Preview only show first 10 pages with watermark. For full document please download

Rotavapor R-210 / R-215 Technical Data Sheet

   EMBED


Share

Transcript

Rotavapor ® R-210 / R-215 Technical data sheet The evaporation of solvents is a routine process widely performed in the laboratory. It is therefore important that the instruments optimally support the user’s working methods and match to the conditions and needs of the laboratory. Scope of delivery All models are delivered ready to use and are complete of: Components System with glass System w/o glass Rotavapor® (according to order code) 1 1 Heating bath 1 (1) Condenser (according to order code) 1 - Vapor duct (with Combi-Clip) 1 - Vacuum seal (WD26) 1 - Evaporating flask (1 liter) 1 - Receiving flask (1 liter) 1 - Flyer "List of solvents" 1 1 Flask holder 1 1 Vapor temperature sensor (1)* - Stage probe ( 1 ) ** - *  Only delivered if R-215 system is ordered with glass assembly V, S, E or BY ** Only delivered if system is ordered with Vacuum Controller V-855 and glass assemly V or S 2 Order code Choose the configuration according to your needs: Systems with glass 2 Rotavapor R-210 / R-215 0 R-210 without display 1 R-215 with display for rotation speed and vapor temperature 2 R-210 without heating bath *** 3 R-215 without heating bath *** 3 Voltage options 1 220 - 240 V *** 2 100 - 120 V Joint options for evaporating flask 1 SJ 29/32 2 SJ 24/40 3 SJ 29/42 Vacuum controller 0 Without controller 1 Vacuum Controller V-850 2 Vacuum Controller V-855 Valve unit 0 Without valve unit 1 Woulff bottle for vacuum controller (needed for stand-alone system with V-700) 2 Valve unit for vacuum controller (not necessary in stand-alone system with V-700) Glass assembly options A Glass assembly A V Glass assembly V */** C Glass assembly C S Glass assembly S */** E Glass assembly E * R Glass assembly CR Y Glass assembly BY P+G 0 Without coating 1 With safety coating * Vapor temperature measurement possible ** Auto-distillation possible *** The Rotavapor without the heating bath supports the whole voltage range of 100 - 240 V. Therefore when ordering a system without heating bath the voltage option 100 - 120 V needs to be chosen Systems without glass 2 3 0 2 0 N 0 0 0 R-210 with bath, w/o glass, 100 - 120 V 2 3 0 1 0 N 0 0 0 R-210 with bath, w/o glass, 220 - 240 V 2 3 2 0 0 N 0 0 0 R-210 w/o bath, w/o glass, 100 - 240 V 2 3 1 2 0 N 0 0 0 R-215 with bath, w/o glass, 100 - 120 V 2 3 1 1 0 N 0 0 0 R-215 with bath, w/o glass, 220 - 240 V 2 3 3 0 0 N 0 0 0 R-215 w/o bath, w/o glass, 100 - 240 V 3 Order code for Rotavapor systems with vacuum pump, vacuum controller and optional recirculating chiller. 2 3 1 Rotavapor R-210 / R-215 0 R-210 without display 1 R-215 with display for rotation speed and  vapor temperature Voltage options 1 220 - 240 V 2 100 - 120 V Vacuum controller 1 Vacuum Controller V-850 2 Vacuum Controller V-855 (for automatic distillation) Vacuum pump options 1 Vacuum Pump V-700 (1.8 m3/h, <10 mbar) 2 Vacuum Pump V-700 with secondary condenser 4 Vacuum Pump V-710 (3.1 m3/h, 2 mbar) 5 Vacuum Pump V-710 with secondary condenser Joint options for evaporating flask 1 SJ 29/32 2 SJ 24/40 Glass assembly options A Glass assembly A V Glass assembly V */** C Glass assembly C S Glass assembly S */** P+G 0 Without coating 1 With safety coating Recirculating chiller 0 Without recirculating chiller 1 Recirculating Chiller F-100 (fix 10 °C, 500 W) 2 Recirculating Chiller F-105 (-10 °C to 25 °C, 500 W) 3 Recirculating Chiller F-108 (-10 °C to 25 °C, 800 W) * When ordering with V-855, the stage probe is included ** When ordering with a R-215, the vapor temperature sensor is included 4 Description of glass assemblies Abbr. Type / Application Cooling surface area V Vertical condenser 0.146 m2 For standard applications. The most common condenser and in combination with an R-215 this glass assembly is equipped with a vapor temperature sensor. C Dry ice condenser (cold trap) 0.05 m2 For distillation of solvents with low boiling points. No cooling water is necessary. A Diagonal condenser 0.146 m2 For standard applications where height is limited. S Vertical reflux condenser with shut-off valve 0.146 m2 For distillation under reflux. In combination with an R-215 this glass assembly is equipped with a vapor temperature sensor. CR Dry ice reflux condenser with shut-off valve 0.05 m2 For distillation under reflux of solvents with low boiling points. No cooling water is needed. E Descending condenser with expansion vessel 0.148 m2 For foaming and bumping products. In