Transcript
RD&CS b&W 28p.qk
3/27/02
12:32 PM
Page 13
KNZ/XNA/XNF - Rotary Disconnects KNZ/XNA/XNF Series ● Pillar-type connection ● Two, three or four pole versions available ● Wiring terminals with IP20 finger safe protection against accidental contact ● Screws provided with captive self-lifting cable clamps, which are supplied in open position, for quick and easy wiring ● Positively-opening double-break contacts, made of silver alloy
KNZ
(non-expandable)
● 16, 30 or 40 Amp rating
XNA
XNF
With fuses (expandable)
● 16, 25 or 32 Amp rating
(expandable)
● 16, 25, 32, 50, 63, 80 or 100 Amp rating
XNA and XNF Expandable with additional pole(s) or auxiliary contact block(s)
or Pending
● When ordering, specify Catalog Number of the disconnect along with the Catalog Number of the front trim plate, because these two products are supplied separately. The standard operating shaft is supplied with the disconnect.
● New modular and shaft extensions
● Available with fast Ø22mm rear mounting
● IP65 rated operating handle
- 13 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
12:38 PM
Page 14
Rotary Disconnects Front Trim Plates Emergency Switches
Switches
With Legend
With Legend
Emergency Switches with Lockout
Switches with Lockout
With Legend
With Legend
Additional Pole(s) and Auxiliary Contact Block(s) For Rear Mounting and Ø22mm Rear Mounting Types
For Base Mounting Types PE
PE
1NC o 1NO auxiliary contact
1NC o 1NO auxiliary contact Additional Pole
Additional Pole
Additional Pole
Additional Pole
1NC o 1NO auxiliary contact
1NC o 1NO auxiliary contact Max 2 on each side
PE
Max 2 on each side
PE
Rotary Disconnects Mounted in Non-metallic IP65 Enclosures Three or Four Pole Emergency Disconnects
Three or Four Pole Disconnects
With Lockout
With Lockout
- 14 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
12:45 PM
Page 15
Rotary Disconnects Housing rear mounting
KNZ - Housing 2 pole Catalog no. BR511000 BR513700 BR516400
Type KNZ16R2000 KNZ30R2000 KNZ40R2000
3 pole Catalog no. BR511300 BR51400 BR516700
Type KNZ16R3000 KNZ30R3000 KNZ40R3000
4 pole Catalog no. BR511600 BR514300 BR517000
Type KNZ16R4000 KNZ30R4000 KNZ40R4000
Ith 16 A 32 A 40 A
XNA - Housing 2 pole Catalog no. BR519100 BR523500 BR528400
XNF -
Type XNA162R XNA252R XNA322R
Catalog no. BR521200 BR5125400 BR530500
Type XNA163R XNA253R XNA323R
4 pole Catalog no. BR523300 BR527500 BR532600
Type XNA164R XNA254R XNA324R
Ith 16 A 25 A 32 A
Housing with fuses
2 pole Catalog no. BR533300 BR535600
3 pole
Type XNF162R XNF322R
3 pole Catalog no. BR533900 BR536500
Type XNF163R XNF323R
4 pole Catalog no. BR534700 BR537400
Type XNF164R XNF324R
Ith 16 A 32 A
Housing base mounting
KNZ - Housing 2 pole Catalog no. BR509200 BR511900 BR514600
Type KNZ16B2000 KNZ30B2000 KNZ40B2000
3 pole Catalog no. BR509500 BR512200 BR514900
Type KNZ16B3000 KNZ30B3000 KNZ40B3000
4 pole Catalog no. BR509800 BR512500 BR515200
Type KNZ16B4000 KNZ30B4000 KNZ40B4000
Ith 16 A 32 A 40 A
XNA - Housing 2 pole Catalog no. BR518500 BR523400 BR527800 -
Type XNA162B XNA252B XNA322B
3 pole Catalog no. BR526600 BR524800 BR529900 BR517300 BR517600 BR517900 BR518200
Type XNA163B XNA253B XNA323B XNA0503B XNA0633B XNA0803B XNA1003B
4 pole Catalog no. BR522700 BR526900 BR532000
Type XNA164B XNA254B XNA324B
Ith 16 A 25 A 32 A 50 A 63 A 80 A 100 A
XNF - Housing with fuses 2 pole Catalog no. BR509200 BR535000
Type XNF162B XNF322B
3 pole Catalog no. BR533500 BR535900
Type XNF163B XNF323B
4 pole Catalog no. BR534100 BR536800
Type XNF164B XNF324B
- 15 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
Ith 16 A 32 A
RD&CS b&W 28p.qk
3/27/02
1:03 PM
Page 16
Rotary Disconnects Front trim plates rear and base mounting to screw KNZ - XNA - XNF
Series
IP65
Switch whith grey plate and black handle
Catalog no. BR540700 BR541000
Type YNUT4 YNUT6
KNZ - XNA - XNF
KNZ - XNA - XNF
SeriesI
P65
Switch whith grey anodized plate and black handle with legend label carrier
Plate dimensions 48x48 67x67
Series
IP65
Catalog no. BR541300
Type YNUT7
KNZ - XNA - XNF
Plate dimensions 67x82
Series
IP65
Emergency-off switch with yellow plate and red handle.
