Preview only show first 10 pages with watermark. For full document please download

Rms-0740 Radiation Measurement System - Top

   EMBED


Share

Transcript

MegiQ Affordable Test & Measurement Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479 [email protected] www.megiq.com RMS-0740 Radiation Measurement System The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3axis radiation pattern measurement in nonanechoic spaces. With a frequency range of 700MHz to 4GHz it is very well suited for characterization and measurement of Antenna Radiation Patterns, Antenna Gain, ERP, TRP, Field Strength. Extensive evaluation has shown that – with proper setup - the accuracy of the RMS is similar to that of anechoic test labs. Characterize wireless devices of today, like IOT devices, routers, phones, domotica products, electronic gadgets, tablets, laptops, RF-modules etc. Measure Wireless Radiation Patterns in minutes No anechoic chamber required features • • • • • • • • Measurement of RF device Constant Carrier radiation patterns. System frequency range 700 to 4000 MHz. Measuring distance 0.8 to 3 meter. Simultaneous Horizontal and Vertical polarization measurement. Simultaneous measurement of harmonic radiation. 3-axis measurement (1 turn per axis) Narrow antenna beam-width for nonanechoic environments. Narrow receiver bandwidth for non-shielded environments. MegiQ RMS-0740 • • • • • • Plots per axis and semi 3D. Plots of radiated power ERP (dBm), Antenna Gain (dBi), Field Strength (dBuV/m). Calculation of TRP, Minimum, Maximum and Average radiation. Integrated PC software suite supports measurement setup, rotation control, graphing, data storage and report generation. Optional Generator (RMS0740-GEN) for standalone antenna measurement. Optional Heavy Duty turntable (30kg). © 2016, MegiQ BV MegiQ Affordable Test & Measurement Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479 [email protected] www.megiq.com Measurement System Measurement • • • • • • • • Antenna height 100cm to 180cm Dual Polarization Antenna Dual channel measuring receiver Generator output (option) Rotation controller unit Power supply USB connection for computer control Mains connection Turn Table • • • • • • • • Height 70cm and 130cm Stepper motor drive Smooth acceleration Less than 30 seconds per rotation Table 28 x 28cm Max EUT weight at 130cm: 2.5kg Max EUT weight at 70cm: 7.5kg Heavy Duty option for 30kg The RMS rotates an object on the turntable and measures the radiation. With a rotation around the X, Y and Z axis the software plots the patterns and calculates statistics including Total Radiated Power (TRP). Each measuring point can contain a sweep of multiple frequency, so that multiple radiation patterns can be measured in one rotation sequence. With the Generator options the RMS can also perform an antenna sweep and show the antenna gain over frequency. MegiQ RMS-0740 © 2016, MegiQ BV MegiQ Affordable Test & Measurement Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479 [email protected] www.megiq.com Software The software shows statistics of the radiation patterns. It also provides functions for organizing the measurements and create reports. Measurement modes: • Monitor mode: Search and monitor a signal. The software shows the horizontal and vertical signal in a polarization circle. • Radiation patterns: Rotate and measure radiation patterns • Antenna frequency sweep: Shows the antenna gain over a frequency range. • Transmit a carrier with a calibrated power on the horizontal or vertical antenna. The software controls: • The measurement receiver • The turntable • Optional generator output • Import of S parameters of the feed coax from the generator to the EUT antenna. The results are presented for the 3 axes and in a semi-3D form. They can be plotted in: • Antenna Gain (dBi) • Radiated Power EiRP (dBm) • Field Strength MegiQ RMS-0740 © 2016, MegiQ BV MegiQ Weegschaalstraat 3 NL-5632 CW Eindhoven +31 40 291 1479 [email protected] www.megiq.com Affordable Test & Measurement Reports YZ EiRP 868.247 MHz ZX EiRP 868.247 MHz 0 Y 10 dBm 5 0 -5 -10 -15 -20 -25 -25 -20 -15 -10 -5 0 5 10 315 270 225 H XY EiRP 868.247 MHz 0 180 V 45 Z 10 dBm 5 0 -5 -10 -15 -20 -25 -25 -20 -15 -10 -5 0 5 10 315 90 270 135 225 HV H EiRP (dBm) 180 V 45 Dir 3.0 3.7 3.0 X 10 dBm 5 0 -5 -10 -15 -20 -25 -25 -20 -15 -10 -5 0 5 10 315 90 270 135 225 HV 180 V H EiRP (dBm) YZ Plane Totals - 868.247 MHz Pol Min Max Avg TRP H -4.5 5.7 2.7 2.7 V -32.4 -11.5 -15.2 -15.2 HV -4.0 5.7 2.8 2.8 3D EiRP 868.247 MHz 0 Z 90 10 Dir 3.9 0.6 0.6 10 Y X 135 10 HV YZ EiRP (dBm) ZX Plane Totals - 868.247 MHz Pol Min Max Avg TRP H -27.1 -17.9 -21.9 -21.8 V 2.9 3.9 3.3 3.3 HV 2.9 4.0 3.4 3.3 10 10 ZX XY EiRP (dBm) XY Plane Totals - 868.247 MHz Pol Min Max Avg TRP H -23.0 5.2 1.6 1.5 V -24.4 -3.2 -6.8 -6.7 HV -4.8 5.2 2.1 2.1 Test measurements\Scarp 300cm 3-Ax Rotation: 72 Steps Measure: Rotation 3 Axes; EUT 10 45 3 Plane Totals - 868.247 MHz Dir 3.7 3.5 3.1 Pol HV Min -4.8 Max 5.7 Avg 2.8 TRP 2.8 Dir 3.0 11/13/2015 11:04:14 AM Frequency: 868.247 MHz Distance: 3.00 meter Sweep Gain 10 180 Level Phase 5 90 [dBi] 0 [Deg] -5 0 -10 -90 -15 -20 0.60 0.94 1.28 1.62 Lev el-H 1.96 2.30 2.64 Center 2.30GHz / Span 3.40GHz Lev el-V Lev el-HV Phase-H Phase-V 2.98 F 3.66 [GHz] -180 4.00 Phase-HV Test measurements\Gain LogPer Hor Sw eep: Measure: Sw eep; RMS 3.32 11/13/2015 3:40:36 PM Frequency: 600 > 4000 MHz 170 steps (20/) Distance: 2.85 meter EM CO 3115 M eas ure d vs Spe c 12.0 10.0 8.0 6.0 4.0 2.0 0.0 -2.0 700 1200 1700 2200 EMCO31153AXNormal MegiQ RMS-0740 2700 3200 3700 EMCO3115Spec © 2016, MegiQ BV