Transcript
NEW!
LIGHTING CONTROLS BLUERIDGE RELAY PANELS RP BASIC SERIES
DESCRIPTION
Relay Panel Basic (RP Basic) is a UL Listed lighting control panel. RP Basic may be scheduled from any BACnet BAS and is compatible with all low voltage switches as well asGeneral occupancy sensors. RP Basic mounts Architecture near the circuit breaker panel to provide centralized control of branch lighting circuits. The relay panels come with a black powder coated steel enclosure and a removable door for 8 relay capacity panels, or a hinged reversable door for 16 relay capacity panels and above.
Internet
BAS Router
FEATURES
ON
BT485 Terminator Plug Internet (if applicable)
OCC OCC
9 01
1
COMM
2
3
4
6
7
8
SW3
9 01
78
10’s
1’s
IP
Test Button
Internet BACnet MS/TP TEST
LS5
LS5
5
23
LVS
J2 J1
23
General Architecture
CAN/DDN
Term
LEXP
Bluetooth
Field Devices
Zone Control (ZC)
Relay Panel (RP)
Controller Terminations Controller BoardBoard Terminations
Retrofit Interior (RI)
Retrofit Kit (RK)
24VDC RELAY 1-32 UI 1 Field Devices Field Devices Field Devices UI 2 Network Address Rotary Switch 10’s Programing / Protocol Programing / Protocol Network Address Rotary Switch 10’s 24VDC Relays 1-32 Dip Switch Network Address Dip Switch UI 3 Network Address Rotary1’s SwitchLVS 1’s UI 4OCC LS5 Rotary Switch J2 Zone Control (ZC) Relay Panel (RP) RELAY 33-64 Retrofit 24VDC J2 J1 UI 5 SW3 10’s 1’s LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) SW3 10’s 1’s COMM Relays 33-64 UI 6 COMM Test Button 24VDCField Devices Test Button TEST UI 7 TEST Power LED UI 8 24VDC Run LED Controller Board Terminations24VDC Term LEXP UI 15 Term LEXP UI 9 Network Address Rotary Switch 10’s Programing / Protocol UI 16 BACnet(+) In/Out UI 10 LS5 24VAC(+) Auxiliary Out Dip Switch LVS 24VDCNetwork OCC Address BACnet(-) In/Out 24VDC 24VAC(-) Auxiliary Out UI 17Rotary Switch 1’s Shield In UI 11 Micro-B USB Port J2 UI 18 PWR RUN (for configuration changes with TK-2.0 Tech Kit) J1 UI 12 24VAC(+) Power In 24VDC SW3 10’s 1’s BT485 Terminator Plug COMM24VDC 24VAC(-) In LVS (Low UI Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Power Sensor) 19Test Button UI 13 RELAY 1-32 (if applicable) TEST RELAY 1-32 UI 20 UI 14 Field Devices
3
4
5
7
8
9 01
78
78
9 01
9 01
6
78
78
2
6
7
8
IN OUT
9 01
78
78
LEXP
24VDC UI 21 UI 22 24VDC UI 23 UI 24 24VDC GND GND GND GND GND GND GND GND GND GND GND 5VDC GND
CAN/DDN
5
Input Terminals Controller Board Terminations Bluetooth
RELAY 33-64
Term
4
456
Relays 1-32 Relays 1-32 Bluetooth Plug RELAY 33-64 (for configuration changes with TK-2.0 Tech Kit)
3
23
9 01
2
23
1
456
ON
24VDC Relays 33-64 RELAY 1-32 33-64 UIRelays 1 BACnet(+) In/Out UI 2 24VDC BACnet(-) In/Out Power LED UIPower 3 LED Shield In Run LED UI 4 RELAY 33-64 Run LED Micro-B USB Port 24VDC UI 5 configuration changes with TK-2.0 Tech Kit) (for UI 6 Out 24VAC(+)24VAC(+) Auxiliary Auxiliary Out BT485 24VDC 24VAC(-) Out Terminator Plug UI 24VAC(-) 7 Auxiliary Auxiliary Out (if applicable) UI 8 24VDC 24VDC 24VAC(+) Power In Power UI 15 In UI 24VAC(+) 9 UI 16 InPower In 24VAC(-)24VAC(-) Power UI 10 24VDC 24VDC UI 17 UI 11 UI 18 PWR RUN UI 12 24VDC 24VDC UI 19 UI 13 Bluetooth Plug UI 20 UI 14
Programing / Protocol Network Address Rotary Switch 10’s
Term
24VAC(+) Power In 24VAC(-) Power In
kele.com
LTR Terminations
3
4
5
6
7
8
10’s
78
78 2
9 01
1’s
Line In Relay Output
Test Button UI (Universal Input) / GND (Ground)
IN OUT
24VDC UI 21 UI 22 24VDC UI 23 UI 24 24VDC UI (Universal Input) / GND (Ground) GND GND GND GND UI (Universal Input) / GND (Ground) GND GND GND GND GND GND IN OUT GND 5VDC GND
Earth Ground
24VAC(+) Auxiliary Out 24VAC(-) Auxiliary Out CAN/DDN
CAN/DDN
24VDC UI 21 UI 22 24VDC 24VDC UIUI23 21 UIUI24 22 24VDC 24VDC GND UI 23 GND UI 24 GND 24VDC GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND 5VDC GND GND GND GND 5VDC GND
1
SW3
456
IT EASY.
