Preview only show first 10 pages with watermark. For full document please download

Rohs Compliant Tx-1310/rx-1490,1244mbps Upstream/2488mbps

   EMBED


Share

Transcript

RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Features „ Compliant with ITU-T G.984.2 CLASS B+/C+ „ Compliant with SFF8472 diagnostic monitoring interface „ Industry standard 2×10 footprint „ SC/APC connector „ DC/AC Coupling Data In/Out Interface „ Transmitter burst mode and Receiver continuous mode „ Compatible with solder and aqueous wash processes „ Class 1 laser product complies with EN 60825-1 Ordering Information Part Number LSF2-C3M-TC-N3-HD LSF2-C3M-TI-N3-HD Page 1 of 11 Version 1.1 Date:12/17/2013 TX RX IN/OUT SD Burst Control 1310 1490 nm DC/AC LVTTL 1490 nm DC/AC LVTTL nm 1310 nm RX 1550nm Input Temperature Connector LVTTL (Enable: Logic “1”) Blocked 0 °C to 70 °C SC/APC LVTTL (Enable: Logic “1”) Blocked -40 °C to 85 °C SC/APC Website: www.apacoe.com.tw RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Diagnostics Parameter Range Accuracy Unit Temperature -40 to 95 ±3 Voltage 3.0 to 3.6 ± 0.1 V Bias Current 0 to 100 ± 10% mA TX Power -3 to +7 ± 3 dB dBm RX Power -28 to -8 ± 3 dB dBm o Calibration C Internal Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature TS −40 85 °C Operating Ta -40 85 °C Vcc 0 4.0 V Soldering Temperature TSOLD --- 260 °C Optical Input Power (Peak, 1550nm) P1650 +10 dBm Optical Input Power (Peak, 1650nm) P1650 +10 dBm Optical Input Power (average, 1490nm) Pin +2 dBm Case Temperature Supply Voltage Note 10 seconds on leads Operating Environment Parameter Symbol Min. Max. Unit Case Operating Temperature TC 0 -40 70 85 °C Supply Voltage Vcc 3.135 3.465 V Supply Current(B.O.L) ITX + IRX --- 350 mA Supply Current(E.O.L) ITX + IRX --- 400 mA Humidity (without dew) RH 5 95 % RH Page 2 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw Note RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Transmitter Electro-optical Characteristics Vcc = 3.135 V to 3.465 V, TC = 0 °C to 70 °C ( -40 °C to 85 °C ) Parameter Symbol Min. Typ. Max. Unit Note Output Optical Power (BOL) 9/125 μm fiber (Average) Output Optical Power (EOL) Pout +1 +5 dBm 9/125 μm fiber (Average) Pout +0.5 +5 dBm Extinction Ratio ER 10 --- --- dB Center Wavelength λC 1290 1310 1330 nm Spectral Width (-20dB) Δλ 1 nm SMSR 30 dB 260 ps Side Mode Suppression Ratio Rise/Fall Time (20−80%) Tr, f --- Output Eye Average Launched power of OFF --- Compliant with ITU-T G.984.2 POFF -45 dBm TX Burst off /Disable Assert Time Ton 12.8 ns 16bit TX Burst off/Disable Negate Time Toff 12.8 ns 16bit -6 dB λ=1310nm -15 dB transmitter Transmitter reflectance Tolerance to the transmitter incident light power Tot TX Burst off /Disable Voltage-High VIH 2.0 --- VCC V LVTTL TX Burst off /Disable Voltage-Low VIL 0 --- 0.8 V LVTTL Data Input Voltage - High VIH Vcc-1.1 --- Vcc-0.6 V LVPECL DC coupled inputs VIL Vcc-1.9 --- Vcc-1.6 V Data Input Voltage – Low Page 3 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw LVPECL DC coupled inputs RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Table 1: Optical output operation Item Input & Condition DATA TXOFF 1 Normal data 2 Logical High Enable Continuation 3 Logical Low Continuation 4 Same Level 5 X Disable Output Optical output *1 ON Other Other Other OFF X=Do not care(include Same level) *1: ON=Optical output, OFF=Less than –45dBm, Other= Less than +8dBm(peak) TX_SD function Page 4 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Receiver Electro-optical Characteristics Vcc = 3.135 V to 3.465 V, TC = 0 °C to 70 °C ( -40 °C to 85 °C ) Parameter Optical Input Saturation Power (Overload) Symbol Min. Typ. Max. Unit Note PIN -8 --- --- dBm Note1 Optical Input Power-minimum (Sensitivity-Class B+),BER< 1.0x10-10 Optical Input Power-minimum (Sensitivity-Class C+),BER< 1.0x10-4 PIN --- --- −28 dBm Note1 PIN --- --- −30 dBm Note4 Operating Center Wavelength λC 1480 1490 1500 nm Optical isolation (1260 ~1360nm) ISO --- --- -45 dB Optical isolation (1550 ~ 1560nm) ISO --- --- -25 dB Receiver reflectance (1480 to 1500nm) --- --- −12 dB Note2 Receiver reflectance (1550 to 1560nm) --- --- −20 dB Note3 Signal Detect-Asserted PA --- --- −28 dBm Signal Detect-Deasserted PD −44 --- --- dBm Signal Detect-Hysteresis PA − PD 0.5 --- --- dB Signal Detect Output voltage-High VOH 2.4 --- VCC V LVTTL Signal Detect Output