Emergency-off switch with yellow plate and red handle with legend label carrier
Catalog no. BR541600 BR541900
Catalog no. BR542200
Type YNUY4 YNUY6
KNZ - XNA - XNF
Plate dimensions 48x48 67x67
Series
IP65
Type YNUY7
KNZ - XNA - XNF
Plate dimensions 67x82
Series
IP65
Emergency-off main switch with padlock facility in 0 position, yellow plate and red handle.
Emergency-off main switch with padlock facility in 0 position, yellow plate and red handle with legend label carrier
Catalog no. BR540100
Catalog no. BR540400
Type YNUL6
Plate dimensions 67x67
KNZ - XNA - XNF Series
Type YNUL7
Plate dimensions 67x82
KNZ - XNA - XNF Series IP65
IP65
Main switch with padlock facility in 0 position, grey plate and black handle.
Main switch with padlock facility in 0 position, grey plate and black handle with legend label carrier
Catalog no. BR539500
Catalog no. BR539800
Type YNUK6
Plate dimensions 67x67
Type YNUK7
Plate dimensions 67x82
- 16 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
1:07 PM
Page 17
Rotary Disconnects Housing center rear mounting Ø 22
KNZ
-
Hhousing
2 pole Catalog no. Type BR510100 KNZ16G2000 BR512800 KNZ30G2000 BR51…00 KNZ40G2000
3 pole Catalog no. Type BR510400 KNZ16G3000 BR513100 KNZ30G3000 BR51…00 KNZ40G3000
4 pole Catalog no. Type BR510700 KNZ16G4000 BR513400 KNZ30G4000 BR51…00 KNZ40G4000
Ith 16 A 32 A 40 A
3 pole Catalog no. Type BR520900 XNA163G BR525100 XNA253G BR530200 XNA323G
4 pole Catalog no. Type BR523000 XNA164G BR527200 XNA254G BR532300 XNA324G
Ith 16 A 25 A 32 A
3 pole Catalog no. Type BR533800 XNF163G BR536200 XNF323G
4 pole Catalog no. Type BR534400 XNF164G BR537100 XNF324G
Ith 16 A 32 A
XNA - Housing 2 pole Catalog no. Type BR518800 XNA162G BR51…00 XNA252G BR528400 XNA322G
XNF -
Housing with fuses
2 pole Catalog no. Type BR533200 XNF162G BR535300 XNF322G
Front trim plates center rear mounting Ø 22 KNZ - XNA - XNF
Series
KNZ - XNA - XNF
IP65
Switch whith grey plate and black handle
Catalog no. BR538300 BR538600
Type YNGT4 YNGT6
KNZ - XNA - XNF
P65
Emergency-off switch with yellow plate and red handle.
Plate dimensions 48x48 67x67
Series
SeriesI
IP65
Catalog no. BR538900 BR539200
Type YNGY4 YNGY6
Plate dimensions 48x48 67x67
KNZ - XNA - XNF
IP65
Emergency-off main switch with padlock facility in 0 position, yellow plate and red handle.
