RO
Corridor Wraparound / 1 or 2-Lamp T5, T5HO, T8 PROJECT INFORMATION Project Name
Type
Catalog No.
Date
CONSTRUCTION
Fixture shipped ready to assemble. Install sockets, and attach end caps in field. Lens assembly shipped separately. BALLASTS
FEATURES • Matches the AWN Series in appearance • Clear acrylic prismatic diffuser. Hinges from either side. Flat bottom and vertical sides (shipped separately) • Linear side prisms control visual brightness and direct light onto adjacent ceiling area • Injection molded white plastic decorative ends are removable for continuous row mounting. Joiner bands are provided • Heavy gauge steel die formed housing with recessed embossments behind ballasts for cooler operation and longer life
Energy efficient ballasts are thermally protected, automatic resetting, Class P, high power factor, sound rated A. CEE NEMA Premium compliant. ELECTRICAL
Standard class "P," thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
FINISH
All parts pre-painted with high gloss baked white enamel, minimum reflectance 86%, applied over iron phosphate pre-treatment for maximum adhesion and rust resistance. SHIELDING
100% clear prismatic acrylic. CERTIFICATION
All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924.
ORDERING INFORMATION RO MODEL RO Corridor Wraparound
EXAMPLE RO4-232-EU
– LENGTH 2 2' 4 4' 8 8'
– NO. OF LAMPS IN CROSS SECTION 1 One 2 Two
LAMP TYPE 17 28 32 54
2', T8: 17 Watt 4', T5: 28 Watt 4', T8: 32, 30, 28 or 25 Watt 4', T5HO: 54 or 51 Watt
– BALLAST E Electronic T8, Instant Start (Std.) 4E 4-Lamp Electronic T8, Instant Start (Std.) EP Electronic T5 or T8, Programmed Start 4EP 4-Lamp Electronic T5 or T8, Programmed Start
VOLTAGE U 120V-277V 347 347V
OPTIONS GLR Fast Blow Fuse EL Emergency Battery Pack PAF Paint After Fabrication
ACCESSORIES (ORDER SEPARATELY) ITB4 T-Bar Hanger S18 18" Stem, Canopy
Page 1/2 Rev. 06/19/17
WRAPS / RO.indd
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
RO
Corridor Wraparound / 1 or 2-Lamp T5, T5HO, T8
PHOTOMETRIC DATA
Test 10408 Test Date 4/2/93
LUMINAIRE DATA
ZONAL LUMEN SUMMARY Zone
RO4-232-E 6" × 48" 2-Lamp with Wraparound Acrylic Prismatic Lens B232I120 0.88 F32T8 2900 55 N/A 0º = 1.26 90º = 1.38 Length: 4.00 Width: 0.50 Height: 0.00
Luminaire Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
ENERGY DATA
Lumens % Lamp % Fixt.
0-30 0-40 0-60 0-90 90-120 90-130 90-150 90-180 0-180
1026 1701 2833 3774 650 758 862 887 4661
17.7 29.3 48.8 65.1 11.2 13.1 14.9 15.3 80.4
22.0 36.5 60.8 81.0 13.9 16.3 18.5 19.0 100.0
INDOOR CANDELA PLOT 180
165
150
Total Luminaire Efficiency
80.4%
Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
75 Noncompliant $3.20 based on 3000 hrs. and $0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
135
Average Luminance Angle
1300
120
RCR
COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10
70 83 75 69 63 58 53 50 46 43 40
80 50 30 78 74 68 63 60 53 53 46 48 41 43 36 39 32 36 29 33 26 30 24
10 71 58 48 41 35 31 27 24 22 20
70 50 30 75 72 65 60 58 52 51 45 46 39 41 35 38 31 34 28 31 25 29 23
70 79 72 65 60 55 51 47 44 41 39
650
10 68 56 47 40 34 30 27 24 21 19
50 30 66 56 48 42 37 33 29 27 24 22
50 69 60 53 47 42 38 35 32 29 27
10 63 52 44 38 33 29 25 23 20 18
0 0 52 43 36 31 27 24 21 19 17 16
105
90
75
0 30 40 45 50 55 60 65 70 75 80 85
0.0
22.5
45.0
67.5
90.0
6701 6581 6344 5998 5174 3875 3025 2738 2612 2620 2603 2655
6701 6929 6759 6371 5677 4926 4144 3515 3273 3535 4432 7102
6701 7308 7061 6546 5903 5283 4736 4432 4532 5323 7563 15500
6701 7395 7089 6409 5618 5236 5188 5361 6027 8131 13172 27727
6701 7383 7040 6302 5635 5423 5393 5642 6766 9462 15280 31618
650 60
1300
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
0
15
30
45
Horiz 0-180
45.0
0.0
90.0
DIMENSIONAL DATA
STEM MOUNTING
A
B
24"
A
A
A B
45⁄8"
A
B
AA
B
3"
A
A
181⁄6"
48" B
A
A
A
B
B
45⁄8"
A
A
B
3"
A
B
A
A
B
A
B
A
241⁄8"
S18 Stem Hanger 96" 45⁄8" A
3"
A
B
B
A
A
6"
48"
A
B
48"
48"
A
36"
4' Fixtures A - 7/8" Diameter Knockout B - 5⁄16" x 1⁄2" hole A
B
A
43/16" B
A
A
A
B
47/16" End
6" B
A
96"
96"
84"
8' Fixtures Recommended Stem Hanging Arrangements 6"
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 06/19/17
WRAPS / RO.indd
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
B