Transcript
Request for Information Phase 1-RFI 219 Detailed, RFIs Grouped by RFI Number
4682 - Endless Mountains Health Systems Route 706 100 Hospital Way Montrose, PA 18801
Project # 4682 Tel: (570) 432-0109
Fax: (570) 287-0298
RFI #: Phase 1-RFI 219
Date Created: 1/29/2013
Answer Company
Answered By
Author Company
Stratton Brook Associates 244 Farms Village Road Post Office Box 576 West Simsbury CT, 06902
W. Randolph Cole
Sordoni Construction Services, Inc. Jeffrey Kiluk 45 Owen Street Forty Fort, PA 18704
Co-Respondent Mark Gendron
Author RFI Number Rado0063
Subject Electric Flush Valves vs Battery Cc:
Authored By
Discipline Plumbing
Company Name
Contact Name
G. R. Noto Electrical Const Rado Enterprises, Inc. Sordoni Construction Services, Inc. Hopson Specialty Systems Classic Fire Protection, Inc
A J Palazzari Corey Yule Joseph Homza Brian Lombardo Stacy Clum
Category Drawing Discrepancies Copies Notes 1 1 1 1 1
File 4682
Question Date Required: 2/5/2013 As per the approved plumbing fixture submittal, Rado is currently furnishing electric flush valves for Water Closets/Bed Pan Washers/Urinals. Would it be acceptable to switch to battery operated flush valves thus eliminating the need for required transformers? This would prevent shutting down multiple fixtures/transformers if a circuit needs to be worked on. Respective cut sheets are attached. Suggestion Answer Yes, switching to battery is acceptable.
Date Answered: 2/11/2013
Mark Gendron, PE Acorn 2/11/13
Prolog Manager
Printed on: 2/11/2013
SCS PA
Page 1
Model
8110/8111
Battery Powered Flushometers
t
Buy
Ac t •
n
om
C
plia
•
Ac t •
om
£ Model 8111 Low Consumption (1.6 gpf/6.0 Lpf) £ Model 8110 Water Saver (3.5 gpf/13.2 Lpf)
n
n
u
Flush Cycle
C
u
•
u
e r i ca Am
e r i ca Am
Description Exposed, Battery Powered, Sensor Operated G2® Model Water Closet Flushometer for floor mounted or wall hung top spud bowls.
Buy
u
n
t
OPTIMA SYSTEMS
plia
Specifications Quiet, Exposed, Diaphragm Type, Chrome Plated Closet Flushometer for either left or right hand supply with the following features: • PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass • Flex Tube Diaphragm designed for improved life and reduced maintenance • ADA Compliant OPTIMA Plus® Battery Powered Infrared Sensor for automatic “No Hands” operation • Infrared Sensor with Multiple-focused, Lobular Sensing Fields for high and low target detection • Latching Solenoid Operator • Engineered Metal Cover with replaceable Lens Window • User friendly three (3) second Flush Delay • Courtesy Flush® Override Button • Four (4) Size AA Batteries factory installed • “Low Battery” Flashing LED • Infrared Sensor Range Adjustment Screw • Initial Set-up Range Indicator Light (first 10 minutes) • 1” I.P.S. Screwdriver Bak-Chek® Angle Stop • Free Spinning, Vandal Resistant Stop Cap • Adjustable Tailpiece • High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex Coupling Nut • Spud Coupling and Flange for 1½” Top Spud • Sweat Solder Adapter with Cover Tube and Cast Set Screw Wall Flange • High Copper, Low Zinc Brass Castings for Dezincification Resistance • Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation • Flush Accuracy Controlled by CID™ Technology • Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX® Rubber Compound for Chloramine resistance • 100% of the energy used in manufacturing is offset with Renewable Energy Sources – Wind Energy
u u
Valve Body, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance with the applicable sections of ASSE 1037, ANSI/ASME A112.19.2. Installation conforms to ADA requirements.
u
Made with Renewable Energy
u
ADA Compliant Automatic Sloan G2 Optima Plus® Flushometers activate via multi-lobular sensor detection to provide the ultimate in sanitary protection and automatic operation. A battery powered infrared sensor sets the flushing mechanism after the user is detected and completes the flush when the user steps away.
