Preview only show first 10 pages with watermark. For full document please download

Robonet_eng_v2

   EMBED


Share

Transcript

GB Network Controller www.robocylinder.de Greatly reduces time and effort of wiring and installation RoboNet is a new type of controller unit that can freely operate robot cylinders via a field network. This makes it possible to greatly reduce the time and effort of wiring installation compared to conventional controllers by reducing wiring, making the controller smaller, and using DIN rail installation. Press fit B Part conveyance C Ejection Press fit A Part conveyance B Part conveyance A 3 Part conveyance C 2 PLC Part conveyance B Field network DeviceNet/CC-Link/ProfiBus 1 Press fit A Press fit B Ejection Operation Operation Part conveyance A Operation 1 PLC Reduced wiring By connecting each line of the I/O cable to lines Move position/velocity/acceleration and other data Field network DeviceNet CC-Link ProfiBus wired to the PLC terminals with the field network, 1 wiring processing is completed with one dedicated cable. 2 3 Also, since the unit can be coupled by just connecting with the unit connection board, the controller wiring work is greatly simplified. Part conveyance A Part conveyance B Press fit A Part conveyance C Press fit B Ejection Robonet communication connection board (See Page 10.) Power supply connection board (See Page 10.) Terminal resistance board (See Page 10.) (Coupling section within RoboNet unit) 1 Newly Developed Network Controller Arrives! 2 The robot can be moved by directly specifying numeric values for the move position/velocity/ acceleration and other data. Besides the conventional method of moving the robot to pre-taught Position specification movement Direct numeric value specification movement Velocity/acceleration specification positions it is also possible to operate the robot by sending information as a string of numeric data that contains position, velocity, acceleration, etc. values. This is effective for cases such as when the move position changes with each piece or when one wants * RoboNet operates via the field network; the standard controller operates with PIO. 34 mm Ultra-compact Each unit is an ultra-compact size of 34mm wide by 100mm high x 73 mm deep. Also, since there is no base unit and the main unit is coupled with connectors, the controller takes up little space for installation even if there are many units. 4 Standard controller (ACON/PCON) (Not possible with PIO) (Possible with serial communications) Current value output to move the robot to an arbitrary position. 3 ROBONET controller 100 mm Can operate up to 16 axes Up to 16 controller units can be connected to one Communications Unit 2 communications unit (GatewayR unit). Controller unit Up to 16 units can be connected One can also freely mix and connect RACON units (RCA controllers) and RPCON units (RCP2 controllers). 5 Simple absolute specifications that do not require a return to home position Simple absolute R unit RACON RPCON The simple absolute R unit makes it possible to operate incremental specification axes without returning to the home position. By mounting a simple absolute R unit on a RACON unit (RCA controller)/RPCON unit (RCP2 controller), the actuator encoder data is backed up even if the power is cut off. 6 DIN rail installation The controller is installed with DIN rails, so it can be fastened and removed with one touch. 2 System configuration/component units System configuration PLC • DeviceNet • CC-Link • ProfiBus Field network Teaching box (option) (Model: CON-T / RCM-E / RCM-P) (See Page 9.) * When an actuator is used with the simple absolute specification, a simple absolute R is mounted and the encoder cable is connected to the simple absolute R unit side. PC software (option) RS232 connection board (Model: RCM-101-MW) Encoder cable (attached to actuator) (Model: CB-RCP2-PA) (See Page 10.) USB connection board (Model: RCM-101-USB) (See Page 9.) 24-VDC power supply Actuator RCP2 series Motor cable (attached to actuator) (Model: CB-RCP2-MA) (See Page 10.) 