Main switch with padlock facility in 0 position, grey plate and black handle with legend label carrier
Catalog no. BR53800
Catalog no. BR537700
Type YNGL6
Plate dimensions 67x67
Type YNGK6
Plate dimensions 67x67
- 17 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:16 PM
Page 18
Rotary Disconnects Accessories Shaft extensions • Allows adapting the switches with door interlocking device to the different mounting lengths
1 type
length
BR508300
B - GNAPO
100 mm
BR508600
B - GNAP1
150 mm
BR508900
B - GNAP2
200 mm
2 181
H=100m
3 194
+ 206
191
203
215
231
244
256
241
253
265
min
281
294
306
max
291
303
315
L
code
H=150m
H=200mm
+ 12.2
+ 12.2
+ 12.2
1
2
3
+
216
232
248
225
242
258
266
282
298
275
292
308
316
332
348
325
342
358
+ 16.2
+ 16.2
+ 16.2
Modular extensions • Allows adapting the switches whith door interlocking device to the different mounting lengths • Includes 4 forms that overlap
max 4 3 2
L=(mm)
1
2
3
+
101
114
126
111
123
126
1139
136
148
min
151
max min max
2
3
+
127
143
135
120
137
153
151
136
152
168
160
145
162
178
164
176
161
177
193
161
173
185
170
187
203
176
189
201
186
202
218
186
198
210
195
212
228
+ 16.2
L
1
1 111
+ 12.2
catalog no
type
BR508000
B - GNAMO
length
-
3
3
+ 12.2
+ 12.2
+ 12.2
+ 16.2
+ 16.2
+ 16.2
Plate for base mounting (base mounting) Black label - red label for engraving blank KNZ 16÷40 A
• For front trim plates with legend label carrier
catalog no
type
VC218600
B-KG6047
y x
catalog no
type
length
BR506800
B - 6429
-
Protection shrounds for terminals • Allow increasing the degree of protection of the connection termunals.
XNA 50÷100 A
KNZ 16÷40 A
catalogo n.
type
Terminal cover descriptional
VD456100
B-G1305
3 pole
catalog no.
VC211100
type
B-G1280
Terminal cover descriptional
* The catalog No. includes the upper and lower cover
3- 4 pole
* The catalog No. includes the upper and lower cover
XNA 50÷100 A XNA-XNF 16÷32 A catalog no
type
Terminal cover descriptional
VC286300
B-G813
3- 4 pole
catalogo n.
type
Terminal cover descriptional
VD457900
B-G1304
1 pole
* The catalog No. includes the upper and lower cover
* The catalog No. includes the upper and lower cover
- 18 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:18 PM
Page 19
Rotary Disconnects Additional pole and auxiliary contact block for rear mounting and ø 22 mm PE
XNA - XNF
1NC o 1NO auxiliary contact
Auxiliary contact unit and additional pole for series XNA - XNF
Additional Pole
Catalog no. VC300200 VC301000 VC296200 VC297000 VC302800 VC303600 VC304400
Additional Pole
1NC o 1NO auxiliary contact
PE
Max 2 on each side
Type XC16AN XC16CN XC25AN XC25CN XC32AN XC32CN XC32GN
Ith 16 A 16 A 25 A 25 A 32 A 32 A 16-25-32 A
Contact features 1NO 1NC 1NO 1NC 1NO 1NC PE
Ith 16 A 16 A 25 A 25 A 32 A 32 A 16-25-32 A
Contact features 1NO 1NC 1NO 1NC 1NO 1NC PE
Ith 50-63-80-100A 50-63-80-100 A 50-63-80-100 A 50 A 63 A 80 A 100 A
Contact features 1NO 1NC PE N N N N
Additional pole and auxiliary contact block for base mounting
XNA - XNF
PE
Auxiliary contact unit and additional pole for series XNA - XNF
1NC o 1NO auxiliary contact
Additional Pole
Additional Pole
1NC o 1NO auxiliary contact
Catalog no. VC301000 VC300200 VC297000 VC296200 VC303600 VC302800 VC304400
Type XC16CN XC16AN XC25CN XC25AN XC32CN XC32AN XC32GN
