Transcript
Contents
http://catalog.moeller.net
7/1
Rotary switches T, switch-disconnectors P, Small enclosures CI-K
Rotary switches, switch-disconnectors
Mini rotary switches
Small enclosures, empty enclosures
ATEX Page
The powerful, rugged and compact cam switches and switch-disconnectors are used in industry, workshops and in building services management. The basic switch types of four different construction types and with a wide range of standard contact sequences and rating ranges are available.
7/2
Technical overview
7/2
System overview
7/60
System overview
7/4
Description
7/9
Ordering
7/61
Rotary switches
7/4
7/9
Basic enclosures
7/61
Switch-disconnectors
7/6
System overview
7/52
Accessories
7/64
7/8
Ordering
Key to part numbers, modular system Ordering
- up to 10/132 kW - Non-standard circuits possible (EK) - Various types of construction Page 7/52
7/54
Technical data
7/75
Control circuit isolator, ON/OFF switch
7/54
Dimensions
7/88
7/9
Changeover switch, hand/automatic switch
7/55
Load current switches, main switches, maintenance/repair switches
7/10
Load current switches, ON/OFF switches
7/21
Load current switches, changeover contacts
7/25
Load-current switch - Safety switch
7/30
Technical data
7/74
Load current switch - reversing switch
7/32
Dimensions
7/88
Load current switches, (reversing) star-delta switches
7/33
load-current switch - pole-change switch
7/34
Control switch, step switch
7/35
Control switch: ON/OFF switch, changeover, hand/auto switch
7/37 7/38 7/40
- TT rotary switches - P1 and P3 switch-disconnectors - Degree of protection IP65
Control switch - instrument selector switches
7/40
Switch with locking mechanism
7/41
Page 7/4
Main switch assembly kits, thumbgrip, maintenance key
7/43
Front plates
7/44
Add-on front plates
7/45
key operation, locking interlock
7/46
Neutral conductor, auxiliary contact, central mounting accessories, service distribution board mounting accessories
7/48
Coupling drive, interlock parts, shaft extension
7/49
Shrouds, keys
7/50
Insulated enclosures, accessories
7/51
Technical data
- Up to 110 kW and 315 A - P1 and P3 in IP65 enclosure - 4 different types of construction Page 7/6
CI-K enclosure system -
Switch protection in IP65 Individual laser inscription Customized cutouts Cable entry as push-through diaphragm or - knockout Page 7/60
7/67
Switch-disconnectors
7/67
Switch-disconnectors, auxiliary contacts
7/69
Rotary switches
7/70
Dimensions
Control switch, step switch
7/56
Control switch - group switch, ON (OFF) button, reversing switch, coding switch
7/58
Locks, front plates
Control switch - ON buttons, universal control switches
P switch-disconnectors
Key to part numbers, modular system
7/8
Control switch - hand/auto switch
Switch for ATEX Zone 22
Page
Technical overview
Description
TM/T rotary switches
Page
7/76
7/59
Rotary switches T, switch-disconnectors P, Small enclosures CI-K, empty enclosures CI
Moeller HPL0211-2007/2008
Technical overview (Mini) Rotary switch, switch-disconnector T, P, TM Switch, basic type Max. rated operatioal power AC-23 A, 400/415 V, 50/60 Hz Max. rated operational current Iu
Technical overview (Mini) Rotary switch, switch-disconnector Moeller HPL0211-2007/2008
Part no.
http://catalog.moeller.net
http://catalog.moeller.net
7/3
T, P, TM
Moeller HPL0211-2007/2008
TM 3.0 kW
T0 6.5 kW
T3 13 kW
T5(B) 22 kW
T5 30 kW
T6 55 kW
T8 132 kW
P1-25 13 kW
P1-32 15 kW
P3-63 37 kW
P3-100 50 kW
P5-125 45 kW
P5-160 55 kW
P5-250 90 kW
P5-315 110 kW
10 A
20 A
32 A
63 A
100 A
160 A
315 A
25 A
32 A
63 A
100 A
125 A
160 A
250 A
315 A
–
a 7/10
a 7/10
a 7/10
a 7/12
a 7/15
a 7/15
a 7/10
a 7/10
a 7/10
a 7/11
a 7/11
a 7/11
a 7/11
a 7/12
a 7/54 – – – – – – –
a 7/21 – a 7/25 a 7/32 a 7/33 a 7/33 a 7/34 a 7/33
a 7/21 – a 7/25 a 7/32 a 7/33 a 7/33 a 7/34 a 7/33
a 7/21 a 7/30 a 7/26 a 7/32 a 7/33 a 7/33 a 7/34 a 7/33
a 7/24 a 7/30 a 7/26 – – – – –
– – a 7/26 – – – – –
– – a 7/26 – – – – –
a 7/21 a 7/30 – – – – – –
a 7/22 a 7/30 – – – – – –
a 7/22 a 7/30 – – – – – –
a 7/22 a 7/30 – – – – – –
a 7/22 – – – – – – –
a 7/22 – – – – – – –
a 7/22 – – – – – – –
a 7/22 – – – – – – –
Control switches Step switches On-Off switches Changeover switches Hand/Auto switches Spring-return switches Universal control switch Coding switches Series switches Instrument selector switches Group switches On-Off switches, spring-return Reversing switches
a 7/56 – a 7/55 a 7/55 – – a 7/58 – – a 7/58 a 7/58 a 7/58
a 7/35 a 3/37 a 3/37 a 3/37 a 7/39 a 7/39 a 7/40 a 7/40 a 7/40 – – –
– – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
– – – – – – – – – – – –
Switches with interlocks Panic switchs without Emergency-Stop function On-Off switches without Emergency-Stop function
– –
a 7/41 a 7/42
– –
– –
– –
– –
– –
a 7/41 a 7/42
a 7/41 a 7/41
– –
– –
– –
– –
– –
– –
Non-standard switches
a Electronic catalogue, http://catalog.moeller.net
Load current switches Main switch, maintenance/manual override switch On-Off switches Safety switches with warning label Changeover switches Reversing switches with 0 (Off) position Star-delta switches Reversing star-delta switches Multi-speed switches Reversing multi-speed switches
Mounting form Surface mounting
…/I… ATEX
Surface mounting main switch
…/I…/SVB… ATEX
a Electronic catalogue, http://catalog.moeller.net
– –
✔ ✔
✔ ✔
✔ ✔
✔ ✔
– –
– –
✔ ✔
✔ ✔
✔ ✔
✔ ✔
– –
– –
– –
– –
– –
✔ ✔
✔ ✔
✔ ✔
✔ ✔
✔ –
✔ –
✔ ✔
✔ ✔
✔ ✔
✔ ✔
– –
– –
– –
– –
Flush mounting
.../E…
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Flush mounting main switches
…/E(A)/SVB…
✔
✔
✔
✔
✔
–
–
✔
✔
✔
✔
✔
✔
✔
✔
Centre mounting
…/EZ…
✔
✔
✔
–
–
–
–
✔
✔
–
–
–
–
–
–
Rear mounting
…/Z…
–
✔
✔
✔
✔
–
–
✔
✔
✔
✔
–
–
–
–
Rear mounting main switch
…/V/SVB…
–
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
Service distribution board mounting
…/IVS…
✔
✔
–
–
–
–
–
✔
✔
✔
✔
–
–
–
–
Rotary switches, switch-disconnectors
Rotary switches, switch-disconnectors
7/2
Rotary switches, switch-disconnectors
7/4
System overview Rotary switches T
Moeller HPL0211-2007/2008
http://catalog.moeller.net
ON-OFF switch T0, T3, T5B, T5
2 1 3
4 10 10
ATEX 5
9 9 8 8
7
6
7 6 Control switches T0, T3, T5B, T5
1
2
3
ATEX 4 10 10
9 9
http://catalog.moeller.net
7/5
Moeller HPL0211-2007/2008
Service distribution board mounting 1 (…/IVS) Front IP30 for snap fitting to IEC/EN 60 715 top-hat rail Flush mounting • in service distribution board up to 3 height units (45 mm mounting depth) • in control panel up to 11 height units
Centre mounting (.../EZ) Front IP65 Mounting in fixing hole o 22,3 according to IEC/EN 60947-5-1 "One man mounting" by centre fixing
Main switch (mounting kit) for use as 6 Emergency-Stop device To IEC/EN 60204-1, VDE 0113 Part 1 With red rotary handle and yellow lokking ring Lockable in the 0 position a page 7/43
a page 7/21 Surface mounting (.../I...) IP65
a page 7/21
3
4 Main switch (kit)
7
Black rotary handle and locking ring Rear mounting (.../Z)
2 with an additional terminal Enclosures for metric cable glands to EN 50262 a page 7/21
Front IP65 Fixing either by snap-on or screw fixing (T0, T3) for snap fitting to IEC/EN 60 715 top-hat rail Drive coupling in door or cover
Lockable in the 0 position a page 7/43
Surface mounting,main switch (.../I...) 4 IP65
Front IP65 To IEC/EN 60 204, VDE 0113 and IEC/EN 60 947-3, for T0... up to 8 and for T3... up to 12 current paths with door interlock in "I" position a page 7/10 Flush mounting (.../E) Front IP65 Mounting and connection from rear Terminals: Crosshead screwdriver Pozidrive Finger- and back-of-hand proof
with an additional terminal with cover safety in 0 position
a page 7/21 3
Position 0 lockable with 3 padlocks Enclosures for metric cable glands to EN 50262 Label "Safety switch", colour: orange a page 7/30
ATEX a page 7/43
Thumb-grip Black thumb-grip with front plate a page 7/43
9
Coupling drive
10
Including shaft for retrofiiting of switch T0(T3)-.../XZ in rear mounting form Replacement part for T0(T3)/(P1)-.../Z for the conversion of switch T5(B)-.../E to rear mounting switch Replacement part for T5(B)/(P3)-...Z
a page 7/43 Safety switch (.../I...) IP65
T8 aways with connection bracket
Flush mounting main switch (.../EA/ SVB) Front IP65 To IEC/EN 60204, VDE 0113 and IEC/EN 60947-3, for T0... up to 8 and for T3... up to 12 current paths N and PE terminals a page 7/10
To IEC/EN 60 204, VDE 0113 and IEC/EN 60 947-3, for T0... up to 8 and for T3... up to 10 current paths Position 0 lockable with 3 padlocks Enclosures for metric cable glands to EN 50262 with an additional terminal a page 7/10
ATEX 3
8
Red thumb grip and yellow front plate a page 7/43
Connection from front a page 7/21 Rear mounting main switch (...V/SVB) 2
Thumb-grip, for use as EmergencyStop device To IEC/EN 60 204-1, VDE 0113 Part 1
5
a page 7/49
Rotary switches, switch-disconnectors
System overview Rotary switch
Rotary switches, switch-disconnectors
7/6
System overview Switch-disconnectors P
Moeller HPL0211-2007/2008
http://catalog.moeller.net
ON-OFF switches P1, P3
4 4 1
1
2
11
5 3
ATEX
11
6
10 9
8
7
ON OFF switches P5
3 4 12
2 12
13
4
13 4
4
7
7 8 8
10
10
http://catalog.moeller.net
P
Moeller HPL0211-2007/2008
Service distribution board mounting (…/ 1 IVS) Front IP30 Fitting dimensions according to DIN 43880 for snap fitting to EN 50 022 top-hat rail Space requirement P1, 3 pole: 3 PLE P3, 3 pole: 4 space units P3-,,,/IVS lockable with padlock in "0" position a page 7/21 Rear mounting (.../Z)
Flush mounting main switch (.../EA/SVB)
3
Front IP65 To IEC/EN 60204, VDE 0113 and IEC/ EN 60 947-3 N and PE terminals Position 0 lockable with 3 padlocks 2 modules can be retrofitted
2
Front IP65 Fixing either by snap-on or screw fixing
Safety switch (.../I...-SI) IP65
6
with an additional terminal with cover safety in 0 position 0 position with 3 padlocks Lockable Label "Safety switch", colour: orange
a page 7/10 Centre mounting (.../EZ)
7/7
3
Front IP65 Mounting in fixing hole o 22,3 according to IEC/EN 60 947-5-1 "One man mounting" by centre fixing
Enclosures for metric cable glands to EN 50262 a page 7/30
ATEX
a page 7/21
a page 7/43
Add-on modules 4 Switchable N conductor (early operation N/O contact) Auxiliary contacts Fingerproof
Main switch (mounting kit) for use as Emergency-Stop device
Auxiliary contact, N/O contact: always switched as load-shedding contact (late operation on, early operation off) a page 7/48
Lockable in the 0 position a page 7/43
for snap fitting to EN 50022 top-hat rail Drive coupling in door or cover Connection from front 2 modules can be retrofitted a page 7/21 Rear mounting main switch (...V/SVB)
2
Front IP65 To IEC/EN 60204, VDE 0113 and IEC/ EN 60 947-3 with door interlock in "I" position
Surface mounting (.../I...) IP65
P1: + 1, P3: + 2 Enclosures for metric cable glands to EN 50262 a page 7/21
a page 7/10 Flush mounting (.../E) Front IP65 Mounting and connection from rear Terminals: Crosshead screwdriver Pozidrive Finger- and back-of-hand proof 2 modules can be retrofitted a page 7/21
3 Surface mounting,main switch (.../I...) IP65 with an additional terminal To IEC/EN 60204, VDE 0113 and IEC/ EN 60947-3 0 position with 3 padlocks Lockable Additional modules can be retrofitted: P1: + 1, P3: + 2 Enclosures for metric cable glands to EN 50262 a page 7/10
ATEX
8
Black rotary handle and locking ring Lockable in the 0 position a page 7/43
with an additional terminal Additional modules can be retrofitted
Maintenance key for commissioning or faultfinding Position 0 lockable with 3 padlocks 2 modules can be retrofitted
To IEC/EN 60204-1, VDE 0113 Part 1 With red rotary handle and yellow lokking ring
Main switch (kit) 5
7
5
Thumb-grip, for use as Emergency-Stop device To IEC/EN 60 204-1, VDE 0113 Part 1 Red thumb-grip and yellow front plate a page 7/43
9
Thumb-grip Black thumb-grip with front plate a page 7/43
10
Coupling drive Including shaft for the retrofitting of switch T0(T3)-.../XZ to rear mounting, replacement part for T0(T3)/ (P1)-.../Z
11
for the conversion of T5(B)-.../E to rear mounting switch, replacement part for T5(B)/ (P3)-...Z a page 7/49 Protective conductor terminal Flush mounting, right Service distribution board mounting, left
12
Neutral terminal Flush mounting, left Service distribution board mounting, right
13
a page 7/43
a page 7/48
Rotary switches, switch-disconnectors
System overview Switch-disconnectors
Rotary switches, switch-disconnectors
7/8
Description Key to part numbers, modular system T0, T3, T5, T5B
Rotary switches can be used for many switching and control applications. For example as ON-OFF switches, main switches, main/control switches, instrument switches. The switch consists of a hand actuator, the switch unit and the mounting accessories
Moeller HPL0211-2007/2008
http://catalog.moeller.net
T rotary switches and P switch-disconnectors are manufactured without PCB, CFC, asbestos and silicon. The contacts are free from cadmium.
The switch chamber (contact unit = BE) contains 1 or 2 contacts In our catalogue “T Rotary Switches" are over 800 standard circuits (Please order under K115D/F/GB. Article number 077643). On the following pages a selection of oue standard circuits.
The CI-K... insulated enclosures are silicon and halogen free.
Rotary switches T0 and T3 Key to type references T......... ... - ............................- .................. ... ../ . . . . . . . . . . . . . . . . . . . . Switch size T0 or T3
Number of contact chambers = contact units (BE)
Contact sequence number
Mounting form a Page 7/2
Using the modular system to convert the mounting form
T0(3).../E
EZ-T0
V/EA/SVB-T0
T0(3).../XZ
IVS-T0
CI-K1-T0 CI-K2-T3
DE-T0
V/EA/SVB-T0
T0(3).../EZ
T0-1-(T3-1-).../EA/SVB . . . T0-4-(T3-6-).../EA/SVB
T0.../IVS1)
T0(3).../Z1)
T0-.../I1 T3-.../I2
T0-1-(T3-1-).../V/SVB . . . T0-4-(T3-6-).../V/SVB
TB5 Rotary switches Key to type references T......... ... - ............................- .................. ... ../ . . . . . . . . . . . . . . . . . . . . Switch size T5(B)
Number of contact chambers = contact units (BE)
Contact sequence number
Mounting form a Page 7/2
Using the modular system to convert the mounting form T5(B)
T5(B)...E
V/EA/SVB-T5
DE-P3
CI-K4-T5B CI-K5-T5
SVB-P3
V/EA/SVB-T5 T5(B).../Z
T5(B).../EA/SVB
T5B-.../I4 T5-.../I5
T5(B).../V/SVB
Note
1)
including shaft
T5B-.../I4/SVB T5-.../I5/SVB
http://catalog.moeller.net
P1, P3, TM
Moeller HPL0211-2007/2008
P1 and P3 Switch-disconnectors Key to type references P. . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . Switch sizes Rated uninterrupted current P1 or P3 Add-on functions due to modular system
3-pole basic unit .../E or .../Z
Mounting form a Page 7/2
Part no. suffix (if required)
Accessories from a Page 7/47
N-P...E or N-P...Z
HI 11-P1/P3E or HI 11-P1/P3Z
H-P...
UV-P...
Switched neutral Can be fitted left or right (for P1.../I: left only)
Auxiliary contact Can be fitted left or right (for P1.../I: left only)
Terminal shroud can be fitted at top or bottom
N + PE terminals, also as cover interlock on .../Z-switches.
Mini rotary switches TM The mini rotary switch TM is a particulary small switch with a small space requirement. It is ideally suited for small voltages and currents such as electronic controls. For greater safety the contacts are gold plated.
TM switches have continuous terminal markings starting with 1. Selection pages from a page 7/54
Key to type references TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . Number of contact chambers = contact units (BE)
Contact sequence number
Mounting form a Page 7/2
Accessories a Page 7/59
(see also ordering example in the electronic catalogue)
START 2 0 1 START
Bridge 1 2 3 4 5 6 7 8
Front plate inscription
Circuit representation
Connection designation
Switch from 0 to 1 contact 1 – 2 open, contact 3 – 4 open, contact 5 – 6 open, contact 7 – 8 closed
Switch from 0 to 2 contact 1 – 2 closed, contact 3 – 4 open, contact 5 – 6 open, contact 7 – 8 closed
Switch from 1 to START with automatic return to 1 contact 1 – 2 open, contact 3 – 4 closed, contact 5 – 6 open, contact 7 – 8 remains closed Switch from 2 to START with automatic return to 2 contact 1 – 2 open, contact 3 – 4 open, contact 5 – 6 closes early, contact 7 – 8 opens late
Switch from 1 to 0 contact 1 – 2 open, contact 3 – 4 open, contact 5 – 6 open, contact 7 – 8 open
Switch from 2 to 0 contact 1 – 2 open, contact 3 – 4 open, contact 5 – 6 open, contact 7 – 8 open
7/9 Rotary switches, switch-disconnectors
Ordering Key to part numbers, modular system
Ordering Load current switches, main switches, maintenance/repair switches T, P
Contact sequence Front plate no.
Main conducting paths
Moeller HPL0211-2007/2008 Auxiliary contacts
Max. motor rating
No. of poles
AC-23A 400/415 V 50-60 Hz N/ P C kW
ON OFF
N/O
N/O
FS 908
Design Rated uninterrupted current
Protection type
Part no. Article no.
http://catalog.moeller.net Price see price list
Std. pack
Iu A
Main switches, maintenance switches
0 1
1 2 3 4
0 1
1 2
0 1
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 1 0 0 6.5 20 Surface mounting IP65 T0-1-8200/I1/SVB 207145 1 0 0 6.5 20 Flush mounting Front IP65 T0-1-8200/EA/SVB 053110 1 0 0 6.5 20 Rear mounting Front IP65 T0-1-8200/V/SVB 057856 1 0 0 13 32 Surface mounting IP65 T3-1-8200/I2/SVB 207200
1 2 3 4 5 6
Rotary switches, switch-disconnectors
7/10
Notes
1
0
0
13
32
Flush mounting
Front IP65
T3-1-8200/EA/SVB 066576 T5B-1-8200/I4/SVB 207240
1
0
0
22
63
Surface mounting
IP65
1
0
0
22
63
Flush mounting
Front IP65
2
0
0
6.5
20
Surface mounting
IP65
2
0
0
6.5
20
Flush mounting
Front IP65
2
0
0
6.5
20
Rear mounting
Front IP65
2
0
0
13
32
Surface mounting
IP65
2
0
0
13
32
Flush mounting
Front IP65
2
0
0
13
32
Rear mounting
Front IP65
2
0
0
22
63
Surface mounting
IP65
2
0
0
22
63
Flush mounting
Front IP65
2
0
0
30
100
Surface mounting
IP65
3
0
0
6.5
20
Surface mounting
IP65
T0-2-1/I1/SVB 207147
3
0
0
6.5
20
Flush mounting
Front IP65
3
0
0
6.5
20
Rear mounting
Front IP65
3
0
0
13
25
Surface mounting
IP65
3
0
0
13
25
Surface mounting
3
0
0
13
25
Flush mounting
Front IP65
3
0
0
13
25
Rear mounting
Front IP65
3
0
0
15
32
Surface mounting
IP65
3
0
0
15
32
Surface mounting
3
0
0
15
32
Flush mounting
Front IP65
3
0
0
15
32
Rear mounting
Front IP65
3
0
0
37
63
Surface mounting
IP65
T0-2-1/EA/SVB 038873 T0-2-1/V/SVB 043619 P1-25/I2H/SVB1) 226900 P1-25/I2/SVB 207293 P1-25/EA/SVB 041097 P1-25/V/SVB 055335 P1-32/I2H/SVB1) 227868 P1-32/I2/SVB 207314 P1-32/EA/SVB 081438 P1-32/V/SVB 095676 P3-63/I4/SVB 207343
3
0
0
37
63
Flush mounting
Front IP65
3
0
0
37
63
Rear mounting
Front IP65
1) Enclosures
with hard metric knock-outs
T5B-1-8200/EA/SVB 094279 T0-1-102/I1/SVB 207143 T0-1-102/EA/SVB 091078 T0-1-102/V/SVB 095824 T3-1-102/I2/SVB 207198 T3-1-102/EA/SVB 014374 T3-1-102/V/SVB 019120 T5B-1-102/I4/SVB 207238 T5B-1-102/EA/SVB 094469 T5-1-102/I5/SVB 207273
P3-63/EA/SVB 031607 P3-63/V/SVB 048218
1 off
http://catalog.moeller.net Main Contact conducting sequence Front plate no. paths
Max. motor rating
No. of poles ON OFF
N/O
FS 908
T, P
Moeller HPL0211-2007/2008 Auxiliary contacts
N/O
N/ C
AC-23A 400/415 V 50-60 Hz P kW
7/11
Design Rated uninterrupted current
Protection type
Part no. Article no.
Price see price list
Std. pack
Iu A
Main switches, maintenance switches
1 2 3 4 5 6 N N
0 1
1 2 3 4 5 6 7 8
0 1
1 2 3 4 5 6
0 1
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3 0 0 45 125 Flush mounting Front IP65 P5-125/EA/SVB 280898 3 0 0 45 125 Rear mounting Front IP65 P5-125/V/SVB 280914 3 0 0 50 100 Surface mounting IP65 P3-100/I5/SVB 207373
Notes
3
0
0
50
100
Flush mounting
Front IP65
3
0
0
50
100
Rear mounting
Front IP65
3
0
0
55
160
Flush mounting
Front IP65
3
0
0
55
160
Rear mounting
Front IP65
3
0
0
90
250
Flush mounting
Front IP65
3
0
0
90
250
Rear mounting
Front IP65
3
0
0
110
315
Flush mounting
Front IP65
3
0
0
110
315
Rear mounting
Front IP65
3+N
0
0
6.5
20
Surface mounting
IP65
3+N
0
0
6.5
20
Flush mounting
Front IP65
3+N
0
0
6.5
20
Rear mounting
Front IP65
3+N
0
0
13
25
Surface mounting
IP65
3+N
0
0
13
25
Surface mounting
3+N
0
0
13
25
Flush mounting
Front IP65
3+N
0
0
13
25
Rear mounting
Front IP65
3+N
0
0
15
32
Surface mounting
IP65
3+N
0
0
15
32
Surface mounting
3+N
0
0
15
32
Flush mounting
Front IP65
3+N
0
0
15
32
Rear mounting
Front IP65
3+N
0
0
37
63
Surface mounting
IP65
3+N
0
0
37
63
Flush mounting
Front IP65
3+N
0
0
37
63
Rear mounting
Front IP65
3+N
0
0
45
125
Flush mounting
Front IP65
3+N
0
0
45
125
Rear mounting
Front IP65
3+N
0
0
50
100
Surface mounting
IP65
3+N
0
0
50
100
Flush mounting
Front IP65
3+N
0
0
50
100
Rear mounting
Front IP65
1) Enclosures
with hard metric knock-outs
P3-100/EA/SVB 074320 P3-100/V/SVB 088558 P5-160/EA/SVB 280922 P5-160/V/SVB 280928 P5-250/EA/SVB 280936 P5-250/V/SVB 280942 P5-315/EA/SVB 280950 P5-315/V/SVB 280956 T0-2-8900/I1/SVB 207151 T0-2-8900/EA/SVB 207400 T0-2-8900/V/SVB 207405 P1-25/I2H/SVB/N1) 227860 P1-25/I2/SVB/N 207298 P1-25/EA/SVB/N 081587 P1-25/V/SVB/N 086333 P1-32/I2/SVB/N 207319 P1-32/I2H/SVB/N1) 227871 P1-32/EA/SVB/N 091079 P1-32/V/SVB/N 095825 P3-63/I4/SVB/N 207349 P3-63/EA/SVB/N 010398 P3-63/V/SVB/N 015144 P5-125/EA/SVB/N 280910 P5-125/V/SVB/N 280916 P3-100/I5/SVB/N 207379 P3-100/EA/SVB/N 019890 P3-100/V/SVB/N 024636
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, main switches, maintenance/repair switches
Ordering Load current switches, main switches, maintenance/repair switches T, P
Contact sequence Front plate no. ON OFF
FS 908
Moeller HPL0211-2007/2008 Auxiliary Main conduct- contacts ing paths No. of poles N/O
N/ O
Max. motor rating AC-23A 400/415 V 50-60 Hz N P / C kW
Rated uninterrupted current
Design
Protection type
http://catalog.moeller.net
Part no. Article no.
