012 Ceiling Plan Legend 1. "Exposed Construction" Indicates no ceiling, exposed to deck, painted. 2x2 Acoustical Panel Ceiling 2. Center acoustical panels or grid in spaces unless otherwise indicated. 3. Sprinkler head locations are shown for coordination purposes only. Not all sprinkler heads are shown. Fire Suppression system installer shall coordinate sprinkler heads. In areas without suspended ceilings, coordinate locations of sprinkler heads with HVAC ducts, equipment, beams, columns, lights, and any other obstructions in accordance with NFPA 13. In areas with suspended ceilings, coordinate sprinkler mains, runs and sprinkler head locations with other work to insure ceiling heights, lighting, diffuser and other ceiling device locations are maintained as shown or as required to comply with applicable code requirements. Advise Architect of any conflicts which must be resolved prior to installation. 4. Light fixtures, fire protection devices and diffusers are shown for location and coordination purposes only. Refer to electrical and HVAC drawings for actual light fixture, diffuser and fire protection schedules. 5. Refer to electrical, HVAC and fire protection drawings for light fixtures, diffusers and fire protection devices in unfinished areas or areas with exposed structure. 6. Coordinate access panel locations with mechanical trades; submit proposed locations to Architect for approval. 2x4 Acoustical Panel Ceiling Gypsum Board Ceiling (Painted) GB Indicates Ceiling Type GB T AVC MY CR Gypsum Board Ceiling Tegular Edge Ceiling Tile Aluma Vault Ceiling Mylar Ceiling Tile Clean Room Ceiling Tile 12' - 0" Indicates Ceiling Height as Noted 7. All ceiling heights shall be 8'-0" unless noted otherwise. 8. All soffit heights shall be 7'-2" unless noted otherwise. Light Fixture Legend Recessed PR 2x2 1x4 6" Downlight 2x4 2x4 8" Downlight Wall Mounted 6' Linear Wall Mounted Fixture Sconce Drawing Name Surface Mounted 4' Shop Light Phase 1 Main Level Reflected Ceiling Plan 8' Shop Light Other Ceiling Exit Light Mechanical/Electrical Legend Diffuser Supply Return Linear Slot Diffuser Supply or Return Project North Drawing Number A-411 copyright 2011