Preview only show first 10 pages with watermark. For full document please download

Rl-dm4000+ 4 Input Dvb-t Encoder - Digi

   EMBED


Share

Transcript

ZyCast R Radio Frequency Range digi-MOD RL-DM4000+ www.digi-modbyzycast.com RL-DM4000+ 4 Input DVB-T Encoder / Modulator User Guide and Install Manual Table of Contents Safety Precautions 2 Package Contents 2 Product Description 2 Installation 4 Hardware Installations and Connections 4 Device Programming and Setup 4 Connecting to the GUI Interface 4 Encoder Programming and Setup via GUI Interface 5 Common Setup 6 RF Setup 6 Encoder Setup 7 Web Management 8 Administration 9 Saving your Front Panel LCD Encoder Menu Map Modulator via Front Panel LCD 10 11 Screen Views 11 Common Setup 11 RF Setup 12 Encoder Setup 12 Network Setup 13 Installing Multiple Encoders in the Same Installation (Stacking) 14 Safety Precautions The presence of this symbol is to alert the installer and user to the presence of uninsulated dangerous voltages within the product’s enclosure that may be of sufficient magnitude to produce a risk of electric shock. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS DEVICE TO RAIN OR MOISTURE. DO NOT OPEN THE UNIT. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. • Do not apply power to the unit until all connections have been made, all components have been installed and all wiring has been properly terminated. • Do not terminate, change or uninstall any wiring without first disconnecting the unit’s power adapter from the device. • This device is supplied with the appropriately rated power supply. The use of any other power supply could cause damage and invalidate the manufacturer’s warranty. • Do not connect the power cord to the device if the power cord is damaged. • Do not cut the power cord. • Do not plug the power cord into an AC outlet until all cables and connections to the device have been properly connected. • The device should be installed in an environment consistent with its operating temperature specifications. Placement next to heating devices and ducts is to be avoided as doing so may cause damage. The device should not be placed in areas of high humidity. • Do not cover any of the device’s ventilation openings. • Do not cover or obstruct the device’s fan or fan openings. • If the device has been in a cold environment allow it to warm to room temperature for at least 2 hours before connecting to an AC outlet. Package Contents This package contains: • One RL-DM4000+ Encoder / Modulator • One power cable • One installation / configuration manual Inspect the package before starting installation to ensure there is no damage and all supplied contents are present. Contact your distributor or dealer should the device be damaged or package contents are incomplete. Product Description resi-linx digi-MOD Series Encoder/ Modulators provides a DVB-T output stream - making it ideal for any Commercial RF Network. The high quality design allows for watching action packed movies and sports channels on any TV. The space saving design delivers up to 4 High Quality DVB-T channels in a single 1RU space. • Front panel LCD Display for easy installation • Selectable Constellation • LCN MODE • Closed Captioning Support • 4 Composite inputs • 100dB Output • MPEG2 Video Output • Rack mountable 1RU height RL-DM4000+ User Guide and Install Manual Page 2 Specification VIDEO INPUTS (VIDEO BY PRIORITY) Composite CVBS (RCA) AUDIO INPUTS Audio Inputs L/R (RCA) VIDEO ENCODER Mode MPEG-2 Video Resolutions 576p, 576i, 480p, 480i AUDIO Encoder Audio Compression MPEG-1 Layer II RF DVB-T Support Frequency Channel Plan - Varies by Country RF Channel Output 4 multiplexed on to 1 x RF Output Channels Constellation 64QAM (16QAM) Bandwidth 7 MHz RF Level Output 100dB MER > 40dB Typical FEC 1/2, 2/3, 3/4, 5/6, 7/8 Guard Interval 1/4, 1/8, 1/16, 1/32 OFDM 8K (2K) Attenuation 1-20dB (1dB steps) RF Output "F" - Female 75 ohm Closed Captioning Control By Selection (use of CVBS Input) Management / Control Front Panel LCD Control Full Support (Up/Doen/OK Buttons) GUI IE9, Firefox, Chrome, Safari Password Protected Front Panel, GUI General Rack Mountable (1RU) 482.7mm x 240mm x 44.4mm - 19" EIA Standard Internal Fan Cooled Dual Internal LCD Front Panel Dual Line, Scrolling Display **Subject to change without notice RL-DM4000+ User Guide and Install Manual Page 3 Installation System Installer must adhere to Article 820-40 of