24V 0V FG Encoder cable (attached to actuator) (Model: CB-ACS-PA) (See Page 10.) Motor cable (attached to actuator) (Model: CB-ACS-MA) (See Page 10.) Actuator RCA series Component unit/ordering method explanation For RoboNet, you order the required units individually and use them together freely. Even if you want to add actuators later, you can do so simply by ordering additional RACON/RPCON units. Unit name Gateway R unit Contents See Page _ This unit is for connection to the field network. There are four types to select from: DeviceNet/CC-Link/ProfiBus/SIO. * This unit is a required unit for using RoboNet. P5 P6 RACON unit This is the controller unit for operating an RCA actuator. (Each actuator axis requires one unit.) The standard specifications are the incremental specifications, but this unit can be used with the simple absolute specifications by just combining with a simple absolute R unit. P7 RPCON unit This is the controller unit for operating an RCP2 actuator. (Each actuator axis requires one unit.) The standard specifications are the incremental specifications, but this unit can be used with the simple absolute specifications by just combining with a simple absolute R unit. P7 Simple absolute This is the backup battery unit for holding R unit the actuator encoder data when the power is switched Off. Gateway R unit RACON unit RPCON unit Simple absolute R unit Extension unit Extension unit P8 This is an extension unit for placing many ROBONET units in two lines. Also for operating single controllers such as SCON or PCON-CF on network. P8 ■ Order method RoboNet is used by ordering the necessary units one by one and using them together. This means you can add or change units afterwards. (Order example) Operating the two actuator axes below via ProfiBus. The models for operating with absolute specifications are as follows. Actuator 1 Model/ RCA-RA3D~ 33 Actuator 2 Model/ RCP2-RA3C~ ProfiBus Gateway unit Model/ RGW-PR Actuator 1 Controller unit Model/ RACON-20 Simple absolute unit Model/ RABU Actuator 2 Controller unit Model/ RPCON-28SP Simple absolute unit Model/ RABU Operating mode explanation Operating mode explanation RoboNet operates under instructions received from the PLC via the field network. It can be used switching among the following three operating modes. Use the operating mode that best suits the device operation details and control method. Name Contents 1 Positioner mode This mode operates by specifying the position number. The position data, velocity, acceleration, etc. are input for each position ahead of time. Up to 768 positions can be registered. 2 Simple direct value mode This mode operates by directly specifying only the position data and specifying other data – velocity, acceleration, position width, electrical current limit for pressing – with the position number. Up to 768 positions can be registered. 3 Direct numeric value specification This mode operates by directly specifying the numeric values for the position data, velocity, acceleration, position width, and electrical current limit for pressing. There is no limit on the number of position points that can be specified numerically. List of Functions by Operating Mode Positioner mode Number of positions registered Simple direct value mode 768 points 768 points _ ? Movement by specifying position number Direct specification of position data Direct specification of velocity and acceleration Direct specification of positioning width Pressing operation _ (Specified with position table) _ _ (Specified with position table) _ (Specified with position table) Direct numeric value specification _ _ (Specified with position table) (Specified with position table) (Specified with position table) _ Completion position number monitor Zone output monitor Position zone output monitor _ Teaching functions _ _ Jog operations Incremental moves Status signal monitor (*) Current position monitor (*) Alarm code monitor (*) Velocity and electric current monitor (*) Maximum value for specification of position data Number of axes that can be connected _ _ 9999.99mm 9999.99mm 9999.99mm 16 16 8 * The status signal monitor, current position monitor, alarm code monitor, and velocity and electric current monitor can monitor by accessing each address of the GatewayR unit from the PLC. 4 Component unit explanation (GatewayR unit) ■ Component unit explanation GatewayR unit (DeviceNet specifications) This is the communications unit for operating RoboNet via DeviceNet. Model RGW-DV Specifications Item Specifications Item DeviceNet specifications Current consumption 600 mA max. Uses DeviceNet 2.0 certified interface module DeviceNet specifications Communications Group 2 only server standard Insulated node