Preview only show first 10 pages with watermark. For full document please download

Room Data Sheet

   EMBED


Share

Transcript

ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Meeting Room Large Second Door Style GO BUILDING Width Area & Volume Height Area Requirements 60.0m2 Minimum Height 2400 or L= W= 2700 Hardware 3000 other Special reqts 24/10/11 SCWD HM/paint Alum Other A B C Other 860 x 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Special Requirements Windows Exterior Noise Attenuation & Vibration Control Room Acoustic Rating Special Requirements 35-40 40-50 Interior 45-50 55 Covering RC 25-30 Exterior Glazing Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special Reqts Walls Rubber Carpet Slip Resistant Drywall Min Area 2 V-Blinds m H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level CT/QT self Millwork Use elevations reference Drawing # Specialities White Boards x 2 Wood Other Plywood m2 Special reqts Other Cove/Base Min Area Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Outlets Other Drywall/painted Open Structure Special Reqts Primary Door Style Width Height Hardware Special reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x 8 Intercom x Public Address Audio Video Presentation equipment Other SCWD HM/paint Alum A B C Other Other 1100 x 860 x1 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Voice x 8 Side Lights Lock set Passage No 300x2135 Security Ceiling Mount Floor Connection Wall connection Special Requirements 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 24/10/11 Number of Occupants General Information Room/ Functions Meeting Room Large Heat producing Equipment (list number of devices) GO BUILDING Building Normal Maximum 40 60 Computers x8 Small Xerox Printers x Large Xerox Other Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Plumbing Minimum regular receptacles is 1 /per1 m at above counter areas Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Regular (15 AMP) Room Power Supply Lighting Sinks QTY QTY Computer(Surge Protected) QTY 4 QUAD Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 Standard Emergency stainless steel sink Type Regular (20 AMP) Type 110 320 Special/custom Size 750 Dimmable Incandescent/LED Dimmable Other features General lighting to have multiple zones and controls 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Heating Air Conditioning Smudging /Smoke Extraction Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) W= D= basic goose neck single lever double lever Hands free Shower grease trap extra water quick disconnect wing handles Other: Toilet x Urinal x Hose bibb connect x Soap Dispenser x Paper Towel Dispenser x Soap Dispenser (hands free) x special Mirror and shelf x Drainage No Preference L= Shower x Accessories Mechanical and HVAC Dedicated Thermostat Other fixtures 1100 bulk head desk No wall mount spray wand General Lighting to have dual levels controlled by switching Task deep other Plumbing is for future development only Faucet Set Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Plumbing drain and vent rough-in for future sink. Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Staff Locker Room Second Door Style GO BUILDING Width Area & Volume Height 28-42m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts 24/10/11 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Second is Inner door of privacy vestibule no lock. Special Requirements Windows Exterior Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 Interior 45-50 55 Covering Special Requirements Exterior Glazing Min Area m2 Min Area 2 V-Blinds m H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special reqts CT/QT Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Use elevations reference Drawing # Specialities 184 and 120 Half metal Lockers as per drawings Wood Other Plywood Millwork Concrete/Block Security Benches x 4 per room Other Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Special Reqts Style Width Height Hardware Special reqts Outlets Other water resistant drywall Drywall/painted Primary Door Communications Other Drywall/epoxy Other LAT Vinyl tile LAT SCWD HM/paint Alum Other A B C Other E 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage No 300x2135 Security Intercom x Audio Video Presentation equipment 1100 x 915 x1 2 x 915 x Intercom (phone feature) Data x Public Address Other 860 x1 Voice x Ceiling Mount Floor Connection Wall connection Special Requirements 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Staff Locker Room Number of Occupants Normal Heat producing Equipment GO BUILDING Building 24/10/11 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Room Power Supply Lighting Regular (20 AMP) QTY Computer(Surge Protected) QTY 6 Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Water Supply Type 110 320 Sinks Special/custom Size Incandescent/LED Dimmable Other features General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Heating Air Conditioning Smudging /Smoke Extraction ceramic double x deep Other fixtures 1100 bulk head desk No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) No wall mount L= W= basic goose neck single lever double lever Hands free Shower grease trap spray wand D= wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x1 Mechanical and HVAC Dedicated Thermostat single x Flow Valve other Faucet Set Dimmable ceiling below cupboards DHW In counter General Lighting to have dual levels controlled by switching Task Light Location Exhaust to outside custom size stainless steel sink x 750 750 Large Xerox stainless steel sink Type Fluorescent 540 Small Xerox x DCW Uninterrupted 540 x Printers Temperature Control Valve Lighting Level (lumens) General Computers Total Number of Fixtures to meet Code Minimum regular receptacles is 1 per 3 metres around room QTY 2 30 Other Special Requirements Regular (15 AMP) Maximum 20 Drainage Garbage Can x 2 Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Warehouse Style GO BUILDING Width Area & Volume Height 325m2 Area Requirements Minimum Height or 2400 Special Requirements L= W= 2700 Hardware 3000 other Special reqts Partial open 2 storey with 120 m2 on second floor Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 45-50 55 Windows Special Requirements Covering Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/sealed Carpet Exterior Glazing Special Reqts Walls Special reqts Rubber Carpet Slip Resistant Drywall self Millwork Concrete/Block Special Reqts Ceiling Paint Epoxy Style Width Hardware Special reqts Other H 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe OtherSecond door is loading dock overhead door of 3000*3650 There are also two access points into main building of 915*2135 HM paint Type B, one per level. Exterior Min Area 3.66m2 Interior Min Area V-Blinds Operable m2 H-Blinds Sill Height AFF Curtains Other Security Protection Level exterior windows refer to drawings Use elevations reference Drawing # CT Other Drywall/epoxy Other LAT Vinyl tile LAT Communications Outlets Other SCWD HM/paint Alum Other A B C Other 860 x1 2135 Lock set Passage No 300x2135 Security Intercom (phone feature) Data x TBD Intercom x 1 Audio Video Presentation equipment 1 x 600&1 x 915 x Side Lights Voice x TBD Public Address 1100 x 915 x1 2 x 915 x Height Other Other Open Structure Primary Door C Specialities Drywall/painted Special Reqts Alum B Security Other Finish HM/paint A Wood Other Plywood SCWD CT/QT Other Cove/Base 01/01/12 Ceiling Mount Floor Connection Wall connection 860x1100 Electronic/Swipe OtherThis door is considered man door near front canopy Special Requirements Minimum of 4 voice 4 data. Intercom to exterior loading area . Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Number of Occupants Warehouse Normal Heat producing Equipment GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Minimum regular receptacles is 1 /per1 m at above counter areas Minimum regular receptacles is 1 per 3 metres around room Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 4 QUAD Printer(dedicated) QTY 1 Housekeeping(dedicated) QTY 2 Standard Emergency Plumbing Type 110 320 x4 Small Xerox Printers x1 Large Xerox Fork lift, style and type to be determined. HVAC to suit warehouse environment. Water Supply DCW DHW Temperature Control Valve Sinks stainless steel sink Type single x Flow Valve ceramic double x deep custom size stainless steel sink x In counter Uninterrupted Special/custom Size No wall mount L= W= 540 750 basic goose neck Fluorescent Dimmable single lever double lever Incandescent/LED Dimmable Hands free Shower Faucet Set Other features General lighting to have multiple zones and controls Task 320 Type Fluorescent 540 750 1100 Other fixtures wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x 1 Shower x Dimmable bulk head desk grease trap spray wand Dimmable Incandescent/LED ceiling below cupboards D= other General Lighting to have dual levels controlled by switching Task Light Location Computers Total Number of Fixtures to meet Code Lighting Level (lumens) General 10 Other Special Requirements Room Power Supply Maximum 2 Accessories special Soap Dispenser x Paper Towel Dispenser x Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Staff Shower Room Second Door Style GO BUILDING Width Area & Volume Height 10m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Special Requirements Windows Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 45-50 Covering 55 Exterior Glazing Special Requirements Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special reqts Special Reqts Walls Rubber Carpet Slip Resistant Drywall self m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Toilet enclosure Millwork Use elevations reference Drawing # Specialities Shower curtian and rod Wood Other Plywood Min Area CT/QT Other Cove/Base Exterior Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Primary Door Style Width Height Hardware Special reqts Outlets Other water resistant drywall Drywall/painted Special Reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT HM/paint Alum Other A B C Other E 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security Data x Intercom x Public Address SCWD 2 x 915 x Intercom (phone feature) Audio Video Presentation equipment Other 860 x Voice x Ceiling Mount Floor Connection Wall connection Special Requirements 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 01/01/12 Number of Occupants General Information Room/ Functions Staff Shower Room Heat producing Equipment (list number of devices) GO BUILDING Building Normal Maximum 4 4 Computers x Small Xerox Printers x Large Xerox Other Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Regular (15 AMP) Room Power Supply Lighting QTY 1 GFI at sink Regular (20 AMP) QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Type 110 320 Sinks stainless steel sink Type Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards deep L= W= basic goose neck single lever double lever Hands free Shower grease trap spray wand Other fixtures 1100 bulk head desk No wall mount D= other 750 750 double x single x 1 In counter Fluorescent 540 Flow Valve ceramic custom size stainless steel sink x Uninterrupted 540 DHW Temperature Control Valve Lighting Level (lumens) General Shower room exhaust to outside. Toilet x 1 wing handles extra water quick disconnect Other: Urinal x Hose bibb connect x Shower x 2 Accessories Soap Dispenser x 1 Paper Towel Dispenser x 1 special Soap Dispenser (hands free) x Sink Mirror and shelf x1 Mechanical and HVAC Dedicated Thermostat Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) Drainage Garbage Can x 1 Sanitary Disposal x 1 Towel Bars x Clothes hooks x 2 Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Showers commercial grade acrylic Sanitary Disposal In female only. Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Corridors Style GI or GO BUILDING Width Area & Volume Height m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts Special Requirements Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 Windows 45-50 55 Covering Special Requirements Exterior Glazing Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Insulated weather protected steel , final number of Exit doors as required Exterior Min Area m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Special reqts CT/QT Other Cove/Base 01/01/12 Concrete/Block Security Millwork Use elevations reference Drawing # Specialities Other Finish Special Reqts Ceiling Paint Epoxy CT Drywall/painted Open Structure Special Reqts Primary Door Style Width Height Hardware Special reqts Other Communications Other Drywall/epoxy Other LAT Vinyl tile LAT Outlets Intercom (phone feature) Data x Intercom x Public Address Other SCWD HM/paint Alum Other A B C Other 860 x 915 xTBD 2 x 915 x 1 x 600&1 x 915 x 2135 Voice x Side Lights Lock set Passage No Audio Video Presentation equipment Ceiling Mount Floor Connection Wall connection 1100 x 300x2135 Security Special Requirements 860x1100 Intercoms/phones to be placed outside each suite for controlled access. Electronic/Swipe OtherFinal number and location of corridor doors TBD. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Number of Occupants Corridors Normal Heat producing Equipment GI or GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 0 0 Computers x Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 per 7.5m length Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures 1100 bulk head desk Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) No wall mount L= W= basic goose neck single lever double lever Hands free Shower grease trap spray wand D= wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building GI or GO BUILDING Electrcial, Telecom and LAN Second Door Style Width Area & Volume Height Area Requirements 12.0m2 Minimum Height 2400 Special Requirements or L= W= 2700 Hardware 3000 other Special reqts SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Telecom and LAN functions to be physically separated Windows Noise Attenuation & Vibration Control Room Acoustic Rating Special Requirements 35-40 40-50 45-50 Covering 55 Exterior Glazing Isolate noise to surrounding rooms Structure Floor 01/01/12 Exterior Min Area m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Special reqts Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet CT/QT Millwork Use elevations reference Drawing # Otherstatic resistant Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Specialities Other Plywood Concrete/Block Security OtherPlywood as required by code. Also Secure type wall. Communications Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Primary Door Style Width Height Hardware Special reqts Outlets Other Drywall/painted Special Reqts Other Drywall/epoxy Other LAT Vinyl tile LAT SCWD HM/paint Alum Other A B C Other E 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage No 300x2135 Intercom x Audio Video Presentation equipment Special Requirements 1100 x Security Intercom (phone feature) Data x Public Address Other 860 x Voice x Ceiling Mount Floor Connection Wall connection Secure Cabinet for LAN, divisable for multiple systems Separate Secure Cabinet/Panel for Securiy systems 860x1100 Electronic/Swipe OtherAlarmed Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Electrcial, Telecom and LAN GI or GO BUILDING Building 01/01/12 Number of Occupants Normal Heat producing Equipment (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Minimum regular receptacles is 1 per 3 metres around room Lighting Regular (15 AMP) QTY TBD Regular (20 AMP) QTY TBD Computer(Surge Protected) QTY TBD QTY Housekeeping(dedicated) QTY 1 Emergency Plumbing Type 110 320 Water Supply HVAC to suit loads from all systems DCW Sinks DHW stainless steel sink Type single x Flow Valve ceramic double x In counter Special/custom Size 540 Faucet Set deep No wall mount L= W= basic goose neck Dimmable single lever double lever Dimmable Hands free Shower 750 General Lighting to have dual levels controlled by switching Other features 320 750 Type Fluorescent Dimmable Incandescent/LED Dimmable Other fixtures 1100 bulk head desk grease trap spray wand General lighting to have multiple zones and controls Task ceiling below cupboards Large Xerox D= other Incandescent/LED Task Light Location Small Xerox x Temperature Control Valve Uninterrupted Fluorescent 540 x Printers Total Number of Fixtures to meet Code Lighting Level (lumens) General Computers custom size stainless steel sink x Printer(dedicated) Standard 1 Other Minimum regular receptacles is 1 /per1 m at above counter areas Room Power Supply Maximum 1 wing handles extra water quick disconnect Other: Toilet x 1 Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Janitor Closet Style GI or GO BUILDING Width Area & Volume Height 2.0m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set 1100 x No Passage 300x2135 Security 860x1100 Electronic/Swipe Other Special Requirements Windows Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 45-50 Covering 55 Exterior Glazing Special Requirements Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special Reqts Walls Rubber Carpet Slip Resistant Drywall m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level CT/QT self Millwork Use elevations reference Drawing # Specialities Mop rack wallmount above sink Wood Other Plywood Min Area Special reqts Other Cove/Base Exterior Concrete/Block Security Storage shelving wall mount Other Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Primary Door Style Width Height Hardware Special reqts Outlets Other water resistant drywall Drywall/painted Special Reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT HM/paint Alum A B C 2 x 915 x 1 x 600&1 x 915 x Lock set Passage 1100 x No Intercom x Ceiling Mount Floor Connection Wall connection Other 860 x1 Side Lights Data x Public Address Other 915 x 2135 Intercom (phone feature) Audio Video Presentation equipment Other SCWD Voice x 300x2135 Security Special Requirements 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 01/01/12 Number of Occupants General Information Room/ Functions Janitor closet Heat producing Equipment (list number of devices) GI or GO BUILDING Building Normal Maximum 1 1 Computers x Small Xerox Printers x Large Xerox Other Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Regular (15 AMP) Room Power Supply Lighting QTY QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 Standard Emergency stainless steel sink Type Type 110 320 Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures 1100 bulk head desk Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) No wall mount L= W= D= basic goose neck single lever double lever Hands free Shower grease trap extra water quick disconnect spray wand wing handles Other:Vacuum breaker Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat deep other floor mount mop sink 750 Fluorescent 540 double x In counter Special/custom Size Uninterrupted 540 single x Flow Valve ceramic custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Sinks Regular (20 AMP) Room exhaust to outside. Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Kitchen Style GI BUILDING Width Area & Volume Height Area Requirements 10.0m2 Minimum Height 2400 or L= W= 2700 Hardware 3000 other Special reqts 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Special Requirements Windows Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 45-50 Covering 55 Exterior Glazing Special Requirements Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special Reqts Walls Carpet Slip Resistant Drywall m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level CT/QT Millwork Rubber Min Area Special reqts Other Cove/Base Exterior self Use elevations reference Drawing # 1E Wood Specialities Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Outlets Other Drywall/painted Open Structure Special Reqts Primary Door Style Width Height Hardware Special reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT HM/paint Alum A B C Other 1100 x 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage No 300x2135 Security Data x Intercom x Public Address Other 860 x1 Intercom (phone feature) Audio Video Presentation equipment Other SCWD Voice x 1 Ceiling Mount Floor Connection Wall connection Special Requirements 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 01/01/12 Number of Occupants General Information Room/ Functions Kitchen Heat producing Equipment (list number of devices) GI BUILDING Building Normal Maximum 2 5 Computers x Small Xerox Printers x Large Xerox Other