the NEC that provides guidelines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as possible. UNPACKING AND INSPECTION Each unit is shipped factory tested. Ensure all items are removed from the container prior to discarding any packing material. Thoroughly inspect the unit for shipping damage with particular attention to connectors and controls. If there is any sign of damage to the unit or damaged or loose connectors contact your distributor immediately. Do not put the equipment into service if there is any indication of defect or damage. Hardware Installations and Connections It is highly recommended that quality cables and connectors be used for all video and audio source connections. 1. The unit is designed to be rack mounted in a standard EIA 19” rack. 2. The unit comes standard with Composite video inputs. Use a 75Ω coaxial cable with RCA connectors to connect the video source (e.g., CATV, DVD, VCR, Camera) to the unit’s CVBS port (IN1…IN2, IN3, IN4 etc depending on your model). Repeat this step for each video source connection. 3. Composite Audio inputs: Connect A/V audio input (Left / Right Audio) use RCA cables to connect the audio source to the red / white AUDIO L and AUDIO R INPUT jacks (IN1…IN2, IN3, IN4 depending on your model). Repeat this step for each audio source connection. 4. Be sure the video and audio connections for each source are consistent with the unit’s inputs (IN1…IN2, IN3, IN4 depending on your model). 5. Use a quality 75Ω coaxial cable with “F” connectors from the unit’s RF OUT jack to the distribution system (combiner or reverse splitter) or directly to a television. 6. Connect the included power cord to the unit’s POWER plug. 7. Connect the power cord to an appropriately rated AC power outlet. Device Programming and Setup To setup and program the Encoder you can use the GUI interface or the LCD Front Panel. Connecting to the GUI Interface 1. Connect an Ethernet cable directly (no Cross Over cable required) to the Web Management Port on the rear panel of the encoder or connect the Ethernet cable to an Ethernet switch. Connect an Ethernet Cable to your PC. 2. Using a Windows-based PC Select Windows Icon 3. Go to My Computer 4. Select Network 5. Allow UPnP to locate and list the device(s) in the right panel 6. Right Click and Select “View device Webpage”. RL-DM4000+ User Guide and Install Manual NOTE: For Setup Using Front Panel LCD: Go to page 11 in this manual. Page 4 Encoder Programming and Setup via GUI Interface After connecting the device to the “Web Management” port located on the rear of the device and locating the device via the ‘Network’ tool in ‘My Computer’ STEP 1: Right Click and Select “View device Webpage”. Overview Page Welcome page showing overview status of the Encoder when fully functioning. Alternate between viewing status of RF Output 1 and RF Output 2 by selecting the RF Output section of the device you want to monitor. STEP 2: Login Select Common Setup Once the Common Setup Tab is selected you will be prompted to enter the user name and password for device: Default User Name: admin Default Password: Admin123 NOTE: Local Save Once all parameters are set you are required to do a Local Save. Notes on Changes: Changes made to an individual setup tab may require the installer to perform a Local Save AND Upload and Reboot to the device if you are only making changes to one parameter to the encoder. Example: Installer is required to change only the output channel for the device (No other changes to the device are not required). Once the channel has been changed, the installer is required to perform 1. Local Save and 2. Upload and Reboot. RL-DM4000+ User Guide and Install Manual Page 5 STEP 3: Common Setup Tab Common Setup: Use the Common Setup Page to set the Output channel, Attenuation, LCN Mode, and Device Address. STEP 4: RF Setup Use the RF Setup Page to setup each RF Output. Select RF Output 1 or RF Output 2. Select and set the required parameters you require for your installation. RL-DM4000+ User Guide and Install Manual Page 6 STEP 5: Local Save Once all parameters are set you are required to do a Local Save. STEP 6: Encoder Setup NOTE: There is an Encoder tab present for each input on the device. Select the Encoder 1, 2, 3, 4 tab to program an individual encoder. Select and change all desired parameters. STEP 7: Local Save for each Encoder tab Once all parameters are set you are required to do a Local