Preview only show first 10 pages with watermark. For full document please download

Rg-213/u 50 Ohms Coaxial Cable Construction Properties

   EMBED


Share

Transcript

RG-213/U 50 Ohms Coaxial Cable CONSTRUCTION PROPERTIES Inner Conductor Min. Bending Radius: 36.0 mm Max. Pulling Tension 746 N Crush resistance of cable (load of 700N) <1 % Insulation Outer Conductor Rated Temperature Storage/operating temperature Jacket -20~+75 ℃ Outdoor Installation ELECTRICAL CHARACTERISTICS PHYSICAL SPECIFICATIONS Center Conductor Conductor Dia.(+/-0.015mm) Min. Break Strength (N) Insulation Insulation Dia.(+/-0.10mm) Characteristic Impedance 50 +-3ohm 2.25 (7/0.752) Capacitance 94 ±3pF/m 1430 Velocity Ratio Stranded Bare Copper Solid Polyethylene 7.24 > 66 % DC Resistance: Centre Conductor < 5.90 ohm/km DC Resistance: Outer Conductor < 4.30 ohm/km Color Neutral Centricity (%) ≥ 90 Peak Power rating 20 to 100N @ 200mm Cut Off Frequency Adhesion Insulation Resistance Outer Conductor Bare Copper Braid Conductor Dia.(+/-0.01mm) 0.18 No. of Wires 192 Coverage (+/-3%) 95 Outer Jacket 16.00 Kw 13.50 GHz > 5,000 МΩ·km Dielectric Strength 2500 VAC Voltage Withstand 5000 VDC Screening Factor at 1 - 1000MHz > 90 dB PVC Outer Dia (+/-0.20mm) 10.20 Tensile strength ≥ 10.5 N/mm2 Elongation at break ≥ 150 % Adhesion -20 ℃ 150 to 250N @ 200mm Frequency Attenuation (at 20 ℃) 1 MHz 0.20 dB/100Ft 10 MHz 0.60 dB/100Ft 50 MHz 1.30 dB/100Ft 100 MHz 1.90 dB/100Ft 200 MHz 2.90 dB/100Ft Printing 400 MHz 4.50 dB/100Ft 500 MHz 4.75 dB/100Ft Shireen RFC ® RG213/U 50 ohms Cables ww/yy 700 MHz 6.50 dB/100Ft + footage marking 900 MHz 7.60 dB/100Ft 1000 MHz 8.00 dB/100Ft 3000 MHz 18.50 dB/100Ft