Catalog no. VD459500 VD460300 VD455300 VD298800 VD452000 VD453800 VD454600
Type XC012AB XC012CB XC100GB XC050PB XC063PB XC080PB XC100PB
PE Max 2 on each side 1NC auxiliary contact 1NO auxiliary contact
PE 4th pole
1NO auxiliary contact Max 1 on each side
1NC auxiliary contact
Auxiliary contact NA
Auxiliary contact NC
Earth PE
Fourth pole N
3
1
PE
N
4
2
PE
N
- 19 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 20
Rotary Disconnects Surface mounting
XNA…BXP
IP65
Switch fitted in insulated enclosure and provided with grey front trim plate and black handle 3 pole Catalog no. BR520300 BR524500 BR529600
4 pole Type XNA1630BXP XNA2530BXP XNA3230BXP
Catalog no. BR511300 BR526600 BR531700
Type XNA1640BXP XNA2540BXP XNA3240BXP
XNA…BXG
Ith 16 A 25 A 32 A
IP65
Emergency-off switch fitted in insulated enclosure and provided with yellow front trim plate and red handle 3 pole Catalog no. BR519400 BR523600 BR529700
4 pole Type XNA1630BXG XNA2530BXG XNA3230BXG
Catalog no. BR521500 BR525700 BR530800
Type XNA1640BXG XNA2540BXG XNA3240BXG
XNA…BXL
Ith 16 A 25 A 32 A
IP65
Main switch fitted in insulated enclosure and provided padlock facility in 0 position;yellow front trim plate and red handle pole Catalog no. BR519700 BR523900 BR529000
4 pole Type XNA1630BXL XNA2530BXL XNA3230BXL
Catalog no. BR521800 BR526000 BR531100
Type XNA1640BXL XNA2540BXL XNA3240BXL
XNA…BXN
Ith 16 A 25 A 32 A
IP65
Emergency-off main switch fitted in insulated enclosure and provided with padlock facility in 0 position,grey front trim plate and black handle 3 pole Catalog no. BR512000 BR524200 BR529300
4 pole Type XNA1630BXN XNA2530BXN XNA3230BXN
Catalog no. BR522100 BR526300 BR531400
Type XNA1640BXN XNA2540BXN XNA3240BXN
- 20 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
Ith 16 A 25 A 32 A
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 21
Rotary Disconnects Diagrams KNZ XNA (30-400 A) (16-32 A)
KNZ XNA (16-30-40 A) (16- 100 A)
KNZ XNA (16-30-40 A)(16-25-32 A)
XNA (50÷100 A)
2 - pole
3 - pole
4 - pole
6 - pole
L1
N
L1
L2
L3
L1
L2
L3
N
L1
L2
L3
N
T1
N
T1
T2
T3
T1
T2
T3
N
T1
T2
T3
N
Overall dimensions (mm) of housing base mounting Version
Front view
Side view
83 ÷ 93 7.3
55.5
L L1
L L2
L3
N
T1
T2
T3
N
47
KNZ (16-30-40A)
5
45.5
70
83÷93
XNA (16-32A)
67.5
28.5
4.2
7.3
5
64.5
48
97÷107 60 60
1 L1
3 L2
5 L3
2 T1
4 T2
6 T3
68
80
XNA (50*100)
90
7.3
5.2 23.5 25 6.5
43.5
- 21 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 22
Rotary Disconnects Overall dimensions (mm) of housing base mounting Front view
Side view 83÷93
72.5 48
70 64.5
36.5
DIN 46277/3
Ø15
4.2
28.5
XNF…B (16 A)
33.75
7.3
99.5
Version
15
5 58
75.5 83÷93
70 48
64.5
55.25
24
19.5
65
121.5
33.75
DIN 46277/3
4.2
XNF…B (32 A)
28.5
28.5
7.3
56.5
5
63.5
20
Overall dimensions (mm) XC16CN XC16AN XC25CN XC25AN XC32CN XC32AN XC32GN XC012AB XCO12CB
XC100GB XC050PB XC063PB XC080PB XC100PB
B-KG6047
- 22 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 23
Rotary Disconnects Overall dimensions (mm) of housing rear mounting Version
Front view
Side view
55.5 53
32
KNZ..R (16-30-40A)
10
47
KNZ..G (16-30-40A)
M. 3.5 70 10
67.5
2.2
XNA..R XNF..R (16-32A) XNA..G (16-32A)
28.5
4.2
53
32 64.5 72.5
63
70
Ø15
4.2
99.5
28.5
XNF..R/G (16 A)
36.5
33.75
64.5
15
58
53
75 5 75.
