Preview only show first 10 pages with watermark. For full document please download

Rotarydisconnectsc

   EMBED


Share

Transcript

RD&CS b&W 28p.qk 3/27/02 12:32 PM Page 13 KNZ/XNA/XNF - Rotary Disconnects KNZ/XNA/XNF Series ● Pillar-type connection ● Two, three or four pole versions available ● Wiring terminals with IP20 finger safe protection against accidental contact ● Screws provided with captive self-lifting cable clamps, which are supplied in open position, for quick and easy wiring ● Positively-opening double-break contacts, made of silver alloy KNZ (non-expandable) ● 16, 30 or 40 Amp rating XNA XNF With fuses (expandable) ● 16, 25 or 32 Amp rating (expandable) ● 16, 25, 32, 50, 63, 80 or 100 Amp rating XNA and XNF Expandable with additional pole(s) or auxiliary contact block(s) or Pending ● When ordering, specify Catalog Number of the disconnect along with the Catalog Number of the front trim plate, because these two products are supplied separately. The standard operating shaft is supplied with the disconnect. ● New modular and shaft extensions ● Available with fast Ø22mm rear mounting ● IP65 rated operating handle - 13 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 12:38 PM Page 14 Rotary Disconnects Front Trim Plates Emergency Switches Switches With Legend With Legend Emergency Switches with Lockout Switches with Lockout With Legend With Legend Additional Pole(s) and Auxiliary Contact Block(s) For Rear Mounting and Ø22mm Rear Mounting Types For Base Mounting Types PE PE 1NC o 1NO auxiliary contact 1NC o 1NO auxiliary contact Additional Pole Additional Pole Additional Pole Additional Pole 1NC o 1NO auxiliary contact 1NC o 1NO auxiliary contact Max 2 on each side PE Max 2 on each side PE Rotary Disconnects Mounted in Non-metallic IP65 Enclosures Three or Four Pole Emergency Disconnects Three or Four Pole Disconnects With Lockout With Lockout - 14 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 12:45 PM Page 15 Rotary Disconnects Housing rear mounting KNZ - Housing 2 pole Catalog no. BR511000 BR513700 BR516400 Type KNZ16R2000 KNZ30R2000 KNZ40R2000 3 pole Catalog no. BR511300 BR51400 BR516700 Type KNZ16R3000 KNZ30R3000 KNZ40R3000 4 pole Catalog no. BR511600 BR514300 BR517000 Type KNZ16R4000 KNZ30R4000 KNZ40R4000 Ith 16 A 32 A 40 A XNA - Housing 2 pole Catalog no. BR519100 BR523500 BR528400 XNF - Type XNA162R XNA252R XNA322R Catalog no. BR521200 BR5125400 BR530500 Type XNA163R XNA253R XNA323R 4 pole Catalog no. BR523300 BR527500 BR532600 Type XNA164R XNA254R XNA324R Ith 16 A 25 A 32 A Housing with fuses 2 pole Catalog no. BR533300 BR535600 3 pole Type XNF162R XNF322R 3 pole Catalog no. BR533900 BR536500 Type XNF163R XNF323R 4 pole Catalog no. BR534700 BR537400 Type XNF164R XNF324R Ith 16 A 32 A Housing base mounting KNZ - Housing 2 pole Catalog no. BR509200 BR511900 BR514600 Type KNZ16B2000 KNZ30B2000 KNZ40B2000 3 pole Catalog no. BR509500 BR512200 BR514900 Type KNZ16B3000 KNZ30B3000 KNZ40B3000 4 pole Catalog no. BR509800 BR512500 BR515200 Type KNZ16B4000 KNZ30B4000 KNZ40B4000 Ith 16 A 32 A 40 A XNA - Housing 2 pole Catalog no. BR518500 BR523400 