Preview only show first 10 pages with watermark. For full document please download

Room Air Conditioner Svc Manual(exploded View)

   EMBED


Share

Transcript

Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : US-W093WSA5 US-W123BSA5 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. Specifications Product Specifications Buyer Model (Indoor Unit / Outdoor unit) Factory Model (Indoor Unit / Outdoor unit) Cooling Capacity (Min ~ Rated ~ Max) Heating Capacity (Min ~ Rated ~ Max) Maximum Heating Capacity Power Input Running Current Starting Current EER SEER COP HSPF (Ⅳ / Ⅴ) a) Power Supply Power Factor Air Flow Rate Moisture Removal Sound Level Compressor Fan(Indoor) Fan(Outdoor) Outdoor 17ºF (Indoor 70ºF) Outdoor 5ºF (Indoor 70ºF) Outdoor -4ºF (Indoor 70ºF) Cooling / Heating Cooling / Heating Cooling / Heating Indoor,Max/H/M/L Outdoor,Max Indoor,H/M/L/SL (Cooling) Indoor,H/M/L (Heating) Outdoor,Max Type Model Motor Type Oil Type Oil Charge O.L.P. name Type Motor Output Type Motor Type Motor Output Circuit Breaker* Power Supply Cable Power and Transmission Cable Liquid Side Piping Connections Gas Side Drain Hose(O.D , I.D.) Dimensions Net Weight Gross Weight Operation Range Indoor (W × H × D) Outdoor (W × H × D) Indoor Outdoor Indoor Outdoor Unit kW Btu/h kW Btu/h Btu/h Btu/h Btu/h W A A Ø / V / Hz % CFM (㎥/min) CFM (㎥/min) pts/h (l/h) dB(A)+3 dB(A)+3 dB(A)+3 cc W W A No. × AWG No. × AWG in (mm) in (mm) in (mm) mm inch mm inch lbs (kg) lbs (kg) lbs (kg) lbs (kg) Cooling (Outdoor) ℉(℃) DB Heating (Outdoor) ℉(℃) DB oz (g) oz/ft (g/m) ft (m) ft (m) ft (m) LS-090HEV1 LS-120HEV1 (LSN090HEV1 / LSU090HEV1) (LSN120HEV1 / LSU120HEV1) US-W093WSA5 US-W123BSA5 (USNW093WSA5 / USUW093WSA5) (USNW123BSA5 / USUW123BSA5) 0.30 ~ 3.52 ~ 4.03 0.90 ~ 2.49 ~ 2.78 1,020 ~ 12,000 ~ 13,780 3,070~8,500~9,500 0.30 ~ 3.52 ~ 4.03 0.90 ~ 2.64 ~ 3.08 1,020 ~ 12,000 ~ 13,780 3,070~9,000~10,500 5,570 (62%) 7,620 (63%) 680/780 1,140/980 3.2/3.6 5.2 / 4.4 3.2/3.6 5.2 / 4.4 12.50 10.52 19.0 17.0 11.54 12.24 9.0 / 7.82 9.2 / 8.0 1 / 208-230 / 60 1 / 208-230 / 60 92.4 95.3 318 (9) / 276 (8) / 226 (6) / 177 (5) 953 (27) 2.12 (1.0) 39 / 33 / 25 / 19 39 / 33 / 25 47 1P Rotary GA102MDB Brushless DC Motor PVE or POE 310 Cross Flow Fan 20 Propeller Fan BLDC 43 15 3 × 14 4 × 18 Φ 1/4 (6.35) Φ 3/8 (9.52) 27/32, 5/8 (21.5, 16.0) 756 × 265 × 184 29-3/4 × 10-7/16 × 7-1/4 717 × 483 × 230 28-1/4 × 19-1/32 × 9-1/16 16.3 (7.4) 61.7 (28) 19.6 (8.9) 66.1 (30) 14 ~ 118 (-10 ~ 48) 14 ~ 75 (-10 ~ 24) R410A / 30.0 (850) 0.22 (20) 9.8 (3) / 49.2 (15) 24.6 (7.5) 23 (7) SW + UA3+ Thermistor O O O 3/4/4 Auto Manual Wireless LCD 64~86 (18~30) 60~86 (16~30) O O 24h, On/Off O O 3 O O O O Water Level Sensor Refrigerant & Charge Additional Refrigerant Charge Piping Length (Min/Max) Chargeless Max. Elevation Difference Tool Code(Chassis) Indoor + Outdoor Temperature Control Allergy Safe filter Plasma Filter Prefilter (Washable/Anti-fungus) 3M Micro Protection filter Auto Clean Natural Wind (Auto Wind) Steps, Fan/Cool/Heat Airflow Direction Control(Up& Down) Airflow Direction Control(Left & Right) Remote Controller Type Cooling[℉ (℃)] Setting Temperature Range (℃)] (℃)] Functions Heating[℉ Auto Operation (Micom Control) Auto Changeover (Micom Control) Self Diagnosis Timer Sleep Operation Soft Dry Operation Restart Delay (Minute) Deice Control (Defrost) Hot Start Jet Cool / Jet Heat Low Ambient Operation Special Function Note: O : Applied, - : No relation * For circuit breaker rating, please conform to local standards wherever necessary. Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -2- 424 (12.0) / 353 (10.0) / 272 (8) / 212 (6) 953 (27) 2.76 (1.3) 39 / 33 / 25 / 19 39 / 33 / 25 47 1P Rotary GA102MDB Brushless DC Motor PVE or POE 310 Cross Flow Fan 20 Propeller Fan BLDC 43 15 3 × 14 4 × 18 Φ 1/4 (6.35) Φ 3/8 (9.52) 27/32, 5/8 (21.5, 16.0) 885 × 285 × 210 34-13/16 × 11-1/4 × 8-1/4 717 × 483 × 230 28-1/4 × 19-1/32 × 9-1/16 22.5 (10.2) 61.7 (28) 27.3 (12.4) 66.1 (30) 14 ~ 118 (-10 ~ 48) 14 ~ 75 (-10 ~ 24) R410A / 31.7 (900) 0.22 (20) 9.8 (3) / 49.2 (15) 24.6 (7.5) 23 (7) SB + UA3+ Thermistor O O O 3/4/4 Auto Manual Wireless LCD 64~86 (18~30) 60~86 (16~30) O O 24h, On/Off O O 3 O O O O Water Level Sensor Some of functions are slightly different depending upon models. The specification may be subject to change without notic for purpose of improvement. LGE Internal Use Only Piping Diagrams Piping Diagrams Model : US-W093WSA5 / US-W123BSA5 Indoor Unit Outdoor Unit FIELD PIPIN G (Ø 1/4” Copper Tubing) 2-Way Valve Liquid Side EEV M Th1 Th5 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) M Th3 Th2 3-Way Valve FIELD PIPIN G (Ø 3/8” Copper Tubing) Reversing Valve Th6 Gas Side Accumulator Th4 : Cooling : Heating Compressor LOC Description PCB Connector Th1 Thermistor for indoor air temperature CH-TH1(Indoor) Th2 Water level sensor (Option) CH-TH2(Indoor) Th3 Thermistor for evaporator middle temperature CH-TH3(INDOOR) Th4 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR) Th5 Thermistor for outdoor air temperature Th6 Thermistor for condensing temperature Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- CN-TH1(OUTDOOR) LGE Internal Use Only Wiring Diagrams Wiring Diagrams Indoor Unit USNW093WSA5 USNW123BSA5 Option Option CN-L1 CN-L1 MEZ64835113 MEZ64835111 CN-IN/N1 CN-L1 CN-U/D CN-DISP3 CN-DISP1 CH-TH1 CH-TH2 CH-TH3 CN-COM Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -4- LGE Internal Use Only Wiring Diagrams Outdoor Unit (USUW093WSA5 / USUW123BSA5) Option MEZ64835112 CN-TH2 CN-TH1 CN-EEV CN1 CN-LGMV CN-4WAY CN-CENTRAL CN-JTAG CN-FLASH CN-COIL1 WCN-P(L) WCN-P(N) CN-COIL2 Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -5- LGE Internal Use Only Exploded View Exploded View Indoor Unit • Model: USNW093WSA5 135316 237202 135511 733010 152302 131111 131410 267110 149304 342800 149303 359011 354212 146811 135090 354210 352150 249951 346810 135516 W50400 268711B 35211B 145200 147582 268711D 263230A 135311 147581 LOC. 263230A 263230B Description Thermistor for indoor air temperature Thermistor for evaporating temperature Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -6- W6640 263230B PCB Connector CN-TH1(Indoor) CN-TH3(Indoor) LGE Internal Use Only Exploded View • Model : USNW123BSA5 135316 152302 135511 131111 131410 135303 149303 733010 149304 342800 135500A 267110 359011 354212 135080 354210 146811B 346810 352150 263230B 268711C W50400 135516 147582A 145200 135311 147582B LOC. 263230A 263230B W6640A 35211B 263230A 268711D 249951 147581 Description Thermistor for indoor air temperature Thermistor for evaporating temperature Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -7- PCB Connector CN-TH1(Indoor) CN-TH3(Indoor) LGE Internal Use Only Exploded View Outdoor Unit 552116 561410 W1WE W6631 W4986C 550140 W6640B 152503 447910 554160 W4986A W4986B 437211 435301 237202 430410 559010 137213A 546810 261704 549610 554031 263230A 263230B 649950 148000 268711F 55211G 552203B 552203A 552202 135500C 435511B 137213B 552112 661400 552200A • Model : USUW093WSA5 / USUW123BSA5 LOC. 263230A 263230B Description Thermistor for air temperature Thermistor for condenser middle temperature Thermistor for discharge temperature Copyright ©2015 LG Electronics. Inc. All right reserved. Only for training and service purposes -8- LGE Internal Use Only P/NO : MFL67880961 February, 2015