MODEL SPECIFICATIONS Backup Mode (head and shelves)
Model Appliance Useable Disk Cache Capacity Appliance Logical Data Size in Cache
(f)
(g, h)
Appliance Cloud Capacity (a, h) Appliance Logical Data Size in Cloud (g) Additional Shelves Supported Max System Useable Disk Cache Capacity Max System Logical Data Size in Cache Max System Cloud Capacity
(g)
(a, h)
Max System Logical Data Size Cloud (g)
Archival Mode (head only)
WWA730
WWA2030
WWA3030
WWA730
WWA2030
WWA3030
8TB
16TB
32TB
8TB
16TB
32TB
240TB
480TB
960TB
Up to 333M files
Up to 666M files
Up to 1333M files
40TB
80TB
160TB
Up to 2.5PB
Up to 5PB
Up to 10PB
1200TB
2400TB
4800TB
Up to 2.5PB
Up to 5PB
Up to 10PB
None
2
2
None
None
None
8TB
48TB
96TB
8TB
16TB
32TB
240TB
1440TB
2880TB
Up to 333M files
Up to 666M files
Up to 1333M files
40TB
240TB
480TB
Up to 2.5PB
Up to 5PB
Up to 10PB
1200TB
7200TB
14400TB
Up to 2.5PB
Up to 5PB
Up to 10PB
Raid Protection Level
RAID-6 (c)
Network Integration
6 x 1GbE
Maximum Ingress Throughput, Aggregate GB/Hr (d)
Model
2000 (e)
RAID-6 (c)
2 x 1GbE onboard, choose one of (4 x 1GbE or 2 x 10GbE) 2500 (e)
6 x 1GbE
3000 (e)
2 x 1GbE onboard, choose one of (4 x 1GbE or 2 x 10GbE)
350 (e)
350 (e)
350 (e)
Virtual WWA110
Virtual WWA210
Virtual WWA410
Virtual WWA810
Virtual WWA1610
Up to 2TB
Up to 4TB
Up to 8TB
Up to 16TB
Up to 32TB
Logical Data Size in Cache (30x dedupe)
60TB
120TB
240TB
480TB
960TB
Licensed Cloud Capacity
8TB
20TB
40TB
80TB
160TB
Useable Disk Cache Capacity (f)
(a)
Logical Data Size in Cloud (30x dedupe)
240TB
600TB
1200TB
2400TB
4800TB
Raid Protection Level
Customer provisioned (b)
Customer provisioned (b)
Customer provisioned (b)
Customer provisioned (b)
Customer provisioned (b)
Network Integration
2 x 1GbE
2 x 1GbE
2 x 1GbE
2 x 1GbE or 2 x 10GbE
2 x 1GbE or 2 x 10GbE
800
800
800
1000
1000
Maximum Ingress Throughput, Aggregate GB/Hr (d)
(a) Base-2 capacity (1TB = 1024*1024*1024*1024 bytes) (b) Any customer provisioned RAID level that is valid and supported by VMWare ESXi 4.x or higher (c) Local storage with the SteelStore appliance only. (Excludes cloud storage). (d) Max LAN throughput can be expected upto the amount listed, requires 10GE in those models that support it (e) Requires WWOS 3.0.x S/W (f) Base-10 capacity (1TB = 1000*1000*1000*1000 bytes) (g) Backup mode TB assuming 30X dedupe, Archive mode assumes 50% compression (h) Archival mode # of files; Capacities assume 100Mbyte average file size
SPECIFICATION SHEET: Riverbed SteelStore
PHYSICAL SPECIFICATIONS Model
WWA730
WWA2030
Memory
24GB
48-96GB
96-192GB
Front Swappable Drives (i)
7X2TB
12X2TB
12X4TB
Profile
WWA3030
WWS1001
2U
Connectivity
WWS1002 2U n/a
12*2TB
2 * 1G Copper NIC
12*4TB 2 * 6G SAS
4 * 1GE Copper or 2 * 10GE Fibre w/ SR or LR SFP
n/a
Redundant Power Supplies
Yes
Yes
Power [Watts] (Typical)
338
270
1154 BTU/hr (338W) typical
920 BTU/hr, 270W (typical operating conditions @ 110VAC)
5° to 35°C Operating, 1° to 50°C Non-operating
5º to 40ºC (35ºC max. above 2,000m) Operating, -40º to 60ºC Non-operating
20% to 80% non-condensing Operating, 8% to 80% non-condensing Non-Operating
20% to 80% non-condensing Operating, 5% to 80% non-condensing Non-operating
Sound Power Operating less than or equal to LWAd 7.0 Bels
Sound Power Operating