BR527800 - Type XNA162B XNA252B XNA322B 3 pole Catalog no. BR526600 BR524800 BR529900 BR517300 BR517600 BR517900 BR518200 Type XNA163B XNA253B XNA323B XNA0503B XNA0633B XNA0803B XNA1003B 4 pole Catalog no. BR522700 BR526900 BR532000 Type XNA164B XNA254B XNA324B Ith 16 A 25 A 32 A 50 A 63 A 80 A 100 A XNF - Housing with fuses 2 pole Catalog no. BR509200 BR535000 Type XNF162B XNF322B 3 pole Catalog no. BR533500 BR535900 Type XNF163B XNF323B 4 pole Catalog no. BR534100 BR536800 Type XNF164B XNF324B - 15 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] Ith 16 A 32 A RD&CS b&W 28p.qk 3/27/02 1:03 PM Page 16 Rotary Disconnects Front trim plates rear and base mounting to screw KNZ - XNA - XNF Series IP65 Switch whith grey plate and black handle Catalog no. BR540700 BR541000 Type YNUT4 YNUT6 KNZ - XNA - XNF KNZ - XNA - XNF SeriesI P65 Switch whith grey anodized plate and black handle with legend label carrier Plate dimensions 48x48 67x67 Series IP65 Catalog no. BR541300 Type YNUT7 KNZ - XNA - XNF Plate dimensions 67x82 Series IP65 Emergency-off switch with yellow plate and red handle. Emergency-off switch with yellow plate and red handle with legend label carrier Catalog no. BR541600 BR541900 Catalog no. BR542200 Type YNUY4 YNUY6 KNZ - XNA - XNF Plate dimensions 48x48 67x67 Series IP65 Type YNUY7 KNZ - XNA - XNF Plate dimensions 67x82 Series IP65 Emergency-off main switch with padlock facility in 0 position, yellow plate and red handle. Emergency-off main switch with padlock facility in 0 position, yellow plate and red handle with legend label carrier Catalog no. BR540100 Catalog no. BR540400 Type YNUL6 Plate dimensions 67x67 KNZ - XNA - XNF Series Type YNUL7 Plate dimensions 67x82 KNZ - XNA - XNF Series IP65 IP65 Main switch with padlock facility in 0 position, grey plate and black handle. Main switch with padlock facility in 0 position, grey plate and black handle with legend label carrier Catalog no. BR539500 Catalog no. BR539800 Type YNUK6 Plate dimensions 67x67 Type YNUK7 Plate dimensions 67x82 - 16 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 1:07 PM Page 17 Rotary Disconnects Housing center rear mounting Ø 22 KNZ - Hhousing 2 pole Catalog no. Type BR510100 KNZ16G2000 BR512800 KNZ30G2000 BR51…00 KNZ40G2000 3 pole Catalog no. Type BR510400 KNZ16G3000 BR513100 KNZ30G3000 BR51…00 KNZ40G3000 4 pole Catalog no. Type BR510700 KNZ16G4000 BR513400 KNZ30G4000 BR51…00 KNZ40G4000 Ith 16 A 32 A 40 A 3 pole Catalog no. Type BR520900 XNA163G BR525100 XNA253G BR530200 XNA323G 4 pole Catalog no. Type BR523000 XNA164G BR527200 XNA254G BR532300 XNA324G Ith 16 A 25 A 32 A 3 pole Catalog no. Type BR533800 XNF163G BR536200 XNF323G 4 pole Catalog no. Type BR534400 XNF164G BR537100 XNF324G Ith 16 A 32 A XNA - Housing 2 pole Catalog no. Type BR518800 XNA162G BR51…00 XNA252G BR528400 XNA322G XNF - Housing with fuses 2 pole Catalog no. Type BR533200 XNF162G BR535300 XNF322G Front trim plates center rear mounting Ø 22 KNZ - XNA - XNF Series KNZ - XNA - XNF IP65 Switch whith grey plate and black handle Catalog no. BR538300 BR538600 Type YNGT4 YNGT6 KNZ - XNA - XNF P65 Emergency-off switch