Functional & Hygienic
Made with
Touchless, sensor operation eliminates the need for Renewable user contact to Energy help control the spread of infectious diseases. The G2 Optima Plus Flushometer is provided with an Override Button to allow a "courtesy flush" for individual user comfort.
u
Economical Sloan installed batteries speed installation and provide years of metered flushing to control the use of water and energy. Batteries can be changed without turning off the water.
Warranty 3 year (limited)
Special Finishes £ PB £ BN £ SF
Polished Brass (PVD Finish) Brushed Nickel (PVD Finish) Satin Chrome
See Accessories Section and OPTIMA Accessories Section of the Sloan catalog for details on these and other OPTIMA Plus® Flushometer variations.
This space for Architect/Engineer approval Job Name
Date
Model Specified
Quantity
Variations Specified Customer/Wholesaler Contractor Architect
G2 Optima Plus 8110 S.S. — Rev. 1a (06/11)
The information contained in this document is subject to change without notice.
Model
8110/8111 u
Description Exposed, Battery Powered, Sensor Operated G2® Model Water Closet Flushometer for floor mounted or wall hung top spud bowls.
u
Flush Cycle
2¼” MIN. (57 mm)
£ Model 8111 Low Consumption (1.6 gpf/6.0 Lpf) £ Model 8110 Water Saver (3.5 gpf/13.2 Lpf)
4 ¾” (121 mm)
5” (127 mm)
ELECTRICAL SPECIFICATIONS
u
u
Control Circuit Solid State 6 VDC Input 8 Second Arming Delay 3 Second Flush Delay
u
OPTIMA Sensor Type Active Infrared
u
OPTIMA Sensor Range Nominal 22” - 42” (559 mm -1067 mm), Adjustable ± 8” (203 mm)
Battery Type (4) AA Alkaline
16½” (419 mm)
u
Battery Life 3 Years @ 4,000 Flushes/Month
u
Indicator Lights Range Adjustment/Low Battery
u
Operating Pressure 15 - 100 psi (104 - 689 kPa)
u
Sentinel Flush Once Every 24 Hours After the Last Flush
C/L OF SUPPLY 1” I.P.S. SUPPLY (DN 25 mm)
11½” (292 mm)
C/L OF FIXTURE
C/L OF FIXTURE
OPERATION 1. A continuous, invisible light beam is emitted from the OPTIMA Plus Sensor.
2. As the user enters the beam’s effective range (22” to 42”) the beam is reflected into the OPTIMA Plus Scanner Window and transformed into a low voltage electrical circuit. Once activated, the Output Circuit continues in a “hold” mode for as long as the user remains within the effective range of the Sensor.
3. When the user steps away from the OPTIMA Plus Sensor, the circuit waits 3 seconds (to prevent false flushing) then initiates an electrical signal that operates the Solenoid. This initiates the flushing cycle to flush the fixture. The Circuit then automatically resets and is ready for the next user.
VALVE ROUGH-IN Typical Water Closet Installation
Alternate ADA Installation Lower water supply rough-in to 10” (254 mm) and mount grab bar at the 36” (914 mm) maximum allowed height.
Model 8110/8111
2¼” (57 mm) MIN.
11½” (292 mm)
FINISHED WALL
16½” (419 mm)
1” I.P.S. (25 mm DN) SUPPLY C/L OF FIXTURE
C/L OF WASTE FINISHED FLOOR
2¼” (57 mm) MIN. 36” (914 mm)
4¾” (121 mm) 10” (254 mm)
When installing the G2 Optima Plus in a handicap stall: Per the ADA Guidelines (section 604.9.4) it is recommended that the grab bars be split or shifted to the wide side of the stall. If grab bars must be present over the valve, use the Alternate ADA Installation as shown to the right.
