Preview only show first 10 pages with watermark. For full document please download

Rlb-500 Wiegand Output Receiver

   EMBED


Share

Transcript

INSTR,INST,WOR Linear P/N: 212902 C Material: 20 Lb. Mead Bond Size: 8.500" x 11.000" Ink: Black Side 1 of 2 Scale: 1-1 INTRODUCTION The Model WOR remote radio receiver is designed for use as an access control interface for Linear’s block coded digital transmitters. The unit receives signals from transmitters, adds a facility code to the data, and sends the information to the Wiegand input of the access control panel via a 5-wire connection. Several transmitter and receiver options can be set using the unit’s dipswitches. Three different Wiegand output formats (26, 30, & 31-bit) are supported. Three receiver options (lockout, hold, & button offset) can be set. Transmitter buttons on multi-button units can be selectively disabled. The facility code is set using 16 dipswitches. Three antenna types can be used with this receiver. The local whip antenna (supplied) screws directly on to the receiver. The directional (EXA-2000) and omni-directional (EXA-1000) remote antennas attach to the receiver’s antenna input via RG-59 cable and a type “F” connector. An on-board RADIO RANGE knob allows adjustment of the receiver’s gain. It can be set to limit the maximum radio range that the receiver can achieve. Two indicators display the receivers performance and operation. The red RADIO indicator lights when the receiver detects a radio signal. The two color red/green STATUS indicator lights green when the receiver is sending Wiegand data and during the 1-second post receiver lockout timer (if receiver lockout is enabled). The indicator turns red when the receiver’s HOLD input (connected to the access control panel) is active. Receiver test points are provided for listening to the incoming signals with an audio amplifier. Power input to the receiver can be either regulated 5 volts or 8-24 volts DC (jumper selected). The receiver is housed in a weather-resistant enclosure and can be mounted indoors or outdoors. Gaskets and a weather-tight wiring strain relief seal the unit from the elements. WOR Wiegand Output Receiver Installation Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com 1. OPEN CASE 2. OPEN CASE FROM ANTENNA END LOCATE COMPONENTS ANTENNA CONNECTOR (HIDDEN) RADIO RANGE KNOB (CLOCKWISE FOR MAXIMUM GAIN) INPUT VOLTAGE JUMPER MAX PROGRAM BUTTON OPTION DIPSWITCHES BOARD SLIDES OUT FROM 3RD SLOT UP INSIDE CASE 3. GND RADIO TEST POINTS REMOVE FOUR SCREWS AND WASHERS SET VOLTAGE INPUT JUMPER POWER AND DATA TERMINALS 4. STATUS INDICATOR RED = HOLD, GREEN = DECODE AUDIO RADIO INDICATOR SET OUTPUT FORMAT & RECEIVER OPTIONS WIEGAND OUTPUT FORMAT SWITCH 1 26-BIT SWITCH 2 30-BIT SWITCH 3 31-BIT SELECT THE WIEGAND OUTPUT FORMAT THAT MATCHES THE ACCESS CONTROL SYSTEM BEING USED BUTTON OFFSET TABLE LEFT 0 RIGHT TOP BOTTOM LEFT OR RIGHT 16384 32768 49152 RECEIVER OPTIONS SWITCH 1 - LOCKOUT DISABLE OFF - (FACTORY SETTING) CAUSES RECEIVER TO IGNORE TRANSMITTER SIGNALS FOR ONE SECOND AFTER A VALIDATED TRANSMISSION. ON - ALLOWS RECEIVER TO PASS WIEGAND DATA INSTANTLY WITH EACH VALIDATED TRANSMISSION. PLACE VOLTAGE INPUT JUMPER IN THIS POSITION TO SELECT A 8-24 VOLT DC INPUT FROM THE ACCESS CONTROL PANEL 5. PLACE VOLTAGE INPUT JUMPER IN THIS POSITION TO SELECT A REGULATED 5 VOLT DC INPUT FROM THE ACCESS CONTROL PANEL SET TRANSMITTER FACILITY CODE SWITCH 2 - HOLD ENABLE OFF - (FACTORY SETTING) HOLD INPUT SIGNALS ARE IGNORED. ON - WHEN HOLD INPUT IS ACTIVE, ANY WIEGAND DATA WILL BE HELD FOR A MAXIMUM OF ONE SECOND THEN DISCARDED UNLESS THE HOLD INPUT IS RELEASED DURING THE ONE SECOND TIME. SWITCH 3 - BUTTON OFFSET ENABLE OFF - (FACTORY SETTING) TRANSMITTERS PASS THEIR ID NUMBER TO THE WIEGAND OUTPUT WITHOUT ANY CHANGES. ON - THE TRANSMITTER ID IS OFFSET TO THE RANGE ABOVE, BASED ON WHICH BUTTON IS PRESSED. 