Refrigerator, Microwave Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Refrigerator Regular (20 AMP) QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 Standard Emergency Type 110 320 Sinks stainless steel sink Type Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards Other fixtures 1100 bulk head desk Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) No wall mount L= W= basic goose neck single lever double lever Hands free Shower grease trap spray wand D= Toilet x wing handles extra water quick disconnect Other: Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x 1 Paper Towel Dispenser x 1 special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat deep other 750 750 ceramic double x In counter Fluorescent 540 single x Flow Valve custom size stainless steel sink x Uninterrupted 540 DHW Temperature Control Valve Lighting Level (lumens) General Separated Kitchen exhaust to outside. Drainage Garbage Can x 1 Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building MAIN Vestiuble , Stair Second Door Style GI or GO BUILDING Width Height m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts To suit stair Room Acoustic Rating 35-40 40-50 Windows 45-50 Covering Exterior Glazing Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special reqts CT/QT Other Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Style Width Hardware Special reqts 2135 1 x 600&1 x 915 x Side Lights Lock set Passage No 300x2135 Security 860x2135 Electronic/Swipe Other1 door per level, Access control on both coordinate Millwork Min Area 3.66m2 Min Area V-Blinds m 2 H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Exterior windows to suit stairwell design and views for enhanced dynamic supervision. Use elevations reference Drawing # Specialities Drywall/epoxy Other LAT Vinyl tile LAT Outlets Voice x Intercom (phone feature) Data x Intercom x Other SCWD HM/paint A Audio Video Presentation equipment Other 1100 x 915 x1 Ceiling Mount Floor Connection Wall connection 1 x 600&1 x 915 x Side Lights Lock set Public Address Other C 860 x 2135 Alum B 2 x 915 x Height Other H 1100 x 915 x2 Communications Open Structure Special Reqts 860 x Other Other Other Drywall/painted Primary Door C Interior Structure Special Reqts Alum B Exterior 55 Special Requirements Cove/Base HM/paint A with second access door in cooridor Noise Attenuation & Vibration Control Floor SCWD 2 x 915 x Area & Volume Special Requirements 01/01/12 Passage No 300x2135 Security 860x1100 Electronic/Swipe Special Requirements Intercoms/phones may be placed outside on second level for controlled access. OtherSteel, Insualted and weather protection Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 01/01/12 Number of Occupants General Information Room/ Functions MAIN Vestiuble , Stair Heat producing Equipment (list number of devices) GI or GO BUILDING Building Normal Maximum 0 0 Computers x Small Xerox Printers x Large Xerox Other Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Plumbing Minimum regular receptacles is 1 /per1 m at above counter areas Total Number of Fixtures to meet Code Water Supply DCW Room Power Supply Lighting Sinks QTY QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 per 7.5m length Standard Emergency stainless steel sink Type Regular (20 AMP) Type 110 320 Special/custom Size 750 Dimmable Incandescent/LED Dimmable Other features General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards Heating Air Conditioning Smudging /Smoke Extraction Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Soap Dispenser x Paper Towel Dispenser x Soap Dispenser (hands free) x special Mirror and shelf x Drainage No Preference L= Shower x Accessories Mechanical and HVAC Dedicated Thermostat Other fixtures 1100 bulk head desk No wall mount spray wand General Lighting to have dual levels controlled by switching 750 deep other Faucet Set Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Minimum regular receptacles is 1 per 3 metres around room Regular (15 AMP) Area space heater Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Meeting Room Small Second Door Style GI or GO BUILDING Width Height Area & Volume Hardware 15m2 Area Requirements Minimum Height or 2400 L= W= 2700 Special reqts 3000 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Windows Special Requirements 40-50 Exterior Covering 45-50 55 Exterior Glazing RC 25-30 860x1100 Electronic/Swipe Min Area 2.5m2 Min Area V-Blinds m Operable 2 H-Blinds Sill Height AFF Curtains Other Security Protection Level Special reqts Structure Floor 300x2135 Security Other Interior Noise Attenuation & Vibration Control 35-40 No Passage other Special Requirements Room Acoustic Rating 1100 x Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Millwork CT/QT Use elevations reference Drawing # Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Communications Paint Epoxy CT Open Structure Primary Door Style Width Hardware Special reqts Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x 4 Intercom x Audio Video Presentation equipment SCWD HM/paint Alum Other A B C Other 860 x 2135 Voice x 4 Public Address Other 915 x1 2 x 915 x Height Outlets Other Other Drywall/painted Special Reqts Specialities Special Requirements 1100 x 1 x 600&1 x 915 x Side Lights Lock set Ceiling Mount Floor Connection Wall connection Passage No 300x2135 Security 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Meeting Room Small Number of Occupants Normal Heat producing Equipment GI or GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 5 8 Computers x4 Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 2 QUAD Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) L= W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Multi Purpose Room (1) Second Door Style GI BUILDING Width Height Area & Volume Hardware 60m2 Area Requirements Minimum Height or 2400 Special Requirements L= W= 2700 Special reqts 3000 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Special Requirements 40-50 Windows Exterior Covering 45-50 55 Exterior Glazing RC 25-35 860x1100 Electronic/Swipe Min Area 5.26m2 Min Area V-Blinds m 2 H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Special reqts Structure Floor 300x2135 Security Other Interior Noise Attenuation & Vibration Control 35-40 No other CAPABLE TO ADAPT TO MULTIPLE TRAINING FORMATS Room Acoustic Rating Passage 1100 x Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Millwork CT/QT Use elevations reference Drawing # Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Communications Paint Epoxy CT Open Structure Primary Door Style Width Height Hardware Special reqts Outlets Other Other Drywall/painted Special Reqts Specialities Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x 8 Intercom x Public Address Audio Video Presentation equipment Other SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x1 1 x 600&1 x 915 x 2135 Voice x 8 Side Lights Lock set Passage Special Requirements 1100 x No 300x2135 Security Ceiling Mount Floor Connection Wall connection Certain data drops may be set for inmate system only. Outlets may left non functional based on final room occupancy. 