with yellow plate and red handle. Plate dimensions 48x48 67x67 Series SeriesI IP65 Catalog no. BR538900 BR539200 Type YNGY4 YNGY6 Plate dimensions 48x48 67x67 KNZ - XNA - XNF IP65 Emergency-off main switch with padlock facility in 0 position, yellow plate and red handle. Main switch with padlock facility in 0 position, grey plate and black handle with legend label carrier Catalog no. BR53800 Catalog no. BR537700 Type YNGL6 Plate dimensions 67x67 Type YNGK6 Plate dimensions 67x67 - 17 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:16 PM Page 18 Rotary Disconnects Accessories Shaft extensions • Allows adapting the switches with door interlocking device to the different mounting lengths 1 type length BR508300 B - GNAPO 100 mm BR508600 B - GNAP1 150 mm BR508900 B - GNAP2 200 mm 2 181 H=100m 3 194 + 206 191 203 215 231 244 256 241 253 265 min 281 294 306 max 291 303 315 L code H=150m H=200mm + 12.2 + 12.2 + 12.2 1 2 3 + 216 232 248 225 242 258 266 282 298 275 292 308 316 332 348 325 342 358 + 16.2 + 16.2 + 16.2 Modular extensions • Allows adapting the switches whith door interlocking device to the different mounting lengths • Includes 4 forms that overlap max 4 3 2 L=(mm) 1 2 3 + 101 114 126 111 123 126 1139 136 148 min 151 max min max 2 3 + 127 143 135 120 137 153 151 136 152 168 160 145 162 178 164 176 161 177 193 161 173 185 170 187 203 176 189 201 186 202 218 186 198 210 195 212 228 + 16.2 L 1 1 111 + 12.2 catalog no type BR508000 B - GNAMO length - 3 3 + 12.2 + 12.2 + 12.2 + 16.2 + 16.2 + 16.2 Plate for base mounting (base mounting) Black label - red label for engraving blank KNZ 16÷40 A • For front trim plates with legend label carrier catalog no type VC218600 B-KG6047 y x catalog no type length BR506800 B - 6429 - Protection shrounds for terminals • Allow increasing the degree of protection of the connection termunals. XNA 50÷100 A KNZ 16÷40 A catalogo n. type Terminal cover descriptional VD456100 B-G1305 3 pole catalog no. VC211100 type B-G1280 Terminal cover descriptional * The catalog No. includes the upper and lower cover 3- 4 pole * The catalog No. includes the upper and lower cover XNA 50÷100 A XNA-XNF 16÷32 A catalog no type Terminal cover descriptional VC286300 B-G813 3- 4 pole catalogo n. type Terminal cover descriptional VD457900 B-G1304 1 pole * The catalog No. includes the upper and lower cover * The catalog No. includes the upper and lower cover - 18 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:18 PM Page 19 Rotary Disconnects Additional pole and auxiliary contact block for rear mounting and ø 22 mm PE XNA - XNF 1NC o 1NO auxiliary contact Auxiliary contact unit and additional pole for series XNA - XNF Additional Pole Catalog no. VC300200 VC301000 VC296200 VC297000 VC302800 VC303600 VC304400 Additional Pole 1NC o 1NO auxiliary contact PE Max 2 on each side Type XC16AN XC16CN XC25AN XC25CN XC32AN XC32CN XC32GN Ith 16 A 16 A 25 A 25 A 32 A 32 A 16-25-32 A Contact features 1NO 1NC 1NO 1NC 1NO 1NC PE Ith 16 A 16 A 25 A 25 A 32 A 32 A 16-25-32 A Contact features 1NO 1NC 1NO 1NC 1NO 1NC PE Ith 50-63-80-100A 50-63-80-100 A 50-63-80-100 A 50 A 63 A 