63 48
121.5
19.5
4.2 65
XNF..R/G (32A)
55.25
28.5
33.75
64 5 64.
56 5 56. 63.5 63.5
20
53
- 23 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 24
Rotary Disconnects Overall dimensions (mm) front trim plates Hole layout Side view
48
37
Base mounting
32
32
48
10
28*
YNUT4 YNUY6
Recor mounting
19
Front view
32
Version
3.7
3.7
67 39
YNUT6 YNUY6
67
3.7
32
67
YNUK6 YNUL6
32
10
39
19
67
36
28*
38
32
67
39
82
YNUT7 YNUY7
32
82
YNUK7 YNUL7
* On request only for KNZ-XNF series
- 24 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
32
19
36
48
39
10
67
28*
32
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 25
Rotary Disconnects KNZ - Technical data Rated insulation voltage
Ui
Rated impulse withstand voltageUimp
Rated thermal current
Rated operational current
Max ratings for application on-phase motors
Free air
Uimp Ith
KNZ30
V
690
690
KNZ40 690
UL/CSA
V
-
600
600
CEE24
V
IEC947-3
kV
6
6
6 40
IEC947-3
A
25
32
UL/CSA
A
-
30
40
A
25
32
40 40
Enclosed
Ithe
IEC947-3
Category AC21A
Ie
IEC947-3
690 V
A
20
30
Category AC22A
Ie
IEC947-3
690 V
A
16
32
32
IEC947-3
230 V
kW
5.5 (22)
7.5 (24)
10 (31)
400 V
kW
9 (18)
12 (20)
18.5 (33)
500 V
kW
9 (14)
11 (16)
22 (32)
690 V
kW
11 (14)
15 (16)
22 (23)
230 V
kW
4 (16)
6 (17)
9 (27)
400 V
kW
7.5 (18)
9.5 (15)
17 (27)
500 V
kW
7.5 (12)
9.5 (14)
19 (28)
690 V
kW
9 (10)
11.5 (12)
22 (24)
A
-
-
-
2
3
5
Category AC23A
Category AC3
IEC947-3
Resistive load (motor load) Standard motor load
KNZ16 IEC947-3
CEE24 3-phase / 3-pole
1-phase / 2-pole
Rated short-time withstand current (1s)
UL/CSA
UL/CSA
120 V
120 V
HP 240 V
HP
5
7.5
10
480 V
HP
7.5
10
15
600 V
HP
7.5
10
15
HP
-
2
2
240 V
HP
-
3
3
A
600
600
800
Icw
Short-circuit protection: Rated conditional short-circuit current
IEC947-3
With fuse type gG
500 V
Rated short-circuit making capacity
Icm
Rated breaing capacity in category AC23 (cos 0.45)
kAeff
10
10
10
A
16
16
32
A
1500
1500
IEC947-3 IEC947-3
Average power dissipation for each pole
2000
230 V
A
184
184
248
400 V
A
160
160
264
W
1.1
1.6
B6
B6
B6
mm2
1.5-16
1.5-16
1.5-16
Connection capacity: Terminal gauge
IEC947-1
Rigid cables
min-max
Flexible cables
min-max
AWG
16-6
16-6
16-6
mm2
1.5-10
1.5-10
1.5-10
AWG
16-8
16-8
16-8
Normal service conditions Air ambient temperature
Resistance to climate
storage
°C
-30 - +70
operational
°C
-25 - +55
constant hot-damp climate, according to IEC 68 Part:
2-8
cyclic hot-damp climate, according to IEC 68 Part:
2-30
Auxiliary contacts Rated insulation voltage
Ui
IEC947-3
V
Rated thermal current
Ith
IEC947-3
A
Category AC15
Rated operational current
Category AC21A
Ie
IEC947-5
230 V
A
IEC947-3
690 V
A
- 25 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 26
Rotary Disconnects XNA/XNF - Technical data Rated insulation voltage
Ui
Rated impulse withstand voltageUimp
Rated thermal current
Rated operational current
Max ratings for application on 3-phase motors
Free air