FINISHED WALL
15” (381 mm)
18” (457 mm)
C/L OF WASTE FINISHED FLOOR
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com Copyright © 2011 Sloan Valve Company
G2 Optima Plus 8110 S.S. — Rev. 1a (06/11)
Model
BPW-8005
OPTIMA SYSTEMS Battery Powered Flushometers u u u
u
Description Exposed, Battery Powered, Sensor Activated G2® Model Bedpan Washer Water Closet Flushometer with Deoseptic Unit, for floor mounted or wall hung top spud bowls.
Flush Cycle £ Model BPW-8005-1.6 Low Consumption (1.6 gpf/6.0 Lpf) £ Model BPW-8005 Water Saver (3.5 gpf/13.2 Lpf)
Specifications Quiet, Exposed, Diaphragm Type, Chrome Plated Closet Flushometer for either left or right hand supply with the following features: • PERMEX™ Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass • Flex Tube Diaphragm designed for improved life and reduced maintenance • ADA Compliant OPTIMA Plus® Battery Powered Infrared Sensor for automatic “No Hands” operation • Infrared Sensor with Multiple-focused, Lobular Sensing Fields for high and low target detection • Latching Solenoid Operator • Engineered Metal Cover with replaceable Lens Window • User friendly three (3) second Flush Delay • Courtesy Flush™ Override Button • Four (4) Size AA Batteries factory installed • “Low Battery” Flashing LED • Infrared Sensor Range Adjustment Screw • Initial Set-up Range Indicator Light (first 10 minutes) • Chrome Plated Metal Handle Cap • 1” I.P.S. Screwdriver Bak-Chek® Angle Stop • Free Spinning, Vandal Resistant Stop Cap • Adjustable Tailpiece • High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex Coupling Nut • Spud Coupling and Flange for 1½” Top Spud • Sweat Solder Adapter w/Cover Tube and Cast Wall Flange w/Set Screw • High Copper, Low Zinc Brass Castings for Dezincification Resistance • Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation • Flush Accuracy Controlled by CID™ Technology • Diaphragm, Stop Seat and Vacuum Breaker molded from PERMEX™ Rubber Compound for Chloramine resistance • 100% of the energy used in manufacturing is offset with Renewable Energy Sources – Wind Energy Bedpan Washer Diverter Assembly with the following features: • Deoseptic Unit with 16 oz. (473 ml) Reservoir Bottle • Solid One-piece Body Construction • Solid Brass Spray Arm • Counter Balanced Pivot Assembly • Diverter Valve Wall Support Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037, ANSI/ASME A112.19.2.
u
u
u u
Special Finishes £ PB £ BN £ SF
Made with Renewable Energy
Polished Brass (PVD Finish) Brushed Nickel (PVD Finish) Satin Chrome
Automatic Sloan G2® Optima Plus® Flushometers activate via multi-lobular sensor detection to provide the ultimate in sanitary protection and automatic operation. A battery powered infrared sensor sets the flushing mechanism after the user is detected and completes the flush when the user steps away.
Functional & Hygienic Touchless, sensor operation eliminates the need for user contact to help control the spread of infectious diseases. The G2® Optima MadePlus with Energy Flushometer is provided with an Override Button to allowRenewable a "courtesy flush" for individual user comfort.
Economical Sloan installed batteries speed installation and provide years of metered flushing to control the use of water and energy. Batteries can be changed without turning off the water.
Warranty 3 year (limited)
See Accessories Section and OPTIMA Accessories Section of the Sloan catalog for details on these and other OPTIMA Plus® Flushometer variations.
This space for Architect/Engineer approval
Made with Renewable Energy
Job Name
Date
Model Specified
Quantity
Hecho con Energía Renovable
Variations Specified
G2 Optima Plus BPW-8005Spanish S.S. — Rev. 0 (10/10)
n plia
Customer/Wholesaler Contractor
t
om
C
Sloan Valve Company is buying renewable energy certificates tocon meet 100% of the company’s purchased Hecho Energía Renovable electricity use at its Franklin Park, Illinois facility.