operating with network power supply 500kbps Communications Cable length 250kbps (*1) 125kbps Environmental conditions Polling * 1 For T branch communications, refer to the user's manuals for the master unit and for the PLC used. 100m 39m 6m 250m 500m 78m 156m Note: When thick DeviceNet cable is used Bit strobe Communications Master-satellite specifications Connection Cyclic Communications 500k/250k/125kbps (switched with dedicated software) speed Number of nodes occupied Usage ambient temperature Usage ambient humidity Usage atmosphere 1 node 0~40°C 95% RH max. (no condensation allowed) There must be no corrosive gas, combustible gas, oil mist, or dust. Protection rank IP20 Weight 140g Accessories Terminal resistance board (Model TN-1) Network connector/emergency stop connector Network connector Compatible wire for cable side connector Gateway side connector MSTBA2.5/5-G-5.08 ABGY AU (Made by Phoenix Contact) Cable side connector MSTB2.5/5-ST-5.08 ABGY AU (Made by Phoenix Contact) = Standard accessory Specifications Communications Maximum Maximum branch Total branch speed network length line length line length DC24V ±10% Power supply Pin colors Black Blue Explanation Item Power cable - side Compatible wire diameter Communications data Low side Peeled wire length Shield Black Blue White Red White Red Communications data High side Contents Braided wire AWG24-12 (0.2~2.5 mm²) 7mm Power cable + side GatewayR unit CC-Link specifications This is the communications unit for operating RoboNet via CC-Link. Model RGW-CC Specifications Specifications Current consumption Communications standard Communications speed Communications technique Synchronization technique Encoding technique Transmission path format Transmission format 600 mA max. CC-Link Ver2.0 (* 1) 10M/5M/2.5M/625k/156kbps (switched with dedicated software) Broadcast polling technique Frame synchronization technique NRZI Bus format (complies with EIA RS485) Complies with HDLC *1 Certification acquired *2 For T branch communications, refer to the user's manuals for the master unit and for the PLC used. Network connector Gateway side connector MSTBA2.5/5-G-5.08AU (Made by Phoenix Contact) DA 55 DB DG SLD Cable side connector MSTB2.5/5-ST-5.08 ABGY AU (Made by Phoenix Contact) = Standard accessory FG Signal name Explanation DA Communications line A DB Communications line B DG Ground SLD Connect the shield and cable shield to the frame ground and chassis. FG Connect the frame ground to the shield and the chassis Item Specifications Error control CRC (X¹⁶+X¹²+X⁵+1) technique Number of stations occupied Remote device stations 1x 4 stations, 4x 2 stations, 8x 2 stations Communications 10M 5M 2.5 M 625k 156k Communications speed (bps) cable length Total cable 100 160 400 900 1200 (*2) length (m) Communication Special CC-Link cable cable Usage ambient temperature 0~40°C Usage ambient 95% RH max. (no condensation allowed) humidity Usage There must be no corrosive gas, combustible gas, oil mist, or dust. atmosphere Environmental conditions CC-Link specifications DC24V ±10% CC-Link specifications Item Power supply Protection rank IP20 Weight 140g Accessories Terminal resistance board (Model TN-1) Network connector/emergency stop connector Terminal resistance cable (110Ω/130Ω) Compatible wire for cable side connector Item Contents Braided wire Compatible wire diameter AWG24-12 (0.2~2.5 mm²) Peeled wire 7mm length Component unit explanation (GatewayR unit) GatewayR unit (ProfiBus specifications) This is the communications unit for operating RoboNet via ProfiBus. Model RGW-PR Specifications Item Specifications Power supply Environmental conditions DC24V ±10% ProfiBus specifications Current consumption 600 mA max. Communications DP satellite standard Communications 9.6kbps~12Mbps speed Communications cable length Item Specifications Usage ambient temperature 0~40°C Usage ambient 95% RH max. (no condensation allowed) humidity Usage atmosphere There must be no corrosive gas, combustible gas, oil mist, or dust. Protection rank IP20 9.6kbps 1500m Weight 140g 500kbps 400m Accessories Terminal resistance board (Model TN-1) Emergency stop connector 1.5Mbps 200m 3Mbps 200m 12Mbps 100m Network connector Gateway side connector: D-Sub 9-pin connector Socket side 5 1 Pin No. Signal name 9 6 Explanation Pin No. Signal name Communications line B (RS485) B-Line 4 RTS Request to send 5 GND Signal ground (insulated) * The partner side connector (D-sub 9-pin connector) does not come as an accessory. Explanation +5V output (insulated) 6 +5V 8 A-Line Communications line A (RS485) Housing Shield The cable shield is connected with the chassis. * Pins 1, 2, 7, and 9 are not connected. GatewayR unit SIO specifications This is the communications unit for operating RoboNet with serial communications from an XSEL controller (*1) or Modbus communications unit. *1 A unit with XSEL Gateway functions is scheduled for release soon. Model RGW-SIO Specifications Specifications Power supply Current consumption Communications format Communications technique Communications speed Cable length Recommended cable DC24V ±10% 600 mA max. RS485 compliant (Modbus protocol) 1:1 communication connection Stop-start system Half duplex Environmental conditions SIO specifications Item Specifications 0~40°C 95% RH max. (no condensation allowed) There must be no corrosive gas, combustible gas, oil mist, or dust. IP20 230.4 kbps max. Weight 140g 100 m max. Accessories Terminal resistance board (Model TN-1) Network connector/emergency stop connector 2-pair twisted pair cable (with shield) Compatible wire for cable side connector Network connector Gateway side connector MC1.5/4-G-3.5 (Made by Phoenix Contact) Cable side connector: MC1.5/4-ST-3.5 (Made by Phoenix Contact) = Standard accessory Item Usage ambient temperature Usage ambient humidity Usage atmosphere Protection rank Signal name FG SG SB SA Explanation SA Communications line A (+ side) RS485 compliant SB Communications line B (- side) board (220 Ω) built in SG Signal ground FG The frame ground is connected with the chassis. Terminal resistance Item Contents Braided wire Compatible wire diameter AWG28-16 (0.14 ~ 1.5 mm2) Peeled wire length 7mm 6 Component unit explanation (controller unit) ■ Component unit explanation RACON unit RCA series controller This is the controller unit for operating an RCA actuator with RoboNet. Model RACON--  Motor output (W)  Optional integrated absolute unit (ABU) Explanation model items: Controller model Supported actuators RACON-20- RCA-SA4□ / SS4□ / SA5□ / SS5□ / RA4□ -20 / RG□ 4 □ -20 / A4R / A5R RCACR-SA4C / SA5□ RCAW-RA4□ -20 RACON-20S- RCA-RA3□ / RG□ 3 □ RACON-30- RCA-SA6 □ / SS6□ / RA4□ -30 / RG□ 4 □ -30 / A6R RCACR-SA6 □ RCAW-RA4□ -30 RCAW-RA3□ Specifications Item Specifications DC24V ±10% Power supply capacity Operating actuator Number of positioning points 5.1 A max. (depends on actuator) 768 points Backup memory EEPROM RCA series Position detection Incremental encoder technique Electromagnetic brake forced release Brake release switch Motor cable Model CB-ACS-MA□□□ Encoder cable Model CB-ACS-PA□□□ Environmental conditions General specifications Item Power supply Specifications Usage ambient temperature Usage ambient humidity Usage atmosphere 95% RH max. (no condensation allowed) There must be no corrosive gas, combustible gas, oil mist, or dust. Protection rank IP20 0~50°C Weight 200g Accessories RoboNet communication connection board (JB-1 model) Power supply connection board (PP-1 model) RPCON unit RCP2 series controller This is the controller unit for operating an RCP2 actuator (*1) with RoboNet. Model RPCON-- Explanation model items:  Motor output (W)  Optional integrated absolute unit (ABU) Controller model Supported actuators RPCON-20P RCP2-RA2C (*2) / GRS (*2) RPCON-28P- RCP2-GRM / GR3LS / GR3SS / RTB (*2) / RTC (*2) RPCON-28SP- RCP2-RA3C / RGD3C RPCON-42P- RCP2-SA5□ / SA6 □ / SS7 □ / BA6 □ / BA7 □ / RA4C / RG □ 4C / GR3LM / GR3SM RCP2CR-SA5C / SA6C / SS7C RCP2W-RA4C RPCON-56P RCP2-SA7□ / SS8□ / RA6C / RG6□ C RCP2CR-SA7C / SS8C RCP2W-RA6C *1 This controller can also operate an old-type RCP2 actuator. (Please inquire for details.) *2 Controller models with integrated absolute unit (item ) are not available for RCP2-RA2C / GRS / RTB / RTC. Specifications 7 Item Specifications DC24V ±10% Power supply capacity 2 A max. Operating actuator RCP2 series Number of positioning points 768 points Backup memory EEPROM Position detection technique Incremental encoder Electromagnetic brake forced release Brake release switch Motor cable Model CB-RCP2-MA□□□ Encoder cable Model CB-RCP2-PA□□□ Environmental conditions General specifications Item Power supply Usage ambient temperature Usage ambient humidity Usage atmosphere Protection rank Weight Accessories Specifications 0~50°C 95% RH