voltage-Low VOL 0 --- 0.4 V LVTTL VDIFF 0.5 --- 1.8 V AC Coupled Data Output Amplitude (Differential) -10 23 Note1: With BER better than or equal to 1.0x10 ,measured in the center of eye opening with 2 -1 NRZ PRBS, and Extinction Ratio=10dB. Note2: Measured with 1490nm Note3: Measured with 1550nm Note4: With BER better than or equal to 1.0x10-4,measured in the center of eye opening with 223-1 NRZ PRBS, and Extinction Ratio=10dB. Page 5 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Connection Diagram Pin-Out 10 9 8 7 6 5 4 3 2 1 17 18 19 20 Top View 11 Pin Symbol 1 NC 2 RX GND 3 RX GND 4 5 NC NC 6 RX GND 7 VCCR 8 SD 9 RD– 10 RD+ 11 VCCT 12 TX GND 13 TXoff 14 TD+ Page 6 of 11 Version 1.1 Date:12/17/2013 12 13 14 15 16 Description Not Connected Receiver Signal Ground Directly connect this pin to the receiver ground plane. Internal connected to TX GND. Receiver Signal Ground Directly connect this pin to the receiver ground plane. Internal connected to TX GND. Not Connected Not Connected Receiver Signal Ground Directly connect this pin to the receiver ground plane. Internal connected to TX GND. Receiver Power Supply Provide +3.3 Vdc via the recommended receiver power supply filter circuit. Signal Detect. Normal optical input levels to the receiver result in a logic “1” output, VOH, asserted. Low input optical levels to the receiver result in a fault condition indicated by a logic “0” output VOL, de-asserted. Signal Detect is a single-ended LVTTL output. Receiver data output. AC coupled output RD- output will be muted when SD “Low” level. Receiver data output. AC coupled output RD+ output will be muted when SD “Low” level. Transmitter Power Supply Provide +3.3 Vdc via the recommended transmitter power supply filter circuit. Transmitter Signal Ground Directly connect this pin to the transmitter signal ground plane. Internal connected to RX GND. Transmitter Enable/Burst on Connect this pin to LVTTL logic high “1” to enable transmitter. To disable module connect to LVTTL logic low “0”. Transmitter Data In LVPECL, internally DC-coupled. Website: www.apacoe.com.tw RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) 15 TD– 16 TX GND 17 18 19 20 SCL SDA TX_Fault TX_SD Page 7 of 11 Version 1.1 Date:12/17/2013 Transmitter Data In-Bar LVPECL, internally DC-coupled. Transmitter Signal Ground Directly connect this pin to the transmitter signal ground plane. Internal connected to RX GND. Clock line of the I2C bus Data line of the I2C bus Assert high when transmitter fault. Assert high when transmitter on. Website: www.apacoe.com.tw RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Recommended Circuit Schematic 0.1uF 3.3V TX GND(12, 16, 20) 1uH VCCT(11) VCCR(7) 0.1uF 1uH 10uF GPON MAC RX GND(2, 3, 6) 0.1uF TX_BRST(13) 3.3V 130 PON_TX_DISABLE TD+(14) Z=50 TD-(15) 3.3V GPON MAC LD Driver 82 TXN Z=50 82 TXP 130 10uF 82 82 SerDes RXN RD-(9) 0.1uF Z=50 RD+(10) 0.1uF 130 LIA 3.3V 10K 130 RXP Z=50 PON_LOS PON_SDA PON_SCL Page 8 of 11 Version 1.1 Date:12/17/2013 SD(8) SDA(18) SCL(17) Website: www.apacoe.com.tw Controller RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Recommended Board Layout Hole Pattern Unit : mm(inches) Page 9 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) 12.5Max 9.05 48.20 13.50 8.89±0.1 1.1Max 9.50 Max 12 Max 4.75±0.1 5.5 Drawing Dimensions L 1.0±0.1 24.16 4.55 0.30 3.3±0.3 39 Max 1.0±0.1 26.70 0.45±0.10 1.78 L=160 (+/-20) unit : mm Page 10 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw 0.3±0.05 10.16 RoHS Compliant TX-1310/RX-1490,1244Mbps upstream/2488Mbps downstrean 2×10 Pigtail SC/APC Connector, 3.3 V, with Digital Monitoring G-PON ONU , Class B+/C+ (G984.2) Eye Safety Mark The LSF series Single mode transceiver is a class 1 laser product. It complies with EN 60825-1 and FDA 21 CFR 1040.10 and 1040.11. In order to meet laser safety requirements the transceiver shall be operated within the Absolute Maximum Ratings. Required Mark Class 1 Laser Product Complies with 21 CFR 1040.10 and 1040.11 Caution All adjustments have been done at the factory before the shipment of the devices. No maintenance and user serviceable part is required. Tampering with and modifying the performance of the device will result in voided product warranty. Note : All information contained in this document is subject to change without notice. Page 11 of 11 Version 1.1 Date:12/17/2013 Website: www.apacoe.com.tw