Save on EACH Encoder Tab where changes were performed Note: Local Save function will indicate the local change made IMPORTANT NOTE: Upload and Reboot after all changes have been made and a Local Save performed RL-DM4000+ User Guide and Install Manual Ensure all Encoder changes have been locally saved before performing Step 9. Page 7 STEP 8: Upload and Reboot Once you have set all the encoder settings and performed a Local Save for each encoder Select “Upload and Reboot” after you have saved all your Local changes on each Tab. This function will upload and save all parameters set in the Common, RF, and Encoder sections of the device. We highly recommend you save your encoder configuration files. See Administration tab for how to back you device settings. STEP 9: Web Management Tab Use the Network Setup Tab to configure the device’s IP address, Subnet Mask, Gateway, Enable/Disable DHCP, and set Host Name. STEP 10: Save Network Configuration Save Config: Once all parameters are set you are required to select Save Config. This function will reboot and save the changes setting for the Network Configuration. RL-DM4000+ User Guide and Install Manual NOTE: Only the Network Configuration changes will be saved. Page 8 STEP 11: Administration Administration Page Functions Actions Reboot Reboot device. All unsaved settings will be lost. Reset to Default Reset all settings back to original factory settings Backup Download all settings of device Upload Upload a saved config file New Password Create and save new password for GUI STEP 13: If required, change GUI Password and Submit. This password is for access to the GUI only. The LCD front Panel Password will not be changed and is set to prevent unauthorized users access to your device. NOTE: When setting a new password you must use the ‘Submit’ button. Saving your configuration files To upload a configuration file- simply click “Choose File” then locate the file you want to upload. Click “Upload” to install the configuration files. This function is helpful to the installer when installing a large number of encoders in a single system. RL-DM4000+ User Guide and Install Manual IMPORTANT NOTE: We highly recommend you save your encoder configuration files. Simply Click the “Backup” button and the config files will be saved to your computer. Page 9 Front Panel LCD Encoder Menu Map COMMON SETUP Output Channel Attenuation LCN Mode Device Address Default Configuration Back to Main RF SETUP Select RF Enable RF Constellation FEC Guard Interval OFDM RF Output Cell ID TS ID Network ID Org Network ID Network Name Back to Main ENCODER SETUP Select Encoder Video Format Program Num Channel Name Provider Name LCN Aspect Ratio Brightness Contrast Saturation Hue Sharpness Back to Main WEB MANAGEMENT SETUP DHCP IP Address Subnet Mask Gateway Back to Main EXIT RL-DM4000+ User Guide and Install Manual Page 10 Modulator Configuration via Front Panel LCD Once the encoder is powered up it will go through its initial booting process. Once the unit has completed its initial “Booting” up process the LCD will display IN-1..., Bit Rate information, Channel-1...., and other information in the LCD Display Window. When visible the unit is ready for programming or operation. The LCD will display data as it cycles through the available information. SCREEN VIEWS 1. Inputs, Mbps, Channel Names, Video Output Type, Audio Output type IN-1 6.796Mbps CHANNEL-1 IN-2 6.796Mbps CHANNEL-2 MPEG2 MP2 MPEG2 MP2 NOTE: If your device is a Multi-Input version the below screen will display all input data as is cycles through the data available. 2. Use the Scroll Up/Down button to display IP address RF-1 39 (606.5 MHz) QAM 64 7/8 1/32 8K • Main Menu – To access the Main Menu first enter the password by pressing the OK button. Use the Scroll Up/Down buttons to enter the password. Once the password is entered press the OK button again and the LCD Screen will display “Main Menu Common Setup”. • Password – Use the Scroll Up/Down buttons to enter the password. Password is 0000. Press the OK button for each number to enter the password. Press OK again after the display shows …... HD Series. PASSWORD=? 