Transcript
ROOM MANAGER Phoenix Controls Room Manager software is used to centrally manage your Room Integrator and Room Controller integration devices. Features include a job manager commissioning tool to manage new devices, and centralized backup/restore functions. It is also a solution for sites requiring minimal number of IP connections from their room networks to the building automation network. Once installed, Room Manager aggregates points from the room level integration devices and makes them available to third party building management systems. The Room Manager can be easily upgraded to a Phoenix Controls Supervisor to provide a complete airflow control system solution that includes front-end graphics, data trending, airflow analytics, and alarm management. Workbench Diagnostic View
FEATURES • Provides a single connection from the building automation network to the laboratory/room network. • Isolates laboratory/room control network from the building automation network. • RMI/RMC smart import for quick job startup. • Integrates with BACnet IP or BACnet Ethernet. • Secure access point for remote access to integration devices and room-level devices. • Commissioning tools for new Room Integrators/Controllers. • Centralized backup\restore for all connected devices. • Online/Offline configuration via the Phoenix Controls Workbench. • Diagnostic displays for troubleshooting integration hardware, LON® and BACnet® room networks and room devices. • Includes Test and Balance functions for third party agent air flow validation. • Includes Lab Verification functions for start up validation. • Configuration tool for SSL settings, when implemented. • Certificate management of X.509 certificates when deployed in a public key infrastructure (PKI).
75 Discovery Way
•
Acton, MA 01720
•
Tel (978) 795-1285
©2015 Phoenix Controls. Specifications subject to change without notice. Rev. 06/15
Test and Balance Tool, Adjust Flow Screen
TABLE OF CONTENTS Ordering Guide......................................... 2 System Requirements ................................ 2 Applications .............................................. 3 Spare Parts................................................. 4
•
Fax (978) 795-1111
MKT-0373 MPC-2174
•
www.phoenixcontrols.com
ORDERING GUIDE RMM
100
Supervisor Upgrade Information
PRODUCT FAMILY RMM = Room Manager
SUU 100 - BAS -
-
PRODUCT FAMILY SUU = Supervisor Upgrade
SERIES 100 = Series 100
SERIES 100 = Software first generation
SOFTWARE PACKAGE BAS = Base dashboard package BACnet Points For ordering BACnet points, see Part Designation/Number of Points table below OPTIONAL DRIVER 1 = SQL database Note: The Optional Driver is only needed when the SQL database for archiving is on a different PC from the one running Supervisor software.
PART DESIGNATIONS FOR ORDERING ADDITONAL BACNET POINTS Part Designation 01000 01500 02000 02500 03000 03500 04000 04500 05000 05500 06000 06500
Number of Points 1,000 1,500 2,000 2,500 3,000 3,500 4,000 4,500 5,000 5,500 6,000 6,500
Part Designation 07000 07500 08000 08500 09000 09500 10000 10500 11000 11500 12000
Number of Points 7,000 7,500 8,000 8,500 9,000 9,500 10,000 10,500 11,000 11,500 12,000
SYSTEM REQUIREMENTS Processor Intel Pentium™ IV, 2 GHz or higher; Core 2 Duo also acceptable Operating System • Microsoft® Windows® 2008 Server (if Microsoft IIS is disabled) • Microsoft® Windows® 7 Professional, 32- or 64-bit • Microsoft® Windows® 7 Enterprise, 32- or 64-bit • Microsoft® Windows® 8 • Microsoft® Windows® Server 2012 Virtual Machine • VMware® ESX:5.1.0 • Hyper V (Windows 2008 R2 or Windows 2012) Web Browsers • Microsoft® Internet Explorer® 9 or later • Google Chrome 24 or later • Mozilla Firefox® 18 or later • Apple Safari 5 or later Hard Drive • 1 GB minimum • 5 GB for applications that need more archiving capacity Memory • 1 GB minimum • 2 GB or more recommended for large systems Communications Full-time high-speed ISP connection recommended for remote site access (i.e. T1, ADSL, cable modem) Network Support • Two Ethernet adapters (10/100 Mb with RJ-45 connector) • Ethernet driver support for BACnet I/P Display Video card and monitor capable of displaying 1024 x 768 pixel resolution or greater
2 OF 4 ROOM MANAGER
MKT-0373
MPC-2174 ©2015 Phoenix Controls. Specifications subject to change without notice. Rev. 06/15
APPLICATIONS Single IP Connection to Building Automation Network - BACnet® Over IP/Ethernet
BACnet® MS/TP Building Automation Network
©2015 Phoenix Controls. Specifications subject to change without notice. Rev. 06/15 MKT-0373 MPC-2174
ROOM MANAGER 3 OF 4
SPARE PARTS Part Number
Part Description
DRV-I-DR-S-BAC-500
Additional BACnet IP points in increments of 500 (SUU Only)
DRV-I-S-DB-SQL
MicroSoft SQL database driver (SUU Only)
4 OF 4 ROOM MANAGER
MKT-0373