Price see price list
Std. pack
Iu A
Main switches, maintenance switches
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 N N
0 1
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3+N 0 0 55 160 Flush mounting Front IP65
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Rotary switches, switch-disconnectors
7/12
Notes
3+N
0
0
55
160
Rear mounting
Front IP65
3+N
0
0
90
250
Flush mounting
Front IP65
3+N
0
0
90
250
Rear mounting
Front IP65
3+N
0
0
110
315
Flush mounting
Front IP65
3+N
0
0
110
315
Rear mounting
Front IP65
6
0
0
6.5
20
Surface mounting
IP65
6
0
0
6.5
20
Flush mounting
Front IP65
6
0
0
6.5
20
Rear mounting
Front IP65
6
0
0
13
32
Surface mounting
IP65
6
0
0
13
32
Flush mounting
Front IP65
6
0
0
13
32
Rear mounting
Front IP65
6
0
0
22
63
Surface mounting
IP65
6
0
0
22
63
Flush mounting
Front IP65
6
0
0
22
63
Rear mounting
Front IP65
6
0
0
30
100
Surface mounting
IP65
6
0
0
30
100
Flush mounting
Front IP65
6
0
0
30
100
Rear mounting
Front IP65
8
0
0
6.5
20
Surface mounting
IP65
8
0
0
6.5
20
Flush mounting
Front IP65
8
0
0
6.5
20
Rear mounting
Front IP65
8
0
0
13
32
Surface mounting
IP65
8
0
0
13
32
Flush mounting
Front IP65
8
0
0
13
32
Rear mounting
Front IP65
8
0
0
22
63
Surface mounting
IP65
8
0
0
22
63
Flush mounting
Front IP65
8
0
0
22
63
Rear mounting
Front IP65
8
0
0
30
100
Surface mounting
IP65
8
0
0
30
100
Flush mounting
Front IP65
1) Rated
uninterrupted current max. 95 A
P5-160/EA/SVB/N 280924 P5-160/V/SVB/N 280930 P5-250/EA/SVB/N 280938 P5-250/V/SVB/N 280944 P5-315/EA/SVB/N 280952 P5-315/V/SVB/N 280958 T0-3-8342/I1/SVB 207159 T0-3-8342/EA/SVB 029382 T0-3-8342/V/SVB 034128 T3-3-8342/I2/SVB 207208 T3-3-8342/EA/SVB 071326 T3-3-8342/V/SVB 076072 T5B-3-8342/I4/SVB 207242 T5B-3-8342/EA/SVB 092308 T5B-3-8342/V/SVB 092300 T5-3-8342/I5/SVB 207279 T5-3-8342/EA/SVB 096383 T5-3-8342/V/SVB 096381 T0-4-8344/I1/SVB 207163 T0-4-8344/EA/SVB 008267 T0-4-8344/V/SVB 014007 T3-4-8344/I2/SVB 207212 T3-4-8344/EA/SVB 008964 T3-4-8344/V/SVB 020598 T5B-4-8344/I4/SVB 207248 T5B-4-8344/EA/SVB 092062 T5B-4-8344/V/SVB 092056 T5-4-8344/I5/SVB1) 207283 T5-4-8344/EA/SVB 095961
1 off
http://catalog.moeller.net Contact sequence Front plate no. ON
Auxiliary contacts
Max. motor rating
OFF
FS 908
T, P
Moeller HPL0211-2007/2008
Main conducting paths No. of poles N/O
N/O
N/C
AC-23A 400/415 V 50-60 Hz P kW
7/13
Rated uninterrupted current
Design
Protection type
Part no. Article no.
Std. pack Price see price list
Iu A
Main switches, maintenance switches
1 2 3 4 5 6 13 14 21 22
0 1
1 2 3 4 5 6 13 14
0 1
1 2 3 4 5 6 7 8
0 1
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3 1 0 6.5 20 Surface IP65 mounting
Notes
T0-2-15679/I1/SVB 207149
3
1
0
6.5
20
Flush mounting
Front IP65
3
1
0
6.5
20
Rear mounting
Front IP65
3
1
0
45
125
Flush mounting
Front IP65
3
1
0
45
125
Rear mounting
Front IP65
3
1
0
55
160
Flush mounting
Front IP65
3
1
0
55
160
Rear mounting
Front IP65
3
1
0
90
250
Flush mounting
Front IP65
3
1
0
90
250
Rear mounting
Front IP65
3
1
0
110
315
Flush mounting
Front IP65
3
1
0
110
315
Rear mounting
Front IP65
3
1
1
13
25
Surface mounting
IP65
P1-25/I2/SVB/HI11 207297
3
1
1
13
25
Surface mounting
IP65
P1-25/I2H/SVB/HI111) 226902
3
1
1
13
25
Flush mounting
Front IP65
3
1
1
13
25
Rear mounting
Front IP65
P1-25/EA/SVB/HI11 091080 P1-25/V/SVB/HI11 095826
3
1
1
15
32
Surface mounting
IP65
P1-32/I2/SVB/HI11 207318
3
1
1
15
32
Surface mounting
IP65
P1-32/I2H/SVB/HI111) 227870
3
1
1
15
32
Flush mounting
Front IP65
3
1
1
15
32
Rear mounting
Front IP65
P1-32/EA/SVB/HI11 072567 P1-32/V/SVB/HI11 015145
3
1
1
37
63
Surface mounting
IP65
P3-63/I4/SVB/HI11 207348
3
1
1
37
63
Flush mounting
Front IP65
3
1
1
37
63
Rear mounting
Front IP65
P3-63/EA/SVB/HI11 019891 P3-63/V/SVB/HI11 024637
3
1
1
50
100
Surface mounting
IP65
P3-100/I5/SVB/HI11 207378
3
1
1
50
100
Flush mounting
Front IP65
3
1
1
50
100
Rear mounting
Front IP65
P3-100/EA/SVB/HI11 029383 P3-100/V/SVB/HI11 034129
1) Enclosures
with hard metric knock-outs
T0-2-15679/EA/SVB 081588 T0-2-15679/V/SVB 086334 P5-125/EA/SVB/HI10 280899 P5-125/V/SVB/HI10 280915 P5-160/EA/SVB/HI10 280923 P5-160/V/SVB/HI10 280929 P5-250/EA/SVB/HI10 280937 P5-250/V/SVB/HI10 280943 P5-315/EA/SVB/HI10 280951 P5-315/V/SVB/HI10 280957
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, main switches, maintenance/repair switches
Ordering Load current switches, main switches, maintenance/repair switches T, P
Contact sequence Front plate no. ON
Moeller HPL0211-2007/2008 Main conducting paths
Auxiliary contacts
Max. motor Rated unin- Design rating terrupted current
Protection type
http://catalog.moeller.net
Part no. Article no.
OFF
FS 908
No. of poles N/O
AC-23A 400/415 V 50-60 Hz N/C P kW
N/ O
Price Std. pack see price list
Iu A
Main switches, maintenance switches
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 N N 13 14 21 22
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 3 2 1 6.5 20 Surface mounting IP65
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Rotary switches, switch-disconnectors
7/14
3
2
1
6.5
20
Flush mounting
Front IP65
3
2
1
6.5
20
Rear mounting
Front IP65
3
2
1
13
32
Surface mounting
IP65
3
2
1
13
32
Flush mounting
Front IP65
3+N
1
1
6.5
20
Surface mounting
IP65
3+N
1
1
6.5
20
Flush mounting
Front IP65
3+N
1
1
13
32
Surface mounting
IP65
3+N
1
1
13
32
Flush mounting
Front IP65
3+N
1
1
13
25
Flush mounting
Front IP65
3+N
1
1
13
25
Rear mounting
Front IP65
3+N
1
1
15
32
Flush mounting
Front IP65
3+N
1
1
15
32
Rear mounting
Front IP65
3+N
1
1
37
63
Surface mounting
IP65
3+N
1
1
37
63
Flush mounting
Front IP65
3+N
1
1
37
63
Rear mounting
Front IP65
3+N
1
1
50
100
Surface mounting
IP65
3+N
1
1
50
100
Flush mounting
Front IP65
3+N
1
1
50
100
Rear mounting
Front IP65
3+N
1
1
6.5
20
Surface mounting
IP65
3+N
1
1
22
63
Surface mounting
6
1
1
6.5
20
Surface mounting
IP65
6
1
1
6.5
20
Flush mounting
Front IP65
6
1
1
6.5
20
Rear mounting
Front IP65
6
1
1
13
32
Surface mounting
IP65
6
1
1
13
32
Flush mounting
Front IP65
6
1
1
13
32
Rear mounting
Front IP65
6
1
1
22
63
Surface mounting
IP65
6
1
1
22
63
Flush mounting
Front IP65
6
1
1
22
63
Rear mounting
Front IP65
T0-3-15683/I1/SVB 207157 T0-3-15683/EA/SVB 015571 T0-3-15683/V/SVB 015634 T3-3-15683/I2/SVB 207206 T3-3-15683/EA/SVB 040478 T0-3-15680/I1/SVB 207153 T0-3-15680/EA/SVB 038875 T3-3-15680/I2/SVB 207202 T3-3-15680/EA/SVB 012002 P1-25/EA/SVB/N/HI11 048367 P1-25/V/SVB/N/HI11 053113 P1-32/EA/SVB/N/HI11 057859 P1-32/V/SVB/N/HI11 062605 P3-63/I4/SVB/N/HI11 207350 P3-63/EA/SVB/N/HI11 067351 P3-63/V/SVB/N/HI11 072097 P3-100/I5/SVB/N/HI11 207380 P3-100/EA/SVB/N/HI11 076843 P3-100/V/SVB/N/HI11 081589 T0-3-8901/I1/SVB 231934 T5B-3-8901/I4/SVB 207244 T0-4-15682/I1/SVB 207161 T0-4-15682/EA/SVB 019892 T0-4-15682/V/SVB 024638 T3-4-15682/I2/SVB 207210 T3-4-15682/EA/SVB 054716 T3-4-15682/V/SVB 059462 T5B-4-15682/I4/SVB 207246 T5B-4-15682/EA/SVB 207425 T5B-4-15682/V/SVB 207427
1 off
http://catalog.moeller.net Contact sequence Front plate no.
Auxiliary contacts
Max. motor rating
ON OFF
FS 908
T, P
Moeller HPL0211-2007/2008 Main conducting paths No. of poles N/O
AC-23A 400/415 V 50-60 Hz N/ P C kW
N/ O
7/15
Rated uninterrupted current
Design
Protection type
Part no. Article no.
Std. pack Price see price list
Iu A
Main switches, maintenance switches
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
According to IEC/EN 60204-1, VDE 0113 Part 1; with red rotary handle and yellow locking collar, lockable in 0 position As Emergency-Stop device 6
1
1
30
100
Surface mounting
IP65
T5-4-15682/I5/SVB 207281 T5-4-15682/EA/SVB 207413 T5-4-15682/V/SVB 207415
6
1
1
30
100
Flush mounting
Front IP65
6
1
1
30
100
Rear mounting
Front IP65
6
1
1
55
160
Rear mounting
Front IP65
T6-160-6/V/SVB/HI11 200619
6
1
1
55
160
Surface mounting
IP65
T6-160-6/I45/SVB/HI111) 201448
6
1
1
132
315
Rear mounting
Front IP65
T8-3-8342/V/SVB/HI112) 200620
6
1
1
132
315
Surface mounting
IP65
T8-3-8342/I48/SVB/HI11
1 off
2)3)
201450 Main switches, maintenance switches
1 2 3 4 5 6
0 1
1 2 3 4
0 1
1 2
0 1
With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 1 0 0 6.5
Notes
20
Surface mounting
IP65
1
0
0
6.5
20
Flush mounting
Front IP65
1
0
0
13
32
Surface mounting
IP65
2
0
0
6.5
20
Surface mounting
IP65
2
0
0
6.5
20
Flush mounting
Front IP65
2
0
0
6.5
20
Rear mounting
Front IP65
2
0
0
13
32
Surface mounting
IP65
2
0
0
13
32
Flush mounting
Front IP65
3
0
0
6.5
20
Surface mounting
IP65
3
0
0
6.5
20
Flush mounting
Front IP65
3
0
0
6.5
20
Rear mounting
Front IP65
3
0
0
13
25
Surface mounting
IP65
3
0
0
13
25
Surface mounting
IP65
3
0
0
13
25
Flush mounting
Front IP65
3
0
0
13
25
Rear mounting
Front IP65
1) Enclosures
without flanges with K95/1N/BR KS4-CI and K150/1/BR: Ingress protection IP64 uninterrupted current 315 A in enclosed version max. 275 A 4) Enclosures with hard metric knock-outs 2) with
3) Rated
T0-1-8200/I1/SVB-SW 207146 T0-1-8200/EA/SVB-SW 055483 T3-1-8200/I2/SVB-SW 207201 T0-1-102/I1/SVB-SW 207144 T0-1-102/EA/SVB-SW 093451 T0-1-102/V/SVB-SW 022330 T3-1-102/I2/SVB-SW 207199 T3-1-102/EA/SVB-SW 016747 T0-2-1/I1/SVB-SW 207148 T0-2-1/EA/SVB-SW 041246 T0-2-1/V/SVB-SW 045992 P1-25/I2/SVB-SW 207294 P1-25/I2H/SVB-SW4) 227861 P1-25/EA/SVB-SW 048365 P1-25/V/SVB-SW 050738
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, main switches, maintenance/repair switches
Ordering Load current switches, main switches, maintenance/repair switches T, P
Contact sequence Front plate no. ON
Main conducting paths
Moeller HPL0211-2007/2008 Auxiliary contacts
Max. motor Rated rating uninterrupted current
No. of poles
AC-23A 400/415 V 50-60 Hz N P /C kW
OFF
FS 908
N/O
N/O
Design
Protection type
Part no. Article no.
Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Rear mounting Flush mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Surface mounting Flush mounting Rear mounting Surface mounting Flush mounting Rear mounting
IP65
P1-32/I2/SVB-SW 207315 P1-32/I2H/SVB-SW1) 227872 P1-32/EA/SVB-SW 053111 P1-32/V/SVB-SW 055484 P3-63/I4/SVB-SW 207344 P3-63/EA/SVB-SW 057857 P3-63/V/SVB-SW 060230 P3-100/I5/SVB-SW 207374 P3-100/EA/SVB-SW 062603 P3-100/V/SVB-SW 064976 P5-125/EA/SVB-SW 280911 P5-125/V/SVB-SW 280917 P5-160/EA/SVB-SW 280925 P5-160/V/SVB-SW 280931 P5-250/EA/SVB-SW 280939 P5-250/V/SVB-SW 280945 P5-315/EA/SVB-SW 280953 T0-2-8900/I1/SVB-SW 207152 T0-2-8900/EA/SVB-SW 207401 T0-2-8900/V/SVB-SW 207406 P1-25/I2/SVB-SW/N 207296 P1-25/I2H/SVB-SW/N1) 227863 P1-25/EA/SVB-SW/N 083960 P1-25/V/SVB-SW/N 088706 P1-32/I2/SVB-SW/N 207317 P1-32/I2H/SVB-SW/N1) 227874 P1-32/EA/SVB-SW/N 093452 P1-32/V/SVB-SW/N 098198 P3-63/I4/SVB-SW/N 207346 P3-63/EA/SVB-SW/N 012771 P3-63/V/SVB-SW/N 017517
http://catalog.moeller.net Price see price list
Std. pack
Iu A
Main switches, maintenance switches
0 1
1 2 3 4 5 6 7 8
0 1
1 2 3 4 5 6
0 1
With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function
1 2 3 4 5 6 N N
Rotary switches, switch-disconnectors
7/16
Notes
3
0
0
15
32
3
0
0
15
32
3
0
0
15
32
3
0
0
15
32
3
0
0
37
63
3
0
0
37
63
3
0
0
37
63
3
0
0
50
100
3
0
0
50
100
3
0
0
50
100
3
0
0
45
125
3
0
0
45
125
3
0
0
55
160
3
0
0
55
160
3
0
0
90
250
3
0
0
90
250
3
0
0
110
315
3+N
0
0
6.5
20
3+N
0
0
6.5
20
3+N
0
0
6.5
20
3+N
0
0
13
25
3+N
0
0
13
25
3+N
0
0
13
25
3+N
0
0
13
25
3+N
0
0
15
32
3+N
0
0
15
32
3+N
0
0
15
32
3+N
0
0
15
32
3+N
0
0
37
63
3+N
0
0
37
63
3+N
0
0
37
63
1) Enclosures
with hard metric knock-outs
IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 IP65 Front IP65 Front IP65 IP65 Front IP65 Front IP65
1 off
http://catalog.moeller.net Contact sequence Front plate no. ON OFF
FS 908
T, P
Moeller HPL0211-2007/2008 Auxiliary Main conduct- contacts ing paths No. of poles N/O
N/ O
Max. motor rating
N/ C
AC-23A 400/415 V 50-60 Hz P kW
7/17
Rated uninterrupted current
Design
Protection type
Part no. Article no.
Surface mounting
IP65
P3-100/I5/SVB-SW/N 207376 P3-100/EA/SVB-SW/N 022263 P3-100/V/SVB-SW/N 027009 P5-125/EA/SVB-SW/N 280913 P5-125/V/SVB-SW/N 280919 P5-160/EA/SVB-SW/N 280927 P5-160/V/SVB-SW/N 280933 P5-250/EA/SVB-SW/N 280941 P5-250/V/SVB-SW/N 280947 P5-315/EA/SVB-SW/N 280955 T0-3-8342/I1/SVB-SW 207160 T0-3-8342/EA/SVB-SW 031755 T0-3-8342/V/SVB-SW 036501 T3-3-8342/I2/SVB-SW 207209 T3-3-8342/EA/SVB-SW 073699 T3-3-8342/V/SVB-SW 078445 T5B-3-8342/I4/SVB-SW 207243 T5B-3-8342/EA/SVB-SW 092307 T5B-3-8342/V/SVB-SW 092299 T5-3-8342/I5/SVB-SW 207280 T5-3-8342/EA/SVB-SW 096382 T5-3-8342/V/SVB-SW 096380 T0-4-8344/I1/SVB-SW 207164 T0-4-8344/EA/SVB-SW 008268 T3-4-8344/I2/SVB-SW 207213 T3-4-8344/EA/SVB-SW 008965 T3-4-8344/V/SVB-SW 008967 T5B-4-8344/I4/SVB-SW 207249 T5B-4-8344/EA/SVB-SW 092061 T5-4-8344/I5/SVB-SW1) 207284
Price see price list
Std. pack
Iu A
Main switches, maintenance switches
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 N N
0 1
With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3+N 0 0 50 100
Notes
3+N
0
0
50
100
Flush mounting
Front IP65
3+N
0
0
50
100
Rear mounting
Front IP65
3+N
0
0
45
125
Flush mounting
Front IP65
3+N
0
0
45
125
Rear mounting
Front IP65
3+N
0
0
55
160
Flush mounting
Front IP65
3+N
0
0
55
160
Rear mounting
Front IP65
3+N
0
0
90
250
Flush mounting
Front IP65
3+N
0
0
90
250
Rear mounting
Front IP65
3+N
0
0
110
315
Flush mounting
Front IP65
6
0
0
6.5
20
Surface mounting
IP65
6
0
0
6.5
20
Flush mounting
Front IP65
6
0
0
6.5
20
Rear mounting
Front IP65
6
0
0
13
32
Surface mounting
IP65
6
0
0
13
32
Flush mounting
Front IP65
6
0
0
13
32
Rear mounting
Front IP65
6
0
0
22
63
Surface mounting
IP65
6
0
0
22
63
Flush mounting
Front IP65
6
0
0
22
63
Rear mounting
Front IP65
6
0
0
30
100
Surface mounting
IP65
6
0
0
30
100
Flush mounting
Front IP65
6
0
0
30
100
Rear mounting
Front IP65
8
0
0
6.5
20
Surface mounting
IP65
8
0
0
6.5
20
Flush mounting
Front IP65
8
0
0
13
32
Surface mounting
IP65
8
0
0
13
32
Flush mounting
Front IP65
8
0
0
13
32
Rear mounting
Front IP65
8
0
0
22
63
Surface mounting
IP65
8
0
0
22
63
Flush mounting
Front IP65
8
0
0
30
100
Surface mounting
IP65
1) Rated
uninterrupted current max. 95 A
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, main switches, maintenance/repair switches
Ordering Load current switches, main switches, maintenance/repair switches T, P
Contact sequence Front plate no. ON
Moeller HPL0211-2007/2008
Auxiliary Main conduct- contacts ing paths
OFF
FS 908
No. of poles N/O
N/ O
Max. motor Rated rating uninterrupted current AC-23A 400/415 V 50-60 Hz Iu N P / C kW A
Design
Protection type
Part no. Article no.
Surface mounting
IP65
T0-2-15679/I1/SVB-SW 207150 T0-2-15679/EA/SVB-SW 083961 T0-2-15679/V/SVB-SW 088707 P5-125/EA/SVB-SW/HI10 280912 P5-125/V/SVB-SW/HI10 280918 P5-160/EA/SVB-SW/HI10 280926 P5-160/V/SVB-SW/HI10 280932 P5-250/EA/SVB-SW/HI10 280940 P5-250/V/SVB-SW/HI10 280946 P5-315/V/SVB-SW/HI10 280960 P1-25/I2/SVB-SW/HI11 207295 P1-25/I2H/SVB-SW/HI111) 227862 P1-25/EA/SVB-SW/HI11 070194 P1-25/V/SVB-SW/HI11 098199 P1-32/I2/SVB-SW/HI11 207316 P1-32/I2H/SVB-SW/HI111) 227873 P1-32/EA/SVB-SW/HI11 012772 P1-32/V/SVB-SW/HI11 017518 P3-63/I4/SVB-SW/HI11 207345 P3-63/EA/SVB-SW/HI11 022264 P3-63/V/SVB-SW/HI11 027010 P3-100/I5/SVB-SW/HI11 207375 P3-100/EA/SVB-SW/HI11 031756 P3-100/V/SVB-SW/HI11 036502 T0-3-15683/I1/SVB-SW 207158 T0-3-15683/EA/SVB-SW 015600 T3-3-15683/I2/SVB-SW 207207 T3-3-15683/EA/SVB-SW 042851 T0-3-15680/I1/SVB-SW 207154 T0-3-15680/EA/SVB-SW 041248 T3-3-15680/I2/SVB-SW 207203
http://catalog.moeller.net Price see price list
Std. pack
Main switches, maintenance switches
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 13 14 21 22
0 1
1 2 3 4 5 6 7 8
0 1
With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3 1 0 6.5 20
1 2 3 4 5 6 7 8 9 10 11 12
Rotary switches, switch-disconnectors
7/18
Notes
3
1
0
6.5
20
Flush mounting
Front IP65
3
1
0
6.5
20
Rear mounting
Front IP65
3
1
0
45
125
Flush mounting
Front IP65
3
1
0
45
125
Rear mounting
Front IP65
3
1
0
55
160
Flush mounting
Front IP65
3
1
0
55
160
Rear mounting
Front IP65
3
1
0
90
250
Flush mounting
Front IP65
3
1
0
90
250
Rear mounting
Front IP65
3
1
0
110
315
Rear mounting
Front IP65
3
1
1
13
25
Surface mounting
IP65
3
1
1
13
25
Surface mounting
IP65
3
1
1
13
25
Flush mounting
Front IP65
3
1
1
13
25
Rear mounting
Front IP65
3
1
1
15
32
Surface mounting
IP65
3
1
1
15
32
Surface mounting
IP65
3
1
1
15
32
Flush mounting
Front IP65
3
1
1
15
32
Rear mounting
Front IP65
3
1
1
37
63
Surface mounting
IP65
3
1
1
37
63
Flush mounting
Front IP65
3
1
1
37
63
Rear mounting
Front IP65
3
1
1
50
100
Surface mounting
IP65
3
1
1
50
100
Flush mounting
Front IP65
3
1
1
50
100
Rear mounting
Front IP65
3
2
1
6.5
20
Surface mounting
IP65
3
2
1
6.5
20
Flush mounting
Front IP65
3
2
1
13
32
Surface mounting
IP65
3
2
1
13
32
Flush mounting
Front IP65
3+N
1
1
6.5
20
Surface mounting
IP65
3+N
1
1
6.5
20
Flush mounting
Front IP65
3+N
1
1
13
32
Surface mounting
IP65
1) Enclosures
with hard metric knock-outs
1 off
http://catalog.moeller.net Contact sequence Front plate no. ON OFF
FS 908
T, P
Moeller HPL0211-2007/2008 Auxiliary Main conduct- contacts ing paths No. of poles N/O
N/ O
7/19
Max. motor Rated rating uninterrupted current AC-23A 400/415 V 50-60 Hz N/ P Iu C kW A
Design
Protection type
Part no. Article no.
Flush mounting
Front IP65
P1-25/EA/SVB-SW/N/HI11 050740 P1-32/EA/SVB-SW/N/HI11 060232 P1-32/V/SVB-SW/N/HI11 064978 P3-63/I4/SVB-SW/N/HI11 207347 P3-63/EA/SVB-SW/N/HI11 069724 P3-63/V/SVB-SW/N/HI11 074470 P3-100/I5/SVB-SW/N/HI11 207377 P3-100/EA/SVB-SW/N/HI11 079216 P3-100/V/SVB-SW/N/HI11 083962 T0-3-8901/EA/SVB-SW 231933 T3-3-8901/I2/SVB-SW 218988 T5B-3-8901/I4/SVB-SW 207245 T5B-3-8901/EA/SVB-SW 207421 T5-3-8901/I5/SVB-SW 207278 T0-4-15682/I1/SVB-SW 207162 T0-4-15682/EA/SVB-SW 022265 T0-4-15682/V/SVB-SW 027011 T3-4-15682/I2/SVB-SW 207211 T3-4-15682/EA/SVB-SW 057089 T3-4-15682/V/SVB-SW 061835 T5B-4-15682/I4/SVB-SW 207247 T5B-4-15682/EA/SVB-SW 207426 T5B-4-15682/V/SVB-SW 207428 T5-4-15682/I5/SVB-SW 207282 T5-4-15682/EA/SVB-SW 207414 T5-4-15682/V/SVB-SW 207416 T6-160-6/I45/SVB-SW/HI11
Price see price list
Std. pack
Main switches, maintenance switches
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
With black rotary handle and locking collar, lockable in the 0 position Without Emergency-Stop function 3+N 1 1 13 25 3+N
1
1
15
32
Flush mounting
Front IP65
3+N
1
1
15
32
Rear mounting
Front IP65
3+N
1
1
37
63
Surface mounting
IP65
3+N
1
1
37
63
Flush mounting
Front IP65
3+N
1
1
37
63
Rear mounting
Front IP65
3+N
1
1
50
100
Surface mounting
IP65
3+N
1
1
50
100
Flush mounting
Front IP65
3+N
1
1
50
100
Rear mounting
Front IP65
3+N
1
1
6.5
20
Flush mounting
Front IP65
3+N
1
1
13
32
Surface mounting
IP65
3+N
1
1
22
63
Surface mounting
IP65
3+N
1
1
22
63
Flush mounting
Front IP65
3+N
1
1
30
100
Surface mounting
IP65
6
1
1
6.5
20
Surface mounting
IP65
6
1
1
6.5
20
Flush mounting
Front IP65
6
1
1
6.5
20
Rear mounting
Front IP65
6
1
1
13
32
Surface mounting
IP65
6
1
1
13
32
Flush mounting
Front IP65
6
1
1
13
32
Rear mounting
Front IP65
6
1
1
22
63
Surface mounting
IP65
6
1
1
22
63
Flush mounting
Front IP65
6
1
1
22
63
Rear mounting
Front IP65
6
1
1
30
100
Surface mounting
IP65
6
1
1
30
100
Flush mounting
Front IP65
6
1
1
30
100
Rear mounting
Front IP65
6
1
1
55
160
Surface mounting
IP65
1)
Notes
6
1
1
55
160
Rear mounting
Front IP65
6
1
1
132
315
Surface mounting
IP65
6
1
1
132
315
Rear mounting
Front IP65
1) Enclosures
without flanges with K95/1N/BR KS4-CI and K150/1/BR: IP64 3) Rated uninterrupted current 315 A in enclosed version max. 275 A 2) with
201447 T6-160-6/V/SVB-SW/HI11 200127 T8-3-8342/I48/SVB-SW/ HI112)3) 201449 T8-3-8342/V/SVB-SW/HI113) 200128
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, main switches, maintenance/repair switches
Ordering Load current switches, main switches, maintenance/repair switches T, P
Contact sequence Front plate no. ON
Main conducting paths
Moeller HPL0211-2007/2008 Auxiliary contacts
Max. motor rating
No. of poles
AC-23A
Rated uninterrupted current Iu
Design
Protection type
Part no. Article no.