860x2135 Electronic/Swipe OtherSidelights on both sides of double doors Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Multi Purpose Room (1) Number of Occupants Normal Heat producing Equipment GI BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 12 50 Computers x8 Small Xerox Printers x1 Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Type QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 4 QUAD custom size stainless steel sink x Printer(dedicated) QTY 1 In counter Housekeeping(dedicated) QTY 1 Standard Emergency Sinks stainless steel sink Type Special/custom Size Uninterrupted 110 320 Faucet Set 540 750 Fluorescent Dimmable Incandescent/LED Dimmable Other features General lighting to have multiple zones and controls Task 320 540 Type Fluorescent Dimmable Incandescent/LED Dimmable ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Accessories Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) wall mount L= W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Soap Dispenser x Paper Towel Dispenser x special Preferred Required deep Shower x Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No ceramic double x spray wand 1100 bulk head desk single x other General Lighting to have dual levels controlled by switching Task Light Location Flow Valve Regular (15 AMP) Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building GI BUILDING MULTI PURPOSE ROOM (2) Second Door Style Width Height Hardware Area & Volume 40-45m2 Area Requirements Minimum Height or 2400 Special Requirements L= Special reqts W= 2700 3000 other Windows Room Acoustic Rating Special Requirements 35-40 40-50 Exterior Glazing 55 HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Interior Covering 45-50 SCWD Exterior CAPABLE TO ADAPT TO MULTIPLE TRAINING FORMATS Noise Attenuation & Vibration Control 01/01/12 Min Area 2.88m2 Min Area 1.44m V-Blinds 2 H-Blinds Operable Sill Height AFF 1100 Curtains Other Security Protection Level RC 25-35 Special reqts Interior windows to corridor for dynamic supervision Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall Millwork Use elevations reference Drawing # Specialities Large white boards x 3 CT/QT self Wood Other Plywood Concrete/Block Security Communications Other Outlets Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Special Reqts Style Width Height Hardware Special reqts Voice x 8 Intercom (phone feature) Data x 8 Intercom x Other Drywall/painted Primary Door Other Drywall/epoxy Other LAT Vinyl tile LAT Public Address Audio Video Presentation equipment Other SCWD HM/paint Alum Other A B C Other 860 x 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage No Special Requirements 1100 x 300x2135 Security Ceiling Mount Floor Connection Wall connection Certain data drops may be set for inmate system only. Outlets may left non-functional based on final room occupancy. 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions MULTI PURPOSE ROOM (2) GI BUILDING Building 01/01/12 Number of Occupants Normal Heat producing Equipment (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 12 25 Computers x8 Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 4 QUAD Printer(dedicated) QTY 1 Housekeeping(dedicated) QTY 1 Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Accessories Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Soap Dispenser x Paper Towel Dispenser x special Preferred Required L= Shower x Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Office (1) Style GI or GO BUILDING Width Height Area & Volume Area Requirements 11.0m2 Minimum Height 2400 Hardware or L= W= 2700 Special reqts 3000 Windows Special Requirements 40-50 Alum B C Other Other E 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set 1100 x No Passage 300x2135 Security 860x1100 Electronic/Swipe Other Exterior Covering 45-50 55 Exterior Glazing RC 25-35 Min Area 2.5m2 Min Area V-Blinds m Operable 2 H-Blinds Sill Height AFF Curtains Other Security Protection Level Special reqts Structure Floor HM/paint A Interior Noise Attenuation & Vibration Control 35-40 SCWD other Special Requirements Room Acoustic Rating 01/01/12 Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Millwork CT/QT Use elevations reference Drawing # Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Communications Paint Epoxy CT Open Structure Primary Door Style Width Hardware Special reqts Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x 4 Intercom x Audio Video Presentation equipment SCWD HM/paint Alum Other A B C Other 860 x 2135 Voice x 4 Public Address Other 915 x1 2 x 915 x Height Outlets Other Other Drywall/painted Special Reqts Specialities Special Requirements 1100 x 1 x 600&1 x 915 x Side Lights Lock set Ceiling Mount Floor Connection Wall connection Passage No 300x2135 Security 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Number of Occupants Office (1) Normal Heat producing Equipment GI or GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 1 4 Computers x4 Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 2 QUAD Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) L= W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Office (2) Style GI or GO BUILDING Width Height Area & Volume Hardware Area Requirements 15.0m2 Minimum Height 2400 or L= W= 2700 Special reqts 3000 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Windows Special Requirements 40-50 Exterior Covering 45-50 55 Exterior Glazing RC 25-35 860x1100 Electronic/Swipe Min Area 2.5m2 Min Area V-Blinds m Operable 2 H-Blinds Sill Height AFF Curtains Other Security Protection Level Special reqts Structure Floor 300x2135 Security Other Interior Noise Attenuation & Vibration Control 35-40 No Passage other Special Requirements Room Acoustic Rating 1100 x Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Millwork CT/QT Use elevations reference Drawing # Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Communications Paint Epoxy CT Open Structure Primary Door Style Width Hardware Special reqts Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x 4 Intercom x Audio Video Presentation equipment SCWD HM/paint Alum Other A B C Other 860 x 2135 Voice x 4 Public Address Other 915 x1 2 x 915 x Height Outlets Other Other Drywall/painted Special Reqts Specialities Special Requirements 1100 x 1 x 600&1 x 915 x Side Lights Lock set Ceiling Mount Floor Connection Wall connection Passage No 300x2135 Security 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Number of Occupants Office (2) Normal Heat producing Equipment GI or GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 2 6 Computers x4 Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 2 QUAD Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) L= W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Open Workstations Second Door Style GI or GO BUILDING Width Height Area & Volume Hardware 25-180m2 Area Requirements Minimum Height or 2400 Special Requirements L= W= 2700 Special reqts 3000 Special Requirements 40-50 Windows 45-50 Exterior Glazing 55 Special Reqts Sheet vinyl seamless Concrete/painted Carpet Millwork 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Carpet Slip Resistant self Style Width Height Hardware Special reqts 300x2135 Security 860x1100 Electronic/Swipe V-Blinds Min Area TBDm2 Min Area m Operable 2 H-Blinds Sill Height AFF Curtains Other Security Protection Level Exterior windows to suit building and layout of the open area Use elevations reference Drawing # 1D Wood Concrete/Block Security Communications Paint Voice x TBD Intercom (phone feature) Other Data x TBD Intercom x Drywall/epoxy Other Public Address LAT Vinyl tile LAT Epoxy CT Other Open Structure Primary Door No Other Plywood Drywall/painted Special Reqts Passage Other Outlets Special Reqts Side Lights Lock set 1100 x CT/QT Other Ceiling Other E 860 x Specialities Rubber Drywall Finish Other Refer to drawings for minimums Vinyl Tile Other Walls C RC 25-35 Structure Cove/Base Alum B Interior Special reqts Floor HM/paint A Exterior Covering Noise Attenuation & Vibration Control 35-40 SCWD other Planning of approximately 1workstation /10m2gross area with each station set at 5.9m2 Room Acoustic Rating 01/01/12 Audio Video Presentation equipment Other SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage Special Requirements 1100 x No 300x2135 Security 860x1100 Ceiling Mount Floor Connection Wall connection Minumum 2 Voice 2 Data per Workstaion as per drawing 1 Data for printers per 10 workstations Minimum 2 Voice and 2 Data at copy and print alcove above counter 1 Data for copier Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 01/01/12 Number of Occupants General Information Room/ Functions Open Workstations Heat producing Equipment (list number of devices) GI or GO BUILDING Building Normal Maximum 2 20 Computers x TBD Small Xerox Printers x TBD Large Xerox Other Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Minimum regular receptacles is 1 per 3 metres around room Plumbing Regular (15 AMP) QTY Water Supply Regular (20 AMP) QTY Computer(Surge Protected) QTY TBD, 4 per station Printer(dedicated) QTY 1 per 10 staff Housekeeping(dedicated) Room Power Supply Lighting Standard Type 110 320 DCW Sinks stainless steel sink Type Faucet Set Dimmable Dimmable General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task Type Task Light Location 320 540 750 Dimmable Incandescent/LED Dimmable ceiling below cupboards Other features bulk head desk No wall mount L= W= D= basic goose neck single lever double lever Hands free Shower grease trap extra water quick disconnect spray wand 1100 Fluorescent deep other 750 Incandescent/LED double x In counter Special/custom Size Fluorescent single x Flow Valve ceramic custom size stainless steel sink x Uninterrupted 540 DHW Temperature Control Valve Lighting Level (lumens) General Total Number of Fixtures to meet Code QTY 1/20m2 Emergency Final numbers to suit final layout of workstations. Central printer and copy areas to be set up in key locations. Must include 50% spare capacity for Voice ,Data and electrical outlets. Other fixtures wing handles Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories special Soap Dispenser x Paper Towel Dispenser x Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building PROGRAM ROOM (1) Style GI BUILDING Width Height Area & Volume Hardware 48 m2 Area Requirements Minimum Height or 2400 Special Requirements L= W= 2700 Special reqts 3000 CAPABLE TO ADAPT TO MULTIPLE TRAINING FORMATS Room Acoustic Rating Special Requirements 35-40 40-50 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other other Windows Exterior Interior Noise Attenuation & Vibration Control Covering 45-50 55 Exterior Glazing RC 25-35 Structure Floor Second Door 01/01/12 Special reqts Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet CT/QT Min Area 2.88m2 Min Area 1.44m V-Blinds 2 H-Blinds Operable Sill Height AFF 1100 Curtains Other Security Protection Level Interior windows to corridor for dynamic supervision Millwork Use elevations reference Drawing # Specialities Large white boards x 3 Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Wood Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Communications Paint Epoxy CT Other Drywall/painted Open Structure Special Reqts Primary Door Style Width Hardware Special reqts Drywall/epoxy Other LAT Vinyl tile LAT SCWD HM/paint Alum A B C 860 x 2135 Lock set Passage Intercom x Ceiling Mount Floor Connection Wall connection Other Special Requirements 1100 x 1 x 600&1 x 915 x No Intercom (phone feature) Data x 8 Public Address Other 915 x1 Side Lights Voice x 8 Audio Video Presentation equipment Other 2 x 915 x Height Outlets Other 300x2135 Security Certain data drops may be set for inmate system only. Outlets may left non-functional based on final room occupancy. 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada PROGRAM ROOM (1) Room/ Functions Number of Occupants Normal Heat producing Equipment GI BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 12 25 Computers x8 Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 4 QUAD Printer(dedicated) QTY 1 Housekeeping(dedicated) QTY 1 Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Accessories Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Soap Dispenser x Paper Towel Dispenser x special Preferred Required L= Shower x Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Program room (2) Second Door Style GI BUILDING Width Height Area & Volume Hardware 25-35m2 Area Requirements Minimum Height or 2400 Special Requirements L= W= 2700 Special reqts 3000 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Special Requirements 40-50 Windows Exterior Covering 45-50 55 Exterior Glazing RC 25-35 Special reqts Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Millwork CT/QT Cove/Base Walls Rubber Carpet Slip Resistant Drywall Special Reqts Ceiling self Plywood Wood Concrete/Block Epoxy Style Width Hardware Special reqts Other Use elevations reference Drawing # Specialities Large white boards x 2 only 1 in the smaller rooms Security CT Outlets Other Drywall/epoxy Other LAT Vinyl tile LAT HM/paint Alum Other A B C Other 860 x 915 x1 Lock set Passage No Special Requirements 1100 x 300x2135 Security Intercom (phone feature) Data x 6 Intercom x Audio Video Presentation equipment 1 x 600&1 x 915 x Side Lights Voice x 6 Public Address SCWD 2135 Sill Height AFF 1100 Curtains Interior windows to corridor for dynamic supervision Other 2 x 915 x Height H-Blinds Security Protection Level Other Open Structure Primary Door Min Area 1.44m V-Blinds Operable 2 Communications Paint Drywall/painted Special Reqts Min Area 2.88m2 Other Other Finish 860x1100 Electronic/Swipe DWG 1A, Lockbable storage units Other Special Reqts 300x2135 Security Other Interior Noise Attenuation & Vibration Control 35-40 No other CAPABLE TO ADAPT TO MULTIPLE TRAINING FORMATS Room Acoustic Rating Passage 1100 x Ceiling Mount Floor Connection Wall connection Certain data drops may be set for inmate system only. Outlets may left non functional based on final room occupancy. 