combination with an R-215, this glass assembly is equipped with a vapor temperature sensor. BY Double jacket vertical reflux condenser with shut-off valve 0.125 m2 For distillation and reflux operation. There is an additional SJ 29/32 joint on top for flexible expansion. In combination with an R-215, this glass assembly is equipped with a vapor temperature sensor. Dimensions Dimension (WxHxD) Rotavapor R-210 / R-215 with V-condenser 590 x 840 x 420 mm Rotavapor R-210 / R-215 w/o condenser 550 x 575 x 420 mm Technical data Rotavapor ® R-210 Rotavapor ® R-215 Weight (depending on glass assembly) 16 - 18 kg 16 - 18 kg Operating voltage 100 - 240 V 100 - 240 V Frequency 50/60 Hz 50/60 Hz Power consumption 60 W 60 W IP class 21 21 Angle adjustable 0 - 25 ° 0 - 25 ° Stroke distance 145 mm 145 mm Rotation speed 20 - 280 rpm 20 - 280 rpm 5 Rotavapor ® R-210 Rotavapor ® R-215 Flask size range * 50 - 4000 mL 50 - 4000 mL Maximum flask capacity 3 kg 3 kg Display None Rotation speed and vapor temperature Approval CE / CSA CE / CSA Heating Bath B-491 Heating Bath B-495 Dimension (WxHxD) 285 x 240 x 300 mm 310 x 230 x 320 mm Weight 4 kg 5 kg Operating voltage 100 - 120 V or 220 - 240 V 100 - 120 V or 220 - 240 V Frequency 50/60 Hz 50/60 Hz Power consumption 1700 W 1700 W Heating power 1300 W 1300 W IP class 21 21 Controlled temperature range 20 - 180 °C (water and oil) 20 - 95 °C Digital display Set and actual temperature Set and actual temperature Kettle connector between bath base and heating bath Yes Yes Infrared communication Yes Yes Heating bath temperature lock Yes Yes Temperature deviation ± 2 °C ± 3 °C Max. flask size 4000 mL 5000 mL Approval CE / CSA CE / CSA * using Heating Bath B-491 Complementary products See respective product brochures, and technical data sheets for more information. Chiller F-100 Chiller F-105 Chiller F-108 Pump V-700 Pump V-710 Controller V-850 Controller V-855 R-210 / R-215 autonomous manually controlled manually controlled autonomous autonomous for pump/ chiller only for pump/ chiller only R-210 / R-215 with V-850 / V-855 autonomous controlled controlled controlled controlled - - 6 Exemplary solution The following items are listed based on two solutions, shown in the “Laboratory Evaporation Solutions“-brochure. Solution “Rotavapor ® Semi-Automated” Order number Rotavapor® R-210, V-condenser, SJ 29/32, P+G safety coating (220 - 240 V), Vacuum Controller V-850, Vacuum Pump V-700, Recirculating Chiller F-105 23011V11112 Safety shield 048052 Solution “Rotavapor ® Automated” Order number Rotavapor® R-215, V-condenser, SJ 29/32, auto-distillation (220 - 240 V), Vacuum Controller V-855, Vacuum Pump V-700, Recirculating Chiller F-105, stage probe (for auto-distillation) 23111V02112 Distillation Record software 051480 Rotavapor accessories Order number Manometer with needle valve 047291 For manual regulation of vacuum when using house vacuum. Includes holder Stop-position extension 044466 Extension of end-stop rod to stop the automatic lift at a higher level (for large flasks with the B-495) Flask holder 048618 Keeps the flask stable on the table, made of non-slipping EPDM Set flask holder, 5 pcs. 11059916 Keeps the flask stable on the table, made of non-slipping EPDM Vacuum seal WD26 048021 Low abrasion vacuum seal in PTFE composite material Laboratory grease Glisseal (blue) 048197 Tube 60 g Water jet pump unit B-764, 24 V 031358 Simple principle of vacuum generation, without cooling water valve, 24 V (1 magnetic valve and a FFKM backstroke valve). Only in combination with Vacuum Controller Water jet pump unit B-767, 24 V 031357 Simple principle of vacuum generation, with cooling water valve, 24 V (2 magnetic valve and a FFKM backstroke valve). Only in combination with Vacuum Controller Cooling water valve 031356 Save water as the vacuum controller opens the cooling water feed only during distillation, 24 V Standard stop-cock, SJ 18.8/38 040627 For aeration Classic stop-cock, SJ 18.8/38 000637 For aeration, less cross-contamination than standard stop-cock (040627). 