Flush mounting Distribution board mounting
Front IP65
T0-1-8200/E-RT 009474 T0-1-8200/IVS-RT 081956
http://catalog.moeller.net Price see price list
Std. pack
OFF
FS 908
N/O
N/O
N/C
400/415 V 50-60 Hz P kW
A
6.5
20
On-Off switches
0 1
1 2 3 4 5 6
0 1
1 2 3 4
0 1
1 2
0 1
As Emergency-Stop device According to IEC/EN60204-1, VDE 113 Part 1 with red thumb grip and yellow front plate 1 0 0
1 2 3 4 5 6 7 8
Rotary switches, switch-disconnectors
7/20
Front IP30
1
0
0
6.5
20
2
0
0
6.5
20
Surface mounting
IP65
T0-1-102/I1-RT 207062
2
0
0
6.5
20
Front IP65
2
0
0
22
32
3
0
0
6.5
20
Flush mounting Flush mounting Surface mounting
T0-1-102/E-RT 009046 T3-1-102/E-RT 016318 T0-2-1/I1-RT 207082
3
0
0
6.5
20
Front IP65
3
0
0
6.5
20
Flush mounting Distribution board mounting
3
0
0
13
25
Surface mounting
IP65
P1-25/I2-RT 207300
3
0
0
13
25
Front IP65
3
0
0
13
25
Flush mounting Distribution board mounting
P1-25/E-RT 002388 P1-25/IVS-RT 013140
3
0
0
15
32
Front IP65
3
0
0
15
32
Flush mounting Distribution board mounting
3
0
0
37
63
Front IP65
3
0
0
37
63
Flush mounting Distribution board mounting
3
0
0
50
100
Surface mounting
IP65
P3-100/I5-RT 207382
3
0
0
50
100
Front IP65
3
0
0
50
100
Flush mounting Distribution board mounting
P3-100/E-RT 007189 P3-100/IVS-RT 086185
3+N
0
0
6.5
20
Flush mounting
Front IP65
Front IP65 IP65
Front IP30
Front IP30
Front IP30
Front IP30
Front IP30
T0-2-1/E-RT 011082 T0-2-1/IVS-RT 084329
P1-32/E-RT 003197 P1-32/IVS-RT 022632
P3-63/E-RT 005743 P3-63/IVS-RT 045845
T0-2-8900/E-RT 207399
1 off
http://catalog.moeller.net Contact sequence Front plate no. ON
Main conducting paths
Part no. Article no.
Std. pack
20
Surface mounting
IP65
T0-1-8200/I1 207074 T0-1-8200/E 067352 T0-1-8200/IVS 074471
1 off
N/ O
AC-23A 400/415 V 50-60 Hz P kW
Iu A
0
6.5
N/O
0 1
1 2
0 1 1 2 3 4 0 1 1 2 3 4 5 6
Protection type
Max. motor rating
On-Off switches with black thumb grip and front plate Without auxiliary contacts 1 0
Notes
Design
Auxiliary contacts
No. of poles
FS 908
T, P
Moeller HPL0211-2007/2008
OFF
N/ C
Rated uninterrupted current
1
0
0
6.5
20
Flush mounting
Front IP65
1
0
0
6.5
20
Distribution board mounting
Front IP30
1
0
0
6.5
20
Centre mounting
Front IP65
1
0
0
6.5
20
Rear mounting
Front IP65
1
0
0
13
32
Flush mounting
Front IP65
1
0
0
13
32
Surface mounting
IP65
1
0
0
13
32
Centre mounting
Front IP65
1
0
0
22
63
Flush mounting
Front IP65
2
0
0
6.5
20
Surface mounting
IP65
2
0
0
6.5
20
Flush mounting
Front IP65
2
0
0
6.5
20
Distribution board mounting
Front IP30
2
0
0
6.5
20
Centre mounting
Front IP65
2
0
0
6.5
20
Rear mounting
Front IP65
2
0
0
22
32
Surface mounting
IP65
2
0
0
22
32
Flush mounting
Front IP65
2
0
0
22
32
Centre mounting
Front IP65
2
0
0
22
32
Rear mounting
Front IP65
2
0
0
22
63
Flush mounting
Front IP65
3
0
0
6.5
20
Surface mounting
IP65
3
0
0
6.5
20
Flush mounting
Front IP65
3
0
0
6.5
20
Distribution board mounting
Front IP30
3
0
0
6.5
20
Centre mounting
Front IP65
3
0
0
6.5
20
Rear mounting
Front IP65
3
0
0
13
25
Surface mounting
IP65
3
0
0
13
25
Surface mounting
IP65
3
0
0
13
25
Flush mounting
Front IP65
3
0
0
13
25
Distribution board mounting
Front IP30
3
0
0
13
25
Centre mounting
Front IP65
3
0
0
13
25
Rear mounting
Front IP65
1) Enclosures
with hard metric knock-outs
7/21
T0-1-8200/EZ 069725 T0-1-8200/Z 076844 T3-1-8200/E 064208 T3-1-8200/I2 207167 T3-1-8200/EZ 066581 T5B-1-8200/E 094281 T0-1-102/I1 207061 T0-1-102/E 088709 T0-1-102/IVS 015147 T0-1-102/EZ 091082 T0-1-102/Z 095828 T3-1-102/I2 207165 T3-1-102/E 076073 T3-1-102/EZ 078446 T3-1-102/Z 083192 T5B-1-102/E 094471 T0-2-1/I1 207081 T0-2-1/E 024639 T0-2-1/IVS 031758 T0-2-1/EZ 027012 T0-2-1/Z 036504 P1-25/I2 207299 P1-25/I2H1) 226898 P1-25/E 038724 P1-25/IVS 052962 P1-25/EZ 041250 P1-25/Z 057708
Rotary switches, switch-disconnectors
Ordering Load current switches, ON/OFF switches
Ordering Load current switches, ON/OFF switches T, P
Contact sequence Front plate no. ON
Main conducting paths
Moeller HPL0211-2007/2008 Auxiliary contacts
No. of poles
Max. motor rating
Rated uninterrupted current
http://catalog.moeller.net
Design
Protection type
Part no. Article no.
Std. pack
P1-32/I2 207320 P1-32/I2H1) 227866
1off
AC-23A
OFF
400/415 V N 50-60 Hz / P C kW
FS 908
N/O
N/ O
Iu A
On-Off switches
0 1
1 2 3 4 5 6
0 1
with black thumb grip and front plate Without auxiliary contacts 3 0
0
15
32
Surface mounting
IP65
3
0
0
15
32
Surface mounting
IP65
3
0
0
15
32
Flush mounting
Front IP65
3
0
0
15
32
Distribution board mounting
Front IP30
3
0
0
15
32
Centre mounting
Front IP65
P1-32/EZ 048369
3
0
0
15
32
Rear mounting
Front IP65
3
0
0
37
63
Surface mounting
IP65
3
0
0
37
63
Flush mounting
Front IP65
3
0
0
37
63
Distribution board mounting
Front IP30
P1-32/Z 098049 P3-63/I4 207356 P3-63/E 026861 P3-63/IVS 041099
3
0
0
37
63
Rear mounting
Front IP65
3
0
0
45
125
Flush mounting
Front IP65
3
0
0
45
125
Rear mounting
Front IP65
3
0
0
50
100
Surface mounting
IP65
3
0
0
50
100
Flush mounting
Front IP65
3
0
0
50
100
Distribution board mounting
Front IP30
3
0
0
50
100
Rear mounting
Front IP65
3
0
0
55
160
Flush mounting
Front IP65
3
0
0
55
160
Rear mounting
Front IP65
3
0
0
90
250
Flush mounting
Front IP65
3
0
0
90
250
Rear mounting
Front IP65
3
0
0
110
315
Flush mounting
Front IP65
3
0
0
110
315
Rear mounting
Front IP65
3+N
0
0
6.5
20
Surface mounting
IP65
3+N
0
0
6.5
20
Flush mounting
Front IP65
T0-2-8900/E 207398
3+N
0
0
6.5
20
Distribution board mounting
Front IP30
3+N
0
0
6.5
20
Centre mounting
Front IP65
T0-2-8900/ IVS 207403 T0-2-8900/EZ 207402
3+N
0
0
6.5
20
Rear mounting
Front IP65
P1-32/E 079065 P1-32/IVS 093303
P3-63/Z 050591 P5-125/E 280897 P5-125/Z 280920 P3-100/I5 207381 P3-100/E 067201 P3-100/IVS 081439 P3-100/Z 090931 P5-160/E 280921 P5-160/Z 280934 P5-250/E 280935 P5-250/Z 280948 P5-315/E 280949 P5-315/Z 280962 T0-2-8900/I1 207109
1 2 3 4 5 6 7 8
Rotary switches, switch-disconnectors
7/22
Notes
1) Enclosures
with hard metric knock-outs
T0-2-8900/Z 207407
http://catalog.moeller.net Contact sequence Front plate no.
Auxiliary contacts
Max. motor rating
ON OFF
T, P
Moeller HPL0211-2007/2008
Main conducting paths No. of poles
7/23
Rated uninterrupted current
Design
Protection type
Part no. Article no.
P1-25/I2/N 207303 P1-25/I2H/N1) 226901
Price see price list
Std. pack
AC-23A
FS 908
N/O
400/415 V N/C 50-60 Hz P kW
Iu A
0
13
25
Surface mounting
IP65
N/O
On-Off switches
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 N N
0 1
with black thumb grip and front plate Without auxiliary contacts 3+N 0
Notes
3+N
0
0
13
25
Surface mounting
IP65
3+N
0
0
13
25
Flush mounting
Front IP65
3+N
0
0
13
25
Front IP30
3+N
0
0
13
25
Distribution board mounting Centre mounting
3+N
0
0
13
25
Rear mounting
Front IP65
3+N
0
0
15
32
Surface mounting
IP65
3+N
0
0
15
32
Surface mounting
IP65
3+N
0
0
15
32
Flush mounting
Front IP65
3+N
0
0
15
32
Front IP30
3+N
0
0
15
32
Distribution board mounting Centre mounting
3+N
0
0
15
32
Rear mounting
Front IP65
3+N
0
0
37
63
Surface mounting
IP65
3+N
0
0
37
63
Flush mounting
Front IP65
3+N
0
0
37
63
Front IP30
3+N
0
0
37
63
Distribution board mounting Rear mounting
3+N
0
0
50
100
Surface mounting
IP65
3+N
0
0
50
100
Flush mounting
Front IP65
3+N
0
0
50
100
Front IP30
3+N
0
0
50
100
Distribution board mounting Rear mounting
6
0
0
6.5
20
Surface mounting
IP65
6
0
0
6.5
20
Flush mounting
Front IP65
6
0
0
6.5
20
Front IP30
6
0
0
6.5
20
Distribution board mounting Centre mounting
6
0
0
6.5
20
Rear mounting
Front IP65
6
0
0
22
32
Surface mounting
IP65
6
0
0
22
32
Flush mounting
Front IP65
6
0
0
22
63
Surface mounting
IP65
6
0
0
22
63
Flush mounting
Front IP65
1) Enclosures
with hard metric knock-outs
Front IP65
Front IP65
Front IP65
Front IP65
Front IP65
P1-25/E/N 076845 P1-25/IVS/N 083964 P1-25/EZ/N 079218 P1-25/Z/N 088710 P1-32/I2/N 207324 P1-32/I2H/N1) 227869 P1-32/E/N 093456 P1-32/IVS/N 010402 P1-32/EZ/N 095829 P1-32/Z/N 015148 P3-63/I4/N 207360 P3-63/E/N 019894 P3-63/IVS/N 022267 P3-63/Z/N 027013 P3-100/I5/N 207385 P3-100/E/N 031759 P3-100/IVS/N 034132 P3-100/Z/N 038878 T0-3-8342/I1 207131 T0-3-8342/E 043624 T0-3-8342/IVS 050743 T0-3-8342/EZ 045997 T0-3-8342/Z 055489 T3-3-8342/I2 207187 T3-3-8342/E 045225 T5B-3-8342/I4 207226 T5B-3-8342/E 092310
1off
Rotary switches, switch-disconnectors
Ordering Load current switches, ON/OFF switches
Ordering Load current switches, ON/OFF switches T, P
Contact sequence Front plate no.
Moeller HPL0211-2007/2008 Main conducting paths
Auxiliary contacts
Max. motor rating
ON OFF
FS 908
No. of poles
N/O
Rated uninterrupted current
Design
Protection type
Part no. Article no.
http://catalog.moeller.net Price see price list
Std. pack
AC-23A
N/O N/C
400/415 V 50-60 Hz P kW
Iu A
On-Off switches with black thumb grip and front plate Without auxiliary contacts 8
0
6.5
20
Surface mounting
IP65
T0-4-8344/I1 207139
8
0
0
6.5
20
Flush mounting
Front IP65
8
0
0
6.5
20
Distribution board mounting
Front IP30
T0-4-8344/E 014000 T0-4-8344/IVS 014006
8
0
0
6.5
20
Centre mounting
Front IP65
T0-4-8344/EZ 014002
8
0
0
22
63
Surface mounting
IP65
T5B-4-8344/I4 207233
3
1
0
6.5
20
Surface mounting
IP65
T0-2-15679/I1 207094
3
1
0
6.5
20
Flush mounting
Front IP65
3
1
0
6.5
20
Distribution board mounting
Front IP30
T0-2-15679/E 029387 T0-2-15679/IVS 036506
3
1
0
6.5
20
Rear mounting
Front IP65
T0-2-15679/Z 041252
3
1
1
6.5
20
Surface mounting
IP65
T0-3-8901/I1 231941
3
1
1
6.5
20
Flush mounting
Front IP65
3
1
1
13
25
Surface mounting
IP65
T0-3-8901/E 231938 P1-25/I2H/HI111) 226899
3
1
1
15
32
Surface mounting
IP65
P1-32/I2H/HI111) 227867
3
2
1
6.5
20
Surface mounting
IP65
T0-3-15683/I1 207118
6
1
1
6.5
20
Surface mounting
IP65
T0-4-15682/I1 207135
6
1
1
6.5
20
Flush mounting
Front IP65
6
1
1
22
32
Surface mounting
IP65
T0-4-15682/E 010405 T3-4-15682/I2 207190
6
1
1
22
32
Flush mounting
Front IP65
6
1
1
22
63
Surface mounting
IP65
6
1
1
22
63
Flush mounting
Front IP65
6
1
1
22
63
Rear mounting
Front IP65
6
1
1
30
100
Surface mounting
IP65
1) Enclosures
with hard metric knock-outs
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
0
1 off
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 13 14 21 22
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 7 8
0 1
With auxiliary contacts
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Rotary switches, switch-disconnectors
7/24
Notes
T3-4-15682/E 023869 T5B-4-15682/I4 207229 T5B-4-15682/E 207424 T5B-4-15682/Z 207429 T5-4-15682/I5 207269
1 off
http://catalog.moeller.net
T0, T3, T5(B), T6, T8
Moeller HPL0211-2007/2008 Design
Protection type
Part no. Article no.
20
Surface mounting
IP65
T0-1-8210/I1 207076
6.5
20
Flush mounting
Front IP65
1
6.5
20
Distribution board mounting
Front IP30
T0-1-8210/E 012742 T0-1-8210/IVS 074440
1
6.5
20
Centre mounting
Front IP65
T0-1-8210/EZ 048337
1
13
32
Flush mounting
Front IP65
1
22
63
Surface mounting
IP65
T3-1-8210/E 054718 T5B-1-8210/I4 207432
1
22
63
Flush mounting
Front IP65
1
22
63
Rear mounting
Front IP65
2
6.5
20
Surface mounting
IP65
2
6.5
20
Flush mounting
Front IP65
2
6.5
20
Distribution board mounting
Front IP30
2
6.5
20
Centre mounting
Front IP65
T0-2-8211/EZ 053083
2
13
32
Surface mounting
IP65
T3-2-8211/I2 207178
2
13
32
Flush mounting
Front IP65
2
13
32
Centre mounting
Front IP65
T3-2-8211/E 061837 T3-2-8211/EZ 003075
2
13
32
Rear mounting
Front IP65
2
22
63
Surface mounting
IP65
2
22
63
Flush mounting
Front IP65
2
22
63
Rear mounting
Front IP65
3
6.5
20
Surface mounting
IP65
3
6.5
20
Flush mounting
Front IP65
3
6.5
20
Distribution board mounting
Front IP30
3
6.5
20
Centre mounting
Front IP65
T0-3-8212/EZ 057829
3
6.5
20
Rear mounting
Front IP65
T0-3-8212/Z 036473
Main conducting paths
Max. motor rating
No. of poles
AC-23A 400/415 V 50-60 Hz P
Iu
kW
A
With black thumb-grip and grey front plate With 0 (Off) position Group switches, mains transfer switches 0 1
6.5
1
Contact sequence
Front plate no.
N/O
7/25
Rated uninterrupted current
Price see price list
Std. pack
2 0 1
Changeover switches
2 0 1
1 2 3 4
1
2
FS 684
0
2 0 1
1 2 3 4 5 6 7 8
1
2
FS 684
0
1 2 3 4 5 6 7 8 9 10 11 12
1
FS 684
2
T5B-1-8210/E 094261 T5B-1-8210/Z 094258 T0-2-8211/I1 207102 T0-2-8211/E 022234 T0-2-8211/IVS 076813
T3-2-8211/Z 064210 T5B-2-8211/I4 207220 T5B-2-8211/E 093094 T5B-2-8211/Z 093082 T0-3-8212/I1 207123 T0-3-8212/E 029353 T0-3-8212/IVS 079186
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, changeover switches
Ordering Load current switches, changeover switches T0, T3, T5(B), T6, T8
Contact sequence
Main conducting paths No. of poles
Front plate no.
Moeller HPL0211-2007/2008 Max. motor rating
Rated uninterrupted current
Design
Protection type
Part no. Article no.
http://catalog.moeller.net Price see price list
Std. pack
AC-23A 400/415 V 50-60 Hz P
Iu
kW
A
3
13
32
Surface mounting
IP65
T3-3-8212/I2 207183
3
13
32
Flush mounting
Front IP65
3
13
32
Centre mounting
Front IP65
T3-3-8212/E 068956 T3-3-8212/EZ 003080
3
13
32
Rear mounting
Front IP65
3
22
63
Surface mounting
IP65
3
22
63
Flush mounting
Front IP65
3
22
63
Rear mounting
Front IP65
3
30
100
Flush mounting
Front IP65
3
30
100
Surface mounting
IP65
3
30
100
Rear mounting
Front IP65
3
45
125
Flush mounting
Front IP65
3
132
315
Flush mounting
Front IP65
4
6.5
20
Surface mounting
IP65
4
6.5
20
Flush mounting
Front IP65
4
6.5
20
Front IP30
4
6.5
20
Distribution board mounting Centre mounting
Front IP65
4
6.5
20
Rear mounting
Front IP65
4
13
32
Surface mounting
IP65
4
13
32
Flush mounting
Front IP65
4
13
32
Rear mounting
Front IP65
4
22
63
Surface mounting
IP65
4
22
63
Flush mounting
Front IP65
4
22
63
Rear mounting
Front IP65
4
30
100
Surface mounting
IP65
4
30
100
Flush mounting
Front IP65
4
30
100
Rear mounting
Front IP65
N/O
Changeover switches
2 0 1
With black thumb-grip and grey front plate With 0 (Off) position Group switches, mains transfer switches 0
1 2 3 4 5 6 7 8 9 10 11 12
1
2
FS 684
1 0 2
0 2
1 0 2
1 2 3 4 5 6 7 8 9 10 11 12 101 102 103 104 105 106
1
0 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Rotary switches, switch-disconnectors
7/26
FS 684
2
T3-3-8212/Z 071329 T5B-3-8212/I4 207223 T5B-3-8212/E 092386 T5B-3-8212/Z 092383 T5-3-8212/E 096466 T5-3-8212/I5 207266 T5-3-8212/Z 096464 T6-3-8212/E/HI12 214781 T8-3-8212/E/HI12 214782 T0-4-8213/I1 207136 T0-4-8213/E 031726 T0-4-8213/IVS 081559 T0-4-8213/EZ 062575 T0-4-8213/Z 043592 T3-4-8213/I2 207191 T3-4-8213/E 076075 T3-4-8213/Z 078448 T5B-4-8213/I4 207230 T5B-4-8213/E 092112 T5B-4-8213/Z 092109 T5-4-8213/I5 207270 T5-4-8213/E 096014 T5-4-8213/Z 096012
1 off
http://catalog.moeller.net Contact sequence
T0, T3, T5(B), T6, T8
Moeller HPL0211-2007/2008
Protection type
Part no. Article no.
AC-23A 400/415 V 50-60 Hz P
Iu
kW
A
4
6.5
20
Surface mounting
IP65
T0-4-8294/I1 207138
4
6.5
20
Flush mounting
Front IP65
4
6.5
20
Distribution board mounting
Front IP30
T0-4-8294/E 010371 T0-4-8294/IVS 043594
4
13
32
Surface mounting
IP65
T3-4-8294/I2 207193
4
13
32
Flush mounting
Front IP65
4
13
32
Rear mounting
Front IP65
T3-4-8294/E 002513 T3-4-8294/Z 004886
4
22
63
Surface mounting
IP65
T5B-4-8294/I4 207232
4
22
63
Flush mounting
Front IP65
4
22
63
Rear mounting
Front IP65
T5B-4-8294/E 092084 T5B-4-8294/Z 092081
4
30
100
Surface mounting
IP65
T5-4-8294/I5 207433
4
30
100
Flush mounting
Front IP65
4
30
100
Rear mounting
Front IP65
T5-4-8294/E 095986 T5-4-8294/Z 095984
0
4
13
32
Flush mounting
Front IP65
FS 161629
4
13
32
Flush mounting
Front IP65
4
13
32
Flush mounting
IP65
4
13
32
Flush mounting
Front IP65
4
22
63
Flush mounting
Front IP65
4
22
63
Surface mounting
IP65
4
22
63
Rear mounting
Front IP65
T5B-4-8902/Z 207431
4
30
100
Flush mounting
Front IP65
4
30
100
Surface mounting
IP65
T5-4-8902/E 207418 T5-4-8902/I5 207214
4
30
100
Rear mounting
Front IP65
Main conducting paths No. of poles
N/O
Max. motor rating
Design
Rated uninterrupted current
Front plate no.
7/27
Price see price list
Std. pack
Changeover switches
1 0 2
With black thumb-grip and grey front plate With 0 (Off) position Group switches, mains transfer switches 0 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1
Mains 0 Stand-by
FS 953
NOTSTROM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
NETZ
T3-4-8902/E 215222 T3-4-8902/EZ 215223 T3-4-8902/I2 215224 T3-4-8902/Z 215225 T5B-4-8902/E 207430 T5B-4-8902/I4 207237
T5-4-8902/Z 207419
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, changeover switches
Ordering Load current switches, changeover switches T0, T3, T5(B), T6, T8
Contact sequence
Front plate no.
Moeller HPL0211-2007/2008 Max. motor rating
Design
Protection type
Part no. Article no.
AC-23A
Rated uninterrupted current
400/415 V 50-60 Hz P
Iu
kW
A
6.5
20
Surface mounting
IP65
T0-1-8214/I1 207077
1
6.5
20
Flush mounting
Front IP65
1
6.5
20
Front IP30
1
6.5
20
Distribution board mounting Centre mounting
1
6.5
20
Rear mounting
Front IP65
2
6.5
20
Surface mounting
IP65
T0-1-8214/E 019863 T0-1-8214/IVS 045967 T0-1-8214/EZ 076815 T0-1-8214/Z 050720 T0-2-8215/I1 207103
2
6.5
20
Flush mounting
Front IP65
2
6.5
20
Front IP30
2
6.5
20
Distribution board mounting Centre mounting
3
6.5
20
Surface mounting
IP65
3
6.5
20
Flush mounting
Front IP65
3
6.5
20
Centre mounting
Front IP65
3
13
32
Surface mounting
IP65
3
13
32
Flush mounting
Front IP65
T3-3-8216/E 023870
1
6.5
20
Surface mounting
IP65
T0-1-8220/I1 207078
1
6.5
20
Flush mounting
Front IP65
1
6.5
20
Front IP30
1
6.5
20
Distribution board mounting Centre mounting
1
6.5
20
Rear mounting
Front IP65
2
6.5
20
Surface mounting
IP65
T0-1-8220/E 031728 T0-1-8220/IVS 055459 T0-1-8220/EZ 095799 T0-1-8220/Z 086312 T0-2-8221/I1 207104
2
6.5
20
Flush mounting
Front IP65
2
6.5
20
Front IP30
2
6.5
20
Distribution board mounting Centre mounting
2
22
32
Surface mounting
IP65
2
22
32
Flush mounting
Front IP65
2
22
63
Surface mounting
IP65
2
22
63
Flush mounting
Front IP65
Main conducting paths No. of poles
N/O
http://catalog.moeller.net Price see price list
Std. pack
Changeover switches
FS 4011
Front IP65
Front IP65
1 2 3 4 5 6 7 8 9 10 11 12
1
0
2
1 2 3 4 5 6 7 8
1
0
2
1 2 3 4
1
0
2
With black thumb-grip and grey front plate With 0 (Off) position With spring-return from both directions to 0 0 1 1 2
1 off
T0-2-8215/E 022236 T0-2-8215/IVS 048340 T0-2-8215/EZ 081561 T0-3-8216/I1 207434 T0-3-8216/E 024609 T0-3-8216/EZ 086307 T3-3-8216/I2 207184
1 2
Without 0 (Off) position Changeover switches
1 2
1 2 3 4
1
1 2 3 4 5 6 7 8
Rotary switches, switch-disconnectors
7/28
2
FS 943
Front IP65
Front IP65
T0-2-8221/E 038847 T0-2-8221/IVS 057832 T0-2-8221/EZ 010372 T3-2-8221/I2 207180 T3-2-8221/E 045227 T5B-2-8221/I4 207221 T5B-2-8221/E 093047
1 off
http://catalog.moeller.net
1
T0, T3, T5(B), T6, T8
Moeller HPL0211-2007/2008
Contact sequence Front plate no. 2
FS 943
7/29
Main conducting paths
Max. motor rating
No. of poles N/O
AC-23A
Rated uninterrupted current
Design
Protection type
Part no. Article no.
T0-3-8222/I1 207124 T0-3-8222/E 048339 T0-3-8222/IVS 060205 T0-3-8222/EZ 015118 T3-3-8222/E 052346 T3-3-8222/I2 207185 T5B-3-8222/I4 207224 T5B-3-8222/E 092378 T5B-3-8222/Z 092375 T0-4-8223/I1 207137 T0-4-8223/E 050712 T0-4-8223/IVS 062578 T0-4-8223/EZ 019864 T0-4-8223/Z 086315 T3-4-8223/I2 207192 T3-4-8223/E 059465 T3-4-8223/Z 061838 T5B-4-8223/I4 207231 T5B-4-8223/E 092108 T5B-4-8223/Z 092105 T0-5-8369/E 060204 T3-5-8369/I2 207536 T3-5-8369/E 066584 T0-6-8370/E 062577 T0-6-8370/IVS 067324 T0-6-8370/EZ 029356 T3-6-8370/E 073703 T0-8-8372/E 064950 T0-8-8372/IVS 069697 T3-8-8372/E 080822
400/415 V 50-60 Hz P kW
Iu A
3
6.5
20
Surface mounting
IP65
3
6.5
20
Flush mounting
Front IP65
3
6.5
20
Front IP30
3
6.5
20
Distribution board mounting Centre mounting
Front IP65
3
13
32
Flush mounting
Front IP65
3
22
32
Surface mounting
IP65
3
22
63
Surface mounting
IP65
3
22
63
Flush mounting
Front IP65
3
22
63
Rear mounting
Front IP65
4
6.5
20
Surface mounting
IP65
4
6.5
20
Flush mounting
Front IP65
4
6.5
20
Front IP30
4
6.5
20
Distribution board mounting Centre mounting
Front IP65
4
6.5
20
Rear mounting
Front IP65
4
13
32
Surface mounting
IP65
4
13
32
Flush mounting
Front IP65
4
13
32
Rear mounting
Front IP65
4
22
63
Surface mounting
IP65
4
22
63
Flush mounting
Front IP65
4
22
63
Rear mounting
Front IP65
5
6.5
20
Flush mounting
Front IP65
5
22
32
Surface mounting
IP65
5
22
32
Flush mounting
Front IP65
6
6.5
20
Flush mounting
Front IP65
6
6.5
20
Front IP30
6
6.5
20
Distribution board mounting Centre mounting
Front IP65
6
22
32
Flush mounting
Front IP65
8
6.5
20
Flush mounting
Front IP65
8
6.5
20
Front IP30
8
22
32
Distribution board mounting Flush mounting
Price Std. see pack price list
Changeover switches
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
1 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2
1 2 3 4 5 6 7 8 9 10 11 12
1 2
1 2 3 4 5 6 7 8 9 10 11 12
1 2
with black thumb grip and front plate Without 0 (Off) position Changeover switches
Front IP65
1
Rotary switches, switch-disconnectors
Ordering Load current switches, changeover switches
Ordering Load-current switch - Safety switch P1, P3, T5(B)
Contact sequence
Front plate no.