White
9 01
456
24VDC WE MAKE UI 1 Transformer Terminations UI 2 24VDC Line In Line In
Transformer Terminations LTR Terminations LTR Terminations Transformer Terminations
Brown
COMM 120VAC Black
Power LED Neutral Run LED
Bluetooth
(for configuration changes with TK-2.0 Tech Kit)
277VAC Relays 33-64
ON
23
PWR RUN
Rotary Switch 1’s J2 J1
23
PWR RUN
IN OUT
TransformerRelays Terminations LTR Terminations Dip Switch Network Address 1-32
Input Terminals
March 2014
UI (Universal Input) / GND (Ground)
8
CAN/DDN
7
456
6
456
5
456
4
23
3
23
Input Terminals Input Terminals
2
23
24VDC UI 1 UI 2 24VDC UI 3 UI 4 24VDC UI 5 UI 6 24VDC UI 7 UI 8 24VDC UI 9 UI 10 24VDC UI 11 UI 12 24VDC UI 13 UI 14
24VDC UI 1 UI 2 24VDC UI 3 UI 4 24VDC UI 5 UI 6 24VDC UI 7 UI 8 24VDC 24VDC 24VDC UI 9 UI 15 UI 15 UI 10 UI 16 UI 16 24VDC 24VDC 24VDC UI 11 UI 17 UI 17 UI 12 UI 18 UI 18 24VDC 24VDC 24VDC UI 13 UI 19 UI 19 UI 14 UI 20 UI 20
9 01
1
1
Bluetooth
Bluetooth
Bluetooth Plug Bluetooth Plug (for configuration withTech TK-2.0 (for configuration changes changes with TK-2.0 Kit)Tech Kit)
ON
ON
23
Micro-B Micro-B USB PortUSB Port (for configuration withTech TK-2.0 (for configuration changes changes with TK-2.0 Kit)Tech Kit) J1 BT485 Terminator Plug BT485 Terminator Plug (if applicable) (if applicable)
LIGHTING CONTROLS
BAS Router
LVS (Low Switch) Voltage /Switch) / OCC (Occupancy / LS5 (Light Sensor) LVS (Low Voltage OCC (Occupancy Sensor) Sensor) / LS5 (Light Sensor) Bluetooth Plug Field Devices Field Devices Field Devices (for configuration changes with TK-2.0 Tech Kit) BAS Router
BACnet(+) BACnet(+) In/Out In/Out BACnet(-) BACnet(-) In/Out In/Out Shield InShield In
11
Rotary Switch 1’s
Shield In Micro-B USB Port (for configuration changes with TK-2.0 Tech Kit)
Field Devices Field Devices General Architecture
LVS
Programing / Protocol Network Address Rotary Switch 10’s Kit (RK) RetrofitRetrofit Kit (RK) Dip Switch Network Address
BACnet(+) In/Out (RI) RetrofitRetrofit Interior Interior (RI) BACnet(-) In/Out
Relay(RP) Panel (RP) Relay Panel
WIRING
78
Zone Control Zone Control (ZC) (ZC)
456
Field Devices d Devices
456
BAS Router S Router
Field Devices Field Devices Field Devices UL Listed (UL E133813) BACnet MS/TP communication to BAS network Zone Control (ZC) Relay Panel (RP) Retrofit Interior (RI) Line and low voltage compartment separation Upgradable controller board firmware Field Devices 347 VAC Transformer (optional) Other available options for 16 or more relay capacity panels: IP InternetInternet IP LS5 LVS Low/Line voltage bays (optional) OCC Multi-pole lighting contactors (optional) BACnetBACnet MS/TP MS/TP LVS (Low Voltage Switch) / OCC (Occupancy Sensor) / LS5 (Light Sensor) 24 VAC auxiliary transformer 24 VDC power supply RPSB08 BACnet IP router (optional) Field Devices Field Devices Field Devices Devices (optional) Field Devices Field Terminations Devices UL924 emergencyField bypass Controller Board
456
rchitecture ecture
• • • • • • • • • • • •
Wire Strip Length Indicator TEST Manual Override Lever LEXP
888-397-5353 USA
RELAY 1-32
609
Relays 1-32
Interior
NEW!