0 COMMON SETUP MENU • Output Channel – Use the Scroll Up/Down button to change the output channel. Use the Scroll Up/Down buttons to select the desired output channel. Once the desired output channel is selected press the OK button to set the channel. The LCD Display will show both the channel number and the frequency number of the output channel (example: 39 606.5000MHz). • Note - The RF2 Channel Physical output is determined by the selection of output channel of RF1. The Encoder prevents you from selecting the last channel in the device. **See Notes on Channel Selection for more information on this topic. • Attenuation – Use the Scroll Up/Down button to select Attenuation. Press the OK button to enter the Attenuation menu. Use the Scroll/Up down button to select the desired attenuation in 1dB increments from 0 to minus 20 dB. Once the desired attenuation level is found press the OK button to set. NOTE: The RF2 Channel Physical output is determined by the selection of output channel of RF1. The Encoder prevents you from selecting the last channel in the device. **See page 9 of this manual for more information on this topic. • LCN – Use the Scroll Up/Down button to select LCN MODE. Press the OK button to enter the LCN menu. Menu options are APN, NORDIG, ITC, and EACEM. Factory default: APN. Use the Scroll Up/Down button to select the desired LCN and press he OK button to set. • Device Address – Use the Scroll Up/Down button to select Device Address. Press the OK button to enter the Device Address menu. Use the Scroll Up/Down to select the Desired Address ranging from 1 to 255 then press OK to set. A unique device address is required if setting up more than 1 encoder per site. This allows the user to distinguish each device. • Default Configuration –To reset the Encoder/Modulator back to the factory default select the Default Configuration Menu. Press OK to enter the Default Configuration Menu. Using the Up/Down button select YES to reset all programmed settings back to the factory default setting. Factory Default: NO. Caution: Once the “YES” button is pressed the unit will automatically reset to the factory default settings. All settings or changes to the encoder/modulator will be lost. • Back to Main – Select Back to Main to escape the Common Setup Menu. RL-DM4000+ User Guide and Install Manual Page 11 RF SETUP MENU • Constellation – Use the Scroll Up/Down button to select Constellation. Press the OK button to enter the Constellation menu. Select the desired Constellation / QAM setting then press the OK button to set. • FEC – Use the Scroll Up/Down button to select the FEC menu. Press the OK button to enter the FEC menu. Use the Scroll Up/ Down button to select the desired FEC setting and press the OK button to set. • Guard Interval – Use the Scroll Up/Down button to select Guard Interval. Press the OK button to enter the Guard Interval menu. Use the Scroll Up/Down button to select the desired Guard Interval and press the OK button to set. • OFDM – Use the Scroll Up/Down button to select the OFDM menu. Press the OK button to enter the OFDM menu. Use the Scroll Up/Down to select the OFDM 2K or 8K. Press OK to set. • RF Output – Use the Scroll Up/Down button to select RF Output. Press the OK button to enter the RF Output menu. Menu options are Normal, Inverted and C.W. The factory default is Normal. Use the Scroll Up/Down button to select the desired RF Output and press the OK button to set. • CELL ID – Use the Scroll Up/Down button to select CELL ID. Press the OK button to enter the CELL ID menu. Use the Scroll Up/Down button to select the desired CELL ID ranging from 0 to 65535 then press the OK button to set. Factory default is 0. • TS ID – Use the Scroll Up/Down button to select TS ID. Press the OK button to enter the TS ID menu. Use the Scroll Up/Down button to select the desired Stream ID ranging from 0 to 65535 then press the OK button to set. • Network ID – Use the Scroll Up/Down button to select Network ID. Press the OK button to enter the Network ID menu. Use the Scroll Up/Down button to select the desired Network ID ranging from 0 to 65535 then press the OK button to set. • ORG Network ID – Use the Scroll Up/Down button to select ORG Network ID. Press the OK button to enter the ORG Network ID menu. Use the Scroll Up/Down button to select the desired ID ranging from 0 to 65535 then press the OK button to set. • Network Name – Use the Scroll Up/Down button to select Network Name. Press the OK button to enter the Network Name menu. Use the Scroll Up/Down buttonto select the first character for the desired Network Name then press the OK button to set. Repeat the process for each character in the desired Network Name. A Network