•
Made with Renewable Energy
Ac t •
Buy
n
e r i ca Am
Architect The information contained in this document is subject to change without notice.
Model
OPERATION
BPW-8005 u u
Description Exposed, Battery Powered, Sensor Activated G2® Model Bedpan Washer Water Closet Flushometer with Deoseptic Unit, for floor mounted or wall hung top spud bowls.
1. A continuous, invisible light beam is emitted from the OPTIMA Plus Sensor.
Flush Cycle £ Model BPW-8005-1.6 Low Consumption (1.6 gpf/6.0 Lpf) £ Model BPW-8005 Water Saver (3.5 gpf/13.2 Lpf)
ELECTRICAL SPECIFICATIONS
u
u u
Control Circuit Solid State 6 VDC Input 8 Second Arming Delay 3 Second Flush Delay OPTIMA Sensor Type Active Infrared OPTIMA Sensor Range Nominal 22” - 42” (559 mm -1067 mm), Adjustable ± 8” (203 mm)
u
Battery Type (4) AA Alkaline
u
Battery Life 3 Years @ 4,000 Flushes/Month
u
Indicator Lights Range Adjustment/Low Battery
u
Operating Pressure 15 - 100 psi (104 - 689 kPa)
u
Sentinel Flush Once Every 24 Hours After the Last Flush
2. As the user enters the beam’s effective range (22” to 42”) the beam is reflected into the Plus Scanner OPTIMA Window and transformed into a low voltage electrical circuit. Once activated, the Output Circuit continues in a “hold” mode for as long as the user remains within the effective range of the Sensor.
3. When the user steps away from the OPTIMA Plus Sensor, the circuit waits 3 seconds (to prevent false flushing) then initiates an electrical signal that operates the Solenoid. This initiates the flushing cycle to flush the fixture. The Circuit then automatically resets and is ready for the next user.
ROUGH-IN
2-1/4" MIN. (57 mm)
4-3/4" (121 mm) 5" (127 mm) 1" I.P.S. SUPPLY (DN 25 mm)
34-3/8" (873 mm)
13-3/4" (349 mm)
9-1/2" (241 mm)
TOP OF FIXTURE
CENTER LINE OF WASTE FIN. WALL
When installing the G2® Optima Plus in a handicap stall: Per the ADA Guidelines (section 604.9.4) it is recommended that the grab bars be split or shifted to the wide side of the stall. FIN. FLOOR
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com Copyright © 2010 Sloan Valve Company
G2 Optima Plus BPW-8005 S.S. — Rev. 0 (10/10)
Model
8186
Battery Powered Flushometers
Buy
Ac t •
t
n
n
om
C
plia
•
Ac t •
om
plia
n
Specifications Quiet, Exposed, Diaphragm Type, Chrome Plated Urinal Flushometer for either left or right hand supply with the following features: • PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass • Flex Tube Diaphragm designed for improved life and reduced maintenance • ADA Compliant OPTIMA Plus® Battery Powered Infrared Sensor for automatic “No Hands” operation • Infrared Sensor with Multiple-focused, Lobular Sensing Fields for high and low target detection • Latching Solenoid Operator • Engineered Metal Cover with replaceable Lens Window • Courtesy Flush® Override Button • Four (4) Size AA Batteries factory installed • “Low Battery” Flashing LED • Infrared Sensor Range Adjustment Screw • Initial Set-up Range Indicator Light (first 10 minutes) • ¾” I.P.S. Screwdriver Bak-Chek® Angle Stop • Free Spinning, Vandal Resistant Stop Cap • Adjustable Tailpiece • High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex Coupling Nut • Spud Coupling and Flange for ¾” Top Spud • Sweat Solder Adapter with Cover Tube and Cast Set Screw Wall Flange • High Copper, Low Zinc Brass Castings for Dezincification Resistance • Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation • Flush Accuracy Controlled by CID Technology • Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX® Rubber Compound for Chloramine resistance • 100% of the energy used in manufacturing is offset with Renewable Energy Sources – Wind Energy Valve Body, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance with the applicable sections of ASSE 1037, ANSI/ASME A112.19.2. Installation conforms to ADA requirements.