Uimp Ith
XNA25
V
690
690
XNA32 690
UL/CSA
V
600
-
600
CEE24
V 6
IEC947-3
kV
6
6
IEC947-3
A
25
32
40
UL/CSA
A
20
-
40
Enclosed
Ithe
IEC947-3
A
16
25
32
Category AC21A
Ie
IEC947-3
690 V
A
20
25
40
Category AC22A
Ie
IEC947-3
690 V
A
16
25
32
IEC947-3
230 V
kW
7,5
9
10
400 V
kW
13
15
18,5
500 V
kW
13
15
18,5
690 V
kW
15
18,5
22
230 V
kW
6
7,5
9
400 V
kW
10
13
15
500 V
kW
10
13
15
690 V
kW
12
15
18,5 32(10)
Category AC23A
Category AC3
Resistive load (motor load) Standard motor load
XNA16 IEC947-3
IEC947-3
CEE24 3-phase / 3-pole
1-phase / 2-pole
UL/CSA
UL/CSA
120 V
A
20(8)
-
HP
2
3
5
240 V
HP
5
7,5
10
480 V
HP
10
10
15
600 V
HP
10
15
15
1,5
-
3
HP
2
-
5
A
400
800
800
kAeff
10
10
10
A
16
25
32
A
1500
2000
2000
230 V
A
184
240
240
400 V
A
192
264
264
0,9
1,6
-
120 V
HP 240 V
Rated short-time withstand current (1s)
Icw
Protezione contro cortocircuiti - Short-circuit protection: Rated conditional short-circuit current
IEC947-3
With fuse type gG
500 V
Rated short-circuit making capacity
Icm
Rated breaking capacity in category AC23 (cos 0.45)
IEC947-3 IEC947-3
Contatto - Average power dissipation for each pole Connection capacity: Terminal gauge
IEC947-1
B6
B6
B6
Rigid cables
min-max
1,5-16
1,5-16
1,5-16
Flexible cables
min-max
AWG
16-6
16-6
16-6
mm2
1,5-10
1,5-10
1,5-10
AWG
16-8
16-8
16-8
Normal service conditions Air ambient temperature
Resistance to climate
di stoccaggio/storage
°C
di funzionamento/operational
°C
constant hot-damp climate, according to IEC 68 Part: cyclic hot-damp climate, according to IEC 68 Part:
Auxiliary contacts Rated insulation voltage
Ui
IEC947-3
V
Rated thermal current
Ith
IEC947-3
A
XC16AN XC16CN
XC25AN XC25CN
XC32AN XC32CN
Ie
IEC947-5
230 V
A
690
690
690
IEC947-3
690 V
A
20
32
40
6
6
6
20
25
40
Category AC15
Rated operational current
Category AC21A
- 26 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
RD&CS b&W 28p.qk
3/27/02
3:29 PM
Page 27
XNA050
XNA063
XNA080
XNA100
XNF16
XNF32
690
690
690
690
690
690
-
600
600
600
-
-
-
-
-
-
-
-
6
6
6
6
6
6
50
63
80
100
16
32
-
80
100
100
-
-
50
63
80
80
16
16
50
63
80
100
16
16
50
63
80
80
16
16
11
15
18,5
22
7,5
10
22
25
30
35
13
18,5
22
30
37
45
13
18,5
18,5
18,5
22
30
15
22
11
11
15
18,5
6
9
18,5
18,5
22
30
10
15
18,5
22
30
37
10
15
15
15
18,5
22
12
18,5
-
-
-
-
-
-
-
-
-
-
-
-
-
20
25
25
-
-
-
30
40
50
-
-
-
30
50
50
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1500
1500
1500
1500
400
800
15
15
15
15
10
10
50
63
80
100
16
32
2000
2000
2500
2500
-
-
376
376
560
560
184
240
376
376
504
504
192
264
-
-
-
-
1,8
3,5
B9
B9
B9
B9
B6
B6
10-50
10-50
10-50
10-50
1,5-10
1,5-10
8-1
8-1
8-1
8-1
16-8
16-8
6-35
6-35
6-35
6-35
1,5-16
1,5-16
16-8
10-1
10-1
10-1
16-6
16-6
-30÷+70
-30÷+70
-30÷+70
-25÷+55
-25÷+55
-25÷+55
2-3
2-3
2-3
2-30
2-30
2-30
XC012AB XC012CB
XNF16
XNF32
690
690
690
12
20
40
6
6
6
-
20
40
- 27 -
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]