Preview only show first 10 pages with watermark. For full document please download

Rng-batt-gel12-100 (12v100ah)

   EMBED


Share

Transcript

RNG-BATT-GEL12-100 (12V100Ah) DG (Deep Cycle GEL,12 Volts ) series is pure GEL battery with 12 years floating design life , it is ideal for standby or frequent cyclic discharge applications under extreme environments. By using strong grids, high purity lead and patented Gel electrolyte, the DG series of fers excellent recovery after deep discharge under frequent cyclic discharge use, and can deliver 400 cycles at 100% DOD. Suitable for solar , CATV, marine , RV and deep discharge UPS, communication , and telecommunication , etc. Specification Cells Per Unit 6 Voltage Per Unit 12 Capacity 100Ah@20hr-rate to 1.75V per cell @25 C Weight Approx. 30.0 Kg ( Tolerance±2%) Max. Discharge Current 1000 A (5 sec) Internal Resistance Approx. 7.5 mΩ Operating Temperature Range Discharge: -40 C~60 C o Charge:-20 oC~50 C o o Storage: -40 C~60 C Normal Operating Temperature Range 25 C±5 oC Float charging Voltage 13.6 to 13.8 VDC/unit Average at 25 C Recommended Maximum Charging Current 20A Equalization and Cycle Service 14.2 to 14.4VDC/unit Average at 25 C Self Discharge RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored for more than 6 months at 25oC. Self-discharge ratio less than 3% per month at 25oC. Please charge batteries before using. Terminal Terminal F5/F12 Container Material A.B.S. UL94-HB, UL94-V0 Optional. o o o o o o Dimensions Terminal F12 2 5 Unit: mm Dimension: 328(L)×172(W)×222(H) 37 Terminal F5 2775 E Philadelphia St, Ontario, CA 91761, USA TEL: 800-330-8678 www.renogy.com Constant Current Discharge Characteristics: F.V/Time 9.60V 10.0V 10.2V 10.5V 10.8V 11.1V 5MIN 248.9 241.7 234.5 213.1 194.5 168.0 10MIN 15MIN 185.4 145.0 176.4 142.1 170.1 139.8 158.9 134.7 146.6 125.6 132.5 114.0 30MIN 95.38 93.80 93.50 93.00 92.50 87.39 o A (25 C)(The capacity reaches the peak value after 5-20 cycles.) 1HR 58.30 58.03 57.49 56.96 55.02 52.27 2HR 35.10 34.84 34.57 34.31 33.69 32.20 3HR 25.39 25.30 25.10 25.00 24.32 23.25 4HR 20.27 20.18 20.08 19.89 19.43 18.49 5HR 17.21 17.11 17.01 16.81 16.39 15.69 8HR 11.66 11.56 11.47 11.37 10.92 10.46 10HR 9.678 9.585 9.492 9.399 9.100 8.831 20HR 5.305 5.209 5.112 5.000 4.748 4.468 Constant Power Discharge Characteristics: W (25 C)(The capacity reaches the peak value after 5-20 cycles.) o F.V/Time 9.60V 10.0V 10.2V 10.5V 10.8V 11.1V 5MIN 2626 2574 2545 2344 2159 1919 10MIN 15MIN 1974 1581 1914 1556 1863 1538 1755 1485 1637 1388 1497 1264 30MIN 1070 1069 1067 1062 1057 1005 All mentioned values are average values 1HR 673.7 672.1 666.9 660.9 641.9 614.4 2HR 413.7 411.5 409.0 406.1 400.9 386.0 4HR 241.6 241.3 240.8 238.5 233.1 221.8 5HR 205.3 204.8 204.1 201.7 196.7 188.3 8HR 139.2 138.5 137.6 136.5 131.0 125.5 10HR 115.7 114.9 113.9 112.8 109.2 106.0 Storage characteristic 120 100 Capacity (%) 100 80 60 100% D.O.D 40 80% D.O.D 50% D.O.D 30% D.O.D 15% D.O.D Supplementary charge required (Carry out supplementary charge before use if 100% capacity is requires) 0℃ 80 10℃ Supplementary charge required before use. This supplementary charge will help to recover the capacity and should be made as early as possible. 60 20℃ 40 30℃ 40℃ Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached 20 20 0 400 0 800 1200 1600 2000 2 2400 4 6 15 Supplementary charge and storage guidelines cyclic use Charge Volume 14 8 10 12 14 16 18 20 22 24 Storage T ime (months) Number of Cycle(Times) Charge characteristic curve for 20HR 63.61 62.50 61.35 60.00 56.97 53.62 ( Tolerance ±2%) . Life characteristics of cyclic use Capacity(%) 3HR 302.9 302.3 301.0 299.8 291.6 279.0 Charge Voltage 120 0.24 100 0.20 80 0.16 60 0.12 13 11 10 Charge Current 9 0 2 4 6 8 40 0.08 20 0.04 0 0 10 12 14 16 18 20 24 28 Charge Time(h) 2775 E Philadelphia St, Ontario, CA 91761, USA T erm inal V oltage (V ) 12 C h a rg e C u rre n t (C A ) ① Discharge 100%(0.05CA×20h) 50%(0.05CA×10h) ② Charge Charge Voltage2.275V/C Charge Current0.1CA ③ Temperature 25℃ C h a rg e V o lu m e (% ) C h a rg e V o lta g e ( V ) 12 13 11 0.16C 0.093C 0.35C 0.62C 10 3C 0.05C 1C 9 0.6 1.2 3 6 12 30 1 2 5 10 20 24 Hr min Discharge Time TEL: 800-330-8678 www.renogy.com