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Program Room 2 Number of Occupants Normal Heat producing Equipment GI BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 10 16 Computers x6 Small Xerox Printers x1 Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 3 QUAD Printer(dedicated) QTY 1 Housekeeping(dedicated) QTY 1 Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) L= W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building SECONDARY Stair Second Door Style GI or GO BUILDING Width Area & Volume Height m2 Area Requirements Minimum Height or 2400 Special Requirements L= W= 2700 Hardware 3000 other Special reqts 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x2 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x2135 Electronic/Swipe Other1 door AT TOP OF STAIR To suit stair Windows Exterior Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 Interior 45-50 55 Covering Special Requirements Exterior Glazing Min Area m2 Min Area 2 V-Blinds m H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special reqts CT/QT Millwork Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Use elevations reference Drawing # Wood Specialities Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Outlets Other Drywall/painted Open Structure Special Reqts Primary Door Style Width Height Hardware Special reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT HM/paint Alum A B C Other D 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage No 1100 x 300x2135 Security Data x Intercom x Public Address Other 860 x Intercom (phone feature) Audio Video Presentation equipment Other SCWD Voice x Ceiling Mount Floor Connection Wall connection Special Requirements 860x1100 Electronic/Swipe OtherSteel, Insulated and weather protection Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions SECONDARY Stair Number of Occupants Normal Heat producing Equipment GI or GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 per 7.5m length Emergency Water Supply Type 110 320 Sinks Special/custom Size Incandescent/LED Dimmable Other features General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Heating Air Conditioning Smudging /Smoke Extraction ceramic double x deep Other fixtures 1100 bulk head desk No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) No wall mount L= W= basic goose neck single lever double lever Hands free Shower grease trap spray wand D= wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat single x Flow Valve other Faucet Set Dimmable ceiling below cupboards DHW In counter General Lighting to have dual levels controlled by switching Task Light Location Area space heater custom size stainless steel sink x 750 750 Large Xerox stainless steel sink Type Fluorescent 540 Small Xerox x DCW Uninterrupted 540 x Printers Temperature Control Valve Lighting Level (lumens) General Computers Total Number of Fixtures to meet Code Minimum regular receptacles is 1 per 3 metres around room Standard 0 Other Special Requirements Room Power Supply Maximum 0 Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Storage and Support Second Door Style GI or GO BUILDING Width Area & Volume Height 10-25m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Special Requirements Windows Exterior Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 Interior 45-50 55 Covering Special Requirements Exterior Glazing Min Area 1.44m2 Min Area V-Blinds m 2 H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special reqts CT/QT Millwork Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall When locatedon exterior walls , include exterior windows self Use elevations reference Drawing # Wood Specialities Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Outlets Other Drywall/painted Open Structure Special Reqts Primary Door Style Width Height Hardware Special reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x 4 Intercom x Public Address Other SCWD HM/paint Alum A B C Other 1100 x 915 x1 2 x 915 x 1 x 600&1 x 915 x Side Lights Lock set Passage No Audio Video Presentation equipment Other 860 x1 2135 Voice x 4 300x2135 Security Special Requirements Ceiling Mount Floor Connection Wall connection Rooms that are 10m2 or smaller will only require 2 voice and 2 data 860x1100 Electronic/Swipe Other Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Storage and Support Number of Occupants Normal Heat producing Equipment GI or GO BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Maximum 2 2 Computers x2 Small Xerox Printers x Large Xerox Other Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting Regular (15 AMP) QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY 2 QUAD Printer(dedicated) QTY Housekeeping(dedicated) QTY 1 Standard Emergency Sinks stainless steel sink Type Type 110 320 Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards 750 Other fixtures Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) L= W= D= basic goose neck single lever double lever Hands free Shower grease trap wing handles extra water quick disconnect Other: Toilet x Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x Paper Towel Dispenser x special Soap Dispenser (hands free) x Mirror and shelf x Mechanical and HVAC Dedicated Thermostat No wall mount spray wand 1100 bulk head desk deep other 750 Fluorescent 540 ceramic double x In counter Uninterrupted 540 single x Flow Valve custom size stainless steel sink x Lighting Level (lumens) General DHW Temperature Control Valve Drainage Garbage Can x Sanitary Disposal x Towel Bars x Clothes hooks x Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Washroom 1 Style GI or GO BUILDING Width Area & Volume Height 3.5-5.0m2 Area Requirements Minimum Height or 2400 L= W= 2700 Hardware 3000 other Special reqts 01/01/12 SCWD HM/paint Alum Other A B C Other 860 x 915 x 2 x 915 x 1 x 600&1 x 915 x 2135 Side Lights Lock set Passage 1100 x No 300x2135 Security 860x1100 Electronic/Swipe Other Special Requirements Windows Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 45-50 55 Covering Special Requirements Exterior Glazing Exterior Min Area m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special reqts CT/QT Millwork Other Cove/Base Special Reqts Walls Rubber Carpet Slip Resistant Drywall self