Preview only show first 10 pages with watermark. For full document please download

Rlh 75w 24v Power Supply With Integrated Charge Controller Overview User Guide

   EMBED


Share

Transcript

The leader in rugged fiber optic RLH Industries, Inc. technology. ! Unconditional Lifetime Warranty USER GUIDE U-035 2014A-0925 RLH 75W 24V Power Supply with Integrated Charge Controller DIN Mount power supply for use with UPS backup battery for 24VDC industrial equipment Overview The RLH 75W AC/DC 24V power supply with integrated battery charger offers a complete power system designed for 24VDC UPS applications. The compact switching power supply has a built-in UPS charge controller easily combined with the optional DIN mount 24V 1.2AH battery pack. This system is designed to RLH 75W 24V Integrated Power Supply w/ Optional 24V 1.2Ah Battery Pack provide regulated 24V power for industrial equipment, while providing battery backup power in the event of a source power interruption. Standard Features The system features flexible AC or DC input, with low output 75W 24V power supply accepts AC or DC input power ripple along with short circuit, overvoltage and overload Short circuit, overload, over voltage and over temperature protection protection. The integrated charge controller continuously maintains the correct charge level on the battery and ensures a seamless power transition to battery power when needed for a complete UPS power supply solution. The optional battery pack contains sealed batteries that are field replaceable. The battery pack has a convenient screw terminal for wiring, and an external replaceable fuse for protection. This compact UPS system offers an excellent price/performance ratio, and provides tightly regulated output voltage for sensitive loads in industrial environments. The constant-current, shortcircuit protection limits the output current as the voltage is Cooling by free air convection UPS and battery pack use standard DIN Rail T35 per IEC 60715 LED status indicators 100% full load burn-in test Built-in battery test function Battery polarity protection Relay contact signal output and LED indicators for DC Bus OK, Battery Fail and Battery Discharge Sealed batteries are field replaceable reduced, to safely protect the control components from direct shorts and device failures. RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page 1 General Safety Practices Intended Audience This guide is intended for use by electrical technicians or knowledgeable telco/network installation, operation and repair personnel. Every effort has been made to ensure the accuracy of the information in this guide is accurate. However, due to constant product improvement, specifications and information contained in this document are subject to change without notice. Conventions Symbols for notes, attention, and caution are used throughout this manual to provide readers with additional information, advice when special attention is needed, and caution to prevent injury or equipment damage. The equipment discussed in this document may require tools designed for the purpose being described. RLH recommends that service personnel be familiar with the correct handling and use of any installation equipment used, and follow all safety precautions including the use of protective personal equipment as required. Caution - Severe Shock Hazard • Never install during a lightning storm or where unsafe high voltages are present. • This device uses high AC or DC voltages to operate. Use caution when handling copper wiring. Installation Prior to installation: • • • Check for shipping damage Check the contents to ensure correct model and capacity Have a clean, dry installation environment ready Required for installation: • • DIN rail for DIN mounting Circuit breaker, terminal blocks, AC cord and other