80 A 100 A Contact features 1NO 1NC PE N N N N Additional pole and auxiliary contact block for base mounting XNA - XNF PE Auxiliary contact unit and additional pole for series XNA - XNF 1NC o 1NO auxiliary contact Additional Pole Additional Pole 1NC o 1NO auxiliary contact Catalog no. VC301000 VC300200 VC297000 VC296200 VC303600 VC302800 VC304400 Type XC16CN XC16AN XC25CN XC25AN XC32CN XC32AN XC32GN Catalog no. VD459500 VD460300 VD455300 VD298800 VD452000 VD453800 VD454600 Type XC012AB XC012CB XC100GB XC050PB XC063PB XC080PB XC100PB PE Max 2 on each side 1NC auxiliary contact 1NO auxiliary contact PE 4th pole 1NO auxiliary contact Max 1 on each side 1NC auxiliary contact Auxiliary contact NA Auxiliary contact NC Earth PE Fourth pole N 3 1 PE N 4 2 PE N - 19 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 20 Rotary Disconnects Surface mounting XNA…BXP IP65 Switch fitted in insulated enclosure and provided with grey front trim plate and black handle 3 pole Catalog no. BR520300 BR524500 BR529600 4 pole Type XNA1630BXP XNA2530BXP XNA3230BXP Catalog no. BR511300 BR526600 BR531700 Type XNA1640BXP XNA2540BXP XNA3240BXP XNA…BXG Ith 16 A 25 A 32 A IP65 Emergency-off switch fitted in insulated enclosure and provided with yellow front trim plate and red handle 3 pole Catalog no. BR519400 BR523600 BR529700 4 pole Type XNA1630BXG XNA2530BXG XNA3230BXG Catalog no. BR521500 BR525700 BR530800 Type XNA1640BXG XNA2540BXG XNA3240BXG XNA…BXL Ith 16 A 25 A 32 A IP65 Main switch fitted in insulated enclosure and provided padlock facility in 0 position;yellow front trim plate and red handle pole Catalog no. BR519700 BR523900 BR529000 4 pole Type XNA1630BXL XNA2530BXL XNA3230BXL Catalog no. BR521800 BR526000 BR531100 Type XNA1640BXL XNA2540BXL XNA3240BXL XNA…BXN Ith 16 A 25 A 32 A IP65 Emergency-off main switch fitted in insulated enclosure and provided with padlock facility in 0 position,grey front trim plate and black handle 3 pole Catalog no. BR512000 BR524200 BR529300 4 pole Type XNA1630BXN XNA2530BXN XNA3230BXN Catalog no. BR522100 BR526300 BR531400 Type XNA1640BXN XNA2540BXN XNA3240BXN - 20 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] Ith 16 A 25 A 32 A RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 21 Rotary Disconnects Diagrams KNZ XNA (30-400 A) (16-32 A) KNZ XNA (16-30-40 A) (16- 100 A) KNZ XNA (16-30-40 A)(16-25-32 A) XNA (50÷100 A) 2 - pole 3 - pole 4 - pole 6 - pole L1 N L1 L2 L3 L1 L2 L3 N L1 L2 L3 N T1 N T1 T2 T3 T1 T2 T3 N T1 T2 T3 N Overall dimensions (mm) of housing base mounting Version Front view Side view 83 ÷ 93 7.3 55.5 L L1 L L2 L3 N T1 T2 T3 N 47 KNZ (16-30-40A) 5 45.5 70 83÷93 XNA (16-32A) 67.5 28.5 4.2 7.3 5 64.5 48 97÷107 60 60 1 L1 3 L2 5 L3 2 T1 4 T2 6 T3 68 80 XNA (50*100) 90 7.3 5.2 23.5 25 6.5 43.5 - 21 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 22 Rotary Disconnects Overall dimensions (mm) of housing base mounting Front view Side view 83÷93 72.5 48 70 64.5 36.5 DIN 46277/3 Ø15 4.2 28.5 XNF…B (16 A) 33.75 7.3 99.5 Version 15 5 58 75.5 83÷93 70 48 64.5 55.25 24 19.5 65 121.5 33.75 DIN 46277/3 4.2 XNF…B (32 A) 28.5 28.5 7.3 56.5 