Preview only show first 10 pages with watermark. For full document please download

Rj45-patch Cable Cat.7, 600 Mhz, 10 Gbit/s Corning

   EMBED


Share

Transcript

Datasheet 7501 3000/x,xD1C1 RJ45-patch cable Cat.7, 600 MHz, 10 GBit/s Corning FutureComTM S/FTP flex/26 + RJ45-connector Stewart SS-39200 Application  as patch cables in patch panels and appliance connection boxes for networks to 10 GBit/s Features and Design        Class EA, 500 MHz patch cable, 10 GBit/s PoE fit + after IEEE 802.3 at 2 x Stewart SS-39200 RJ45 plug STP, shielded, IEC 60603-7 Corning FutureComTM S/FTP-cable Li-02YSCH (4x2x0,42L PiMF FRNC) Wiring 1:1 after T568B Anti-kink sleeve with handle protection Length from 0,5m to 50m (The length marking is not verifiable. The tolerance is – 1% / +0,04m. It is not proided for testing the specified and calculated in the delivery documentation actual delivery lenght) Available colors Item number color 7501 3000/x,xD1C1 gray 7511 3000/x,xD1C1 yellow 7521 3000/x,xD1C1 green 7531 3000/x,xD1C1 blue 7551 3000/x,xD1C1 red 7581 3000/x,xD1C1 black 7591 3000/x,xD1C1 white x,x is a placeholder for the length 2016-11-24 11:09 | © CobiNet Fernmelde- & Datennetzkomponenten GmbH | Druckfehler, Irrtümer und technische Änderungen vorbehalten 1 Datasheet 7501 3000/x,xD1C1 Technische Daten FutureComTM S/FTP flex/26 Construction and materials of the cable             Cable (componente) according to standard Cat.7 Cable type.........................................................................................................................S/FTP Cord................................................................................Cu-Litze, bright Ø 0,42 mm (AWG 27/7) Isolation................................................................................Foam-Skin polyethylen, Ø 0,98 mm Standing element.............................................................................................2 wires to the pair Pair shielding...................................................................aluminium coated plastic composite fim Standing............................................................................................................................4 pair Braided shield....................................................................................................CU-weave tinned Cable sheath............................................................................................................LSHF (FRNC) Outside diameter (guideline).............................................................................................5,8 mm Copper content............................................................................................................20 kg/km Weight.........................................................................................................................42 kg/km Mechanical values for cable Bending radius  Operation................................................................................................................≥ 40 mm  Installation...............................................................................................................≥ 46 mm  Tensile load.......................................................................................................................186 N  Chemical properties  Conform to RoHS 2011/65/EG Fire behavior  Cable  Flame retardancy.........................................................................................afer IEC 60332-1  Minimale smoke...........................................................................after IEC 61034, EN 61034  Non-corrosive fire gases....................................after IEC 60754-2, EN 50267, VDE 0482-267  Fire load..............................................................................................................349 MJ/km  Fire load.........................................................................................................0,097 kWh/km 2016-11-24 11:09 | © CobiNet Fernmelde- & Datennetzkomponenten GmbH | Druckfehler, Irrtümer und technische Änderungen vorbehalten 2 Datasheet 7501 3000/x,xD1C1 Climate area In the resting state.......................................................................-20 to +60 °C (-4 to 140 °F)  In the agitated state......................................................................0 to +50 °C (32 to 122 °F)  Electrical values...................................................................................................20±5°C (68±41°F) Loop resistance ≤ 340 Ω/km Resistance unbalance ≤ 2% Insulation resistance (500 V) > 5000 MΩ*km Capacity at 800 Hz Nom. 43 nF/km Impedance (1 – 100) Mhz 100 ± 15 Ω Relative propagation velocity ca. 78 % Signal Propagation time 4,3 ns/100m Skew 10 ns/100m Test voltage Coupling attenation (DC, 1min) vein/vein and vein/shield 1000 V at 10 Mhz < 10 mΩ/m 92 dB 2016-11-24 11:09 | © CobiNet Fernmelde- & Datennetzkomponenten GmbH | Druckfehler, Irrtümer und technische Änderungen vorbehalten 3 Datasheet 7501 3000/x,xD1C1 RJ45-connector Stewart SS-39200 Application The RJ45-connector Stewart SS-39200 is compatible with all patch panels, outlets, etc.. The RJ45-connector suitable for service neutral cabling and supports 10-GBit-Ethernet. Features and Design       The patch cable FutureCom with Stewart SS-39200 connector is suitable for transmission lines (channellink) to Class EA, 250 MHz, 10GBit´s PoE fit after IEEE 802.3 af and PoE+ after IEEE 802.3 at stable, compact and fully enclosed polycarbonate housing Gilded RJ45-contact area Cable feed on plug straight Modular Plug (component) prepared using standart Cat 6A Technical specifications Mechanical values      Material  RJ45-contacte...........................................................Spring steel, gold-plated contact surface  LSA-contacte......................................................................................................CuSn, tinned Permissible wire diameter, wire......................................................................AWG 24 to AWG 27 Permissible insulation diameter..........................................................................0,94 to 1,07 mm Min. mating cycles after ISO/IEC 11801.........................................................................min. 200 Dimensions  Width....................................................................................................................13,71 mm  Height.......................................................................................................................6,7 mm  Depth......................................................................................................................42,4 mm Transmission technical and electrical values       Transmission path (channel-Link) to Class EA, 500MHz, 10 GBit´s PoE compatible with IEEE 802.3 af and PoE+ according toIEEE 802.3 at Dielectric strength according to IEC 60603-7.............................................500 V AC / one minute between adjacent contacts Dielectric strength according to IEC 60603-7...........................................1500 V AC / one minute between contact and screen Insulation resistance according to IEC 60603-7................................................>100MΩ (100 VDC) Contact resistance according to IEC 60603-7.................................................................<70 mΩ Climate area Use in dry or damp rooms without condensation.  Operating temperature range...........................................................-25 to +60 °C (-13 to 140 °F) 2016-11-24 11:09 | © CobiNet Fernmelde- & Datennetzkomponenten GmbH | Druckfehler, Irrtümer und technische Änderungen vorbehalten 4 Datasheet 7501 3000/x,xD1C1 Standardize TIA/EIA-568-C.2 (2009-08) Balanced Twisted-Pair Telecommunications Cabling and Components Standards 2016-11-24 11:09 | © CobiNet Fernmelde- & Datennetzkomponenten GmbH | Druckfehler, Irrtümer und technische Änderungen vorbehalten 5