wiring as necessary DIN rail mounting Attach the power supply and battery pack to the DIN rail by engaging the upper part of the DIN clip onto the rail first, then rotate down and snap the bottom onto the rail. Check to make sure that the housing is securely mounted onto the DIN rail. To remove, pull down on the release lanyard to unclip the units from the DIN rail. Page 2 RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com 1 Hook top of DIN clip first DIN Rail DIN Rail 2 Rotate and snap into position Mounting on to DIN rail Circuit breaker For safety and ease of maintenance, use a 3 Amp circuit breaker to protect the power supply. It is preferable to locate the circuit breaker near the input side of the power supply. The circuit breaker should go between the AC LINE connection of the input power and the input terminal on the power supply. When using DC input power, wire the breaker between the POSITIVE (+) wire of the DC power source and the input terminal on the power supply. Use terminal blocks allow to connect additional devices to the DC output of the power supply. If using terminal DIN mount blocks, install the terminal blocks onto the DIN rail prior to connecting any wiring. It is recommended to use the RED terminal block for positive, and the BLACK terminal block for negative. Contact you RLH representative for a DIN mount kit with circuit breaker, terminal blocks and DIN rail section. Connect wiring Refer to the connection diagram on the following page. Connect all wiring prior to installing the fuses. Remove power from all input wiring prior to connection the UPS system. Check to make sure the circuit breaker is OFF, then attach the AC LINE source wire to the circuit breaker. When using DC input power, wire the breaker between the POSITIVE (+) wire of the DC power source and the input terminal on the power supply. The connectors on the power supply and battery may be pulled out for ease of wiring. Be sure to seat the connectors fully when reattaching. Connect the DC OUTPUT wiring the terminal blocks or directly to the industrial equipment. Use any screw down terminal on the terminal blocks, they are all connected to the same bus. Connect the battery wiring to the screw down terminal on the front. Observe the polarity markings next to the terminal block. The terminal block itself may be removed from the battery pack for ease of installation by loosening the screws on both sides of the terminal block. Seat the connector fully when reinstalling and tighten the screws to ensure a good electrical connection. RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page 3 Power Supply/Charge Controller Negative (–) Terminal Blocks UPS Backup Battery Circuit Breaker Positive (+) Terminal Blocks !&53% !#$#).054 !# $# .2 BATT CHARGE CURRENT 2A MAX . AMP-HOUR 6 "!44 24VDC Power To Industrial Equipment , 24 24V AC INPUT: 100~260VAC 1.5A DC INPUT: 127~370VDC VOLT #(!2'%#/.42/,,%2 OUTPUT V. ADJ. 22.8~27.6V "ACKUP"ATTERY0ACK "!44 $)3 #(!2'% RLH Industries, Inc. 0.03# $    "!44 &!), RLH Industries, Inc. $#/+ $#/54054 0.  "0 WWWFIBEROPTICLINKCOM !,!2- 6$#/54054 DC OUTPUT: 24VDC 3.2A 24V  6$# /54054  !&53%  "!44$)3#(!2'% "!44&!), $#/+ 0/7%23500,9 Alarms 110VAC Mains Plug (Optional DC input) Wiring Information System Output Recommended Circuit Breaker 3.2A 3A Recommended Wire Gauge Min. Wire Gauge Max. Wire Gauge 12 AWG 14 AWG 8 AWG Install fuses Remove the fuse holder cover on the top of the power supply and install the included fuse. Refer to the specifications section for the replacement fuse rating. Apply power to the circuit breaker, and turn on the power supply by switching the circuit breaker to ON. Note: The 24VDC OUTPUT terminals are energized once input power is applied. Remove the fuse holder cover on the backup battery pack and install the included fuse. Refer to the