6. S W S W S W S W SET XMTR FACILITY CODE SWITCHES TO MATCH THE FACILITY CODE PRE-PROGRAMMED INTO TRANSMITTER BLOCK BOTH FUNCTION AS LEFT TOP BUTTON BUTTON T 0 T 1 T 2 T 3 XMTR FACILITY CODE SWITCHES SET TRANSMITTER BUTTON OPTIONS 0 1 2 3 LEFT BUTTON 4 TRANSMITTER BLOCK FACILITY CODE 0-15 (ASSIGNED WHEN TRANSMITTER BLOCK IS ORDERED FROM LINEAR) 5 7 8 9 1 0 1 1 1 2 = S W IT C H O F F 1 4 1 3 RIGHT BUTTON TOP BUTTON 6 = S W IT C H O N LEFT BUTTON BOTTOM-LEFT BUTTON BOTTOM-RIGHT BUTTON RIGHT BUTTON LEFT BUTTON SET XMTR BUTTON DISABLE SWITCH(ES) ON TO PREVENT SELECTED TRANSMITTER BUTTONS FROM OPERATING OPERATE AS TOP BUTTON RIGHT BUTTON 1 5 LEFT BUTTON NOTE: THE FACTORY SETTINGS OF FACILITY CODE "0" WILL ALLOW VALIDATION OF ANY TRANSMITTER FACILITY CODE THE FACTORY SETTING ALLOWS ALL TRANSMITTER BUTTONS TO OPERATE SWITCH 4 - TOP SWITCH 5 - BOTTOM RIGHT SWITCH 6 - BOTTOM LEFT SWITCH 7 - RIGHT OR TOP RIGHT SWITCH 8 - LEFT OR TOP LEFT INSTR,INST,WOR Linear P/N: 212902 C Material: 20 Lb. Mead Bond Size: 8.500" x 11.000" Ink: Black Side 2 of 2 Scale: 1-1 7. SET OUTPUT FACILITY CODE = SWITCH ON 8. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 9. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 CONNECT TERMINALS SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT SWT OUTPUT FACILITY CODE 0 WILL PASS THROUGH THE TRANSMITTER FACILITY CODE 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SWITCH SETTINGS FOR OUTPUT FACILITY CODES 0-255 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 = SWITCH OFF CONNECT ANTENNA LOCAL WHIP ANTENNA (SUPPLIED) CONNECTED DIRECTLY TO RECEIVER N/C HOLD (BLU) DATO (GRN) DAT1 (WHT) GND (BLK) POWER AND DATA TERMINALS PWR (RED) CHOOSE AN ANTENNA TO FIT THE INSTALLATION REQUIREMENTS DIRECTIONAL EXA-2000 ANTENNA MOUNTED ON POST OMNI-DIRECTIONAL EXA-1000 ANTENNA MOUNTED ON POLE TO ACCESS CONTROL SYSTEM INDICATOR VIEWING WINDOW SCREW CONNECTOR ONTO RECEIVER HOLD (OPTIONAL) DATA POWER ROUTE WIRE THROUGH STRAIN RELIEF BEFORE WIRING TO TERMINALS (TIGHTEN LATER) FOLLOW EXA ANTENNA INSTRUCTIONS WHEN CONSTRUCTING ANTENNA 10. PROGRAM AND TEST SYSTEM WITH POWER APPLIED TO THE RECEIVER, PRESS AND RELEASE THE PROGRAM BUTTON LINEAR LIMITED WARRANTY This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear Corporation for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties express or implied. TEST TRANSMITTERS FROM VARIOUS LOCATIONS TO DETERMINE RADIO RANGE ADJUST THE RECEIVER'S INTERNAL RADIO RANGE KNOB TO LIMIT RADIO RECEPTION IF REQUIRED All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details. RADIO INDICATOR WILL FLICKER AS SIGNAL IS RECEIVED RECEPTION PATTERN WILL VARY DEPENDING ON ANTENNA USED AND SURROUNDING STRUCTURES STATUS INDICATOR LIGHTS GREEN WHEN SENDING WIEGAND DATA AND DURING RECEIVER LOCKOUT OPERATION, LIGHTS RED WHEN HOLD INPUT IS ACTIVE IMPORTANT !!! Linear radio controls provide a reliable communications link and fill an important need in portable wireless signalling. However, there are some limitations which must be observed. ✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range. ✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings. ✶ Changes or modifications to the device may void FCC compliance. ✶ Infrequently used radio links should be tested regularly to protect against undetected interference or fault. ✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users. Copyright © 2002 Linear Corporation 212902 C