RMS-0740 Radiation Measurement System The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3axis radiation pattern measurement in nonanechoic spaces. With a frequency range of 700MHz to 4GHz it is very well suited for characterization and measurement of Antenna Radiation Patterns, Antenna Gain, ERP, TRP, Field Strength. Extensive evaluation has shown that – with proper setup - the accuracy of the RMS is similar to that of anechoic test labs. Characterize wireless devices of today, like IOT devices, routers, phones, domotica products, electronic gadgets, tablets, laptops, RF-modules etc.
Measure Wireless Radiation Patterns in minutes No anechoic chamber required features • • • • • • • •
Measurement of RF device Constant Carrier radiation patterns. System frequency range 700 to 4000 MHz. Measuring distance 0.8 to 3 meter. Simultaneous Horizontal and Vertical polarization measurement. Simultaneous measurement of harmonic radiation. 3-axis measurement (1 turn per axis) Narrow antenna beam-width for nonanechoic environments. Narrow receiver bandwidth for non-shielded environments.
MegiQ RMS-0740
• •
• •
• •
Plots per axis and semi 3D. Plots of radiated power ERP (dBm), Antenna Gain (dBi), Field Strength (dBuV/m). Calculation of TRP, Minimum, Maximum and Average radiation. Integrated PC software suite supports measurement setup, rotation control, graphing, data storage and report generation. Optional Generator (RMS0740-GEN) for standalone antenna measurement. Optional Heavy Duty turntable (30kg).
© 2016, MegiQ BV
MegiQ
Affordable Test & Measurement
Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479
[email protected] www.megiq.com
Measurement System
Measurement
• • • • • • • •
Antenna height 100cm to 180cm Dual Polarization Antenna Dual channel measuring receiver Generator output (option) Rotation controller unit Power supply USB connection for computer control Mains connection
Turn Table
• • • • • • • •
Height 70cm and 130cm Stepper motor drive Smooth acceleration Less than 30 seconds per rotation Table 28 x 28cm Max EUT weight at 130cm: 2.5kg Max EUT weight at 70cm: 7.5kg Heavy Duty option for 30kg
The RMS rotates an object on the turntable and measures the radiation. With a rotation around the X, Y and Z axis the software plots the patterns and calculates statistics including Total Radiated Power (TRP). Each measuring point can contain a sweep of multiple frequency, so that multiple radiation patterns can be measured in one rotation sequence. With the Generator options the RMS can also perform an antenna sweep and show the antenna gain over frequency.
MegiQ RMS-0740
© 2016, MegiQ BV
MegiQ
Affordable Test & Measurement
Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479
[email protected] www.megiq.com
Software
The software shows statistics of the radiation patterns. It also provides functions for organizing the measurements and create reports. Measurement modes: • Monitor mode: Search and monitor a signal. The software shows the horizontal and vertical signal in a polarization circle. • Radiation patterns: Rotate and measure radiation patterns • Antenna frequency sweep: Shows the antenna gain over a frequency range. • Transmit a carrier with a calibrated power on the horizontal or vertical antenna. The software controls: • The measurement receiver • The turntable • Optional generator output • Import of S parameters of the feed coax from the generator to the EUT antenna. The results are presented for the 3 axes and in a semi-3D form. They can be plotted in: • Antenna Gain (dBi) • Radiated Power EiRP (dBm) • Field Strength
MegiQ RMS-0740
© 2016, MegiQ BV
MegiQ Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479
[email protected] www.megiq.com
Affordable Test & Measurement
Reports YZ EiRP 868.247 MHz
ZX EiRP 868.247 MHz
0 Y 10 dBm 5 0 -5 -10 -15 -20 -25 -25 -20 -15 -10 -5 0 5 10
315
270
225
H
XY EiRP 868.247 MHz
0
180 V
45
Z 10 dBm 5 0 -5 -10 -15 -20 -25 -25 -20 -15 -10 -5 0 5 10
315
90
270
135
225
HV
H
EiRP (dBm)
180 V
45
Dir 3.0 3.7 3.0
X 10 dBm 5 0 -5 -10 -15 -20 -25 -25 -20 -15 -10 -5 0 5 10
315
90
270
135
225
HV
180 V
H
EiRP (dBm)
YZ Plane Totals - 868.247 MHz Pol Min Max Avg TRP H -4.5 5.7 2.7 2.7 V -32.4 -11.5 -15.2 -15.2 HV -4.0 5.7 2.8 2.8
3D EiRP 868.247 MHz
0
Z 90 10
Dir 3.9 0.6 0.6
10
Y
X
135
10
HV
YZ
EiRP (dBm)
ZX Plane Totals - 868.247 MHz Pol Min Max Avg TRP H -27.1 -17.9 -21.9 -21.8 V 2.9 3.9 3.3 3.3 HV 2.9 4.0 3.4 3.3
10
10
ZX
XY
EiRP (dBm)
XY Plane Totals - 868.247 MHz Pol Min Max Avg TRP H -23.0 5.2 1.6 1.5 V -24.4 -3.2 -6.8 -6.7 HV -4.8 5.2 2.1 2.1
Test measurements\Scarp 300cm 3-Ax Rotation: 72 Steps Measure: Rotation 3 Axes; EUT
10
45
3 Plane Totals - 868.247 MHz Dir 3.7 3.5 3.1
Pol HV
Min -4.8
Max 5.7
Avg 2.8
TRP 2.8
Dir 3.0
11/13/2015 11:04:14 AM Frequency: 868.247 MHz Distance: 3.00 meter
Sweep Gain 10
180
Level
Phase
5
90
[dBi] 0
[Deg]
-5
0
-10 -90 -15 -20 0.60
0.94
1.28
1.62 Lev el-H
1.96 2.30 2.64 Center 2.30GHz / Span 3.40GHz Lev el-V Lev el-HV Phase-H Phase-V
2.98
F
3.66
[GHz]
-180 4.00
Phase-HV
Test measurements\Gain LogPer Hor Sw eep: Measure: Sw eep; RMS
3.32
11/13/2015 3:40:36 PM
Frequency: 600 > 4000 MHz 170 steps (20/) Distance: 2.85 meter
EM CO 3115 M eas ure d vs Spe c 12.0 10.0 8.0 6.0 4.0 2.0 0.0 -2.0 700
1200
1700
2200 EMCO31153AXNormal
MegiQ RMS-0740
2700
3200
3700
EMCO3115Spec
© 2016, MegiQ BV