specifications section for the replacement fuse rating. Allow 24 hours for the battery to charge fully. Page 4 RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com 125.2 LED 1 3 1 2 3 4 5 6 TB1 4 Power Supply Derating Curve 55.5 2 TB2 Power Supply Output Derating vs. Input Voltage Terminal Pin No. Assignment (TB1) 35 Pin No. 1 2 3 4 L OAD (%) L OAD (%) ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 AMBIENT TEMPERATURE ( POWER SUPPLY 100 BAT. TEST BAT. TEST CHARGE CIRCUIT LIMIT CHARGE CIRCUIT LIMIT INPUT POWER SUPPLY DETECTION DETECTION CIRCUIT CIRCUIT DC OK BAT BAT BAT FAIL DC DISCHARGE OK FAIL + + 24V BATTERY 24V BATTERY 80 60 LOAD (%) LOAD Assignment BAT DISC 1 BAT DISC 2 BAT FAIL 1 BAT FAIL 2 DC OK 1 DC OK 2 25Ax2 + + Pin No. 1 2 3 4 5 INPUT VOLTAGE (V) 60Hz 6 Charge Controller Derating Curve Derating Curve 25Ax2 LOAD Terminal Pin No. Assignment (TB2) ) UPS Block Diagram Block Diagram Assignment BATTERY INPUT + BATTERY INPUT DC INPUT DC INPUT + 40 20 RLH UPS CHARGE CONTROLLER BLOCK DIAGRAM -20 0 10 BAT DISCHARGE 20 30 45 50 60 70 (VERTICAL) AMBIENT TEMPERATURE ( ) Optional 24V 1.2Ah Backup Battery Characteristics 5 hrs 24 22 0.117A 0.005A 20 0.78A 6.5A 3.9A 2.6A 0.33A 0.21A 1 2 3 5 10 minutes 20 30 60 2 3 5 10 hours Discharge Time @ 25˚C (77˚F) 40˚C (104˚F) File Name:DR-UPS40-SPEC 2007-09-19 0˚C (32˚F) 30 20 mins 10 5 3 1.3A 18 0 3 2 1 50 Time Terminal Voltage (V) 26 20 30 0 0 500 1 2 3 5 10 20 30 50 100 200 A mA Current RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page 5 Dimensional Information 76 100 94 112 63 !&53% !#$#).054 !# $# .2 BATT CHARGE CURRENT 2A MAX AMP-HOUR 6 "!44 . , 24 24V AC INPUT: 100~260VAC 1.5A DC INPUT: 127~370VDC VOLT #(!2'%#/.42/,,%2 "ACKUP"ATTERY0ACK "!44 $)3 #(!2'% RLH Industries, Inc. 0.03# $    "!44 &!), $#/+ $#/54054 RLH Industries, Inc. 140 140 OUTPUT V. ADJ. 22.8~27.6V 0.  "0 WWWFIBEROPTICLINKCOM 24V !,!2- 6$#/54054 DC OUTPUT: 24VDC 3.2A UPS  6$# /54054  !&53%  "!44$)3#(!2'% "!44&!), $#/+ 0/7%23500,9 75W Power Supply with UPS Charge Controller 24V 1.2Ah Backup Battery Pack Ordering Information Part Number Description Input Output PSC-D-75-24-1 75 W 24VDC Output Power Supply w/ Integrated Charge Controller 110-240AC/120-370VDC 24VDC / 3A Please contact your RLH sales representative for pricing and delivery information Battery Pack and Spares Information Page 6 Part Number Description RLH-2401-1BP 24V 1.2AH UPS Backup Battery Pack w/fuse and DIN mount RLH-2401-1RB 1.2AH 24V Replacement Batteries (Set) RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Power Supply Specifications DC OUTPUT INPUT PROTECTION DC VOLTAGE 24V RATED CURRENT 3.2A CURRENT RANGE 0 ~ 4.2A RATED POWER 76.8W PEAK LOAD (23.5CFM) 100.8W RIPPLE & NOISE (max.) Note 2 240mVp-p VOLTAGE ADJ. RANGE 22.8 ~ 27.6V VOLTAGE TOLERANCE Note 3 ±1.0% LINE REGULATION ±0.5% LOAD REGULATION ±1% SETUP, RISE TIME 500ms, 30ms/230VAC, 500ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 80ms/230VAC, 20ms/115VAC at full load VOLTAGE RANGE 90 ~ 264VAC, 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 85% AC CURRENT (Typ.) 1.5A/115V, 1A/230V INRUSH CURRENT (Typ.) Cold Start 25A/115VAC, 50A/230VAC LEAKAGE CURRENT Earth leakage current <1µA / 264VAC, Touch current <100µA / 264VAC OVERLOAD 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover ENVIRONMENT WORKING TEMP. -20˚C~ +70˚C (Refer to derating curve) WORKING HUMIDITY 20 ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40˚C ~ +85˚C, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/˚C (0 ~ 45˚C) SAFETY STANDARDS ANSI/AAMI ES6060-1, TUV EN6060-1, IEC6060-1 approved WITHSTAND VOLTAGE I/P~O/P:4KVAC I/P~FG:2KVAC O/P~FG:1.5KVAC ISOLATION RESISTANCE I/P~O/P, I/P~FG, O/P~FG:100M Ohms / 500VDC / 25˚C / 70% RH EMC EMISSION Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2, -3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN6060-1-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A. OTHER