Moeller HPL0211-2007/2008
Main conducting paths No. of poles
Auxiliary contacts
ON
FS 908
N/O
Max. motor rating
Rated uninterrupted current
http://catalog.moeller.net
Design
Part no. Article no.
Surface mounting IP65
P1-25/I2-SI 207308 P1-32/I2-SI 207329 P3-63/I4-SI 207361 P3-100/I5-SI 207386 P1-25/I2-SI/N 207312 P1-32/I2-SI/N 207333 P3-63/I4-SI/N 207365 P3-100/I5-SI/N 207390 P1-25/I2-SI/HI11 207310 P1-32/I2-SI/HI11 207331 P3-63/I4-SI/HI11 207363 P3-100/I5-SI/HI11 207388 T5B-3-8342/I4-SI 207250 T5-3-8342/I5-SI 207447 T5B-4-15682/I4-SI 207254 T5-4-15682/I5-SI 207285 T5B-4-8903/I4-SI 207258 T5-4-8903/I5-SI 207289
1 off
P1-25/I2-SI-SW 207309 P1-32/I2-SI-SW 207330 P3-63/I4-SI-SW 207362
1 off
Price see price list
Std. pack
AC-23A
OFF
N/O
N/C
400/415 V 50-60 Hz P
Iu
kW
A
Safety switches with warning label For use as Emergency-Stop device1) 3
0
13
25
3
0
0
15
32
3
0
0
37
63
3
0
0
50
100
3+N
0
0
13
25
3+N
0
0
15
32
3+N
0
0
37
63
3+N
0
0
50
100
3
1
1
13
25
3
1
1
15
32
3
1
1
37
63
3
1
1
50
100
6
0
0
22
63
6
0
0
30
100
6
1
1
22
63
6
1
1
30
100
6
2
0
22
63
6
2
0
30
100
3
0
0
13
25
3
0
0
15
32
3
0
0
37
63
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 13 14 21 22
0 1
1 2 3 4 5 6 N N
0 1
1 2 3 4 5 6
0 1
0
1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off 1 off
0 1
Without Emergency-Stop function2)
1 2 3 4 5 6
Rotary switches, switch-disconnectors
7/30
Notes
1) According 2) With
to IEC/EN 60204-1, VDE 0113 Part 1 black rotary handle and locking ring
Surface mounting IP65
1 off 1 off
http://catalog.moeller.net
Main conducting paths
Front plate no.
No. of poles
Auxiliary contacts
ON OFF
FS 908
P1, P3, T5(B)
Moeller HPL0211-2007/2008
Contact sequence
N/O
N/O
N/C
7/31
Max. motor rating
Rated uninterrupted current
AC-23A 400/415 V 50-60 Hz P
Iu
kW
A
Design
Part no. Article no.
Surface mounting IP65
P1-25/I2-SI/N-SW 207313 P1-32/I2-SI/N-SW 207334 P3-100/I5-SI/N-SW 207391 P1-25/I2-SI/HI11-SW 207311 P1-32/I2-SI/HI11-SW 207332 P3-63/I4-SI/HI11-SW 207364 P3-100/I5-SI/HI11-SW 207389 T5B-3-8342/I4-SI-SW 207251
1 off
T5B-4-15682/I4-SI-SW 207255 T5-4-15682/I5-SI-SW 207286 T5-4-8903/I5-SI-SW 207290
1 off
Price see price list
Std. pack
3+N
0
0
13
25
3+N
0
0
15
32
3+N
0
0
50
100
3
1
1
13
25
3
1
1
15
32
3
1
1
37
63
3
1
1
50
100
6
0
0
22
63
6
1
1
22
63
6
1
1
30
100
6
2
0
30
100
1 off 1 off 1 off 1 off 1 off 1 off 1 off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 13 14 21 22
0 1
1 2 3 4 5 6 N N
0 1
Without Emergency-Stop function
Engineering Maintenance, repair and safety switches all have the same electrical function. They are designed to safely isolate electrical installations (loads) from mains power during maintenance and repair work and to ensure that a hazard does not arise which endangers personnel, machinery and production materials. Safety switches are main switches with an additional enclosure. Installed in the immediate vicinity of the motor or the electrical load they act as switchdisconnectors for that load. It makes possible work without danger according to DIN EN 50110/VDE 0105. This is particularly important if there is any danger of the main switch being inadvertently operated. Application By securing the switch in the OFF position with his own padlock (up to 3 can be fitted), the fitter/electrician can protect himself against the possibility of any other person switching the machine on. Maintenance switches are merely additional, enclosed main switches with a padlocking facility. Enclosed main switch with padlock interlock a 7/10 a 7/30 Features • Safety switches are housed in insulated enclosures and bear the inscription “Safety switch” on a bright orange label. • With special red handle and yellow locking ring for Emergency_Stop use according to STOP category O IEC/EN 60204/VDE 0113. • If the switch is not usable for Emergency_Stop both parts are black (partno. suffix "SW") • The cover and handle can be interlocked by fitting a padlock. Selection Switches must be selected according to the following criteria: 1) according to motor switching capacity, when the switch is fitted in so that the operator may use it for operational ON and OFF switching. 2) The rating data always applies for 3 poles. When the motor rating is divided between 6 poles, such as for star-delta starting, a 6-pole switch can be used to control 1.73 times the rated power. 3) If the switch has a load-shedding contact (LA), you can select the appropriate switch according to the uninterrupted current. The load-shedding contact is an auxiliary contact, which is closed in the ON position and opens early when switching off, so that a contactor located in the circuit takes over the switching capacity and the maintenance/safety switch operates at zero load. When switching on, the loadshedding contact closes later than or at the same time as the main contacts. With P and T switches this is the N/O auxiliary contact.
1 off 1 off
4) The "ON" position can be locked using a padlock (after altering the handle) This is not permissable for switches with red/yellow handles. Example: Safety switch with load shedding and annunciation L1 L2 L3 N F1
F0 1
3
FAZB4/1-HS 95
5
F2
Q11 2
4
96
6
21
F2
O 22 13
I
14
1
3
5
7
9
11
2
4
6
8
10
12
U
V
W
Q1
M 3
P1
P2
Q11
13
Q11
A1 A2
14
Rotary switches, switch-disconnectors
Ordering Load-current switch - Safety switch
Ordering Load current switch - reversing switch T0, T3, T5B
Contact sequence
Front plate no.
Moeller HPL0211-2007/2008
Main conducting paths
Max. motor rating
No. of poles N/O
AC-23A
Rated uninterrupted current
400/415 V 50-60 Hz P kW
Iu A
6.5
20
Design
Protection type
Part no. Article no.
Surface mounting
IP65
Flush mounting
Front IP65
Distribution board mounting
Front IP30
T0-2-8400/I1 207111 T0-2-8400/E 053079 T0-2-8400/IVS 060198
Surface mounting
IP65
Flush mounting
Front IP65
Surface mounting
IP65
Flush mounting
Front IP65
Surface mounting
IP65
Flush mounting
Front IP65
Distribution board mounting Centre mounting
Front IP30
Rear mounting
Front IP65
Surface mounting
IP65
Flush mounting
Front IP65
Centre mounting
Front IP65
Rear mounting
Front IP65
Surface mounting
IP65
Flush mounting
Front IP65
Rear mounting
Front IP65
Surface mounting
IP65
Flush mounting
Front IP65
Centre mounting
Front IP65
Surface mounting
IP65
http://catalog.moeller.net Price see price list
Std. pack
Reversing switches with 0 (Off) position with black thumb grip and front plate Without spring-return 1 0 2
0 1
2
2
1 2 3 4 5 6 7 8
FS 684
22
32
63
1 0 2
0 1
2
3
6.5
20
1 2 3 4 5 6 7 8 9 10
FS 684
22
32
63
Front IP65
1 off
T3-2-8400/I2 207181 T3-2-8400/E 073695 T5B-2-8400/I4 207222 T5B-2-8400/E 092918 T0-3-8401/I1 207132 T0-3-8401/E 091047 T0-3-8401/IVS 098166 T0-3-8401/EZ 093420 T0-3-8401/Z 010366
1 off
T3-3-8401/I2 207188 T3-3-8401/E 030992 T3-3-8401/EZ 000694 T3-3-8401/Z 035739 T5B-3-8401/I4 207227 T5B-3-8401/E 092296 T5B-3-8401/Z 092293
2
With spring-return from both directions to 0 0
2
3
6.5
20
1
0
1
FS 4011 1 2 3 4 5 6 7 8 9 10
Rotary switches, switch-disconnectors
7/32
22
32
T0-3-8228/I1 207125 T0-3-8228/E 015112 T0-3-8228/EZ 048334
1 off
T3-3-8228/I2 207186
1 off
http://catalog.moeller.net
T0, T3, T5(B)
Moeller HPL0211-2007/2008
Contact sequence
Front plate no.
Main conducting paths No. of poles N/O
7/33
AC-23A
Design Rated uninterrupted current
400/415 V 50-60 Hz P kW
Iu A
6.5
20
Max. motor rating
Protection Part no. type Article no.
Price see price list
Std. pack
Star-delta switches 0 y d
with black thumb grip and front plate 3
Y 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FS 635
22
32
Surface mounting Flush mounting Distribution board mounting
T0-4-8410/I1 207140 Front IP65 T0-4-8410/E 024604 Front IP30 T0-4-8410/IVS 064945
Centre mounting
Front IP65 T0-4-8410/EZ 053080
Rear mounting
Front IP65 T0-4-8410/Z 083929
Surface mounting Flush mounting
IP65
Centre mounting
IP65
1 off
T3-4-8410/I2 207195 Front IP65 T3-4-8410/E 009657 Front IP65 T3-4-8410/EZ 000721
Rear mounting
Front IP65 T3-4-8410/Z 012030
63
Surface mounting Flush mounting
IP65
T5B-4-8410/I4 207234 Front IP65 T5B-4-8410/E 092052
6.5
20
Flush mounting
Front IP65 T0-5-15876/E 000893
22
32
Surface mounting Flush mounting
IP65
Reversing Star-delta switches
d y 0 y d
with black thumb grip and front plate Two-way switches 0 Y
Y
3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
FS 638
d y 0 y d
Rear mounting
Y
0
63
Y
Flush mounting Flush mounting
T3-5-15876/I2 207537 Front IP65 T3-5-15876/E 016776 Front IP65 T3-5-15876/Z 019149 Front IP65 T5B-5-15876/E 214785 Front IP65 T5B-5-15876/Z 214786
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
FS 4017
1 off
Reversing multi-speed switches with black thumb grip and front plate Two-speed, two directions, for one tapped winding 2 1 0 1 2
0 1 2
1 2
3
6.5
20
Flush mounting Centre mounting Rear mounting
Front IP65 T0-6-15866/Z 067326
2 1 0 1 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
FS 629
1 2
0
1 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
FS 441
3
Front IP65 T0-6-15866/E 055460 Front IP65 T0-6-15866/EZ 012747
22
32
Flush mounting
Front IP65 T3-6-15866/E 054744
22
63
Flush mounting
Front IP65 T5B-7-15866/E 214788
1 off
1 off
Rotary switches, switch-disconnectors
Ordering Load current switches, (reversing) star-delta switches, (reversing) multi-speed switches
Ordering Control switch, multi-speed switch T0, T3, T5B
Contact sequence
Moeller HPL0211-2007/2008 Main conducting paths No. of poles
Front plate no.
N/O
Max. motor rating
http://catalog.moeller.net
Design
Protection type
Part no. Article no.
Surface mounting
IP65
Flush mounting
Front IP65
T0-3-8451/I1 207133 T0-3-8451/E 038849
Distribution board mounting
Front IP30
T0-3-8451/IVS 026985
Centre mounting
Front IP65
T0-3-8451/EZ 083936
Surface mounting
IP65
Flush mounting
Front IP65
T3-3-8451/I2 207189 T3-3-8451/E 028641
Surface mounting
IP65
Flush mounting
Front IP65
Distribution board mounting
Front IP30
T0-4-8440/IVS 029358
Centre mounting
Front IP65
T0-4-8440/EZ 088682
Rear mounting
Front IP65
T0-4-8440/Z 048342
Surface mounting
IP65
Flush mounting
Front IP65
T3-4-8440/I2 207196 T3-4-8440/E 035760
63
Flush mounting
Front IP65
T5B-4-8440/E 092032
20
Surface mounting
IP65
Flush mounting
Front IP65
T0-4-8441/I1 207142 T0-4-8441/E 043595
Distribution board mounting
Front IP30
T0-4-8441/IVS 031731
Surface mounting
IP65
Flush mounting
Front IP65
T3-4-8441/I2 207197 T3-4-8441/E 042879
Rear mounting
Front IP65
Rated uninterrupted current
Price see price list
Std. pack
AC-23A
400/415 V 50-60 Hz P
Iu
kW
A
6.5
20
Multi-speed switches
0 1 2
with black thumb grip and front plate Two-speed, non reversing, for 2 separate windings 1 3 2 1 2 3 4 5 6 7 8 9 10 11 12
0
FS 644
22
32
1 off
2-speed, 1 directions, for tapped winding 0 1 2
1 2
0
3
6.5
20
1 off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FS 644
T0-4-8440/I1 207141 T0-4-8440/E 041222
22
1 0 2
0 1
2
3
6.5
32
FS 684 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Rotary switches, switch-disconnectors
7/34
22
32
63
T5B-4-8441/Z 092025
1 off
http://catalog.moeller.net
T0
Moeller HPL0211-2007/2008
Contact sequence
Front plate no.
No. of poles
Design
Protection type
Part no. Article no.
1
Surface mounting
IP 65
T0-1-8240/I1 207079
Flush mounting
Front IP 65
Centre mounting
Front IP 65
T0-1-8240/E 034105 T0-1-8240/EZ 043597
Surface mounting
IP 65
T0-2-8241/I1 207107
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
Front IP 30
T0-2-8241/E 050716 T0-2-8241/IVS 057835 T0-2-8241/EZ 053089
Surface mounting
IP 65
T0-2-8242/I1 207108
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
Front IP 30
T0-2-8242/E 067327 T0-2-8242/IVS 074446 T0-2-8242/EZ 069700
Surface mounting
IP 65
T0-3-8243/I1 207128
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
Front IP 30
T0-3-8243/E 081565 T0-3-8243/IVS 088684 T0-3-8243/EZ 083938
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
Front IP 30
Surface mounting
IP 65
T0-3-8280/I1 207130
Flush mounting
Front IP 65
Centre mounting
Front IP 65
T0-3-8280/E 034106 T0-3-8280/EZ 036479
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
Front IP 30
Rear mounting
Front IP 65
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
Front IP 30
Step switches
0 1 2
With black thumb-grip and grey front plate One contact closed per step (without overlap) With 0 (Off) position 1 0
2
0 1 2 3
1 2 3 4
FS 418
1 0
2
3
1
0 1 2 3 4
1 2 3 4 5 6
FS 420
1 0
2
3 4
1
0 1 2 3 4 5
1 2 3 4 5 6 7 8
FS 422
1 0
2
3 4 5
1
0 1 2 3 4 5 6
1 2 3 4 5 6 7 8 9 10
FS 424
1 0
2
3 4 5
6
1
Front IP 65
Front IP 65
Front IP 65
Front IP 65
0 1 2
1 2 3 4 5 6 7 8 9 10 11 12
FS 426
0 1 2 3
1 2 3 4 5 6 7 8 9 10 11 12
1 0
3
2
FS 418
1 0
2
3
3
0 1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
FS 420
1 0
2
3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
FS 422
7/35
3
Front IP 65
Front IP 65
T0-3-8244/E 095803 T0-3-8244/IVS 012749 T0-3-8244/EZ 098176
T0-5-8281/E 048344 T0-5-8281/IVS 055463 T0-5-8281/EZ 050717 T0-5-8281/Z 057836 T0-6-8282/E 062582 T0-6-8282/IVS 069701 T0-6-8282/EZ 064955
Price see price list
Std. pack
Rotary switches, switch-disconnectors
Ordering Control switch, step switch
Ordering Control switch, step switch T0
Contact sequence
Moeller HPL0211-2003 Front plate no.
http://catalog.moeller.net
No. of poles
Design
Protection type
Part no. Article no.
Price see price list
Std. pack
1
Surface mounting
IP65
T0-1-8220/I1 207078
1 off
1
Flush mounting
Front IP65
1 off
1
Front IP30
1
Distribution board mounting Centre mounting
1
Rear mounting
Front IP65
1
Surface mounting
IP 65
T0-1-8220/E 031728 T0-1-8220/IVS 055459 T0-1-8220/EZ 095799 T0-1-8220/Z 086312 T0-2-8230/I1 207105
1
Flush mounting
Front IP 65
1 off
1
Front IP 30
1
Distribution board mounting Centre mounting
1
Surface mounting
IP 65
T0-2-8230/E 088685 T0-2-8230/IVS 095804 T0-2-8230/EZ 091058 T0-2-8231/I1 207106
1
Flush mounting
Front IP 65
1 off
1
Front IP 30
1
Distribution board mounting Centre mounting
1
Flush mounting
Front IP 65
1
Front IP 30
1
Distribution board mounting Centre mounting
1
Surface mounting
IP 65
T0-2-8231/E 012750 T0-2-8231/IVS 019869 T0-2-8231/EZ 015123 T0-3-8232/E 026988 T0-3-8232/IVS 034107 T0-3-8232/EZ 029361 T0-3-8233/I1 207127
1
Flush mounting
Front IP 65
1 off
1
Front IP 30
1
Distribution board mounting Centre mounting
2
Flush mounting
Front IP 65
2
Centre mounting
Front IP 65
T0-3-8233/E 041226 T0-3-8233/IVS 048345 T0-3-8233/EZ 043599 T0-4-8251/E 013971 T0-4-8251/EZ 013972
3
Surface mounting
IP65
T0-3-8222/I1 207124
1 off
3
Flush mounting
Front IP65
1 off
3
Front IP30
3
Distribution board mounting Centre mounting
3
Flush mounting
Front IP 65
3
Front IP 30
3
Distribution board mounting Centre mounting
3
Flush mounting
Front IP 65
3
Centre mounting
Front IP 65
T0-3-8222/E 048339 T0-3-8222/IVS 060205 T0-3-8222/EZ 015118 T0-5-8270/E 091059 T0-5-8270/IVS 098178 T0-5-8270/EZ 093432 T0-6-8271/E 015124 T0-6-8271/EZ 017497
Step switches
1 2
With black thumb-grip and grey front plate One contact closed per step (without overlap) Without 0 (Off) position 2
1 2 3
1 2 3 4
1
FS 943
3
1 2 3 4 5 6
2 1
FS 404
1 2 3 4
2
3
1
Front IP65
Front IP 65
4
1 2 3 4 5
1 2 3 4 5 6 7 8
FS 606
2 1
3
4 5
1 2 3 4 5 6
1 2 3 4 5 6 7 8 910
FS 408
2 1
3
4 5 6
1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12
FS 410
2 1
3
4
Front IP 65
Front IP 65
Front IP 65
1 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FS 406
2
1 2 3
1 2 3 4 5 6 7 8 9 10 11 12
1
FS 943
2 1
3
1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
FS 404
2 1
3
4
FS 406 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Rotary switches, switch-disconnectors
7/36
Front IP65
Front IP 65
1 off 1 off 1 off 1 off
1 off 1 off 1 off
1 off 1 off 1 off 1 off 1 off 1 off
1 off 1 off 1 off 1 off
1 off 1 off 1 off 1 off 1 off 1 off 1 off
http://catalog.moeller.net
7/37
Moeller HPL0211-2003
Contact sequence
Front plate no.
No. of poles
Design
Protection type
Part no. Article no.
Price see price list
Std. pack
1
Flush mounting
Front IP 65
1 off
1
Centre mounting
Front IP 65
1
Surface mounting
IP 65
T0-1-15401/E 038854 T0-1-15401/EZ 041227 T0-1-15401/I1 207067
1
Front IP30
2
Centre mounting
Front IP 65
2
Surface mounting
IP 65
T0-1-15401/IVS 045973 T0-1-15402/E 053092 T0-1-15402/EZ 055465 T0-1-15402/I1 207068
1 off
2
Distribution board mounting Flush mounting
2
Front IP30
3
Centre mounting
Front IP 65
3
Front IP30
4
Distribution board mounting Flush mounting
4
Centre mounting
Front IP 65
T0-1-15402/IVS 060211 T0-2-15403/E 067330 T0-2-15403/EZ 069703 T0-2-15403/IVS 074449 T0-2-15404/E 081568 T0-2-15404/EZ 083941
1 off
3
Distribution board mounting Flush mounting
1
Flush mounting
Front IP 65
1 off
1
Centre mounting
Front IP 65
1
Surface mounting
IP 65
T0-1-15421/E 095806 T0-1-15421/EZ 098179 T0-1-15421/I1 207069
1
Distribution board mounting Flush mounting
Front IP30
1 off
Front IP30
2
Distribution board mounting Centre mounting
2
Rear mounting
Front IP 65
3
Surface mounting
IP 65
T0-1-15421/IVS 012752 T0-2-15422/E 019871 T0-2-15422/IVS 026990 T0-2-15422/EZ 022244 T0-2-15422/Z 029363 T0-3-15423/I1 207114
3
Flush mounting
Front IP 65
T0-3-15423/E 034109
1 off
1
Surface mounting
IP65
T0-1-15431/I1 207070
1 off
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
IP65
Rear mounting
Front IP 65
T0-1-15431/E 019872 T0-1-15431/IVS 026991 T0-1-15431/EZ 022245 T0-1-15431/Z 029364
On-Off switches
0 1
With black thumb-grip and grey front plate One contact closed per step (without overlap) 1
1 2
0
1 2 3 4 5 6 7 8
0 1
1 2 3 4 5 6
0 1
1 2 3 4
0 1
FS 415
Front IP 65
Front IP 65
Front IP 65
1 off 1 off
1 off 1 off 1 off
1 off 1 off 1 off 1 off 1 off
Changeover switches
2 0 1
With black thumb-grip and grey front plate One contact closed per step (without overlap)
1 2 3 4
2
0
1
FS 429
2 0 1
2
1 2 3 4 5 6 7 8 9 10 11 12
2 0 1
1 2 3 4 5 6 7 8
2
Front IP 65
Front IP 65
1 off 1 off
1 off 1 off 1 off 1 off 1 off
Hand/Auto switches With 0 (Off) position Without spring-return AUTO 0 HAND
0
1 2 3 4
HAND AUTO
FS 1401
Front IP 65
Rotary switches, switch-disconnectors
Ordering Control switch, ON-OFF switches, changeover switches, Hand/Auto switches
Ordering Control switch - hand/auto switch T0
Moeller HPL0211-2007/2008
Contact sequence
Hand/Auto switches With 0 (Off) position AUTO Without spring0 return HAND
0
1 2 3 4 5 6 7 8
AUTO 0 HAND
0
Design
Protection type
Part no. Article no.
2
Surface mounting
IP65
T0-2-15432/I1 207091
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
IP65
Rear mounting
Front IP 65
T0-2-15432/E 034110 T0-2-15432/IVS 041229 T0-2-15432/EZ 036483 T0-2-15432/Z 043602
Surface mounting
IP65
T0-3-15433/I1 207115
Flush mounting
Front IP 65
Distribution board mounting Centre mounting
IP65
Rear mounting
Front IP 65
T0-3-15433/E 048348 T0-3-15433/IVS 055467 T0-3-15433/EZ 050721 T0-3-15433/Z 057840
Surface mounting
IP65
T0-1-15434/I1 207071
Flush mounting
Front IP 65
Centre mounting
Front IP 65
T0-1-15434/E 062586 T0-1-15434/EZ 018053
Layout
IP65
T0-2-15435/I1 218971
Flush mounting
Front IP 65
T0-2-15435/E 003191
Surface mounting
IP65
T0-2-15907/I1 207095
Flush mounting
Front IP65
Centre mounting
Front IP65
Rear mounting
Front IP65
T0-2-15907/E 066931 T0-2-15907/EZ 069304 T0-2-15907/Z 078796
Surface mounting
IP65
T0-1-15451/I1 207072
Flush mounting
Front IP65
Distribution board mounting Centre mounting
Front IP30
Rear mounting
Front IP65
T0-1-15451/E 076824 T0-1-15451/IVS 083943 T0-1-15451/EZ 079197 T0-1-15451/Z 086316
Flush mounting
Front IP65
Distribution board mounting Centre mounting
Front IP30
Flush mounting
Front IP65
Distribution board mounting Centre mounting
Front IP30
Rear mounting
Front IP65
3
FS 1401
0
AUTO 0 HAND
No. of poles
FS 1401
HAND AUTO
1 2 3 4 5 6 7 8 9 10 11 12
With spring-return from HAND
Front plate no.
HAND AUTO
HAND AUTO
1
1 2 3 4
FS 1414000
0
AUTO 0 HAND
HAND AUTO
2
1 2 3 4 5 6 7 8
FS 1414000
START HAND 0 AUTO
AUTO
0
1
Front IP 65
Front IP 65
HAND START
1 2 3 4 5 6 7 8
With spring-return from START
Without 0 (Off) position AUTO Without springHAND return
FS 1413890
1 2 3 4
HAND AUTO
AUTO HAND
1 2 3 4 5 6 7 8 AUTO HAND
1
FS 19334
HAND AUTO
2
FS 19334
HAND AUTO
1 2 3 4 5 6 7 8 9 10 11 12
Rotary switches, switch-disconnectors
7/38
FS 19334
3
Front IP65
Front IP65
Front IP65
http://catalog.moeller.net Price see price list
Std. pack
1 off
1 off
1 off
1 off
1 off
1 off
T0-2-15452/E 091062 T0-2-15452/IVS 098181 T0-2-15452/EZ 093435
1 off
T0-3-15453/E 015127 T0-3-15453/IVS 022246 T0-3-15453/EZ 017500 T0-3-15453/Z 024619
1 off
http://catalog.moeller.net
T0
Moeller HPL0211-2007/2008
Contact sequence
Front plate no.
Pole
Design
Protection type
Part no. Article no.