5 63.5 20 Overall dimensions (mm) XC16CN XC16AN XC25CN XC25AN XC32CN XC32AN XC32GN XC012AB XCO12CB XC100GB XC050PB XC063PB XC080PB XC100PB B-KG6047 - 22 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 23 Rotary Disconnects Overall dimensions (mm) of housing rear mounting Version Front view Side view 55.5 53 32 KNZ..R (16-30-40A) 10 47 KNZ..G (16-30-40A) M. 3.5 70 10 67.5 2.2 XNA..R XNF..R (16-32A) XNA..G (16-32A) 28.5 4.2 53 32 64.5 72.5 63 70 Ø15 4.2 99.5 28.5 XNF..R/G (16 A) 36.5 33.75 64.5 15 58 53 75 5 75. 63 48 121.5 19.5 4.2 65 XNF..R/G (32A) 55.25 28.5 33.75 64 5 64. 56 5 56. 63.5 63.5 20 53 - 23 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 24 Rotary Disconnects Overall dimensions (mm) front trim plates Hole layout Side view 48 37 Base mounting 32 32 48 10 28* YNUT4 YNUY6 Recor mounting 19 Front view 32 Version 3.7 3.7 67 39 YNUT6 YNUY6 67 3.7 32 67 YNUK6 YNUL6 32 10 39 19 67 36 28* 38 32 67 39 82 YNUT7 YNUY7 32 82 YNUK7 YNUL7 * On request only for KNZ-XNF series - 24 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] 32 19 36 48 39 10 67 28* 32 RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 25 Rotary Disconnects KNZ - Technical data Rated insulation voltage Ui Rated impulse withstand voltageUimp Rated thermal current Rated operational current Max ratings for application on-phase motors Free air Uimp Ith KNZ30 V 690 690 KNZ40 690 UL/CSA V - 600 600 CEE24 V IEC947-3 kV 6 6 6 40 IEC947-3 A 25 32 UL/CSA A - 30 40 A 25 32 40 40 Enclosed Ithe IEC947-3 Category AC21A Ie IEC947-3 690 V A 20 30 Category AC22A Ie IEC947-3 690 V A 16 32 32 IEC947-3 230 V kW 5.5 (22) 7.5 (24) 10 (31) 400 V kW 9 (18) 12 (20) 18.5 (33) 500 V kW 9 (14) 11 (16) 22 (32) 690 V kW 11 (14) 15 (16) 22 (23) 230 V kW 4 (16) 6 (17) 9 (27) 400 V kW 7.5 (18) 9.5 (15) 17 (27) 500 V kW 7.5 (12) 9.5 (14) 19 (28) 690 V kW 9 (10) 11.5 (12) 22 (24) A - - - 2 3 5 Category AC23A Category AC3 IEC947-3 Resistive load (motor load) Standard motor load KNZ16 IEC947-3 CEE24 3-phase / 3-pole 1-phase / 2-pole Rated short-time withstand current (1s) UL/CSA UL/CSA 120 V 120 V HP 240 V HP 5 7.5 10 480 V HP 7.5 10 15 600 V HP 7.5 10 15 HP - 2 2 240 V HP - 3 3 A 600 600 800 Icw Short-circuit protection: Rated conditional short-circuit current IEC947-3 With fuse type gG 500 V Rated short-circuit making capacity Icm Rated breaing capacity in category AC23 (cos 0.45) kAeff 10 10 10 A 16 16 32 A 1500 1500 IEC947-3 IEC947-3 Average power dissipation for each pole 2000 230 V A 184 184 248 400 V A 160 160 264 W 1.1 1.6 B6 B6 B6 mm2 1.5-16 1.5-16 1.5-16 Connection capacity: Terminal gauge IEC947-1 Rigid cables min-max Flexible cables min-max AWG 16-6 16-6 16-6 mm2 1.5-10 1.5-10 1.5-10 AWG 16-8 16-8 16-8 Normal service conditions Air ambient temperature Resistance to climate storage °C -30 - +70 operational °C -25 - +55 constant hot-damp climate, according to IEC 68 Part: 2-8 cyclic hot-damp climate, according to IEC 68 Part: 2-30 Auxiliary contacts Rated insulation voltage Ui IEC947-3 V Rated thermal current Ith IEC947-3 A Category AC15 Rated operational current Category AC21A Ie IEC947-5 230 V A IEC947-3 690 