u
n
£ Model 8186-1.0 Low Consumption (1.0 gpf/3.8 Lpf) £ Model 8186 Water Saver (1.5 gpf/5.7 Lpf)
C
u
Flush Cycle
•
u
e r i ca Am
e r i ca Am
Description Exposed, Battery Powered, Sensor Operated G2® Model Urinal Flushometer.
Buy
u
t
OPTIMA SYSTEMS
Made with Renewable Energy
u u
u
u
ADA Compliant Automatic Sloan G2 Optima Plus® Flushometers activate via multi-lobular sensor detection to provide the ultimate in sanitary protection and automatic operation. A battery powered infrared sensor sets the flushing mechanism after the user is detected and completes the flush when the user steps away.
Functional & Hygienic with Touchless, sensor operation eliminates the need for Renewable userMade contact to Energy help control the spread of infectious diseases. The G2 Optima Plus Flushometer is provided with an Override Button to allow a "courtesy flush" for individual user comfort.
Economical Sloan installed batteries speed installation and provide years of metered flushing to control the use of water and energy. Batteries can be changed without turning off the water.
u
Warranty 3 year (limited)
Special Finishes £ PB £ BN £ SF
Polished Brass (PVD Finish) Brushed Nickel (PVD Finish) Satin Chrome
See Accessories Section and OPTIMA Accessories Section of the Sloan catalog for details on these and other OPTIMA Plus® Flushometer variations.
This space for Architect/Engineer approval Job Name
Date
Model Specified
Quantity
Variations Specified Customer/Wholesaler Contractor Architect
G2 Optima Plus 8186 S.S. — Rev. 0 (04/12)
The information contained in this document is subject to change without notice.
Model
8186 u
Description Exposed, Battery Powered, Sensor Operated G2® Model Urinal Flushometer.
u
Flush Cycle £ Model 8186-1.0 Low Consumption (1.0 gpf/3.8 Lpf) £ Model 8186 Water Saver (1.5 gpf/5.7 Lpf)
ELECTRICAL SPECIFICATIONS
u
Control Circuit Solid State 6 VDC Input 8 Second Arming Delay 24 Hour Sentinel Flush
u
OPTIMA Sensor Type Active Infrared
u
OPTIMA Sensor Range Nominal 15” - 30” (381 mm - 762 mm), Adjustable ± 8” (203 mm)
u
Battery Type (4) AA Alkaline
u
Battery Life 3 Years @ 4,000 Flushes/Month
u
Indicator Lights Range Adjustment/Low Battery
u
Operating Pressure 15 - 100 psi (104 - 689 kPa)
u
Sentinel Flush Once Every 24 Hours After the Last Flush
OPERATION 1. A continuous, invisible light beam is emitted from the OPTIMA Plus Sensor.
2. As the user enters the beam’s effective range (15” to 30”) the beam is reflected into the OPTIMA Plus Scanner Window and transformed into a low voltage electrical circuit. Once activated, the Output Circuit continues in a “hold” mode for as long as the user remains within the effective range of the Sensor.
3. When the user steps away from the OPTIMA Plus Sensor, the Sensor initiates an electrical signal that operates the Solenoid. This initiates the flushing cycle to flush the fixture. The Circuit then automatically resets and is ready for the next user.
VALVE ROUGH-IN Typical Urinal Installation Model 8186
¾” I.P.S. (20 mm DN) SUPPLY
2¼” (57 mm) MIN.
11½” (292 mm)
16½” (419 mm)
C/L OF FIXTURE
4¾” (121 mm)
Note: Lens Deflector no longer needed for targeting children or wheel chair users.
FINISHED WALL
FINISHED FLOOR
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com Copyright © 2012 Sloan Valve Company