Preview only show first 10 pages with watermark. For full document please download

Riverbed® Steelstore™

   EMBED


Share

Transcript

SPECIFICATION SHEET: Riverbed SteelStore RIVERBED STEELSTORE ® ™ (Formerly Whitewater) MODEL SPECIFICATIONS Backup Mode (head and shelves) Model Appliance Useable Disk Cache Capacity Appliance Logical Data Size in Cache (f) (g, h) Appliance Cloud Capacity (a, h) Appliance Logical Data Size in Cloud (g) Additional Shelves Supported Max System Useable Disk Cache Capacity Max System Logical Data Size in Cache Max System Cloud Capacity (g) (a, h) Max System Logical Data Size Cloud (g) Archival Mode (head only) WWA730 WWA2030 WWA3030 WWA730 WWA2030 WWA3030 8TB 16TB 32TB 8TB 16TB 32TB 240TB 480TB 960TB Up to 333M files Up to 666M files Up to 1333M files 40TB 80TB 160TB Up to 2.5PB Up to 5PB Up to 10PB 1200TB 2400TB 4800TB Up to 2.5PB Up to 5PB Up to 10PB None 2 2 None None None 8TB 48TB 96TB 8TB 16TB 32TB 240TB 1440TB 2880TB Up to 333M files Up to 666M files Up to 1333M files 40TB 240TB 480TB Up to 2.5PB Up to 5PB Up to 10PB 1200TB 7200TB 14400TB Up to 2.5PB Up to 5PB Up to 10PB Raid Protection Level RAID-6 (c) Network Integration 6 x 1GbE Maximum Ingress Throughput, Aggregate GB/Hr (d) Model 2000 (e) RAID-6 (c) 2 x 1GbE onboard, choose one of (4 x 1GbE or 2 x 10GbE) 2500 (e) 6 x 1GbE 3000 (e) 2 x 1GbE onboard, choose one of (4 x 1GbE or 2 x 10GbE) 350 (e) 350 (e) 350 (e) Virtual WWA110 Virtual WWA210 Virtual WWA410 Virtual WWA810 Virtual WWA1610 Up to 2TB Up to 4TB Up to 8TB Up to 16TB Up to 32TB Logical Data Size in Cache (30x dedupe) 60TB 120TB 240TB 480TB 960TB Licensed Cloud Capacity 8TB 20TB 40TB 80TB 160TB Useable Disk Cache Capacity (f) (a) Logical Data Size in Cloud (30x dedupe) 240TB 600TB 1200TB 2400TB 4800TB Raid Protection Level Customer provisioned (b) Customer provisioned (b) Customer provisioned (b) Customer provisioned (b) Customer provisioned (b) Network Integration 2 x 1GbE 2 x 1GbE 2 x 1GbE 2 x 1GbE or 2 x 10GbE 2 x 1GbE or 2 x 10GbE 800 800 800 1000 1000 Maximum Ingress Throughput, Aggregate GB/Hr (d) (a) Base-2 capacity (1TB = 1024*1024*1024*1024 bytes) (b) Any customer provisioned RAID level that is valid and supported by VMWare ESXi 4.x or higher (c) Local storage with the SteelStore appliance only. (Excludes cloud storage). (d) Max LAN throughput can be expected upto the amount listed, requires 10GE in those models that support it (e) Requires WWOS 3.0.x S/W (f) Base-10 capacity (1TB = 1000*1000*1000*1000 bytes) (g) Backup mode TB assuming 30X dedupe, Archive mode assumes 50% compression (h) Archival mode # of files; Capacities assume 100Mbyte average file size SPECIFICATION SHEET: Riverbed SteelStore PHYSICAL SPECIFICATIONS Model WWA730 WWA2030 Memory 24GB 48-96GB 96-192GB Front Swappable Drives (i) 7X2TB 12X2TB 12X4TB Profile WWA3030 WWS1001 2U Connectivity WWS1002 2U n/a 12*2TB 2 * 1G Copper NIC 12*4TB 2 * 6G SAS 4 * 1GE Copper or 2 * 10GE Fibre w/ SR or LR SFP n/a Redundant Power Supplies Yes Yes Power [Watts] (Typical) 338 270 1154 BTU/hr (338W) typical 920 BTU/hr, 270W (typical operating conditions @ 110VAC) 5° to 35°C Operating, 1° to 50°C Non-operating 5º to 40ºC (35ºC max. above 2,000m) Operating, -40º to 60ºC Non-operating 20% to 80% non-condensing Operating, 8% to 80% non-condensing Non-Operating 20% to 80% non-condensing Operating, 5% to 80% non-condensing Non-operating Sound Power Operating less than or equal to LWAd 7.0 Bels Sound Power Operating