MTBF 446.8K hrs min. MIL-HDBK-217F (25˚C) CONSTRUCTION Durable Powder Coated Aluminum Alloy DIMENSIONS H 5.5in. x W 3in. x D 4.4 (H 139mm x W 76mm x D 112mm) (Housing only) MOUNTING DIN Rail T35 per IEC 60715 WEIGHT 1.5 lbs. (0.7kg) SAFETY & EMC Specifications may change without notice RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page 7 Charge Controller Specifications BATTERY OUTPUT FUNCTION VOLTAGE RANGE (Typ.) 21 ~ 29V CURRENT RANGE 0 ~ 15A CHARGE CURRENT (Typ.) 2A EXTERNAL BATTERY (Typ.) 4 / 7 / 12 / 20AH / 24V RELAY CONTACT RATING 30VDC, 10A (max.) DC BUS OK Relay contact : Short when DC voltage between 21~29V( 3%), relay contacts LED (Green) ON : DC BUS OK; LED (Green) OFF : DC BUS failure BATTERY FAIL See Note 2 Relay contact : Short when battery failure is observed through the battery test function, relay contacts LED (Red) ON : Battery over-discharge warning or battery malfunction LED (Red) OFF : Battery OK BATTERY DISCHARGE Relay contact : Short when battery in discharge condition, relay contacts LED (Yellow) ON : Battery discharging LED (Yellow) OFF : Battery is not discharging or discharging current <400mA Backup Battery Pack Specifications Battery Pack Construction Durable powder coated aluminum alloy Dimensions H 5.5in. x W 2.5in. x D 3.7 (H 139mm x W 63mm x D 94mm) Mounting DIN Rail T35 per IEC 60715 Weight 3lbs. (1.4kg) Internal Batteries Two 12V replaceable batteries used in each battery pack User replaceable, spares available Battery Type Lead acid deep cycle, gel style, spill proof and maintenance free Voltage 24VDC Capacity 1.2Ah @ 20hr-rate to 23V @25˚C (77˚F) Maximum Discharge Current 20A (5 sec) Fuse 3A Operating Temperature Range Discharge -15˚C ~ 50˚C (5˚F ~ 122˚F) Charge -15˚C ~ 40˚C (5˚F ~ 104˚F) Storage -15˚C ~ 40˚C (5˚F ~ 104˚F) Nominal Operating Range 25˚C±3˚C (77˚C±5˚C) Internal Resistance Approx. 80mΩ @25˚C (77˚F) Charging Voltage Standby Use 13.65V ±0.15V @25˚C (77˚F) Cycle Use 14.7V ±0.3V @25˚C (77˚F) Maximum Charging Current Limit 0.39A Equalization and Cycle Service 28.8 to 30VDC/unit average at 25˚C Self Discharge After 3 months Approx. 90% @25˚C (77˚F) After 6 months Approx. 82% @25˚C (77˚F) After 12 months Approx. 70% @25˚C (77˚F) Higher temperatures will reduce storage time. Page 8 RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Warranty RLH is recognized throughout the U.S. in the telecommunications industry for our experience and we manufacture our products with total confidence in our quality. This product is guaranteed to be free of defects in material and workmanship for up to 3 years of service. Batteries are covered by the manufacturer’s warranty. RLH Industries, Inc. will repair or replace products that fail provided the defective part is returned to RLH freight prepaid. To make a warranty claim, or schedule repair or replacement of your RLH product, please contact us for an RMA number. You will be promptly assisted by one of our warranty specialists. All returns must have an RMA number before we can receive any items. Technical Support Email: [email protected] 24/7 technical support: Toll Free 1-855-RLH-24X7 Toll Free 1-855-754-2497 Contact Information Corporate Headquarters: RLH Industries, Inc. 936 N. Main Street Orange, CA 92867 USA Phone: (714) 532-1672 Toll Free 1-800-877-1672 Toll Free 1-866-DO-FIBER Fax: (714) 532-1885 Email: [email protected] Web site: www.fiberopticlink.com RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page 9 RLH Industries, Inc. 936 N. Main Street, Orange, CA 92867 USA T: (714) 532-1672 F: (714) 532-1885 Page 10 Please contact your RLH sales representative for pricing and delivery information. Specifications subject to change without notice. RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com