max. (no condensation allowed) There must be no corrosive gas, combustible gas, oil mist, or dust. IP20 200g RoboNet communication connection board (JB-1 model) Power supply connection board (PP-1 model) Component unit explanation (Absolute R / Extension unit) Simple absolute R unit This is a data backup battery unit that is connected to a RACON/RCPON unit (*1) to allow incremental specifications actuators to be used as absolute specifications actuators. *1 One simple absolute R unit is required for each RACON/RPCON unit. Model RABU (Common to RACON/RPCON) Specifications Specifications Item DC24V ±10% Current consumption 300 mA max. Battery used Nickel metal hydride battery (Ni-MH) Charge time About 78 hours Battery life 3 years Environmental conditions General specifications Item Power supply Specifications Usage ambient temperature Usage ambient humidity Usage atmosphere There must be no corrosive gas, combustible gas, oil mist, or dust. Protection rank IP20 0~40°C 95% RH max. (no condensation allowed) 330g Weight Can store absolute data Maximum rotation rate (rpm) 800 400 200 100 Absolute data storage time (h) 120 240 360 480 RoboNet communication connection board (JB-1 model) Simple absolute specifications connection board (JB-1 model) Power supply connection board (PP-1 model) Accessories Extension unit This is an extension unit for connecting many RoboNet units in two lines by a communication cable when there is space limit. Also it enables to operate single controller such as SCON or PCON-CF on network by connecting a link cable between the last extension unit and a wire from controller. Model REXT (Common to RACON/RPCON) Specifications Item Specifications DC24V ±10% Current consumption Usage ambient temperature Usage ambient humidity Usage atmosphere 100 mA max. Environmental conditions Power supply Protection rank 0~40°C 95% RH max. (no condensation allowed) There must be no corrosive gas, combustible gas, oil mist, or dust. IP20 Weight 140g Accessories RoboNet communication connection board (JB-1 model) Power supply connection board (PP-1 model) REXT-SIO (Standard extension for more RoboNet units) REXT-CTL (Special extension for SCON or PCON-CF controllers) Field network Field network Extension unit [REXT-CTL] Extension unit [REXT-SIO] PLC Extension unit communication cable (1 m) [CB-REXT-SIO010] FG RACON RPCON FG Extension unit [REXT-SIO] Extension unit link cable (1 m) [CB-REXT-CTL010] E-Con connector junction kit * e-CON FG e-CON PLC SCON PCON-CF Controller link cable (0.2 m) [CB-RCB-CTL002] * The user must provide the wiring between junctions. 8 External dimensions / Options External dimensions diagram GatewayR unit/RACON unit/RPCON unit/simple absolute R unit all share the same external dimensions. (160) (50 from the DIN rail center) 100 35.4 Top view: Bottom view: 5 (69.3 from the DIN rail surface) 34 73.3 RCM-E 66.6 ■ Model 46.9 7 72.5 (34) * no CE mark CON-T-ENG RCM-E (*) RCM-P (*) Data input ○ ○ ○ Actuator operation Usage ambient temperature and humidity Usage atmosphere ○ ○ - Protection rank 5m 140 148. 5 218. 3 ■ Configuration Weight Temperature 0 to 40˚C Relative humidity 85% max. No corrosive gas allowed. Dust must not be particularly bad. IP54 - - About 400g About 400g About 360g 5m Cable length Display 20-character by 4-line LCD display 16-character by 2-line LCD display 16-character by 2-line LCD display PC software (for Windows only) ■ Features This is startup support software equipped with program/position input, test run, monitor, and other functions. It increases functions required for debugging operations and contributes to shortening the start-up time. ■ Model RCM-101-MW-EU (with external device communications cable + RS232 converter unit) ■ Configuration RS232 converter adaptor RCB-CV-MW 5m 0.3m PC software (CD) ■ Model RCM-101-USB-EU USB converter adaptor RCB-CV-USB 1m PC software (CD) 9 External device communication cable CB-RCA-SIO050 (with external device communications cable + USB cable) ■ Configuration USB cable CB-SEL-USB010 23 39.0 CON-T-ENG (standard type, with CE/ANSI mark) RCM-E (simple teaching box, no CE mark) ■ Specifications RCM-P (data setting unit, no CE mark) Item 89.6 86 15.1 26.2 6.3 Teaching box ■ Features This is a teaching device equipped with position input, test run, monitor, and other functions. RCM-P (113.5) 43 110.0 21 CON-T-ENG Options 23. 