1
Flush mounting
Front IP65
Centre mounting
Front IP65
T0-1-15321/E 086317 T0-1-15321/EZ 088690
2
Flush mounting
Front IP65
T0-1-15322/E 010382
3
Surface mounting
IP65
T0-2-15323/I1 207087
Flush mounting
Front IP65
T0-2-15323/E 024620
Flush mounting
Front IP65
Centre mounting
Front IP65
T0-1-15366/E 081572 T0-1-15366/EZ 083945
Surface mounting
IP65
T0-1-15511/I1 207073
Flush mounting
Front IP65
Centre mounting
Front IP65
Rear mounting
Front IP65
T0-1-15511/E 019875 T0-1-15511/EZ 022248 T0-1-15511/Z 029367
Surface mounting
IP65
T0-2-15512/I1 207093
Flush mounting
Front IP65
Centre mounting
Front IP65
T0-2-15512/E 034113 T0-2-15512/EZ 036486
Flush mounting
Front IP65
Centre mounting
Front IP65
Rear mounting
Front IP65
Flush mounting
Front IP65
Centre mounting
Front IP65
Flush mounting
Front IP65
Distribution board mounting
Front IP30
Centre mounting
Front IP65
Price see price list
Std. pack
On switches
I 1
with black thumb grip and front plate ON spring-return switches (make contact) Spring-return in position 1
1 2
1
1 2 3 4 5 6
I 1
1 2 3 4
I 1
FS 4721
1 off
1
On-Off spring-return switches Spring-return in positions 0 and 1 1
1
1 2 3 4
0
I
0
FS 456
ON-OFF spring-return switch Spring-return in START position 1
1
START 1 0
1 2 3 4
0
START
FS 147767
2
1 2 3 4 5 6 7 8
START 1 0
START 2 0 1 START
1
0
START
2 START
1 2 3 4 5 6 7 8
FS 140660
see K 115
T0-2-8177/E 015130 T0-2-8177/EZ 017503 T0-2-8177/Z 024622
Universal control switches With black thumb-grip and grey front plate
2 0 1
• 1 contact closed in each position • Additionally 1 contact closed in position 0 and 1 • Additionally 1 contact closed in position 0 and 2 • Additionally 1 contact closed in position 0 and 3 Stay-put switches with 3 positions
1 2 3 4 5 6 7 8 9 10 11 12
2
0
1
FS 429
T0-3-15391/E 029365 T0-3-15391/EZ 031738
1
Spring-return from positions 1 and 2 0
1
1 2 3 4 5 6 7 8 9 10 11 12
2
0
2
FS 458
T0-3-15394/E 072079 T0-3-15394/IVS 079198 T0-3-15394/EZ 074452
1 off
Rotary switches, switch-disconnectors
7/39
Ordering Control switch - ON switches, universal control switches
Ordering Control switches, instrument selector switches T0
Contact sequence
Moeller HPL0211-2007/2008 Front plate no.
http://catalog.moeller.net Price see price list
Std. pack
Pole
Design
Protection type
Part no. Article no.
Dual BCD CODE
Flush mounting
Front IP65
Centre mounting
Front IP65
T0-4-15602/E 029368 T0-4-15602/EZ 031741
1
Flush mounting
Front IP65
T0-1-91/E 072082
3 x phase to N with 0 (Off) position
Flush mounting
Front IP65
T0-2-15921/E 067337
1 off
3 x phase to phase + 3 x phase to N with 0 (Off) position
Flush mounting
Front IP65
1 off
Distribution board mounting
Front IP30
T0-3-8007/E 095813 T0-3-8007/IVS 012759
Centre mounting
Front IP65
Rear mounting
Front IP65
Flush mounting
Front IP65
Distribution board mounting
Front IP30
Centre mounting
Front IP65
T0-3-15924/EZ 022251
Flush mounting
Front IP65
Distribution board mounting
Front IP30
T0-2-15920/E 038861 T0-2-15920/IVS 029452
Centre mounting
Front IP65
Rear mounting
Front IP65
Flush mounting
Front IP65
Centre mounting
Front IP65
Flush mounting
Front IP65
Distribution board mounting
Front IP30
Centre mounting
Front IP65
Coding switches With black thumb-grip and grey front plate With complete rotation in both directions 0 1 2 3 4 5 6 7 8 9
1 0
2 3 4
9 8
5 6 7
1 off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FS 312
Series switches With black thumb-grip and grey front plate With 0 (Off) position (heater switches) 0 1 2
1
2
1 2 3 4
0
FS 614
Voltmeter selector switches With black thumb-grip and grey front plate L2-N L1-N L3-N 0
L3-N L2-N L1-N 0
1 2 3 4 5 6 7 8
FS 1410757
L3-N L2-N L1-N 0 L1-L2 L2-L3 L3-L1
L1-L2
0
L1-N
L2-L3
L2-N
L3-L1
L3-N
1 2 3 4 5 6 7 8 9 10 11 12
FS 1410759
L3-N L2-N L1-N L3-L1 L2-L3 L1-L2
L2-L3 L3-L1 L1-L2 L3-N
L1-N L2-N
3 x phase to phase + 3 x phase to N Without 0 position with complete rotation in both directions
1 2 3 4 5 6 7 8 9 10 11 12
FS 164721
L2-L3 L1-L2 L3-L1 0
L3-L1 L2-L3 L1-L2 0
3 x phase to phase with 0 (Off) position
1 2 3 4 5 6 7 8
FS 1410755
L2-L3 L1-L2 L3-L1
L3-L1 L2-L3 L1-L2
3 x phase to phase without 0 (Off) position
T0-3-8007/EZ 098186 T0-3-8007/Z 015132 T0-3-15924/E 019878 T0-3-15924/IVS 026997
1 off
1 off
T0-2-15920/EZ 041234 T0-2-15920/Z 048353 T0-2-15922/E 053099 T0-2-15922/EZ 055472
1 off
T0-3-8048/E 034116 T0-3-8048/IVS 041235
1 off
1 2 3 4 5 6 7 8
FS 164854
Ammeter selector switches With black thumb-grip and grey front plate With complete rotation in both directions Measurement via current transformers With 0 (Off) position
0 L1
L3 L2
FS 9440
1 2 3 4 5 6 7 8 9 10 11 12
Rotary switches, switch-disconnectors
7/40
T0-3-8048/EZ 036489
http://catalog.moeller.net Contact sequence
T0, P1
Moeller HPL0211-2007/2008
Front plate no.
No. of poles
Max. motor rating
7/41
Design
Rated uninterrupted current
Protection type
Part no. Article no.
IP65
T0-2-1/I1/SVA(S)-RT 207085 P1-25/I2/SVA(S)-RT 207306
1 off
Price see price list
Std. pack
AC-23A 400/415 V 50-60 Hz P
Iu
kW
A
Panic switch Cylinder lock SVA Key withdrawable in position 0 and 1 If the key is withdrawn in position 1 the switch can be switched off but not on again without the key.
0 1
With Emergency-Stop function According to IEC/EN 60204-1, VDE 0113 Part1 with red thumb-grip and yellow front plate 1 3 6.5 20 Layout 1 2 3 4 5 6
0
3
13
25
FS 908 GE
ON
Layout
IP65
OFF
1 off
3
6.5
20
Flush mounting
IP65
T0-2-1/E/SVA(S)-RT 228291
1 off
3
15
32
Flush mounting
IP65
P1-32/E/SVA(S)-RT 050971
1 off
Without Emergency-Stop function with black thumb grip and front plate 3 6.5
20
Layout
IP65
1 off
Layout
IP65
T0-2-1/I1/SVA(S) 207084 P1-25/I2/SVA(S) 207305
0 1
ON
1 2 3 4 5 6
OFF
3
FS 908
13
25
ON
OFF
3
6.5
20
Flush mounting
IP65
T0-2-1/E/SVA(S) 050977
1 off
3
15
32
Flush mounting
IP65
P1-32/E/SVA(S) 044977
1 off
T0-2-1/I1/SVC(S)-RT 207086
1 off
0 1
Padlocking feature SVC Interlocking slide with lock lockable in positions 0 and 1 If the interlocking slide is interlocked with lock in position 1 the switch can be switched off but not on again without removing the lock. Lockable with max. 3 padlocks. With Emergency-Stop function According to IEC/EN 60204-1, VDE 0113 Part1 with red thumb-grip and yellow front plate 1 3 6.5 20 Layout IP65 1 2 3 4 5 6
0
FS 908 GE
Notes
C
E
D
B
0
330 300
A
315
F
240
45
P
H 60
J
90 225 135 210
Q
G
30
270
R
1 off
180
N
120
150
K M
L
Code letters for lockable switch positions Letter S for panic lock with FS908GE
Rotary switches, switch-disconnectors
Ordering Switches with locking mechanism
Ordering Switches with locking mechanism T0, P1 Contact sequence
Moeller HPL0211-2007/2008
Front plate no.
No. of poles
Max. motor rating
Design
Protection type
Part no. Article no.
20
Layout
IP65
T0-1-102/I1/S 207063
1 off
Rated uninterrupted current
Product view
http://catalog.moeller.net Price see price list
Std. pack
AC-23A 400/415 V 50-60 Hz P
Iu
kW
A
On-Off switch with black thumb grip and front plate Key can only be withdrawn in position 0 (Pos A) Without Emergency-Stop function Cylinder lock SVA 2 6.5 0 1
ON
1 2 3 4
OFF
FS 908
0 1
ON
2
6.5
20
Flush mounting
IP65
T0-1-102/EZ/S 014933
1 off
3
6.5
20
Layout
IP65
1 off
3
13
25
Layout
IP65
T0-2-1/I1/SVA(A) 207083 P1-25/I2/SVA(A) 207304
1 2 3 4
OFF
FS 908
Key operation ST-0, IP53 0 1
ON OFF
1 2 3 4 5 6
Rotary switches, switch-disconnectors
7/42
FS 908
ON
OFF
3
6.5
20
Flush mounting
IP65
T0-2-1/E/SVA(A) 050976
1 off
3
13
25
Flush mounting
IP65
P1-25/E/SVA(A) 050965
1 off
3
6.5
20
Rear mounting
IP65
T0-2-1/Z/SVA(A) 050978
1 off
ON OFF
Notes
C
E
D
B
0
330 300
A
315
F
240
45
P
H 60
J
90 225 135 210
Q
G
30
270
R
1 off
180
N
120
150
K M
L
Code letters for lockable switch positions Letter S for panic lock with FS908GE
http://catalog.moeller.net
7/43
SVB-...-T0(P3), KNB-...-T0(P3)
Moeller HPL0211-2007/2008
Std. pack
Notes
SVB-T0 057892
1 off
SVB-P3 052999
1 off
• for interlocking the 0 position • for switches with positions 0 I at 90° • Switching angle as front plate FS908 • Lockable with max. 3 padlocks
SVB-SW-T0 060265
1 off
SVB-SW-P3 062491
1 off
V/EA/SVB-T0 062638 V/EA/SVB-T5 045065
1 off
T0-.../E, .../Z T3-.../E, .../Z T5(B)-.../E, .../Z
V/EA/SVB-SW-T0 065011 V/EA/SVB-SW-T5 045064
1 off
Black
–
10 off
Red, only for Emergency-Stop switch, according to IEC/EN 60204-1, VDE 0113 Part 1
–
KNB-T0 038909 KNB-RT-T0 043655
Black
–
10 off
Red, only for Emergency-Stop switch, according to IEC/EN 60204-1, VDE 0113 Part 1
–
KNB-P3 041282 KNB-RT-P3 046028
10 off
• Order additional yellow front plate FS908GE-P3
–
KNK-T0 000650
5 off
–
KNK-P3 000649
5 off
Special devices for electricians, to allow them to switch interlocked main switches On and Off, when the panel door is open for maintenance purposes (to IEC/ EN 60204-1, Clause 5.1.1.1)
T0-.../I1
+ATEX-I1 237513 +ATEX-I2 237514 +ATEX-I4 237516 +ATEX-I5 237517
1 off
For use with
Part no. Article no.
T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2 T5B-.../E, .../Z, .../I4 T5-.../E, .../Z, .../I5 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5 T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2 T5B-.../E, .../Z, .../I4 T5-.../E, .../Z, .../I5 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5
Price see price list
Main switch assembly kits Padlocking feature, exclusively for main switches Admissible on T0 up to 4 contact units Admissible on T3 up to 6 contact units as Emergency-Stop With red rotary device according to handle and yellow IEC/EN 60204-1, locking ring VDE 0113 Part 1
With black rotary handle and black locking ring
Without EmergencyStop function
Main switch assembly kits with PE terminal and N terminal T0-.../E, .../Z as Emergency-Stop With red rotary T3-.../E, .../Z device according to handle and yellow IEC/EN 60204-1, locking ring T5(B)-.../E, .../Z VDE 0113 Part 1
With black rotary handle and black locking ring
Without EmergencyStop function
1 off
1 off
• for interlocking the 0 position • for interlocking the I position when required • Lockable with max. 3 padlocks
• For conversion of T.../E flush mounting switches with front plate FS908 into T.../EA/SVB... flush mounting main switches. • For conversion of T.../Z rear mounting switches (with front plate FS908) into interlocked T.../V/SVB rear mounting main switches
Thumb-grips
Maintenance key for locked main switch For interlocked main switches For interlocked main switches
10 off
ATEX style According to 94/9EG Test Certificate BVS04E106X Only available together with basic device with metric knock-outs M20
with solid side walls
T3-.../I2 P1-.../I2 T5B-.../I4 P3-.../I4 T5-.../I5 P3-.../I5
1 off 1 off 1 off
• Order additional yellow front plate FS908GE-T0
Rotary switches, switch-disconnectors
Ordering Main switch assembly kits, thumb-grips, maintenance keys
Rotary switches, switch-disconnectors
7/44
Ordering Front plates FS…-T0(P3)
Moeller HPL0211-2007/2008
Size
Dimensions (W x H x D)
http://catalog.moeller.net
Part no. Article no.
Price see price list
Std. pack
mm Standard front plates Can be laser inscribed T0, T3, P1
45 x 45 (for size 48 x 48)
P3, T5, T5B
84 x 84 (for size 88 x 88)
FS(*)-T0 231893 FS(*)-P3 231895
10 off
FS908GE-T0 003198 FS908GE-P3 031475
5 off
FS-ALU980-P3 266906 FS-ALU980-T0 266905
10 off
10 off
Emergency-Stop front plates – T0, T3, P1
45 x 45 (for size 48 x 48)
P3, T5, T5B
84 x 84 (for size 88 x 88)
5 off
Blank plates Can be engraved P3, T5, T5B
84 x 84 (for size 88 x 88)
T0, T3, P1
45 x 45 (for size 48 x 48)
50 off
Notes Standard front plates For standard contact sequence the normal front plate can be replaced if required with the front plate shown here (not with T6, T8 and TM). This is provided the switching angle, number of positions and the position of the 0 position are the same. Switching angle 30° 1 0
23
2 1
34
318
234
1 0
309
345 2 1
317
1 0
2 34
308
5
2 1
3 45 6
2 34 5 1 6 0
316
307
315
STOP
OFF
HAND AUTO
1 0
2 34
5 6 7
2 1
345
314
6 7 8
1 0
234 8
305
5 6 7
2 1
345 9
313
6 7 8
1 0
2 3 4
9 8
304
5 6 7
2 1
345 10 9
312
6 7 8
1 0
234
10 9 8
303
345 6 7 8 1110 9
2 34 5 1 6 0 11 7 10 9 8
345 2 6 1 7 12 8 1110 9
302
310
301
2 1
5 6 7
311
Switching angle 45 1 0
0
2 1
402
AUS
OFF AUTO HAND
HAND
1411 0
1
2
415
142003
147472
HALT LINKS RECHTS
HALT ZUVOR. RUCK
STOP FORW. REV.
1420
1475
1404
1403
141538
0
0
0
0
0
2
1
458
4011 3
4 5
1 2
408 3
2 1 8
7
0
STOP
1
0
1
EIN
2
441
0
1 2
Y
0
414
0
TRIP
CLOSE
147474
0
1410757
L2-L3 L1-L2 L3-L1
R-S
0
0
14196
1410755
1
SLOW STOP FAST
0
0
0
1
0
0
START
456
START
459
1409
S-T
L1-L2 L2-L3 L3-L1 L1-N
T-R
0
1
1
START
START
14195
1410756
Y
START STOP RUN
L1-N
0
L2-N L3-N
L1-L2
EIN
1423 2
140660
0
2
4721 0
2
4722
4723 0
1
1
2
0
1
2
0
2
1
0
HAND AUTO
1410758
4026
1
STOP START
STOP
14510
STOP FORW. REV. START
START
0
L1-N
0
L2-L3
L2-N
L3-L1
L3-N
L3-L1
L1-N L2-N L3-N
147479
R-S
START
41409
429
0
OFF HAND AUTO
HAND
R-O
OFF
S-T
S-O
L1-L2 L2-L3
T-R
T-O
L3-L1
14944
2
1 0
3 4 5
AUTO
1414000 1 0
404
4 5 6
2
1 0
3
1401
2 1
3
5 7 6
410
426
412
OFF
OFF
0
S-T
S-T
L3-L1
T-R
T-R
140055
L1-L2
L3-L1
L3-N L2-N
194321
194323
1 0
4
0
1 2 3
2
3 4
422
1 2 3
1 0 7
449
2
3 4 5
6
428
START
1
L1-N
L2-L3
3
2 1
406
4
0
R-S
1413905
420
3 4 5
6
2
424 R-S
L1-L2 L2-L3
1410763
3
2 1
3
2 1
418
1413890
START
1
0
1
4117 2
1 0
HAND
142074 OFF L1-L2 L2-L3
1410759
0
REV.
2
0
2
462 AUTO
141537 START
14712 L1-L2
FORW.
496
1 2
461 1
1 AUS
1446 2
2
1
START
147767 0
1413903
141879 0
LOWER
RAISE
1 2
T-O
455 1
LINKS RECHTS
Y
S-O R-O
141883 0
4017
453 L2-N L1-N L3-N
4 5 6
ZU
14988
1426 3 4
AUF
1
1
START
AUS LANG- SCHNELL SAM
AUS
2 1
ON
START
416 AUTO
1
142010
Switching angle 60° 0
1
1
HAND AUTO
2
2
0
611
601
1601
644
OFF
OFF REV. FORW.
STOP SLOW FAST
STOP FORW. REV.
AUTO
MAN
1627
1628
16052 2
1
1665
1662
0
3
655
START
1 0
0
2 1
164222
635
16616
L2-N
L2-L3 L1-L2 L3-L1
L1-N
L3-N
0 2
2
684
164855 3
4
4
667
0
1
2
2
2
0 1 2
645
629
STOP SLOW SLOW
NOTSTROM
161629
161570 2 3
604 STOP START START
616 1
3
RUN
4
161683
618
161358 2
MED. HIGH
1
2
5
4
0
3
1610
1614 0
OFF AUTO
HAND
1673
1
2
1617
Y
4
606
6034
2
3
6
5
1
620
OFF
HAND
AUTO
3
1
160772
2
0
638
161359
AUS AUTO
HAND
AB
OFF
AUS
HALT LINKS RECHTS
AUF
LOW
0
RUN
161002
HALT AB
1
0 Y
0 AUF
3
614 Y
FAST
FAST
NETZ
1
164854 1 2
1
621 1 0
3
0
0
1
4
0
2 1
610
0
1 2
0
Y
640
Y
0
6010
L2-L3 L1-L2 L3-L1
R-S
L3-N
T-O
L2-N
L1-N
S-T T-R
S-O
164721
R-O
661
Switching angle 90° 1
ON
2
0
1
EIN
1
0
OFF
908
9508 2
910
902
0
1 0
953
190719
1
193935
2
192190
1
3
904
907
1
2
OFF
2
1
0
1
EIN
AUS
STOP
START
2
1
HAND
AUTO
ZU
AUF
AUF
AB
DOWN
UP
FAST
SLOW
1
STOP
AUS
HEIZUNGNOTSCHALTER
0
OFF
OFF
945 ON
ON
2
1992
1
1
OFF
ON
0
2
0
190334
0 0
1
943
1+2
0
19334
0
1 2
3
190550
1 1
19143
3
1
193975
0
2 2
0
L3
190431
0 L1
OFF
R
T
L3
AUTO L1
ZU
AUF
1
ON
OFF
1
2
0
2
2
3
4
L2
S
L2
AUS
926
1957
192191
923
928
9441
193840
911
912
906
9440
935
19589
1922
http://catalog.moeller.net
Moeller HPL0211-2007/2008
Explanation
Language
7/45
ZFS… For use with
Part no. Article no.
Price see price list
Std. pack
Add-on front plates, clip-on for padlocking feature consists of label mount and insert label • Inscribed with standard text "main switch only open in 0 position" in various languages • Blank, can be engraved
Blank, can be engraved
None
Rotary switches T0, T3, P1
Blank, can be engraved
None
Switch-disconnectors T5(B), P3
Engraved with standard text
German/English
Rotary switches T0, T3, P1
Engraved with standard text
Spanish
Switch-disconnectors T5(B), P3
Engraved with standard text
French
Switch-disconnectors T5(B), P3
Engraved with standard text
French
Rotary switches T0, T3, P1
Engraved with standard text
German/English
Switch-disconnectors T5(B), P3
Engraved with standard text
Italian
Rotary switches T0, T3, P1
Engraved with standard text
Spanish
Rotary switches T0, T3, P1
Engraved with standard text
Hungarian
Switch-disconnectors T5(B), P3
Engraved with standard text
Portuguese
Rotary switches T0, T3, P1
Engraved with standard text
Swedish
Rotary switches T0, T3, P1
Engraved with standard text
Hungarian
Rotary switches T0, T3, P1
Enter country reference when ordering: D = German GB = English F = French I = Italian E = Spanish
ZFS60-T0 019924 ZFS60-P3 022297 ZFS61/62-T0 030170 ZFS77-P3 047422 ZFS63-P3 047423 ZFS63-T0 047424 ZFS61/62-P3 065739 ZFS68-T0 065751 ZFS77-T0 065752 ZFS80-P3 205565 ZFS72-T0 205541 ZFS75-T0 205544 ZFS80-T0 205548
25 off
Switch-disconnector P5-.../EA/SVB Switch-disconnector P5-.../V/SVB
ZFS(*)-P5 105225
1 off
Rotary switches T0, T3, P1
ZFSX-T0 024670 ZFSX-P3 027043
25 off
BS45X14-T0 029416 BS84X24-P3 031789
25 off
Label mounts, black, plug-in type
Switch-disconnectors T5(B), P3
25 off
Insert plates
Rotary switches T0, T3, P1 Switch-disconnectors T5(B), P3
25 off
Rotary switches, switch-disconnectors
Ordering Add-on front plates
Ordering Key operation, locking interlock S…, SVA…, SVC…
Ordering Key operation, locking interlock Moeller HPL0211-2007/2008
http://catalog.moeller.net
http://catalog.moeller.net
For use with
Key withdrawal/locking option
Part no. Article no.
T0-.../E, .../I1, .../Z up to max. 6 contact units T3-.../E, .../Z up to max. 5 contact units T3-.../I2 up to max. 4 contact units P1-.../E, .../I2, .../Z
Key withdrawal positions can be programmed by the user
T0-.../E, .../I1, .../Z up to max. 6 contact units T3-.../E, .../Z up to max. 5 contact units T3-.../I2 up to max. 4 contact units P1-.../E, .../I2, .../Z
Key withdrawal positions are programmed ex-works as ordered
T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z
Key withdrawal positions can be programmed by the user
Moeller HPL0211-2007/2008 Price see price list
7/47
S…, SVA…, SVC…
Std. pack
Notes
S-T0 086709
1 off
S-SOND-KMS(*)-T0 231957
1 off
The key replaces the thumb-grip, cannot be switched without key. The switch position indication in on the lock. Normally the key is withdrawable in every position. With the ordering of a rotary switch with front plate FS908 together with key operation the key is only withdrawable in the 0 position. The key removability can be changed (also retro) with the locking cam "VR-T0". With retrofitting of key operation the existing front plate of the rotary switch must be used. Key a page 7/50
S(*)-T0 231959
1 off
S(*)-SOND-SA(*)-T0 231965
1 off
SVA-T3 050974
1 off
SVA-SOND-KMS(*)-T3 231967
1 off
S-T0 key operated lock mechanism, Front IP53 Includes two keys KMS 1 lock mechanism Individual lock mechanism, not suitable for master key systems KMS 2-10 lock mechanisms, KMS 201-400 lock mechanisms: Individual lock mechanisms, not suitable for master key systems
Lock KMS1: Switch with FS908 are possible as main switch for T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-4-.../I2; T3-1-... to T36-.../E; P1-.../I2, .../E SA(...) = Master key system (with master key) supplied with a security certificate. Order must include a lock plan showing the full configuration of the envisaged lock system. For subsequent part orders, simply state the item number within the lock plan, e.g. (A6294-1/2).
SVA-T3 cylinder lock, Front IP65 Includes two keys KMS 1 lock mechanism Individual lock mechanism, not suitable for master key systems KMS 2-10 lock mechanisms, KMS 201-400 lock mechanisms: Individual lock mechanisms, not suitable for master key systems
KMS1 lock mechanism: Switches with FS908 are suitable as main switches: T0-1-... to T0-4-.../I1, .../E; T3-1-... to T3-5-.../ I2; T3-1-... to T3-6-.../E; P1-.../I2, .../E SA(...) = Master key system (with master key) supplied with a security certificate. Order must include a lock plan showing the full configuration of the envisaged lock system. For subsequent part orders, simply state the item number within the lock plan, e.g. (A6294-1/2).
T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z
Lockable positions can be programmed by the user
SVA(*)-T3 907745
1 off
SVA(*)-SOND-SA(*)-T3 231971
1 off
Switched with thumb-grip. Locked by turning the key. The key is removable. Normally all positions can be locked. Individual positions or ranges are lockable (also retro with VR-T3). In positions that are not lockable the key cannot be removed. With lockable ranges only inside the range can be switched without the key. The positions or ranges to be locked must be entered as follows in the form. Example 1: SVA(A)-T3 = only position A withdrawable Example 2: SVA(A, E)-T3 = only position A and E withdrawable Example 3: SVA(A-J)-T3 = range A to J withdrawable Example 4 SVA(S)-T3 = main switch for use as EmergencyStop according to IEC/EN 60204-1, VDE 0113 Part 1, with red thumb-grip and yellow front plate "Panic lock version" lockable in positions A and E, from E it can still be switched to A but not from A to E.
The front plate of the switch is to be used for retroffitting. With the letter S use for panic lock FS908GE. Ordering example: P1-25/I2-RT+SVA(S)-T3
C
E
D
B
0
330 300
A
F
315
H
30 60
45
270
J
90 225 135
240
210
R Q
G
P
120
150
180
K L
M
N
Ordering example for a master key system: SVA(A-G)-SOND-SA(A6294-1/2)-T3 Key a page 7/50
SVC-T3 padlocking feature, Front IP65 In the depressed position, the locking slide is lockable with up to 3 padlocks All positions are lockable
Specified positions or ranges are lockable
T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z T0-1-... to T0-4-.../I1, .../E T3-1-... to T3-5-.../I2 T3-1-... to T3-6-.../E P1-.../I2, .../E P1-.../I2, .../E
Lockable positions can be programmed by the user
SVC-T3 050975
1 off
Lockable positions are programmed ex- works as ordered
SVC(*)-T3 907748
1 off
Switched with thumb-grip. Interlocked by pushing a button that is lockable with 1-3 padlocks. Normally all positions can be lokked. By entering SCV(...)-T3 only the entered position is lockable. Locked ranges can only be switched within the range without removing the padlocks. The positions or ranges to be locked must be entered in the form. Form a Notes to SVA(...)-T3 The front plate of the switch is to be used for retroffitting. With the letter S use for panic lock FS908GE.
Ordering example: P1-25/I2-RT+SVC(S)-T3
C
E
D
B
0
330 300
A
315
F
45
Q
P
60
J
90 225 135 210
R
H
30
270 240
G
180
N
120
150
K M
L
Rotary switches, switch-disconnectors
Rotary switches, switch-disconnectors
7/46
Rotary switches, switch-disconnectors
7/48
Ordering Neutral poles, auxiliary switches, central mounting accessories N-P1, N-P3, N-P5
Moeller HPL0211-2007/2008
http://catalog.moeller.net
For use with
Part no. Article no.