7 Order number Stop-cock PTFE, SJ 18.8/38 023896 For applications where grease should be avoided. Used instead of standard stop- cock (040627). Condensor holder complete 048180 Fits glass assemblies V, C, S and CR Rotavapor heating bath For R-210 / R-215 Order number Heating Bath B-491, 20 – 180 °C, max. flask size 4000 mL Complete, including base with power supply 220 – 240 V 048200 100 – 120 V 048201 220 – 240 V (gold-coated) * 048277 Heating Bath B-495, 20 – 95 °C, max. flask size 5000 mL Complete, including base with power supply, bath replenishment 220 – 240 V 048240 100 – 120 V 048241 220 – 240 V (gold-coated) * 048246 For R-200 / R-205 Order number Heating Bath B-491, 20 – 180 °C, max. flask size 4000 mL Complete, including base with power supply 220 – 240 V 048212 100 – 120 V 048213 220 – 240 V (gold-coated) * 046585 Base plate for R-200 / R-205 Special platform adapter for Heating Bath B-491 and B-495 220 – 240 V 048358 100 – 120 V 048359 For R-114 Order number Heating Bath B-491, 20 – 180 °C, max. flask size 4000 mL Complete, including base with power supply 220 – 240 V 047374 100 – 120 V 047375 * The contacts on both sides of the kettle connector are gold coated which are especially resistant against corrosion found in very harsh environments Heating bath accessories Order number Protective shield for B-491 048052 Effective user protection against splashing and implosions Protective shield for B-495 048245 Effective user protection against splashing and implosions 8 Heating bath accessories Order number Top cover for heating bath B-491 048230 To cover bath with a lid when not in use to safe energy and less evaporation of heating medium Floating balls, 450 pcs. 036405 To reduce energy consumption of the heating bath (up to 100 °C, PP) and less evaporation of heating medium Rotavapor glass assemblies The following items only have to be ordered when system without glass is ordered. Order number Glass assembly V complete 040600 Includes receiving flask (1 liter), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly V complete P+G safety coating 040602 Includes receiving flask (1 liter, P+G safety coating), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly C complete 040640 Includes receiving flask (1 liter), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly C complete P+G safety coating 040642 Includes receiving flask (1 liter, P+G safety coating), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Cooling coil insert, replaces cold finger 027488 Includes the insert and the cold trap seal (PTFE-ring with 2 O-rings) and is used like a normal liquid-cooled condenser. Glass assembly A complete 048168 Includes receiving flask (1 liter), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly A complete P+G safety coating 048169 Includes receiving flask (1 liter, P+G safety coating), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly S complete 040650 Includes receiving flask (1 liter), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly S complete P+G safety coating 040652 Includes receiving flask (1 liter, P+G safety coating), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Soxhlet extraction unit, 200 mL 011744 For extractions in combination with glass assembly S Soxhlet extraction unit, 500 mL 011745 For extractions in combination with glass assembly S Extraction cartridges, 1 x 200 mL 008560 Extraction cartridges, 1 x 500 mL 000989 Extraction cartridges, 25 x 200 mL 018106 9 Order number Glass assembly CR complete P+G safety coating 040672 Includes receiving flask (1 liter, P+G safety coating), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly E complete 040660 Includes receiving flask (1 liter), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly E complete P+G safety coating 040662 Includes receiving flask (1 liter, P+G safety coating), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Glass assembly BY complete 048176 Includes receiving flask (1 liter), required hoses and ball joint clamp, does not include evaporating flask and vapor duct. Rotavapor glass accessories All vapor ducts include Combi-Clip Vapor duct compatible with WD26 SJ 29/32 SJ 24/40 SJ 29/42 SJ 34/35 Vapor duct for glass assembly A (285 mm) 048164 048165 048166 048167 Vapor duct for glass assembly C and V 048160 048161 048162 048163 050560 050561 050562 050563 SJ 24/29 044444 (177 - 190 mm) Analytic* Vapor duct for glass assembly C and V (200 - 210 mm) Vapor duct compatible with KD22 SJ 29/32 Vapor duct for glass assembly C and V (180 mm) 045650 Additional glassware Additional glassware like evaporating flasks, drying flasks, receiving flasks, beaker flasks, Reitmeyer adapters (bump traps) and distillation spiders can be found in the glassware brochure. www.buchi.com/laboratory-evaporation Quality in your hands R-210 R-215 Data Sheet en 1401 D / Technical data are subject to change without notice / Quality Systems ISO 9001 The English version is the original language version and serves as basis for all translations into other languages. *there is no liquid flowing back into the evaporating flask