Transcript
RNG-BATT-GEL12-100
(12V100Ah)
DG (Deep Cycle GEL,12 Volts ) series is pure GEL battery with 12 years floating design life , it is ideal for standby or frequent cyclic discharge applications under extreme environments. By using strong grids, high purity lead and patented Gel electrolyte, the DG series of fers excellent recovery after deep discharge under frequent cyclic discharge use, and can deliver 400 cycles at 100% DOD. Suitable for solar , CATV, marine , RV and deep discharge UPS, communication , and telecommunication , etc.
Specification Cells Per Unit
6
Voltage Per Unit
12
Capacity
100Ah@20hr-rate to 1.75V per cell @25 C
Weight
Approx. 30.0 Kg ( Tolerance±2%)
Max. Discharge Current
1000 A (5 sec)
Internal Resistance
Approx. 7.5 mΩ
Operating Temperature Range
Discharge: -40 C~60 C o Charge:-20 oC~50 C o o Storage: -40 C~60 C
Normal Operating Temperature Range
25 C±5 oC
Float charging Voltage
13.6 to 13.8 VDC/unit Average at 25 C
Recommended Maximum Charging Current
20A
Equalization and Cycle Service
14.2 to 14.4VDC/unit Average at 25 C
Self Discharge
RITAR Valve Regulated Lead Acid (VRLA) batteries can be stored for more than 6 months at 25oC. Self-discharge ratio less than 3% per month at 25oC. Please charge batteries before using.
Terminal
Terminal F5/F12
Container Material
A.B.S. UL94-HB, UL94-V0 Optional.
o
o
o
o
o
o
Dimensions Terminal F12 2
5
Unit: mm Dimension: 328(L)×172(W)×222(H)
37
Terminal F5
2775 E Philadelphia St, Ontario, CA 91761, USA
TEL: 800-330-8678
www.renogy.com
Constant Current Discharge Characteristics: F.V/Time 9.60V 10.0V 10.2V 10.5V 10.8V 11.1V
5MIN 248.9 241.7 234.5 213.1 194.5 168.0
10MIN 15MIN 185.4 145.0 176.4 142.1 170.1 139.8 158.9 134.7 146.6 125.6 132.5 114.0
30MIN 95.38 93.80 93.50 93.00 92.50 87.39
o
A (25 C)(The capacity reaches the peak value after 5-20 cycles.) 1HR 58.30 58.03 57.49 56.96 55.02 52.27
2HR 35.10 34.84 34.57 34.31 33.69 32.20
3HR 25.39 25.30 25.10 25.00 24.32 23.25
4HR 20.27 20.18 20.08 19.89 19.43 18.49
5HR 17.21 17.11 17.01 16.81 16.39 15.69
8HR 11.66 11.56 11.47 11.37 10.92 10.46
10HR 9.678 9.585 9.492 9.399 9.100 8.831
20HR 5.305 5.209 5.112 5.000 4.748 4.468
Constant Power Discharge Characteristics: W (25 C)(The capacity reaches the peak value after 5-20 cycles.) o
F.V/Time 9.60V 10.0V 10.2V 10.5V 10.8V 11.1V
5MIN 2626 2574 2545 2344 2159 1919
10MIN 15MIN 1974 1581 1914 1556 1863 1538 1755 1485 1637 1388 1497 1264
30MIN 1070 1069 1067 1062 1057 1005
All mentioned values are average values
1HR 673.7 672.1 666.9 660.9 641.9 614.4
2HR 413.7 411.5 409.0 406.1 400.9 386.0
4HR 241.6 241.3 240.8 238.5 233.1 221.8
5HR 205.3 204.8 204.1 201.7 196.7 188.3
8HR 139.2 138.5 137.6 136.5 131.0 125.5
10HR 115.7 114.9 113.9 112.8 109.2 106.0
Storage characteristic
120
100
Capacity (%)
100 80 60
100% D.O.D
40
80% D.O.D
50% D.O.D
30% D.O.D
15% D.O.D
Supplementary charge required (Carry out supplementary charge before use if 100% capacity is requires)
0℃
80 10℃
Supplementary charge required before use. This supplementary charge will help to recover the capacity and should be made as early as possible.
60 20℃
40
30℃
40℃
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached
20
20
0 400
0
800
1200
1600
2000
2
2400
4
6
15
Supplementary charge and storage guidelines
cyclic use
Charge Volume
14
8 10 12 14 16 18 20 22 24 Storage T ime (months)
Number of Cycle(Times)
Charge characteristic curve for
20HR 63.61 62.50 61.35 60.00 56.97 53.62
( Tolerance ±2%) .
Life characteristics of cyclic use
Capacity(%)
3HR 302.9 302.3 301.0 299.8 291.6 279.0
Charge Voltage
120
0.24
100
0.20
80
0.16
60
0.12
13
11 10
Charge Current
9 0
2
4
6
8
40
0.08
20
0.04
0
0
10 12 14 16 18 20 24 28
Charge Time(h)
2775 E Philadelphia St, Ontario, CA 91761, USA
T erm inal V oltage (V )
12
C h a rg e C u rre n t (C A )
① Discharge 100%(0.05CA×20h) 50%(0.05CA×10h) ② Charge Charge Voltage2.275V/C Charge Current0.1CA ③ Temperature 25℃
C h a rg e V o lu m e (% )
C h a rg e V o lta g e ( V )
12 13
11 0.16C 0.093C 0.35C 0.62C
10 3C
0.05C
1C
9 0.6
1.2
3
6
12
30
1
2
5
10
20
24
Hr
min Discharge Time
TEL: 800-330-8678
www.renogy.com