Price see price list
Std. pack
For side mounting, left or right
P1-.../E, .../EA, .../EZ
5 off
With P1-.../I2: optional N-P1Z or HI11-P1/P3Z can only be fitted to left
P1-.../Z, .../V, .../I2, .../IVS
N-P1E 000651 N-P1Z 000652 N-P3E 062432 N-P3Z 064805
P5-250(315)/Z(V)
N-P5-250/315Z 280972
1 off
P5-125(160)/E(EA)
PE-P5-125/160E 280973 PE-P5-250/315Z 280976
1 off
P1-.../E, .../EA..., .../EZ P3-.../E, .../EA P1-.../Z, .../V, .../I2, .../IVS P3-63/Z, .../V, .../I4, .../IVS P3-100/Z, .../V, .../I5, .../IVS
HI11-P1/P3E 061813 HI11-P1/P3Z 062031
5 off
T0-.../E T3-.../E T0-.../E T3-.../E P1-.../E
EZ-T0 081622 EZ-P1 091455
1 off
T0-.../XZ
IVS-T0 091114
1 off
Neutral poles Early-make, late-break
P3-.../E, .../EA... P3-.../Z, .../V, .../IVS P3-63/E,.../Z, /I4 P3-100/E, .../Z, .../I5 Neutral terminal For side mounting Protective conductor terminal For side mounting
P5-250(315)/Z(V) Auxiliary contacts Late making N/O and early breaking N/C contacts. The N/O is always connected as a load-shedding contact. For side mounting, left and/or right With P1-.../I2: HI11-P1/P3Z or N-P1Z can be fitted to left only Centre mounting accessories For single-hole fitting Mounting diameter 22.3 mm For rotary switches with existing front plate Mounting diameter 22.3 mm and 30.5 mm
1 off
Service distribution board mounting accessories Includes push-fit shaft For retrofitting T0-.../XZ basic switches as T0-.../IVS into service distribution boards
http://catalog.moeller.net
7/49
DE-T0(P3), ZAV-T0(P3)
Moeller HPL0211-2007/2008 For use with
Type suffix/Type Article no., When ordered with basic unit/ ordered separately
Price see price list
Std. pack
Notes
Coupling drive Includes push-fit shaft For retrofitting T0(T3)-.../XZ basic switches in the rear mounting form Spare parts for T0(T3)/(P1)-.../Z
For conversion of T5 (B)-.../E flush mounting switch into a rear mounting switch Spare parts for T5(B)/(P3)-.../Z
DE-T0 093487
1 off
DE-P3 093972
3 off
UV-T0 019925
1 off
Fits on the reverse of flush mounting switches With interlocking function for rear mounting switches
10 off
Use ZVV-T0 only with construction type T0/ T3-.../Z and P1-.../Z
Interlock sections With PE and N conductor connection Fits on the reverse of flush mounting switches, with interlocking function for rear mounting switches. T0-.../E, ...EZ, ...Z T3-.../E, ...EZ, ...Z P1-.../E, ...EZ, ...Z T5(B)-.../E, ...Z P3-.../E, ...Z
UV-P3 048289
Interlock extensions Up to four off, 25 mm each, can be plugged onto interlock section (An equal number of shaft extensions is required for this purpose) Use ZVV-T0 only with T0/T3- UV-T0 .../Z and P1-.../Z
Use ZVV-P3 only with T5(B).../Z and P3-.../Z
ZVV-T0 022298
UV-P3
ZVV-P3 024671
Use ZVV-P3 only with construction type T5(B)-.../Z and P3-.../Z
Shaft extensions Up to four off, 25 mm each, can be plugged onto switch shaft T0-.../Z, T0-.../V T3-.../Z, T3-.../V P1-.../Z, P1-.../V T5(B)-.../Z P3-.../Z
ZAV-T0 027044
10 off
ZAV-P3 029417
Shaft Aluminium, length: 480 mm
P5-.../V... P5-.../Z
ZAV-P5 280979
1 off
+ZAV(X1)+ZVV(X1)-T0/P3 254546
1 off
ST-P5-250/315 280978
1 off
Interlock extensions und shaft extensions, complete Only available in conjunction with a basic unit Extension up to 25 mm
when ordered with basic unit
Control circuit terminal P5-250/315
Terminal capacity • solid or stranded: 4 mm2 • Flexible with ferrules to DIN 46228: 4 mm2
Rotary switches, switch-disconnectors
Ordering Coupling drive, interlock parts, shaft extension
Rotary switches, switch-disconnectors
7/50
Ordering Shrouds, Keys H…
Moeller HPL0211-2007/2008 For use with
Part no. Article no.
For flush-mounting switches with up to 4 contact units
T0-.../E T3-.../E
H3-T0 093828
Cover for protection of terminals For up to 2 contact units
T5(B)-.../E, .../Z
H1-T5 045062
Extension of H1-T5 cover To protect 3 to 8 contact units
H1-T5
To cover terminals on 3-pole switch-disconnectors
Price see price list
http://catalog.moeller.net
Std. pack
Notes
1 off
Cable entries Quantity: 2 x o 20 mm + 2 x o 15 mm Cross-section: 5 x 6 mm2 5 x 2.5 mm2 Can be used for input and/or output wiring
HZ-T5 045063
10 off
1 x HZ-T5 required per contact unit
P1-.../E, .../EZ, .../Z, .../EA, .../V
H-P1 017253
5 off
Can be used for input and/or output wiring
To cover terminals on 4-pole switch-disconnectors
P1-...N, ...HI11, ...N...HI11
H-P14 019626
Can be used for input and/or output wiring
To cover terminals on 3-pole open switch-disconnectors with N neutral conductor and/or HI11 auxiliary contact modules fitted
P3-.../E, .../Z, .../ EA, .../V P3-...N, ...HI11, ...N...HI11
H-P3 021999
The shroud is designed for fitting onto both sides of the switch-disconnector. Parts which are not required can be broken off.
Set of three, to protect the terminals
P5
H-P5-125/160-3P 280967
Cover assembly to protect the 6 terminals
T8-3-8342/...
H-T8 200184
Shrouds
3 off
Keys For KMS 1 individual lock mechanism For KMS 2 - 10 individual lock mechanism or KMS 201 - 400 Individual key, corrosion-proof, for master key systems and recorded individual lock mechanisms: state lock plan no. and lock
ES-KMS1-T0 231972 ES-KMS(*)-T0 231973 HS-SA(*)-T0 256151
10 off
Master keys must always be ordered separately. Please send or submit the security certificate with repeat orders. Ordering example:HSSA(A6294-1/2)-T0
Locking cams (2 cams per set) For user to select indexing position in which key can be withdrawn
S-T0 for all switching angles
VR-T0 089082
1 off
To connect the screeniing
CI-K2
MBS-I2 290191
2 off
Mounting plate screen
http://catalog.moeller.net
7/51
Moeller HPL0211-2007/2008 For use with
Part no. Article no.
T0-.../XZ
Price see price list
Std. pack
Notes
CI-K1-T0-2 207435 CI-K1-T0-4 207436 CI-K2-T3-2 207437 CI-K2-T3-5 207438 CI-K2-T3-4 225325
1 off
Cable sizes which may be pushed through the diaphragm Main-/control current 12 mm/– 16 mm/8 mm 1 contact unit = 2 contacts
CI-K1H-T0-2 105854 CI-K1H-T0-4 105855 CI-K2H-T3-2 269462 CI-K2H-T3-4 105859 CI-K2H-T3-5 105860 CI-K4-T5B-2 207439 CI-K4-T5B-4 207440 CI-K5-T5-2 207441 CI-K5-T5-4 207442
1 off
IP65 insulated enclosures Enclosures designed for metric cable glands to EN 50262 1 – 2 contact units With pushthrough cable entry 3 - 4 contact units diaphragm.
T0-.../XZ
1 – 2 contact units
T3-.../XZ
5 contact units
T3-.../Z
3 - 4 contact units
T3-.../XZ
1 – 2 contact units
With metric knock-outs
T0-.../XZ
1 off 1 off 1 off 1 off
3 - 4 contact units
T0-.../XZ
1 – 2 contact units
T3-.../XZ
3 - 4 contact units
T3-.../XZ
5 contact units
T3-.../XZ
1 – 2 contact units
T5B-.../E
3 - 4 contact units
T5B-.../Z
1 – 2 contact units
T5-.../Z
3 - 4 contact units
T5-.../Z
only available together with basic device
T0-.../I1
+I1H 105870
1 off
only available together with basic device
T3-.../I2 P1-.../I2
+I2H 105871
1 off
CI-K2-PKZ0-...
K-CI-K1/2 207451 K-CI-K4 206916
20 off
K50/1 098573
10 off
K-CI-K5 218488
20 off
T5B-.../I4, T5-.../I5, P3-63/I4, P3-100/I5,
AB-CI-K4/5 206914
1 off
For fixing CI-K4 and CI-K5 directly to the wall. One set comprises 4 brackets.
T5B-.../I4 T5-.../I5 T5-.../I5
AW-T5-1/2 032601 AW-T5-3/4 032602
10 off
Included with T5B-.../I4 and T5-.../I5 as standard. Included with T5B-.../I4 and T5-.../I5 as standard.
1 off 1 off 1 off 1 off 1 off 1 off 1 off
Converts T5-.../Z into T5-.../I5 and T5B-.../E into T5B.../I4: Order AW-T5-... extension terminals in addition 1 contact unit = 2 contacts
1 off
Neutral terminals For connection of 5th conductor
T5B-.../I4, Cl-K4-T5B-... P3-.../I4 CI-K4 T5-…/I5, CI-K5-T5-… P3-…/I5 CI-K, 100 A T5-.../I5, CI-K5-T5-... P3-.../I5 CI-K5
20 off
Set of external fixing brackets
Set of extension terminals For retrofitting For cable connection in the enclosure For the lowest contact unit For the second contact unit from the bottom
1 off
Rotary switches, switch-disconnectors
Ordering Insulated enclosures, accessories
Rotary switches, switch-disconnectors
7/52
System overview Mini rotary switches TM
Moeller HPL0211-2007/2008
http://catalog.moeller.net
ON-OFF switches TM
1
2 10
9 9
8 7 8
5
8 6
8
8
6
4
6
3
4 4
8 Control switch TM
1
2 10 11 9 11
9
O
HA
ND
5
AU TO
0
6 6
3
6 4 4 4
1
http://catalog.moeller.net
TM
Moeller HPL0211-2007/2008
Flush mounting (.../E) Front IP 65 Mounting from rear in walls, plates or doors Terminals: Crosshead screwdriver Pozidrive Fingerproof
1
a page 7/54 Flush mounting control circuit isola- 1 tor (.../E/SVB) Front IP 65 To IEC/EN 60947-5, VDE 0660 0 position lockable with 2 padlocks 4 mm o or 1 padlock 6 mm o
Centre mounting (.../EZ)
2
Front IP 65 Mount in fixing hole 16.2 o or 22.3 o according to IEC/EN 60947-5-1 after removing provided the adapter
Control circuit isolator
7, 8
Red rotary handle and yellow locking collar 3, 4
Black rotary handle and black locking collar
2 keys are supplied Key withdrawable 90°
Lockable in the 0 position a page 7/54
Key withdrawable 60° with RONIS lock cylinder.
Standard switch for flush mounting
a page 7/59
Black thumb-grip a page 7/55
Can be used with up to 250 V AC per contact Maximum 6 contacts permissible a page 7/54
9, 10
Standard switch for distribution 11 board mounting IVS Mounting in service distribution board Mounting width: 2 TE (45 mm mounting depth) up to 2 contact units
Product features Contact chamber • Rated uninterrupted current 10 A • Gold plated contacts for safe switching of small voltages and currents also in agressive atmospheres • -Positively opening contacts • 1 – 2 contacts per switching chamber (BE), up to 16 contacts per switch • For switching differing potentials • Control circuit reliability
Standard switch for centre mounting 5, 6 Black thumb-grip a page 7/54
a page 7/54 Key operation for centre mounting
7/53
Switch postion • Safety due to latching • Switching angle 30°, 45°, 60°, 90° • Spring action with automatic return with max. 6 contacts, switching angle f 60° • Complete rotation • With a total switching angle of 360° complete rotation is possible in both directions
Rotary switches, switch-disconnectors
System overview Mini rotary switches
7/54
Ordering Control circuit isolators, On-Off switches TM Front plate no.
No. of poles
Design
Protection type
Part no. Article no.
Flush mounting
Front IP65
Flush mounting
Front IP65
TM-1-8290/E/SVB-SW 215351 TM-1-8290/E/SVB 045477
Flush mounting
Front IP65
Flush mounting
Front IP65
Flush mounting
Front IP65
Flush mounting
Front IP65
3+N
Flush mounting
Front IP65
TM-2-8293/E/SVB 045485
6
Flush mounting
Front IP65
TM-3-8326/E/SVB 045498
1
Centre mounting
Front IP65
TM-1-8290/EZ 000693
Flush mounting
Front IP65
TM-1-8290/E 070131
Centre mounting
Front IP65
TM-1-8291/EZ 015073
Flush mounting
Front IP65
TM-1-8291/E 072504
Flush mounting
Front IP65
Centre mounting
Front IP65
TM-2-8292/E 074877 TM-2-8292/EZ 015096
Flush mounting
Front IP65
TM-2-8293/E 077250
Centre mounting
Front IP65
TM-2-8293/EZ 045486
Flush mounting
Front IP65
TM-3-8326/E 079623
Price see price list
http://catalog.moeller.net Std. pack
Control circuit isolators, 90°
1 2
0 1
With padlocking facility, lockable in the Off position Up to 250 V AC per contact 1
1 2 3 4
0 1
2
1 off
TM-1-8291/E/SVB-SW 215352 TM-1-8291/E/SVB 045478 TM-2-8292/E/SVB 045484 TM-2-8292/E/SVB-SW 210955
1 2 3 4 5 6 7 8 9 10 11 12
0 1
1 2 3 4 5 6 7 8
0 1
1 2 3 4 5 6
0 1
3
On-Off switches, 90° 0 1
1
1 2
0
F 056
1 2 3 4
0 1
2
1 2 3 4 5 6
0 1
3
1 2 3 4 5 6 7 8
0 1
3+N
0 1
6 1 2 3 4 5 6 7 8 9 10 11 12
Mini rotary switches
Contact sequence
Moeller HPL0211-2007/2008
1 off
Ordering Changeover switch, hand/automatic switch http://catalog.moeller.net
TM
Moeller HPL0211-2007/2008
Contact sequence
Front plate no.
7/55
No. of poles
Design
Protection type
Part no. Article no.
1
Centre mounting
Front IP65
1
Flush mounting
Front IP65
2
Centre mounting
Front IP65
2
Flush mounting
Front IP65
3
Centre mounting
Front IP65
3
Flush mounting
Front IP65
4
Centre mounting
Front IP65
4
Flush mounting
Front IP65
5
Centre mounting
Front IP65
5
Flush mounting
Front IP65
6
Flush mounting
Front IP65
TM-1-8220/EZ 000692 TM-1-8220/E 081996 TM-2-8221/EZ 015197 TM-2-8221/E 084369 TM-3-8222/EZ 045493 TM-3-8222/E 086742 TM-4-8223/EZ 046119 TM-4-8223/E 089115 TM-5-8369/EZ 046126 TM-5-8369/E 091488 TM-6-8370/E 093861
1
Centre mounting
Front IP65
1
Flush mounting
Front IP65
2
Centre mounting
Front IP65
2
Flush mounting
Front IP65
3
Centre mounting
Front IP65
3
Flush mounting
Front IP65
3
Flush mounting
Front IP65
4
Centre mounting
Front IP65
4
Flush mounting
Front IP65
With 0 position, 90°
2
Flush mounting
Front IP65
TM-2-8219/E 017926
With springreturn from both directions, 30°
1
Flush mounting
Front IP65
TM-1-8214/E 032164
2
Flush mounting
Front IP65
TM-2-8215/E 034537
1
Centre mounting
Front IP65
TM-18220F288/EZ 016925
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
1
Service distribution board mounting
Front IP30
TM-1-15431/E 025045 TM-1-15431/EZ 000691 TM-1-15431/IVS 225342
2
Centre mounting
Front IP65
2
Flush mounting
Front IP65
3
Centre mounting
Front IP65
3
Flush mounting
Front IP65
Price see price list
Std. pack
Changeover switches
F 072
1 2 3 4 5 6 7 8
1 2 1 2 3 4 5 6 7 8 9 10 11 12
1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 0 2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2
1 off
Mini rotary switches
Without 0 position, 60°
2
1 2
1 2 3 4
1 2
1
0
2
With 0 position, 60°
F 071
1 0 2
1 2 3 4 5 6 7 8
1 0 2
1 2 3 4
1
0
2
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 0 2
1 2 3 4 5 6 7 8 9 10 11 12
F 249
1 0 2
0
2
1 2 3 4 5 6 7 8
1
2
F 057
1
0
1 0 2
F 025
1 2 3 4 5 6 7 8
1
0
2
1 2 3 4
TM-1-8210/EZ 015137 TM-1-8210/E 096234 TM-2-8211/EZ 015166 TM-2-8211/E 098607 TM-3-8212/EZ 045491 TM-3-8212/E 010807 TM-3-8299/E 020299 TM-4-8213/EZ 045847 TM-4-8213/E 013180
Hand-Auto switches, 60° AUTO HAND
1 2 3 4
HAND AUTOM
AUTO 0 HAND
F 288 HAND
0
1 2 3 4
F 085
AUTO
1 2 3 4 5 6 7 8
AUTO 0 HAND
1 2 3 4 5 6 7 8 9 10 11 12
AUTO 0 HAND
TM-2-15432/EZ 016878 TM-2-15432/E 027418 TM-3-15433/EZ 045490 TM-3-15433/E 029791
1 off
7/56
Ordering Control switch, step switch TM Front plate no.
No. of poles
Design
Protection type
Part no. Article no.
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
3
Flush mounting
Front IP65
3
Centre mounting
Front IP65
TM-2-8230/E 039283 TM-2-8230/EZ 000701 TM-5-8270/E 041656 TM-5-8270/EZ 046124
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
3
Flush mounting
Front IP65
3
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
2
Flush mounting
Front IP65
2
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
2
Flush mounting
Front IP65
2
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
http://catalog.moeller.net Price see price list
Std. pack
Step switches
1 2 3
Without 0 (Off) position 3 steps, 60° 2
3
F 076
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1 2 3
1 2 3 4 5 6
1
1 2 3 4
4 steps, 60° 2
3
1
4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4
1 2 3 4 5 6 7 8
F 077
TM-2-8231/E 044029 TM-2-8231/EZ 000700 TM-6-8271/E 046402 TM-6-8271/EZ 046128
1 2 3 4 5
5 steps, 60° 2
3
1
4 5
TM-3-8232/E 039298 TM-3-8232/EZ 015592
1 2 3 4 5 6 7 8 910
F 078
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
TM-5-8252/E 041671 TM-5-8252/EZ 046123
1 2 3 4 5 6
6 steps 60°, no full rotation 2
3
1
4 6
5
TM-3-8233/E 053521 TM-3-8233/EZ 015630
1 2 3 4 5 6 7 8 9 10 11 12
F 079
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
TM-6-8253/E 055894 TM-6-8253/EZ 046127
10 steps, 30° 2 1
345
6 7 8 10 9
F 011
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Mini rotary switches
Contact sequence
Moeller HPL0211-2007/2008
TM-5-8237/E 069150 TM-5-8237/EZ 015661
1 off
Ordering Control switch, step switch TM
Moeller HPL0211-2007/2008
Contact sequence
Front plate no.
Price see price list
Std. pack
No. of poles
Design
Protection type
Part no. Article no.
1
Flush mounting
Front IP65
1 off
1
Centre mounting
Front IP65
2
Flush mounting
Front IP65
2
Centre mounting
Front IP65
3
Flush mounting
Front IP65
3
Centre mounting
Front IP65
TM-1-8240/E 058267 TM-1-8240/EZ 015226 TM-2-8260/E 060640 TM-2-8260/EZ 045483 TM-3-8280/E 063013 TM-3-8280/EZ 045496
1
Flush mounting
Front IP65
1 off
1
Centre mounting
Front IP65
TM-2-8241/E 065386 TM-2-8241/EZ 015256
2
Flush mounting
Front IP65
2
Centre mounting
Front IP65
3
Flush mounting
Front IP65
3
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
2
Flush mounting
Front IP65
2
Centre mounting
Front IP65
3
Flush mounting
Front IP65
3
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
1
Flush mounting
Front IP65
1
Centre mounting
Front IP65
Step switches
0 1 2
With additional 0 (Off) position 2 steps, 60° 2
1 0
1 2 3 4 5 6 7 8 9 10 11 12
0 1 2
1 2 3 4 5 6 7 8
0 1 2
1 2 3 4
F 075
0 1 2 3
3 steps, 45° 1 2 3 0
TM-3-8261/E 067759 TM-3-8261/EZ 000698 TM-5-8281/E 070132 TM-5-8281/EZ 046125
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
0 1 2 3
1 2 3 4 5 6 7 8 9 10 11 12
0 1 2 3
1 2 3 4 5 6
F 109
0 1 2 3 4
4 steps, 30° 1 0
234
1 off
TM-4-8262/E 074878 TM-4-8262/EZ 046120 TM-6-8282/E 077251 TM-6-8282/EZ 046129
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
0 1 2 3 4
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
0 1 2 3 4
1 2 3 4 5 6 7 8
F 002
TM-2-8242/E 072505 TM-2-8242/EZ 015506
0 1 2 3 4 5
5 steps, 30° 1 0
2 34
5
1 off
TM-3-8244/E 081997 TM-3-8244/EZ 045495
1 off
TM-5-8247/E 009741 TM-5-8247/EZ 015565
1 off
1 2 3 4 5 6 7 8 9 10
F 003
TM-3-8243/E 079624 TM-3-8243/EZ 015537
0 1 2 3 4 5 6
6 steps, 30° 1 0
2 34
5 6
1 2 3 4 5 6 7 8 9 10 11 12
F 004
9 steps, 30° 1 0
2 3 4 98
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
F 007
5 6 7
Mini rotary switches
http://catalog.moeller.net
7/57
7/58
Ordering Control switches: group switches (OFF) spring-return switch, reversing switches, coding switches TM Front plate no.
http://catalog.moeller.net
Design
Protection type
Part no. Article no.
Price see price list
Std. pack
Flush mounting
Front IP65
Centre mounting
Front IP65
TM-1-8310/E 084370 TM-1-8310/EZ 045479
Centre mounting
Front IP65
TM-2-8311/EZ 045487
Centre mounting
Front IP65
TM-1-8175/EZ 015690
Flush mounting
Front IP65
Centre mounting
Front IP65
TM-1-8178/E 098608 TM-1-8178/EZ 016786
Flush mounting
Front IP65
TM-3-8401/E 015554
1 off
Flush mounting
Front IP65
1 off
Centre mounting
Front IP65
TM-2-8550/E 020300 TM-2-8550/EZ 000699
Flush mounting
Front IP65
Group switches 2 groups, 60° 2 1 0
2
1
1 2 3 4
0
F 075
1 off
3
3 groups, 30° 2 3
1
2
1 0
1 2 3 4 5 6
0
F 001
ON (OFF) switch On switch 30° START I
1 off
1 2
START
F 023
ON-OFF switch 90°/30° with spring-return from Start to 1 START 1 0
1 START 0
1 2 3 4
F 119
Reversing switches 60 Degree 0
2
0
2
1
1 2 3 4 5 6 7 8 9 10
1
F 071
Coding switches BCD code 0-9, 30° 1 0
2 3 4 98
5 6 7
2 3 4 5 6 7 8
F 007
BCD code 0-9 + complement, 30° 1 0
2 3 4 98
F 007
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Mini rotary switches
Contact sequence
Moeller HPL0211-2007/2008
5 6 7
TM-4-8552/E 025046
Ordering Locks, front plates Protection type
EZ/S-…
Moeller HPL0211-2007/2008 Key withdrawable with
Part no. suffix Article no.
Price see price list
Std. pack
Notes
1 off
Key operated lock mechanism including two keys. The key can be withdrawn only in specified positions, see diagrams below. However, the KABA lock mechanism for 90 can also be used for other switching angles provided the positions for key withdrawal correspond with those specified for the Type of switch. Example: +EZ/S-B can be used on a step switch having a switching angle of 30°, provided the key is to be withdrawn only in the Off position at 270°.
Key operation Includes two keys For service distribution board mounting (IVS) when ordered with basic unit KABA lock 90°
RONIS lock 60°
IP65
0°
IP65
270 + 0°
IP65
270°
IP55
270 + 330 + 30 + 90 + 150 + 210° 270 + 90°
IP55 IP55 IP55
270 + 330 + 90 + 150° 300 + 0 + 60 + 120 + 180 + 240°
+EZ/S-A 045458 +EZ/S-F 045463 +EZ/S-B 045459 +EZ/S-J 045466 +EZ/S-D 045461 +EZ/S-N 045468 +EZ/S-H 045465
Options for key withdrawal
A
B
C
D
E
F
G
H
J
M
N
P
Q
R
Postion marking for the example 0
330
30
300 315
90 135 120
270 240 225 210
Size
Dimensions (W x H x D) mm
Standard front plates TM.../EZ 29 x 29 (for frame size 30 x 30) TM.../E 29 x 29 (for frame size 30 x 30)
150
180
Part no. Article no.
Std. pack
Notes
TM/EZ-FRONTSCHILD-NR(*) 239022 TM/E-FRONTSCHILD-NR(*) 239021
1 off
Standard front plates For standard contact sequence the normal front plate can be replaced if required with the front plate shown here. This is provided the switching angle, number of positions and the position of the 0 position are the same.
1 off
Switching angle 30°
Blank plates Can be engraved TM 29 x 29 (for frame size 30 x 30) TM 29 x 29 (for frame size 30 x 30)
60
45
FS980-TM-E 071438 FS980-TM-EZ 073811
10 off 50 off
START
F023 1 0
1 0
F001
MAN
234
1 0
234
5
F003
F002
OFF
AUTO
F039
F025
F024
23
1 0 2
START
STOP
1 0
1 0
2
AUTO
F053
234
5 6
F004
1 0
0
HAND
F258
234
5 6 7
F005
1 0
AUTO
0
MAN
5 6 7
8
1 0
234
5 6 7
98
HAND
2 1
345 10 9
6 7 8
F011
F007
F006
OFF
F708
F259
234
AUTO
Switching angle 45 0
1
2
F215 1 0
2
1
0
2
F293
2 1
3
2
3
4 5
2
1
0
1 2 3
3
F106
F741
1 0
2
3
1
2
2
3 7
F110
4
2 1
L1-N
L1-L2
L2-L3
L2-N
L2-L3
L2-L3
L3-L1
L3-N
L3-L1
L3-L1
F115
4 5 6
3
3
1 OFF
F109
F738
F216
3 4
1
L1-L2
0
F330
F785
0
0
1 2
1 2
1
3
2 8
4 5 6
7
1 2
0
1 7
2
3 4
5
6
F322
F111
F788
OFF
F113
F105
L1-L2
1 2
Switching angle 60° 2
1
F072 2
0
MAN
AUTO
MAN
0
AUTO
AUTO
OFF
0
1
2
F071
F288
F234 1
HAND
AUTO
HAND
1
2
F073
3
2
1
0
4
0
1
4
F732
F373
F077
F102
2
3
6
5
1
5
F249
HAND
4
F079
F078
0
AUTO
F085
F076
3
2 3
3
2 1
F075
2
1
2
1 0
1
0
START
2
START
F121
Switching angle 90° 1
ON
0
EIN
OFF
F056 3
F059
0
1 1
2
4
2 3
F060
F700
F068
F063
0
1
0
2
1
AUS
1
F062
ON
ON OFF
F206
1
3
2
OFF
2
MAN
AUTO
F057
F209
0
1
2
OFF
1 0
F743
0 1
NETZ
NOTSTROM
0
1
F719
START
4
F718
F437
F119
F990
3
Mini rotary switches
http://catalog.moeller.net
7/59
7/60
System overview Small enclosures
Small enclosures, empty enclosures
CI-K
Moeller HPL0211-2007/2008
1
2
1 1
3
1
3 3
http://catalog.moeller.net
General Degree of protection IP65 (except CI-K2-80-A) Five basic sizes (floor area of enclosure base) Two mounting depths per base surface (exception: CI-K1 enclosure depth always 95 mm, CI-K2-80-. enclosure depth always 80 mm) Enclosure made of glass-fibre reinforced with self-extinguishing polycarbonate, halogen free Captive gasket Enclosure base (RAL 9005) Black (matt) Enclosure cover RAL 7035, light grey (matt) Metric cable entries 1 CI-K1 and CI-K2 metric cable entry knockouts with push-through cable entry diaphragm in the sides, top and bottom and also in the rear wall CI-K1H, CI-K2H: metric cable entry knockouts in the enclosure sides, top and bottom CI-K3 to CI-K5: metric cable entry knockouts in the sides, top and bottom and also in the rear wall Control cable entry from CI-K2 Metric cable glands to EN 50 262 Push-through metric cable grommets a page 7/63, a page 13/35 Mounting systems for empty enclosures 2 Mounting rails to IEC/EN 60715 Sheet steel mounting plates Accessories for mounting systems a page 7/64 Mounting 3 Horizontal and vertical slot apertures for wall-mounting enclosures Captive cover screws CI-K1 and CI-K2 with rubber feet on the back plate to compensate for uneven walls External mounting brackets for CI-K4 and CI-K5 a page 7/51 Mounting units Miniature circuit-breakers Rotary switch Switch-disconnectors Contactors easy control relays Timing relays Control circuit devices • Laser labelling We can label the cover surface of the CI-K small enclosures according to your specifications. Wipe-resistant and permanent with modern laser labelling method. Please contact your sales office. CI-K combination-* a page 7/62 Approved enclosures for use in UL/CSA a page A1/40 • Cutouts in enclosure covers We can produce cutouts in enclosure covers to your requirements. Please contact your sales office.