Name can consist up to 16 characters. • Back to Main – Select Back to Main to escape the RF Setup Menu. ENCODER SETUP MENU • Select Encoder – ­Use the OK button to enter the Select Encoder Menu. Using the Scroll Up/Down buttons select the encoder you wish to program. Use the OK button to set the Encoder. Select Encoder 1, 2, 3, or 4 based on your model number. Once Selected the Display will indicate which Encoder you are programming while in the setup function ENCODER SETUP SELECT ENCODER • Program Num – Use the Scroll Up/Down button to set 1 Program Num(Number). Press the OK button to enter the Program Num menu. Use the Scroll Up/Down to select the Program Num ranging from 1 to 65535 then press OK to set. • Channel Name – Use the Scroll Up/Down button to select Channel Name. Press the OK button to enter the Channel Name menu. Use the Scroll Up/Down menu to select the first character of the desired Channel Name then press the OK button to set. Repeat the process until the Channel Name is completed. The Channel Name can be 7 characters long. Factory Default: CHANNEL-1, CHANNEL-2, CHANNEL-3, CHANNEL-4 etc. • Provider Name – Use the Scroll Up/Down button to select Provider Name. Press the OK button to enter the Provider Name menu. Use the Scroll Up/Down menu to select the first character of the desired Provider Name then press the OK button to set. Repeat the process until the Provider Name is completed.. The Provider Name can be 16 characters long. • LCN – Use the Scroll Up/Down button to set LCN. Press the OK button to enter The Source ID menu. Use the Scroll Up/Down to set the Source ID. Range: 1 to 999. Press OK to set. • Aspect Ratio – Use the Scroll Up/Down button to select Aspect Ratio. Press the OK button to enter the Aspect Ratio menu. Use the Scroll Up/Down button to select the desired Aspect Ratio option of 4:3 or 16:9 then press the OK button to set. Factory default: 4:3. • Video Output – This Encoder / Modulator is MPEG-2 video output. RL-DM4000+ User Guide and Install Manual Page 12 • Audio Input – Use the Scroll Up/Down button to select. Press the OK button to enter the Audio Input menu. Use the Scroll Up/ Down button to select the Audio Input option: Analog. Factory Set: Analog. • Audio Output – Use the Scroll Up/Down button to select Audio Output. Press the OK button to enter the Audio Output menu. Use the Scroll Up/Down button to select the Audio Output option: MP2 (MPEG2 Layer I Audio), AAC, or AC3. Factory default: MP2. Press the OK button to set. • Closed Caption – Use the Scroll Up/Down button to select the Closed Caption Menu. Press the OK button to enter the Closed Caption menu. Enable / Disable Closed Caption control. Each Encoder will require you to Enable the Closed Caption option if you require Closed Captioning Support on a particular video output. NOTE: When using closed captioning- user must connect from the content source the composite output or cc output source to the encoder’s cvbs input connector. • Brightness – Use the Scroll Up/Down button to select Brightness. Press the OK button to enter the Brightness menu. Use the Scroll Up/Down button to select the desired Brightness value (0 to 255) and press the OK button to set. Factory default: 128. • Contrast – Use the Scroll Up/Down button to select Contrast. Press the OK button to enter the Contrast menu. Use the Scroll Up/Down button to select the desired Contrast value (0 to 255) and press the OK button to set. Factory default: 128. • Saturation – Use the Scroll Up/Down button to select Saturation. Press the OK button to enter the Saturation menu. Use the Scroll Up/Down button to select the desired Saturation value (0 to 255) and press the OK button to set. Factory default: 128. • Hue – Use the Scroll Up/Down button to select Hue. Press the OK button to enter the Hue menu. Use the Scroll Up/Down button to select the desired Hue value (0 to 255) and press the OK button to set. Factory default: 128. • Back to Mai – Select Back to Main to escape the Encoder Setup Menu WEB MANAGEMENT NETWORK SETUP • DHCP – Use the Scroll Up/Down button to select DHCP. Press the OK button to enter the DHCP menu. Use the Scroll Up/Down button to Enable/Disable. Press the OK button to set. • IP Address – Use the Scroll Up/Down button to select IP Address. Press the OK button to enter the IP Address menu. Use the Scroll Up/Down button to enter the IP Address. Use the Scroll Up/Down menu to select the