5 (0.5) (10) * Can be installed on DIN rail (35 mm) 5m External device communication cable CB-RCA-SIO050 Maintenance parts Maintenance parts When it is necessary to make arrangements for a replacement cable or the like after product purchase, find the model below. RoboNet communication connection board (simple absolute connection board) Model JB-1 RACON motor cable Model Terminal resistance board Model TN-1 Power supply connection board Model PP-1 Motor cable CB-ACS-MA * For  enter the cable length (L), up to 20 meters. Example: 080=8 meters L 1 3 Controller side Wire 3 AWG22 (press fit) Machine side RACON encoder cable Model 1 Color Signal NO Red U 1 White V 2 Black W 3 NO Signal Color 1 U Red 2 V White 3 W Black Wire AWG22 (press fit) Encoder cable/encoder robot cable * The standard encoder cable is the normal cable. A robot cable is available as an option. * For  enter the cable length (L), up to 20 meters. Example: 080=8 meters CB-ACS-PA/CB-ACS-PA-RB CN1 CN2 Cable color Robot cable Standard cable Blue White/purple Orange White/gray Green Yellow Brown Blue Gray White/blue Red White/yellow Black White/red Yellow White/black Pink Orange Purple Green White Purple Blue/red Gray Orange/white Red Green/white Black L 20 1 18 17 2 1 9 Controller side 10 18 Signal abbrev. LS+ LSBK+ BKENA ENA ENB ENB ENZ ENZ VPS 5V GND Machine side Drain Drain F.G Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Pin No. 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Model White/purple Drain Orange Green Purple Gray Red Black White/gray Blue Yellow * The standard motor cable is a robot cable. * For  enter the cable length (L), up to 20 meters. Example: 080=8 meters M cable CN3 C N 1 CN3 (Front diagram) (Front diagram) L I-1318119-3 (AMP) Machine side Orange Gray White Yellow Pink Yellow (Green) A VMM B A VMM B A1 A2 A3 B1 B2 B3 CN1 1 2 3 4 5 6 Yellow A Gray VMM Orange A Yellow (Green) B Pink VMM White B SLP-06V (JST) Encoder cable/encoder robot cable RPCON encoder cable Model Drain Pink Purple ENZ White Blue/red VPS 5V Orange/white GND Green/white Orange LSBrown BKGreen BK+ FG ENZ Motor cable CB-RCP2-MA Controller side Blue LS+ Plug housing: XMP-18V (JST) Socket contact: BXA-001T-P0.6 (JST) Retainer: XMS-09V (JST) Housing: PHDR-18VR (JST) Contact: SPHD-001T-P0.5 (JST) RPCON motor cable Cable color Signal abbrev. Standard cable Robot cable White/blue Gray ENA White/yellow Red ENA White/red Black ENB White/black Yellow ENB CB-RCP2-PA/CB-RCP2-PA-RB * The standard encoder cable is the normal cable. A robot cable is available as an option. * For  enter the cable length (L), up to 20 meters. Example: 080=8 meters CN2 C N 2 CN4 (Front diagram) (Front diagram) Controller side 5 Signal Cable color Robot cable Standard cable abbrev. L Machine side Purple White (vs. purple) Blue White (vs. blue) Yellow White (vs. yellow) Red Gray Brown Green Purple Pink Green Red White (vs. red) Yellow Orange Blue Drain Drain Housing: PHDR-16VS (JST) Contact: SPHD-001T-P0.5 Pin No. 16 15 14 13 12 11 ENA ENB 10 9 ENB (Reserved) 8 VPS 7 5V 6 GND 5 4 3 2 F.G 1 LS+ LSBK+ BKENA CN1 Signal abbrev. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Cable color Pin No. Standard cable Robot cable Brown Blue Green White (vs. blue) ENA Purple Yellow ENB Pink White (vs. yellow) ENB ENA GND 5V VPS Blue Orange Yellow White (vs. red) Red Green BK+ BKF.G Red Gray Drain Purple White (vs. purple) Drain Housing: XMP-18V (JST) Contact: BXA-001T-P0.6 Retainer: XMS-09V Please ask IAI for special cables of new RoboCylinder series RCP3 (CB-PCS-MPA) and RCA2 (CB-ACS-MPA) or of extension unit REXT-SIO (CB-REXT-SIO010) and REXT-CTL (CB-REXT-CTL-010). 10 RoboNet Series Catalogue No. 1107-E Providing quality products since 1986 The information contained in this catalog is subject to change without notice for the pupose of product inprovement IAI Industrieroboter GmbH Ober der Röth 4 D-65824 Schwalbach / Frankfurt Germany Tel.:+49-6196-8895-0 Fax:+49-6196-8895-24 E-Mail: [email protected] Internet: http://www.eu.IAI-GmbH.de IAI America Inc. IAI CORPORATION 2690 W. 237th Street, Torrance, CA 90505, U.S.A Tel.: +1-310-891-6015 Fax: +1-310-891-0815 645-1 Shimizu Hirose, Shizuoka 424-0102, Japan Tel.: +81-543-64-5105 Fax: +81-543-64-5182 IAI, the IAI-logo, RoboCylinder™, the RoboCylinder™-logo, IntelligentActuator™ and the IntelligentActuator™-logo are trademarks or product names of IAI Corporation or of the subsidiaries in USA or Germany