Ordering Basic enclosures CI-K1, CI-K2, CI-K3
Moeller HPL0211-2007/2008
Dimensions
Enclosure depth: Dimensions from top 1. Mounting depth for mounting plate 2. Mounting depth for mounting rails, 7.5 mm height 3. Enclosure depth
mm
mm
Features
Part no. Article no.
Price see price list
Std. pack
CI-K basic enclosures • • • • • • • • •
Degree of protection IP65 (Exception: CI-K2-80-A), material glass-fibre reinforced polycarbonate Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey Metric cable entry knockouts top, bottom and in the back plate Push-through cable membrane on CI-K1 and CI-K2 Hard metric knockouts for sizes CI-K1H and CI-K2H Hard metric knockouts from sizes CI-K3 to CI-K5 Two protective covers to protect the push-through cable membrane with CI-K1 and CI-K2 Control cable entry from CI-K2 Lamp indicator L-. can be mounted in base knock-out M20/M25 With mounting rail L 72
With mounting rail
82 120
S
L 80
CI-K1-95-TS 206881 CI-K1H-95-TS 105853
95
With mounting rail
M
116 160
79
T
With adapter plate Prepared for fitting a DILE contactor with ZE overload relay
CI-K2-100-TS 206882 CI-K2H-100-TS 229304 CI-K2-100-M 206893 CI-K2H-100-M 229306 CI-K2-145-TS 206883 CI-K2H-145-TS 229305 CI-K2-145-M 206894 CI-K2H-145-M 229307 CI-K2-145-AD 207632
With adapter plate Prepared for fitting a DILE contactor with ZE overload relay
CI-K2H-145-AD 229308
With mounting rail
CI-K3-125-TS 206884 CI-K3-125-M 206895
With mounting rail
73
With mounting plate Q
With mounting plate
100
100
With mounting rail
M
116 160
124
T
118
With mounting rail With mounting plate
Q 100
145
N
152 200
98
U
With mounting plate
With mounting plate
93
R 120
125
With mounting rail
N
U
152 200
133 128
R 120
Notes
160
Number and size of cable entries a page 7/63
With mounting plate
CI-K3-160-TS 206885 CI-K3-160-M 206896
1 off
Small enclosures, empty enclosures
http://catalog.moeller.net
7/61
7/62
Ordering Basic enclosures Moeller HPL0211-2007/2008
Dimensions
Enclosure depth: Dimensions from top 1. Mounting depth for mounting plate 2. Mounting depth for mounting rails, 7.5 mm height 3. 7.5 mm mounting depth with mounting rails
mm
mm
Features
Part no. Article no.
http://catalog.moeller.net Price see price list
Std. pack
CI-K basic enclosures • • • • • • • • •
Degree of protection IP65 (Exception: CI-K2-80-A), material glass-fibre reinforced polycarbonate Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey Metric cable entry knockouts top, bottom and in the back plate Push-through cable membrane on CI-K1 and CI-K2 Hard metric knockouts for sizes CI-K1H and CI-K2H Hard metric knockouts from sizes CI-K3 to CI-K5 Two protective covers to protect the push-through cable membrane with CI-K1 and CI-K2 Control cable entry from CI-K2 Lamp indicator L-. can be mounted in base knock-out M20/M25 With mounting rail O
194 240
98
V
With mounting plate
CI-K4-125-TS 206886 CI-K4-125-M 206897
1 off
93
O 160
125
With mounting rail 133
With mounting plate
CI-K4-160-TS 206890 CI-K4-160-M 206898
128
160
P
98
W
234 280
Small enclosures, empty enclosures
CI-K4, CI-K5
93
With mounting rail (weight of fitted components max. 0.65 kg, with additional mounting plate 1.7 kg) With mounting plate
CI-K5-125-TS 206891
With mounting rail (component weight max. 0.65 kg, with additional mounting plate 1.7 kg)
CI-K5-160-TS 206892
With mounting plate
CI-K5-160-M 206900
CI-K5-125-M 206899
P 200
125
133 128
160
Customized cutouts and laser inscriptions • Only with enclosure cover • The necessary data (laser data, symbols, text and their respective positions) as well as the position of the cutouts must be provided as a DXF file. CI-K1-COMBINATION-* 102060 CI-K2-COMBINATION-* 102061 CI-K3-COMBINATION-* 102062 CI-K4-COMBINATION-* 102063 CI-K5-COMBINATION-* 102064 Notes
Number and size of cable entries a page 7/63
1 off
Ordering Basic enclosures CI-K2
Moeller HPL0211-2007/2008
Dimensions
Enclosure depth: Dimensions from top 1. Enclosure depth 2. Mounting depth for mounting plate 3. Mounting depth for mounting rail, 7.5 mm height
mm
mm
Features
Part no. Article no.
Price see price list
Std. pack
Basic enclosure CI-K2 Degree of protection IP30, glass-fibre reinforced polycarbonate material Enclosure base RAL 9005, black/enclosure top RAL 7035, light grey Metric cable entry knockouts top, bottom and in the back plate Push-through cable entry diaphragm with CI-K2 Hard metric knockouts on CI-K2H Two protective covers to protect the push-through cable membrane with CI-K2 Control cable entry L-... indicator lights can be fitted in M20/M25 knockout in base with cover cutout Standard cutout dimensions and mounting M rail for devices requiring 2 to 4 space units. T Push-through cable entry membrane. 46 Close off unused space units (max. 2) using blanking strips VST1, a page 7/65
CI-K2-80-A 211107
1 off
160
• • • • • • • •
Q
80
100
M
with hinged cover
Standard cutout dimensions and mounting rail for devices requiring 2 to 4 space units. Hard metric knockouts. Close off unused space units (max. 2) using blanking strips VST1, a page 7/65
CI-K2H-80-A 229309
1 off
with cover cutout
Transparent hinged cover for devices requiring 2 to 4 space units. Push-through cable entry diaphragm.
CI-K2-80-K 211108
1 off
with hinged cover
Transparent hinged cover for devices requiring 2 to 4 space units. Hard metric cable entry knockouts.
CI-K2H-80-K 229310
1 off
T 160
70
Q 80
100
115
Notes
Membrane grommets, cable glands a page 13/35
L
M
Knockouts 2 x M20 or pushthrough membrane up to max. o 12 mm
N
O
P
Q
Knockouts Knockouts 2 X M25/20 2 x M25 or pushthrough membrane up to max. o 16 mm CI-K2H: 2 x M25/20
Knockouts 2 X M32/25 1 X M20
Knockouts 2 X M50/40/25 1 X M20
Knockouts Knockouts 2 X M25/20 2 x M25 or pushthrough membrane up 1 X M20 to max. o 16 mm and 1 push-through membrane up to o 8 mm CI-K2H: 2 x M25/20
S
T
V
W
Back plate: 2 x push-through membrane up to max. o 8 mm
Back plate: Back plate: 2 x push-through mem- 2 X M25/20 brane up to max. o 11 mm (not for CI-K2H)
Back plate: 2 X M32/25
Back plate: 2 X M50/40/25
U
R
Small enclosures, empty enclosures
http://catalog.moeller.net
7/63
7/64
Ordering Accessories For use with
Moeller HPL0211-2007/2008 Mounting position
Features
Useful length
Part no. Article no.
http://catalog.moeller.net Price see price list
Std. pack
mm Mounting rails to IEC/EN 60715 Height 7.5 mm, with fixing screws
7.5
CI-K1
Crosswise
60
CI-K2
Crosswise
82
CI-K3
Lengthwise and crosswise
98
CI-K4
Crosswise
133
CI-K5
Lengthwise and crosswise, CI-K4 lengthwise
173
TS-CI-K1 206901 TS-CI-K2 206902 TS-CI-K3 206903 TS-CI-K4 206904 TS-CI-K5 206905
10 off
M-CI-K2 206906 M-CI-K3 206907 M-CI-K4 206908 M-CI-K5 206909
10 off
HS25-CI 002291 HS50-CI 002292 ADT200-190 002289 ADT125-110 002290
25 off
BT7488 088380 BT7477 086007
100 off
Mounting plates 2 mm steel with fixing screws
CI-K2
–
CI-K3
–
CI-K4
–
CI-K5
–
Accessories for mounting systems Spacers For raising mounting systems in CI-K3 to CI-K5 (4 off required for mounting plate, 2 off required for mounting rail) –
by 25 mm
–
–
by 50 mm
–
–
by 10 mm
–
–
by 15 mm
–
–
M4 thread
–
–
M5 thread
–
25 off 10 off 10 off
Hank nuts To secure devices to mounting plate 7
Small enclosures, empty enclosures
TS-CI, M-CI
100 off
http://catalog.moeller.net
K-CI, SK-CI
Moeller HPL0211-2007/2008 For use with
For use with
7/65
Terminal capacities flexible mm2
Accessories for CI-K small enclosures External fixing bracket kit To secure CI-K4 and CI-K5 directly on the wall. Each kit contains 4 brackets. – T5B-.../I4, T5-.../I5, P3-63/I4, P3-100/I5,
Part no. Article no.
Price see price list
Std. pack
AB-CI-K4/5 206914
1 off
TB-CI-K 206918
1 off
VST1 211258
5 off
1 – 4 mm2
K-CI-K1/2 207451
20 off
CI-K3
1 – 10 mm2
20 off
CI-K4
1.5 – 16 mm2
K-CI-K3 206915 K-CI-K4 206916 K-CI-K5 218488
20 off
SK-CI-K1 226766 SK-CI-K2 226767
100 off
Mounting rail adapter, screw fixing To secure enclosure on mounting rails to IEC/EN 60715 CI-K1
Blanking strips To blank off one space unit; cannot be removed from outside CI-K2-80-A
N terminals, PE terminals Can be screwed onto support bosses in enclosure base plate CI-K2-PKZ0-... CI K1/2
Insulated individual terminals • With PE, N adhesive labels • For snap-fitting onto mounting rail
T5B-.../I4, Cl-K4-T5B-... P3-.../I4 CI-K5 T5-.../I5, CI-K5-T5-... P3-.../I5 Protective covers for push-through cable membrane with CI-K1(2) To cover the push-through cable membrane CI-K1 (M20) CI-K1 (M25)
10 – 35 mm2
20 off
100 off
Rotary switches, switch-disconnectors
Ordering Accessories
7/66
Ordering Accessories Moeller HPL0211-2007/2008
Dimensions
Features
For use with
mm
Enclosure depth
Part no. Article no.
mm
Price see price list
http://catalog.moeller.net Std. pack
CI-B, C, D basic enclosures Transparent cover Metric knockouts top, bottom With PEN terminal IP55 individual enclosure with pre-drilled mounting plate DIL00AM L
CI-B 024315
5 off
L
110
149
• • • •
L
Knockouts 2 X M20
128
87
S27
L
CI-C 031434
2 off
CI-D 038553
2 off
–
BT7488 088380
100 off
–
BT7477 086007
100 off
CI-B CI-C CI-D
K6/1 002270
100 off
165
110
L
128
110
DIL0AM S27
L
222
110
L
128
110
Hank nuts To secure devices to mounting plate M4 thread 7
Small enclosures, empty enclosures
CI
M5 thread PE terminal (5th conductor) Rated current 25 A For o 1.5 – 6 mm2 solid
http://catalog.moeller.net
P1, P3
Moeller HPL0211-2007/2008 P1-25
General Standards Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Mounting position Mechanical shock resistance (IEC/EN 60068-2-27) Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current Load rating with intermittent operation, class 12
Operations Operations/h
°C °C
Half-sinusoidal shock, 20 ms
g
Ue Uimp
V AC V AC
Iu
Icw
Terminal screw Tightening torque Switching capacity Alternating voltage Rated making capacity cos v = 0.35 Rated breaking capacity, motor load switch cos v = 0.35
230 V 400/415 V 500 V 690 V Rated operational current 440 V load-break switch AC-21A AC-3 motor load switch motor rating 230 V 400/415 V 500 V 690 V AC-23A Motor load switches (main 230 V switches maintenance switches) 400/415 V 500 V 690 V DC DC-1, Load-break switches L/R = 1 ms Rated operational current Voltage per contact pair in series DC-23A, motor load switch 24 V Rated operational current L/R = 15 ms Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts
Ie P P P P P P P P Ie Ie Ie Ie Ie
P1-32
P3-63
P3-100
IEC/EN 60 947, VDE 0660, IEC/EN 60 204, CSA,UL Switchdisconnectors to IEC/EN 60 947-3 0.3 0.3 0.1 0.1 50 50 50 50 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 -25…50 -25…50 -25…50 -25…50 -25…40 -25…40 -25…40 -25…40 As required As required As required As required 15 15 15 15
A x Ie x Ie x Ie A gG/gL Arms V AC
690 6000 III/3 25 1.3 1.6 2 25 640 690
690 6000 III/3 32 1.3 1.6 2 50 640 690
690 6000 III/3 63 1.3 1.6 2 80 1260 690
690 6000 III/3 100 1.3 1.6 2 100 2000 690
V AC
440
440
440
440
° Number W
90 max. 3 (+N) 1.1
90 max. 3 (+N) 1.8
90 max. 3 (+N) 4.5
90 max. 3 (+N) 7.5
mm2
Nm
1 x (1.5 – 6) 2 x (1.5 – 6) 1 x (1 – 4) 2 x (1 – 4) M4 1.6
1 x (1.5 – 6) 2 x (1.5 – 6) 1 x (1 – 4) 2 x (1 – 4) M4 1.6
1 x (2.5 – 35) 2 x (2.5 – 10) 1 x (1.5 – 25) 2 x (1.5 – 6) M5 3
1 x (2.5 – 35) 2 x (2.5 – 10) 1 x (1.5 – 25) 2 x (1.5 – 6) M5 3
A A A A A A kW kW kW kW kW kW kW kW
240 190 150 170 150 25 5.5 7.5 7.5 7.5 7 13 11 11
320 260 300 290 250 32 7.5 13 18.5 15 8.5 15 18.5 18.5
800 640 600 590 340 63 15 30 30 30 18.5 37 37 30
950 760 740 880 520 100 22 37 45 37 30 50 65 45
A V A Quantity A Quantity A Quantity A Quantity
25 60 25 1 25 2 25 3 12 3
32 60 25 1 25 2 25 3 12 3
63 60 50 1 50 2 50 3 25 3
100 60 50 1 50 2 50 3 25 3
mm2
Flexible with ferrule to DIN 46228
Notes
x 106
Open Enclosed
AB 60 % DF AB 40 % DF AB 25 % DF Short-circuit rating Fuse Rated short-time withstand current (1 s current) Isolating characteristics to IEC/EN 60947 Safe isolation to VDE 0106 Part 101 and Part 101/A1 Safe isolation to VDE 0106 Part 101 and Part 101 A1 between auxiliary contacts and main contacts Switching angles Contacts Current heat loss per contact at Ie Terminal capacities Solid or stranded
7/67
Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected cross-section. For terminal capacity solid, stranded and flexible: Max. 2 cross-section sizes difference admissible when using 2 conductors.
Rotary switches, switch-disconnectors
Technical data Switch-disconnectors
Rotary switches, switch-disconnectors
7/68
Technical data Switch-disconnectors P5
Moeller HPL0211-2007/2008 P5-125
General Standards Lifespan, mechanical
Operations
Maximum operating frequency Climatic proofing
Operations/h
Ambient temperature
Open Enclosed
x 106
°C °C
Mounting position Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current Load rating with intermittent AB 60 % DF operation, class 12 AB 40 % DF AB 25 % DF Short-circuit rating Fuse Rated short-time withstand current (1 s current) Isolating characteristics to IEC/EN 60947 Safe isolation to VDE 0106 Part 101 and Part 101/A1 Safe isolation to VDE 0106 Part 101 and Part 101 A1 between auxiliary contacts and main contacts Switching angles Contacts Current heat loss per contact at Ie
Ue Uimp
V AC V AC
Iu
Icw
Terminal capacities Solid or stranded Copper band, 1 band
Number of segments x width x thickness
P5-250
P5-315
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL switch disconnector according to IEC/EN 60947-3 0.1 0.1 0.08 0.08 50 50 50 50 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 -25…50 -25…50 -25…50 -25…50 -25…40 -25…40 -25…40 -25…40 As required As required As required As required
A x Ie x Ie x Ie A gG/gL Arms V AC
690 8000 III/3 125 1.3 1.6 2 125 2500 690
690 8000 III/3 160 1.3 1.6 2 160 3000 690
690 8000 III/3 250 1.3 1.6 2 250 4600 690
690 8000 III/3 315 1.3 1.6 2 315 5800 690
V AC
440
440
440
440
° Number W
90 max. 3 (+N) 8
90 max. 3 (+N) 10
90 max. 3 (+N) 13
90 max. 3 (+N) 16
mm2
1 x (10 – 95) 2 x (10 – 35) 6 x 9 x 0.8
1 x (10 – 95) 2 x (10 – 35)
1 x (16 – 185) 2 x (16 – 70) 6 x 20 x 1
1 x (16 – 185) 2 x (16 – 70)
mm
Copper band, 2 bands Flexible with ferrule to DIN 46228
mm mm2
Terminal screw Tightening torque
Nm
Notes
P5-160
http://catalog.moeller.net
1 x (16 – 70) 2 x (16 – 25) Allen screw 5 14
6 x 9 x 0.8 1 x (16 – 70) 2 x (16 – 25) Allen screw 5 14
Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected cross-section. For terminal capacity solid, stranded and flexible: Max. 2 cross-section sizes difference admissible when using 2 conductors.
1 x (25 – 120) 2 x (25 – 50) Allen screw 6 16
6 x 9 x 0.8 1 x (25 – 120) 2 x (25 – 50) Allen screw 6 16
http://catalog.moeller.net
DC-23A, motor load switch L/R = 15 ms
24 V 48 V 60 V 120 V
Notes
P5
Moeller HPL0211-2007/2008
Switching capacity Alternating voltage Rated making capacity cos v = 0.35 Rated breaking capacity, motor load 230 V switch cos v = 0.35 400 V 500 V 690 V Rated operational current 440 V load-break switch AC-21A AC-3 motor load switch motor rating 230 V 400 V 690 V AC-23A Motor load switches (main 230 V switches maintenance switches) 400 V 690 V DC DC-1, Load-break switches L/R = 1 ms Rated operational current DC-1, Load-break switches L/R = 1 ms Voltage per contact pair in series Rated operational current Contacts Rated operational current Contacts Rated operational current Contacts Rated operational current Contacts
7/69
P5-125
P5-160
P5-250
P5-315
A A A A A A kW kW kW kW kW kW
850 800 750 650 340 125 22 37 30 30 45 37
1050 900 850 850 340 160 30 45 37 30 55 37
1700 1600 1380 1250 400 250 37 55 45 37 90 45
2050 1800 1650 1550 400 315 45 75 45 55 110 45
Ie
A V
125 42
160 42
250 42
315 42
Ie
A Quantity A Quantity A Quantity A Quantity
125 3 125 3 125 3 40 3
160 3 160 3 160 3 50 3
250 3 250 3 250 3 80 3
315 3 315 3 315 3 100 3
Ie P P P P P P
Ie Ie Ie
Main switch characteristics to IEC/EN 60204; positive opening of contacts, operator element positively located on shaft The rated uninterrupted current Iu is stated at max. connected cross-section. For terminal capacity solid, stranded and flexible: Max. 2 cross-section sizes difference admissible when using 2 conductors.
HI...-P1(P3)... Auxiliary contacts Standards Rated insulation voltage Rated uninterrupted current Rated operational current AC-15 with 230 V 380 V/415 V DC-13 125 V 250 V Short-circuit rating Maximum fuse Terminal capacities Solid Flexible with ferrule to DIN 46228 Tightening torque Control circuit reliability at 24 V DC, 10 mA
HI...-P5...
Control circuit isolators to IEC/EN 60947-5f Ui Iu
V AC A
500 10
500 10
Ie Ie
A A
6
6 3
Ie Ie
A A
1.1 0.55
0.23 0.1
A gG/gL
10
10
mm2 mm2 Nm HF
0.75 – 2.5 0.75 – 2.5 0.5 – 1.5 0.5 – 2.5 0.6 0.8 < 10 -5, < 1 fault in 100 000 operations
Fault probability
Rotary switches, switch-disconnectors
Technical data Switch-disconnectors, auxiliary contacts
Technical data Rotary switch
Technical data Rotary switch
T
Moeller HPL0211-2007/2008 T0-...
General Standards
Lifespan, mechanical Maximum operating frequency Climatic proofing Ambient temperature Open Enclosed Mounting position Mechanical shock resistance to IEC 60068-2-27 Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated uninterrupted current open Enclosed Load rating with intermittent operation, class 12 AB 25 % DF AB 40 % DF AB 60 % DF Short-circuit rating Fuse Rated short-time withstand current (1 s current) Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the contacts Switching angles
Operations Operations/h
x 106
°C °C
T3-...
http://catalog.moeller.net T5B-...
T
Moeller HPL0211-2007/2008 T5-...
T6-3-8212/E/HI12
T6-160-...
T8-...
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnectors to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3 1 0.5 3000 3000 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnectors to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3 0.5 0.5 0.1 0.1 3000 3000 50 50 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
25…50 25…40 As required > 15
25…50 25…40 As required > 15
25…50 25…40 As required > 15
25…50 25…40 As required > 15
25…50 25…40 As required
25…50 25…40 As required
25…50 25…40 As required
0.1 50
Half-sinusoidal shock 20 ms
g
Ue Uimp
V AC V AC
690 6000 III/3
690 6000 III/3
690 6000 III/3
690 6000 III/3
690 6000 III/3
690 8000 III/3
690 8000 III/3
Iu Iu
A A
20 20
32 32
63 63
100 100
125 125
160 160
315 275
x Ie x Ie x Ie
2 1.6 1.3
2 1.6 1.3
2 1.6 1.3
2 1.6 1.3
2 1.6 1.3
2 1.6 1.3
2 1.6 1.3
A gG/gL Arms
20 320
35 650
80 1300
100 1850
200 2000
160 3000
315 4200
V AC °
440 90 60 45 30 11 max. 22 0.6
440 90 60 45 30 11 max. 22 1.1
440 90 60 45 30 10 max. 20 4.5
440 90 60 45 30 10 max. 20 7.5
90 60
90 60
90 60
3 max. 6 11
3 max. 6 11
3 max. 6 11
1 x (1 – 2.5) 2 x (1 – 2.5) 1 x (0.75 – 1.5) 2 x (0.75 – 1.5)
1 x (1 – 6) 2 x (1 – 6) 1 x (0.75 – 4) 2 x (0.75 – 4)
1 x (2.5 – 35) 2 x (2.5 – 16) 1 x (1.5 – 25) 2 x (1.5 – 10)
1 x (2.5 – 35) 2 x (2.5 – 16) 1 x (1.5 – 25) 2 x (1.5 – 10)
1 x 70 2 x 25 1 x 50 2 x 16
1 x 95 2 x 25 1 x 50 2 x 16
150
Icw
Contact units Double-break contacts Current heat loss per contact at Ie
W
Terminal capacities Solid or stranded
mm2
Flexible with ferrule to DIN 46228
mm2
Flat conductor connection with busbars
mm2
Terminal screw Tightening torque
Nm
Notes
http://catalog.moeller.net
M3.5 1
For mechanical shock resistance: T3.../I... >12g Applies to T0(3).../SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC Applies to rated uninterrupted current Iu of the contact: with T5-4-8344/I5 max. 95 A For terminal capacity solid, stranded and flexible: T0(3), (6), (8)...: Maximum of 2 cross-section sizes difference admissible between 2 conductors T5(B)-...: Maximum of 1 cross-section size difference admissible between 2 conductors For type T8-3-8342/... the following applies: switching angle = 90° and flat connection = 1 busbar 25 x 5 or 2 busbars 20 x 3
M4 1.6
M6 4
M6 4
M6 5.6
M5, Allen key 14
120 1 x (25 x 5) 2 x (20 x 3) M12 25
7/71 Rotary switches, switch-disconnectors
Rotary switches, switch-disconnectors
7/70
Technical data Rotary switch
Technical data Rotary switch
T
Moeller HPL0211-2007/2008
http://catalog.moeller.net
http://catalog.moeller.net
T
Moeller HPL0211-2007/2008
T0-...
T3-...
T5B-...
T5-...
T6-3-8212/E/HI12
T6-160-...
T8-...