desired IP Address then press the OK button to set. Repeat the process until the IP Address is completed. Press the OK button to set. Note: If DHCP is enabled you will not be able to set an IP address. Select DHCP disabled if Static IP Address required. • Subnet Mask – Use the Scroll Up/Down button to select Subnet Mask. Press the OK button to enter the Subnet Mask menu. Use the Scroll Up/Down button to enter the Subnet Mask. Use the Scroll Up/Down menu to select the first number of the desired Subnet Mask then press the OK button to set. Repeat the process until the Subnet Mask is completed. Press the OK button to set. • Gateway Address – Use the Scroll Up/Down button to select Gateway Address. Press the OK button to enter the Gateway Address menu. Use the Scroll Up/Down button to enter the Gateway Address. Use the Scroll Up/Down menu to select the first number of the desired Gateway Address then press the OK button to set. Repeat the process until the Gateway Address is completed. Press the OK button to set. • Back to Main – Select Back to Main to escape the Web Management Network Setup Menu. RL-DM4000+ User Guide and Install Manual Page 13 Installing Multiple Encoders in the Same Installation (Stacking) The following changes are required when using multiple modulators in the same installation (stacking) • Output channel - Default is 39 UHF (606.5 MHz). If the modulators are on the same output channel as another modulator or FTA channel the TV will not scan the channel in. Place all modulators on available channels between 6 to 12 VHF and 28 to 51 UHF (including adjacent channels - 38, 39, 40, etc.) Note - if you plan on using channel 52 to 69 be aware of LTE transmissions as they may interfere with each other. We recommend installing a filter. • LCN (Logic Channel Number) - default 101. If TV tuner receives two or more LCN’s on the same number, including FTA channels - the TV will automatically place the LCN on a free range. In Australia this is 350 and up. Suggest to go 101, 102, 103, etc. • Channel Name - default “CHANNEL-1” this is necessary but recommended for clients to be able to identify channels. For example “APPLE-TV”, “FOXTEL”, “DVD”, etc. • TS ID (Transport Stream) - Default can vary per product. You will need to adjust the TS ID # on each additional modulator up one number per modulator. For example if default is “TS ID #1” - leave on “TS ID #1”, place 2nd modulator on “TS ID #2”, 3rd on “TS ID #3”, etc. If the TS ID is the same number the TV tuner will not scan both channels in. • Program Number - Default can vary per product. You may need to adjust each additional modulator Program Number up one number per modulator. For example, if default is “Program Number - 1” - leave on “Program Number - #1”, place 2nd modulator on “Program Number - #2”, 3rd on “Program Number - #3”, etc. If the Program Number is the same number the TV tuner will not scan both channels in. Note - most TVs do not have an issue with this setting but we recommend changing it just in case. RL-DM4000+ User Guide and Install Manual Page 14 Item Value Password Serial Number Installation Date Purchase Date Video Input 1 Video Input 2 Video Input 3 Video Input 4 Video Input 5 Video Input 6 Video Input 7 Video Input 8 RL-DM4000+ User Guide and Install Manual Page 15 ZyCast R www.digi-modbyzycast.com www.resi-linx.com www.resi-linx.com WARRANTY WARRANTY Vcomm Ptythat Ltd the states that thethat warrant that the customer can on isprovided that digi-MOD states warrant the customer can rely onrely is that by the manufacturer. WARRANTY provided by the manufacturer. In the event of any warranty claim please In the event of any warranty claim please contact your place of purchase and it will be forwarded it Vcomm Pty Ltd states that the warrant that the customer can rely on is that contact us and The we will forward it to the The manufacturer to the manufacturer. manufacturer willmanufacturer. then determine the extent ofwill their liability. provided by the manufacturer. In the event of any warranty claim please then determine the extent of their liability. This expressly negates, to the contact us and we will forward it to the manufacturer. The manufacturer will extent possible by Australian law,then anydetermine warrantythe reliance Vcomm extent ofon their liability.Pty ThisLtd. expressly negates, to the extent possible by Australian law, any warranty reliance on Vcomm Pty Ltd. N15275