Use elevations reference Drawing # Wood Specialities Other Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Primary Door Style Width Height Hardware Special reqts Outlets Other water resistant drywall Drywall/painted Special Reqts Communications Other Drywall/epoxy Other LAT Vinyl tile LAT HM/paint Alum A B C 2 x 915 x 1 x 600&1 x 915 x Side Lights Passage No Ceiling Mount Floor Connection Wall connection Other E 915 x1 Lock set Intercom x Audio Video Presentation equipment Other 860 x 2135 Intercom (phone feature) Data x Public Address Other SCWD Voice x 1100 x 300x2135 Security Special Requirements 860x1100 Electronic/Swipe OtherStaff washrooms to include keyless lockset Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET Correctional Service Canada 01/01/12 Number of Occupants General Information Room/ Functions Washroom 1 Heat producing Equipment (list number of devices) GI or GO BUILDING Building Normal Maximum 1 1 Computers x Small Xerox Printers x Large Xerox Other Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Special Requirements Minimum regular receptacles is 1 /per1 m at above counter areas Plumbing Total Number of Fixtures to meet Code Water Supply DCW Minimum regular receptacles is 1 per 3 metres around room Regular (15 AMP) Room Power Supply Lighting QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Type 110 320 Sinks stainless steel sink Type Special/custom Size Faucet Set Dimmable Incandescent/LED Dimmable Other features General Lighting to have dual levels controlled by switching General lighting to have multiple zones and controls Task 320 Type Fluorescent Dimmable Incandescent/LED Dimmable Task Light Location ceiling below cupboards deep L= W= basic goose neck single lever double lever Hands free Shower grease trap spray wand Other fixtures 1100 bulk head desk No wall mount D= other 750 750 double x single x 1 custom size stainless steel sink x Fluorescent 540 Flow Valve ceramic In counter Uninterrupted 540 DHW Temperature Control Valve Lighting Level (lumens) General Washroom exhaust to outside Toilet x 1 wing handles extra water quick disconnect Other: Urinal x Hose bibb connect x Shower x Accessories Soap Dispenser x 1 Paper Towel Dispenser x 1 special Soap Dispenser (hands free) x Mirror and shelf x1 Mechanical and HVAC Dedicated Thermostat Heating Air Conditioning Smudging /Smoke Extraction No Preference Required Preferred Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) Drainage Garbage Can x 1 Sanitary Disposal x 1 Towel Bars x Clothes hooks x 1 Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Sanitary Disposal in female designated only. Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2 ROOM DATA SHEET Correctional Service Canada Room/ Functions General Information Building Second Door Washroom 2 Style GI BUILDING Width Height 10m2 Area Requirements or 2400 L= W= 2700 Hardware 3000 other Special reqts Special Requirements Noise Attenuation & Vibration Control Room Acoustic Rating 35-40 40-50 Windows 45-50 55 Covering Special Requirements Exterior Glazing Structure Floor Vinyl Tile Sheet vinyl seamless Concrete/painted Carpet Special Reqts Walls HM/paint Alum A B C 860 x Carpet Slip Resistant Drywall Other E 1100 x 915 x1 2135 1 x 600&1 x 915 x Side Lights Lock set Passage No 300x2135 Security 860x1100 Electronic/Swipe Other Second door is for BF toilet area this can be developed with typical washroom partitions Exterior Min Area m2 Interior Min Area m2 V-Blinds H-Blinds Operable Sill Height AFF Curtains Other Security Protection Level Special reqts Millwork Rubber Other CT/QT Other Cove/Base SCWD 2 x 915 x Area & Volume Minimum Height 01/01/12 self Use elevations reference Drawing # Wood Other Specialities Plywood Concrete/Block Security Other Finish Special Reqts Ceiling Paint Epoxy CT Open Structure Primary Door Style Width Height Hardware Special reqts Communications Other water resistant drywall Drywall/painted Special Reqts Other Outlets Drywall/epoxy Other LAT Vinyl tile LAT Intercom (phone feature) Data x Intercom x Public Address Other SCWD HM/paint Alum Other A B C Other E 860 x 915 x1 2 x 915 x 1 x 600&1 x 915 x 2135 Voice x Side Lights Lock set Passage No Audio Video Presentation equipment Ceiling Mount Floor Connection Wall connection 1100 x Special Requirements 300x2135 Security 860x1100 Electronic/Swipe OtherStaff washrooms to include keyless lockset. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 1 of 2 ROOM DATA SHEET General Information Correctional Service Canada Room/ Functions Number of Occupants Washroom 2 Normal Heat producing Equipment GI BUILDING Building 01/01/12 (list number of devices) Electrical Total Number of elements to meet Code General Power 120V Receptacles(duplex) Minimum regular receptacles is 1 /per1 m at above counter areas Minimum regular receptacles is 1 per 3 metres around room Room Power Supply Lighting QTY Regular (20 AMP) QTY Computer(Surge Protected) QTY Printer(dedicated) QTY Housekeeping(dedicated) QTY Standard Emergency Plumbing Type 110 320 x Small Xerox Printers x Large Xerox Washroom exhaust to outside Water Supply DCW DHW Temperature Control Valve Sinks stainless steel sink Type Flow Valve ceramic double x single x 2 deep custom size stainless steel sink x In counter Uninterrupted Special/custom Size No wall mount L= W= 540 750 basic goose neck Fluorescent Dimmable single lever double lever Incandescent/LED Dimmable Hands free Shower Faucet Set Other features General lighting to have multiple zones and controls Task 320 Type Fluorescent 540 750 1100 Other fixtures Toilet x 1 wing handles extra water quick disconnect Other: Urinal x 2 Hose bibb connect x Shower x Dimmable bulk head desk grease trap spray wand Dimmable Incandescent/LED ceiling below cupboards D= other General Lighting to have dual levels controlled by switching Task Light Location Computers Total Number of Fixtures to meet Code Lighting Level (lumens) General 4 Other Special Requirements Regular (15 AMP) Maximum 4 Accessories special Soap Dispenser x 2 Paper Towel Dispenser x 2 Soap Dispenser (hands free) x Mirror and shelf x2 Mechanical and HVAC Dedicated Thermostat Heating Air Conditioning Smudging /Smoke Extraction No Preference Preferred Required Other (list) 21-23°C (normal) Other (list) Required Not Required Other (list) Required, dedicated to this room. Controls within room with time limit setting and isolation from building HVAC systems. Drainage Garbage Can x 2 Sanitary Disposal x 2 Towel Bars x Clothes hooks x 2 Floor Drain Funnel Floor Drain Special drain for specific equipment Special Requirements Variation on this washroom is to replace 2 urinals with on toilet stall. Note: All Above listed details are minimum CSC functional requirements. The final design and quantities of elements/fixtures must meet all applicable codes and standards. 2 of 2