A A A A A A kW kW kW kW kW kW kW kW kW kW kW kW A A A
130 100 110 80 60 20 3 4 4 5.5 5.5 7.5 4 5.5 3.5 6.5 13
320 260 260 240 170 32 6.5 11 12 18.5 15 22 15 22 7.5 13 15
6 4 2
10 6 4
800 520 600 480 340 63 15 22 22 37 22 37 22 37 15 22 22 22 16 6 4
950 760 740 590 420 100 22 30 30 45 37 55 30 45 18.5 30 37 30 16 6 4
1600 1280 900 880 340 125 22 22 37 37 37 37 22 22 37 45 55 30 – – –
1600 1280 900 880 340 160 22 22 45 45 37 37 22 22 37 55 55 30 – – –
2390 1910 1800 1200 420 315 22 37 55 55 37 37 37 37 75 132 75 37 – – –
A V A
10 60 1
25 60 1
63 60
80 60
125 42
125 42
315 42
1 1 10 25 1 1 10 25 2 2 10 25 3 3 5 12 3 3 5 5 5 5 10 20 32 32 < 10 -5, < 1 fault in 100000 operations
50 – 1 – 50 – 2 – 50 – 3 – 25 – 3 – 20 – 6 – 25 – 24 – < 10 -5, < 1 fault in 100000 operations
125 1 125 2 125 3 50 3 – – 125 24
125 1 125 2 125 3 50 3 – – 125 24
250 1 250 2 125 3 50 3 – – 250
Fault probability
Quantity A Quantity A Quantity A Quantity A Quantity A Quantity A V HF
Ui Iu
V AC A
– –
– –
– –
– –
Control circuit isolators to IEC/EN 60947-5f 500 500 10 10
– –
Ie Ie
A A
– –
– –
– –
– –
6 4
6 4
– –
A gG/gL
–
–
–
–
10
10
–
mm2
–
–
–
–
0.75 – 2.5
0.75 – 2.5
–
mm2
–
–
–
–
0.5 – 1.5
0.5 – 1.5
–
Nm HF
–
–
–
–
0.35 0.35 < 10-5, < 1 fault in 100 000 operations
Switching capacity Alternating voltage Rated making capacity cos v = 0.35 Rated breaking capacity, motor load switch cos v = 0.35
230 V 400 V 500 V 690 V Rated operational current 440 V load-break switch AC-21A 230 V AC-3 motor load switch motor rating 230 V Star-delta 400/415 V 400 V Star-delta 500 V 500 V Star-delta 690 V 690 V Star-delta AC-23A Motor load switches (main 230 V switches maintenance switches) 400/415 V 500 V 690 V Rated operational current control switch 230 V AC-15 400/415 V 500 V
Ie P P P P P P P P P P P P Ie Ie Ie
DC-1, Load-break switches L/R = 1 ms
Ie
DC
DC-21A
Rated operational current Voltage per contact pair in series Rated operational current 240 V
240 V Contacts Rated operational current Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts 240 V Rated operational current Contacts Rated operational current DC-13, Control switches L/R = 50 ms Voltage per contact pair in series Control circuit reliability at 24 V DC, 10 mA DC-23A, motor load switch L/R = 15 ms
24 V
Auxiliary contacts Standards Rated insulation voltage Rated uninterrupted current Rated operational current AC-15 with 230 V 380 V/415 V Short-circuit rating Maximum fuse Terminal capacities Solid
Ie
Ie Ie Ie Ie Ie Ie
Flexible with ferrule to DIN 46228 Tightening torque Control circuit reliability at 24 V DC, 10 mA
Fault probability
7/73 Rotary switches, switch-disconnectors
Rotary switches, switch-disconnectors
7/72
7/74
Technical data Mini rotary switches TM
Moeller HPL0211-2007/2008
http://catalog.moeller.net
TM
Mini rotary switches
General Standards
IEC/EN 60947, VDE 0660 UL, CSA Control switches to IEC/EN 60947-5-1 Control circuit isolators to IEC/EN 60947-5-1
Control circuit isolators (IEC/EN 60947-5-1) Lifespan, mechanical Maximum operating frequency Climatic proofing
Operations Operations/h
Ambient temperature Open Enclosed Mounting position Terminal capacities Solid
x 106
°C °C
–25…50 –25…40 As required
mm2
1 x 1,5 2 x 1,5 1 x 1,5 2 x 1,5 1 x 14 2 x 14 1 x 16 2 x 16 M2.5 0.35
Flexible without ferrule
mm2
Solid or stranded
AWG
Flexible
AWG
Terminal screw Tightening torque
Nm
Contacts Mechanical variables Contacts Contact units Switching angles
Number °
Min. switching angle for On-Off-On Max. number of switch positions Thickness of gold coating Electrical characteristics Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree Rated insulation voltage Rated insulation voltage for UL/CSA Rated uninterrupted current
Switching capacity AC-23 Motor load switches
AC-15 Control switches
° mm
Voltage per contact pair in series 240 V AC, 3-pole 277 V AC, 1-pole 300 V AC Heavy duty Max. short-circuit protective device Fuse Control circuit reliability at 24 V DC, 10 mA
Max. 16 8 90 60 45 30 60 F 12 35
Ue Uimp
V AC V AC
Ui
V AC V AC A
500 4000 III/3 500 300 10
kW kW kW kW A
1.8 3 0.75 1.1 2.5
A A A A A
1.5 1 10 0.7 – 0.3 3
V HP HP A
32 1 o 10
A gG/gL HF
10 < 10-5, < 1 fault in 100000 operations
Iu
230 V AC, 3-pole 440 V AC, 3-pole 230 V AC, 1-pole 440 V AC, 1-pole 230 V AC, 1-pole
400 V AC, 1-pole 440 V AC, 1-pole DC-1 Load-break switches 1 – 24 V DC 110 … 240 V DC DC-13, Control switches L/R = Rated operational current 50 ms
Maximum 6 contacts; switching angle 90° 1 3000 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
Ie
Switching capacity (UL489, CSA 22.2 No. 5.1)
Fault probability
Technical data Small enclosures CI-K
Moeller HPL0211-2007/2008 CI-K1
General Standards
Climatic proofing Ambient temperature Ambient temperature with push-through cable entry Protection type Degree of protection with push-through cable entry Dissipatable heat loss
°C °C
Material characteristics Material Base, Cover Surface treatment Colour Base Cover Material properties Electrical Creepage resistance to IEC 60112 Base Cover Surface resistance to IEC 60093 Dielectric strength to IEC 60243-1 Thermal Continuous thermal stability Enclosures Gasket Mechanical IK code to EN 50102 Weight of components fitted per mounting rail with mounting plate Chemical resistance Base, Cover Resistant Partially resistant Not resistant Push-through membrane (CI-K1/CI-K2) and sealing material Resistant
To IEC 2 to UL 94 Halogen free
CI-K3
IEC/EN 60529 DIN 43660 EN 50262 Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 –25…70 –25…40 IP 65 IP 65 IP 65 IP 65 IP 65 IP 65 a Chapter 14, Technical data
CI-K4
CI-K5
IP 65 IP 65
IP 65 IP 65
0.75 0.9
0.65 1
Glass-fibre reinforced polycarbonate Resistant to corrosion RAL 9005, black (matt) Enclosure cover RAL 7035, light grey (matt)
O x 1013 kV/mm
CTI175 CTI175 1 30
°C °C
-40…120 -40…80 Please enquire
kg kg
0.2
0.7
0.85 0.85
Acids < 10 %, mineral oil, petrol, grease, saline solution Acids > 10 %, alcohol Alkalis, benzol Acids < 10 %, alkalis, alcohol, saline solution Acids < 10 %, grease, benzol
Partially resistant Not resistant Atmospheric Saline spray UV resistance Water consumption to DIN EN ISO 62 Flammability characteristics Glow wire test Base, Cover Glow wire to VDE 0471 Part 2 to UL 94 Push-through membrane (CI-K1/CI-K2) and sealing material
CI-K2
Mineral oil, petrol
%
IEC 60068-2-11 Beneath protective shield 0.29 0.29
°C
Thickness 960/1 mm VO/1.5 mm thick
°C
650/1 mm thick HB Yes
0.29
0.29
0.29
Small enclosures, empty enclosures
http://catalog.moeller.net
7/75
Dimensions Rotary switch T0, T3
Moeller HPL0211-2007/2008
http://catalog.moeller.net
Flush mounting Drilling dimensions
T0.../E (+ H3-T0) T3.../E (+ H3-T0) H3-T0
48
30
90
10 – 11
5
17
b
3.1 – 3.5
101
25
12.2 48 c20
75
35
Centre mounting Drilling dimensions
T0.../EZ T3.../EZ
T0
T3 3.2
b
24.1 +0.4 0
54
48
45 48
17
1.5 – 5
22.3 61
48
48 c21
35
Part no. c20 c21 61 41 T0-1... 70 50 T0-2... 80 60 T0-3... 89 69 T0-4... 99 79 T0-5... 108 88 T0-6... 118 98 T0-7... 127 107 T0-8... 137 117 T0-9... 146 126 T0-10... 156 136 T0-11... One contact unit depth 9.5 mm
Part no. c20 c21 64 44 T3-1... 76 56 T3-2... 87 67 T3-3... 99 79 T3-4... 110 90 T3-5... 122 102 T3-6... 133 113 T3-7... 145 125 T3-8... 156 136 T3-9... 168 148 T3-10... 179 159 T3-11... One contact unit depth 11.5 mm
��� Not included as standard Service distribution board mounting Drilling dimensions base
T0.../IVS
c22 5
48
55
54
얒5
M4
50
50
45 28
60
얒5
45 55
Rotary switches, switch-disconnectors
7/76
+0.4 0
Dimensions Rotary switches T0, T3
Moeller HPL0211-2007/2008
Rear mounting T0.../Z T3.../Z
Drilling dimensions base
Rotary switches, switch-disconnectors
http://catalog.moeller.net
7/77
Drilling dimensions door
��� Extension possible with ZAV-T0 F 4 x 25 = 100 mm
b
T0
5
5
O5
22.
17
3
5 – 5.5 +0
.4
0
36
50
M4
48
50 60
a
25
48
48
36 O5
T3
O5
22.
3
5 – 5.5 +0
.4
0
54 R
M4
36
65
35
55
c24 38,
65 75
c23
100
63
36 O5
Part no.
c20
c21
c22
c23
77 61 41 T0-1... 87 70 50 T0-2... 96 80 60 T0-3... 106 89 69 T0-4... 115 99 79 T0-5... 125 108 88 T0-6... 134 118 98 T0-7... 144 127 107 T0-8... 154 137 117 T0-9... 163 146 126 T0-10... 173 156 136 T0-11... One contact unit depth 9.5 mm
48 57 67 76 86 95 105 114 124 133 143
c24 f/F 86 – 102 96 – 112 105 – 121 115 – 131 124 – 140 134 – 150 143 – 159 153 – 169 162 – 178 172 – 188 181 – 197
c24 with F 4 ZAV 202 212 221 231 240 250 259 269 278 288 297
c25
Part no.
c20
c21
c22
c23
72 72 91 91 – – – – – – –
80 64 44 T3-1... 92 76 56 T3-2... 103 87 67 T3-3... 115 99 79 T3-4... 126 110 90 T3-5... 138 122 102 T3-6... 149 133 113 T3-7... 161 145 125 T3-8... 172 156 136 T3-9... 184 168 148 T3-10... 195 179 159 T3-11... One contact unit depth 11.5 mm
51 63 74 86 97 109 120 132 143 155 166
c24 f/F 86 – 105 101 – 115 112 – 128 124 – 139 135 – 151 147 – 162 158 – 174 170 – 185 181 – 196 193 – 208 204 – 219
c24 with F 4 ZAV 205 216 228 239 251 262 274 285 296 308 319
c25 79 79 101 101 – – – – – – –
��� Not included as standard Flush mounting main switch T0.../EA/SVB T3.../EA/SVB
Drilling dimensions door
b
T0
F5
3.1 – 3.5
30
ON
49
33
I
10 – 11
17
45
48
o
OFF
T3 25
65
12.2
54
OFF
o
c20 35 61
Drilling dimensions base
b
얒5
50 60
17 ON
5 – 5.5 +0 .4 0
M4
33
I
T0
25
5
22.
3
F5
50
48
Drilling dimensions door
36
Rear mounting main switch T0.../V/SVB T3.../V/SVB
o
OFF
49
OFF
얒5 c23 c24 f 38, F 54
35
T3 00
1 Rf
a 63
��� Interlock extension possible with ZVV-T0 + ZAV-T0, F 4 x 25 = 100 mm ��� Not included as standard
얒5
65
65
36
65 75
o
M4
Dimensions Rotary switches T0, T3
Moeller HPL0211-2007/2008
http://catalog.moeller.net
Surface mounting T0.../I1 Drilling dimensions base
M20 127
120
137
M4
c25
80
27
T3.../I2
Drilling dimensions base M4
171
∅8
180
160
M20 / M25
c25
100
c33
Surface mounting main switch
Drilling dimensions base
T0.../I1/SVB
o
120
ON
127
M20
I
OFF
137
M4
o OFF
c25
80
35
T3.../I2/SVB
Drilling dimensions base
d
o
o
OFF
100
Part no. T0-1... T0-2... T0-3... T0-4...
c25 75 75 95 95
d = 4 – 8 mm b + d F 47 mm
171
ON
M20 /M25
160
I
OFF
쏗8
c25
M4
b
F 3 padlocks
180
Rotary switches, switch-disconnectors
7/78
35
Part no. T3-1... T3-2... T3-3... T3-4... T3-5...
c25 80 80 100 100 145
c33 27 27 35 35 35
http://catalog.moeller.net
7/79
T0, T3, P1, P3
Moeller HPL0211-2007/2008
Key operation S-T0 S-SOND...-T0
T0.../E(I1) + S-(SOND-)T0 T3.../E(I2) + S-(SOND-)T0
T0.../EZ Ⳏ T0../E + EZ-T0 + S-(SOND-)T0 T3.../EZ Ⳏ T3../E + EZ-T0 + S-(SOND-)T0
T0.../Z + S-(SOND-)T0 T3.../Z + S-(SOND-)T0
b
5
5 19 36
27 48
27 44
30
3.1 – 3.5
22
10...11
.3
얒 22:25 – 28 얒 30:23 – 26
c20
100
R
5 – 5.5 +0
.4
3.2
3.2
17
30
36
0
12.5
48
17
2–5
36
12.2
22.3 + 0.4
30.5
0
Cylinder lock
b
T0.../Z/SVA... T3.../Z/SVA... P1.../Z/SVA
T0.../E/SVA... T3.../E/SVA... P1.../E/SVA
T0.../I1/SVA T3.../I2/SVA P1.../12/SVA
56
56
73
73
73
56
46
48
73
SVA-T3
30
46
30
30
46
Padlocking feature
56
56
73 48
48 73
73
56
46
46
46
48
73
b
T0.../Z/SVC... T3.../Z/SVC... P1.../Z/SVC
T0.../E/SVC... T3.../E/SVC... P1.../E/SVC
T0.../I1/SVC T3.../I2/SVC P1.../12/SVC
48
SVC-T3
Modules Switched neutral N-P... Auxiliary contact HI 11-P1/P3 a33 a3 H-P... 5 L3
3 L2
1
1
L1
3
5
N
T3
T2 6
a32
Part no. P1-... P3-..
N-P
T1 4
2
2
a32
a31
a3 49 72
a31 15 18
��� Not included as standard
a32 15 15
a33 83 114
b31 49 60
a32
HI 11
N
a31
4
6
a32
b31
d
b
F 3 padlocks
d = 4 – 8 mm b + d F 47 mm
Rotary switches, switch-disconnectors
Dimensions Rotary switches, switch-disconnectors, accessories
Dimensions Rotary switches T5B, T5
Moeller HPL0211-2007/2008
http://catalog.moeller.net
Flush mounting T5(B).../E
Drilling dimensions door
b
18
27
4.1 – 4.5 I
12 – 13
37
ON
OFF
86
88
o
14 88
F5 c2
37
Rear mounting T5(B).../Z
Drilling dimensions base
Drilling dimensions door
a b
c20 F5 5 – 5.5
27
25 88
.5
88
M6
30
o OFF
25
c2
48
37 f 38, F 54
R f 100
��� Shaft extension possible with ZAV-P3 F 4 x 25 = 100 mm Flush mounting main switch T5(B).../EA/SVB
Drilling dimensions door
b
88
F5
27
c2
4.1 – 4.5
25
ON
80/90
44
80/90
88 o
OFF
OFF
37
12 – 13
o
88
I
48
ON
73
I
14
100
40.5 16.5
Rear mounting main switch T5(B).../V/SVB
Drilling dimensions base
b
Drilling dimensions door
F5 c20
27
5
5 – 5.5
73
88
25 88
25 48
44
a 12
c2
c20 f/F 92 – 107 T5(B)-1... 54 109 – 124 T5(B)-2... 71 125 – 140 T5(B)-3... 87 142 – 157 T5(B)-4... 104 158 – 173 T5(B)-5... 120 175 – 190 T5(B)-6... 137 191 – 206 T5(B)-7... 153 208 – 223 T5(B)-8... 170 224 – 239 T5(B)-9... 186 240 – 356 T5(B)-10... 203 One contact unit depth 16.5 mm
c20 with F 4 ZAV 207 224 240 257 273 290 306 323 339 356
Rotary switches T5B and T5 are same size, only thier contacts are different
R f 100
40.5
16.5
Part no.
.5 30
o
c21
c22
90 90 123 123 – – – – – –
125 (95) 125 (95) 160 (160) 160 (160) – – – – – –
��� Extension possible with ZVV-P3, F 4 x 25 = 100 mm ��� Not included as standard
48
I ON oOFF OFF
Rotary switches, switch-disconnectors
7/80
http://catalog.moeller.net
7/81
T5B, T5
Moeller HPL0211-2007/2008
Surface mounting T5B.../I4 T5.../I5
c22
160
M25 M50 M20
280
240
M25 M32 M20
29
200
37
c22
Surface mounting main switches T5B.../I4/SVB
Drilling dimensions
d
b
F 3 padlocks
M5
ON
o
o
193
240
I
OFF
d = 4 – 8 mm b + d F 47 mm
OFF
142
c22
160
44
T5.../I5/SVB
Drilling dimensions
I
ON
o
OFF
280
M5
233
o
OFF
182
c22
200
44
External fixing bracket AB-CI-K415
Part no. c22 125 T5(B)-1... 125 T5(B)-2... 160 T5(B)-3... 160 T5(B)-4... One contact unit depth 16.5 mm
7.8 3.8
M5 6.5
5.5
20
t=3
36
6 52
Rotary switches T5B and T5 are same size, only thier contacts are different
Rotary switches, switch-disconnectors
Dimensions Rotary switches
Dimensions Rotary switches T6, T8
Moeller HPL0211-2007/2008
http://catalog.moeller.net
Flush mounting
b2
58
T6-3-8212/E/HI12 T8.../E/HI12
a2
5 c30
150 c2
T6-160-6/V/SVB-SW/HI11
T8-3-8342/V/SVB-SW/HI11 H-T6-100
2
6.4
19
7
93
9 216 200
a2
b2
c2
4.5
73 104 5.5 1
c30
0 R 10
d1
d2
x1
y1
9.2
172.8 315 218
130 250
86.5 7 1
Drilling dimensions door d2
152 173
44 62 –
∅ 26 – 30 ∅ 22 – 25 ∅ 26 – 30
∅ 6.0 68 ∅ 7.0 104 ∅ 7.0 68
68 104 68
y1
88 130 –
d1 x1
T6: 4 M5 x 20 T8: 4 M6 x 20
F 3 padlocks for T.../SVB d
b
T6-3-8212/E/HI12 88 130 T8.../E/HI12 – T8.../SVB
130
68
76 224
5
Part no.
88
68
108
118
H-T8
2
Rotary switches, switch-disconnectors
7/82
d = 4 – 8 mm b + d F 47 mm
0 R 10
Dimensions Switch-disconnectors
P.../E
P1, P3
Moeller HPL0211-2007/2008
Centre mounting Drilling dimensions Door P1-.../E
P1.../EZ
b2
0 OFF
L2
3
L1
T3
T2 6
1
12 – 13
T1 4
2
c2
22.3 +0.4 0
12.2
5 c21
a3
a2
10 – 11
5
4.1 – 4.5
3.2
37
L3
ON
b3
I
P1-.../EZ
30
b22
3.1 – 3.5
12.5
Flush mounting
Rotary switches, switch-disconnectors
http://catalog.moeller.net
7/83
14
P1.../EZ = c2 + 5 mm
Service distribution board mounting P3.../IVS
F 3 padlocks
a32
d
a32
L3
L1
L2
L3
L1
L2
L3
T2
T3
d = 4 – 8 mm b + d F 47 mm 45
L2
c3
b3
L1
b
5
P1.../IVS 5
c3 c23 c22
b3
45
HI11 N T1
T1
T2
T3
T1
a31
a4
T2
T3
28
49 55
Rear mounting Drilling dimensions Bottom P1…/Z
P…/Z
Door 5 – 5.5
65
b22
M4
36
5
햲
22.3
+0.4 0
b2
b3
36 c31 c32 5
P3…/Z 5 – 5.5
a3
.5 30
c21
c25 c20 38,
75
M4 3
48
a2
R
54
100
48
25
��� Shaft extension possible with ZAV-... F 4 x 25 = 100 mm
Part no. P1 P3
a2 48 87
a3 49 72
a4 53.5 71.5
a21 65 87
Part no.
c2
c3
c20 f/F
P1 P3
59 59
86 82
96 – 112 103 – 118
a22 48 87
c20 with F 4 ZAV/ZVV 212 218
a23 87 125
a31 15 18
a32 15 15
a33 83 114
b2 48 87
b3 70 83
b21 65 87
b22 17 27
b23 180 175
b24 32 –
c21
c22
c23
c24
c25
c27
c28
c31
c32
c33
35 37
32 41
65 63
68 81
58 65
35 44
77 90
25 25
25 25
27 29
b31 49 60
Dimensions Switch-disconnectors P1, P3
Moeller HPL0211-2007/2008
http://catalog.moeller.net
Flush mounting main switches
P…/EA/SVB
Drilling dimensions Door P1…
P3…
3.1 – 3.5
4.1 – 4.5
b
a22
3
b3
b21
OFF
1
y
OFF
N
o
6
12 – 13
y
N
37
5
30
ON
b31
I o
10 – 11
b22
H-P...
2
4
12.2 a21
14
a3 F5 25
c27
c2
Rear mounting main switches Drilling dimensions Bottom P1…/V/SVB
P…/V/SVB
a
M4
b22
H-P...
36
5 – 5.5
65
a22
36 3
1
o OFF
5
N
P3…/V/SVB
b3
ON
+0.4 0
5 – 5.5
N 2
6
4
a21
3
a3
100
M4
.5
Rf
f 38, F 54
30
c25 c20
75
o
48
25
��� Interlock extension possible with ZVV-...+ZAV... F 4 x 25 = 100 mm ��� Not included as standard
48
b31
22.3
b21
I
Door
c27
F5
5
b
OFF
Layout
Surface mounting main switches/safety switches
P1.../I2
P1.../I2/SVB P1.../I2/SI
Drilling dimensions
M4
M25 F8
M25
c28
a23
Part no. P1.../I2
a2 48
a3 49
a4 53.5
a21 65
Part no.
c2
c3
c20 f/F
P1...
59
86
96 – 112
171
M25
b23
160
Rotary switches, switch-disconnectors
7/84
c33
a22 48
c20 with F 4 ZAV/ZVV 212
c27
a23 100
a31 15
a32 15
a33 83
b2 48
b3 70
b21 65
b22 17
b23 180
b24 35.5
c21
c22
c23
c24
c25
c27
c28
c31
c32
c33
35
32
65
68
58
35
80
25
25
27
b31 49
Dimensions Switch-disconnectors P5
Moeller HPL0211-2007/2008
Rotary switches, switch-disconnectors
http://catalog.moeller.net
7/85
Flush mounting P5.../E
Drilling dimensions F5
q 68
q 88
b
88
68
M5
6 26 – 30 35
8
a c
Flush mounting main switches P5-.../EA/SVB(-SW) HI10
q 88
88
b b2
68
88
b2
M5
F5 a1
21
a2
a
26
c
49.3
a2
Rear mounting P5.../Z
Drilling dimensions
q 88
b
b1
q 68
2
6.4
6 26 – 30
2
F5 c
a1
8
a
35
c1
Rear mounting main switches
F5
26
Rf a2
a
c
a2
49.3
c1
Part no. P5-125/160 P5-250/315
a 112 145
a1 36 44
a2 38 52.5
b 108 126
b1 120 144
b2 76 88
c 91 98
c1 f 130 f 140
F 287 F 280
100
q 88
b2
b
88
b2
P5-.../V/SVB(-SW)
Dimensions Switch-disconnectors P3
Moeller HPL0211-2007/2008
Layout P3-63/I4
http://catalog.moeller.net
Surface mounting main switches/safety switches Drilling dimensions P3-63/I4/SVB P3-63/I4/SI T5B-.../I4/SI M5
M25 M32
193
M20
b23
142
a23
95
29
95
Layout P3-100/I5
44
Surface mounting main switches/safety switches Drilling dimensions P3-100/I5/SVB P3-100/I5/SI T5-.../I5/SI M5
M25 M50
233
M20
b23
Rotary switches, switch-disconnectors
7/86
182
a23
37
125
Part no. P3-63/I4 P3-100/I5
a2 87 87
a3 72 72
a4 71.5 71.5
a21 87 87
Part no.
c2
c3
c20 f/F
P3-63 P3-100
59 59
82 82
103 – 118 103 – 118
a22 87 87
c20 with F 4 ZAV/ZVV 218 218
a23 160 200
125
a31 18 18
a32 15 15
a33 114 114
b2 87 87
b3 83 83
b21 87 87
44
b22 27 27
b23 240 280
b24 35.5 35.5
c21
c22
c23
c24
c25
c27
c28
c31
c32
c33
37 37
41 41
63 63
81 81
65 65
44 44
125 125
25 25
25 25
37 37
b31 60 60
Dimensions Mini rotary switches TM
Moeller HPL0211-2007/2008
Rotary switches, switch-disconnectors
http://catalog.moeller.net
7/87
Flush mounting Drilling dimensions
TM.../E 3 얒 4.8
8 M3
3.2
28
30
28
M3
20 28 c20
30
Control circuit switches for 2 padlocks ∅ 4 mm or 1 padlock ∅ 6 mm Drilling dimensions
TM-.../E/SVB(-SW) 3
10
38
M4
28
48
M4
4.2
30 38
48
c21
35
Centre mounting Drilling dimensions1)
TM-.../EZ
3.2
16.2 +0.2 0
28
30
17.9
17/19
24.1 +0.4 0
1.7
F 5.5
30
c20
12
22.3
+0.4 0
23
Centre mounting with key operation Drilling dimensions1)
TM-...+EZ/S-.. 17/19
3.2
5.5
17.9
28
30
24.1 +0.4 0
1.7
16.2 +0.2 0 30
c20
12
22.3
35
+0.4 0
Part no. c20 c21 42 39 TM-1... 54 51 TM-2... 66 63 TM-3... 75 TM-4... 87 TM-5... 99 TM-6... 111 TM-7... 123 TM-8... One contact unit depth 12 mm Service distribution board mounting
Note
c1
c2
1))
45
60
45 35.5
Part no. c1 c2 TM-1... 44 21 TM-2... 46 26.5 One contact unit depth 12 mm
35.5
60
TM-.../IVS/S
TM-.../IVS
42
Drilling dimensions either 16.2 mm = without reduction Ⳏ RMQ16; 22.3 mm = with reduction Ⳏ RMQ Titan
21.5
24
7/88
Dimensions Small enclosures Moeller HPL0211-2007/2008
http://catalog.moeller.net
35
17.5
Mounting rails TS-CI-K1
7.5
4.7
39
61
5
72
4.5
74
137
82 120
127
12
1.5
45
37.5
80
57.5
39
95
b 52.5 97.5
35
a 100 145
7.5
22
Part no. CI-K2-100-... CI-K2-145-...
Mounting rails TS-CI-K2 92
Mounting plates M-CI-K2
CI-K2-...
5.2 4.7
52
7.5
a
7
57
5
l
1.5
65
a 77
100
181
171
160
116
18
116
4.5
b
47.5
100
l 92
46
a
22
a 125 160
b 74.5 109.5
7.5
24.5
Part no. CI-K3-125-... CI-K3-160-...
Mounting rails TS-CI-K3 108
Mounting plates M-CI-K3
CI-K3-...
35
20
52
5.2 a
5.3
70
l
116
65
5
a 93
140
222
200
5.5
210
152
27
1.5
b
50.5 a
70
24.5
120
21
easy Relay, easy Control, easy MFD
CI-K Small insulating material enclosures CI-K1...-95-TS
70
l 108
7.5
Dimensions Small enclosures CI-K
Moeller HPL0211-2007/2008 Mounting plates M-CI-K4 b 72.5 107.5
35
a 125 160
7.5
23
30
Part no. CI-K4-125-... CI-K4-160-...
Mounting rails TS-CI-K4
easy Relay, easy Control, easy MFD
Small insulating material enclosures CI-K4-...
143.8
http://catalog.moeller.net
7/89
5.2
7.5
a
74
27
l
5.6
5.3
a 128
90
l 143
5
72.5
52.5
193
72
125
160
154
80
1.5
194
240
154
142
Mounting plates M-CI-K5
Mounting rails TS-CI-K5
183
50.5
35
33.5
CI-K5-...
5.2
7.5
91
27
7.5
a
5.6
l 5.3
233
181
110
280 1.5
234
170
5
b
73.5
87
a
200
Typ CI-K5-125-... CI-K5-160-...
a 125 160
182
a 168
b 51.5 85.5
l 183
Basic enclosures CI-B, CI-C, CI-D 4,5
12
c c1 c2
b3
a1 a
b2
b b2
b1
M4
Part no. CI-B CI-C CI-D
a 87 110 110
a1 71 95 97
b 149 165 222
b1 106 122 179
b2 128 144 201
b3 10.5 10.5 10.5
c 128 128 128
c1 115 115 115
c2 84.4 84.4 84.4