V A - 25 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 26 Rotary Disconnects XNA/XNF - Technical data Rated insulation voltage Ui Rated impulse withstand voltageUimp Rated thermal current Rated operational current Max ratings for application on 3-phase motors Free air Uimp Ith XNA25 V 690 690 XNA32 690 UL/CSA V 600 - 600 CEE24 V 6 IEC947-3 kV 6 6 IEC947-3 A 25 32 40 UL/CSA A 20 - 40 Enclosed Ithe IEC947-3 A 16 25 32 Category AC21A Ie IEC947-3 690 V A 20 25 40 Category AC22A Ie IEC947-3 690 V A 16 25 32 IEC947-3 230 V kW 7,5 9 10 400 V kW 13 15 18,5 500 V kW 13 15 18,5 690 V kW 15 18,5 22 230 V kW 6 7,5 9 400 V kW 10 13 15 500 V kW 10 13 15 690 V kW 12 15 18,5 32(10) Category AC23A Category AC3 Resistive load (motor load) Standard motor load XNA16 IEC947-3 IEC947-3 CEE24 3-phase / 3-pole 1-phase / 2-pole UL/CSA UL/CSA 120 V A 20(8) - HP 2 3 5 240 V HP 5 7,5 10 480 V HP 10 10 15 600 V HP 10 15 15 1,5 - 3 HP 2 - 5 A 400 800 800 kAeff 10 10 10 A 16 25 32 A 1500 2000 2000 230 V A 184 240 240 400 V A 192 264 264 0,9 1,6 - 120 V HP 240 V Rated short-time withstand current (1s) Icw Protezione contro cortocircuiti - Short-circuit protection: Rated conditional short-circuit current IEC947-3 With fuse type gG 500 V Rated short-circuit making capacity Icm Rated breaking capacity in category AC23 (cos 0.45) IEC947-3 IEC947-3 Contatto - Average power dissipation for each pole Connection capacity: Terminal gauge IEC947-1 B6 B6 B6 Rigid cables min-max 1,5-16 1,5-16 1,5-16 Flexible cables min-max AWG 16-6 16-6 16-6 mm2 1,5-10 1,5-10 1,5-10 AWG 16-8 16-8 16-8 Normal service conditions Air ambient temperature Resistance to climate di stoccaggio/storage °C di funzionamento/operational °C constant hot-damp climate, according to IEC 68 Part: cyclic hot-damp climate, according to IEC 68 Part: Auxiliary contacts Rated insulation voltage Ui IEC947-3 V Rated thermal current Ith IEC947-3 A XC16AN XC16CN XC25AN XC25CN XC32AN XC32CN Ie IEC947-5 230 V A 690 690 690 IEC947-3 690 V A 20 32 40 6 6 6 20 25 40 Category AC15 Rated operational current Category AC21A - 26 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] RD&CS b&W 28p.qk 3/27/02 3:29 PM Page 27 XNA050 XNA063 XNA080 XNA100 XNF16 XNF32 690 690 690 690 690 690 - 600 600 600 - - - - - - - - 6 6 6 6 6 6 50 63 80 100 16 32 - 80 100 100 - - 50 63 80 80 16 16 50 63 80 100 16 16 50 63 80 80 16 16 11 15 18,5 22 7,5 10 22 25 30 35 13 18,5 22 30 37 45 13 18,5 18,5 18,5 22 30 15 22 11 11 15 18,5 6 9 18,5 18,5 22 30 10 15 18,5 22 30 37 10 15 15 15 18,5 22 12 18,5 - - - - - - - - - - - - - 20 25 25 - - - 30 40 50 - - - 30 50 50 - - - - - - - - - - - - - - 1500 1500 1500 1500 400 800 15 15 15 15 10 10 50 63 80 100 16 32 2000 2000 2500 2500 - - 376 376 560 560 184 240 376 376 504 504 192 264 - - - - 1,8 3,5 B9 B9 B9 B9 B6 B6 10-50 10-50 10-50 10-50 1,5-10 1,5-10 8-1 8-1 8-1 8-1 16-8 16-8 6-35 6-35 6-35 6-35 1,5-16 1,5-16 16-8 10-1 10-1 10-1 16-6 16-6 -30÷+70 -30÷+70 -30÷+70 -25÷+55 -25÷+55 -25÷+55 2-3 2-3 2-3 2-30 2-30 2-30 XC012AB XC012CB XNF16 XNF32 690 690 690 12 20 40 6 6 6 - 20 40 - 27 - Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]