LIGHTING CONTROLS BLUERIDGE RELAY PANELS RP BASIC SERIES SPECIFICATIONS Supply Voltage Auxiliary Out
11
120, 277, 347 VAC ±10%, 50-60 Hz 24VAC, 800mA (devices with full wave rectified power supply only) Analog Switch Inputs 0-5 VDC, 0-10 VDC, or 4-20 mA Lighting Tough Relay (LTR) Resistive Load 20A @ 347 VAC / 1.5 HP @ 120 VAC Short Circuit Current Rating 30,000A @ 277 VAC Contactor Ballast 30A @ 347 VAC Contactor Tungsten 20A @ 347 VAC Relay Type SPST latching with manual override lever, pulse driven Relay Terminals Universal screw terminal, box type clamp, accepts double 14-10 AWG or single 8AWG (solid or stranded copper wire) Relay Life Cycles 300,000 on/off cycles @ full load Relay Life 1 million Connection Style Micro-B USB or Bluetooth wireless Communication Protocol BACnet MS/TP Communication Ports Network ready, RS-485, half duplex, daisy chain wiring Network Max length 4000 ft Configuration Tech Kit 2.0 Override Manual Operating Temperature 32° to 125°F (0° to 50°C)
Operating Humidity Mounting Enclosure Rating Enclosure Dimensions RPSB08- RPSB16- RPSB32- RPSB48- RPSB64- Approvals Weight RPSB08- RPSB16- RPSB32- RPSB48- RPSB64- Warranty
20-95% RH non-condensing Surface Mounted Type 1, (dry / indoor environment) 16ga steel with black powder coat finish 13.00"W x 14.75"H x 5.75"D ( 33.0 x 37.5 x 14.6 cm) 18.00"W x 16.20"H x 5.75"D (45.7 x 41.1 x 14.6 cm) 18.00"W x 25.00"H x 5.75"D (63.5 x 45.7 x 14.6 mm) 18.00"W x 33.80"H x 5.75"D (45.7 x 85.9 x 14.6 cm) 18.00"W x 42.60"H x 5.75"D (45.7 x 10.82 x 14.6 cm) UL 916, FCC Part 15, CEC Title 24, Electronics meet or exceed IEC Level 3 20.5 lb (9.3 kg) 32 lb (14.5 kg) 47.5 lb (21.5 kg) 63.5 lb (28.8 kg) 82.5 lb (37.4 kg) 2 years
LIGHITING CONTROLS
ORDERING INFORMATION MODEL RPSB08 RPSB16 RPSB32 RPSB48 RPSB64
RPSB16
DESCRPITION Relay Panel Switching Basic, 8 relays capacity, 24 Universal Inputs Relay Panel Switching Basic, 16 relays capacity, 24 Universal Inputs Relay Panel Switching Basic, 32 relays capacity, 24 Universal Inputs Relay Panel Switching Basic, 48 relays capacity, 24 Universal Inputs Relay Panel Switching Basic, 64 relays capacity, 24 Universal Inputs NUMBER OF RELAYS INSTALLED XX Replace “XX” with the number of relays installed POWER OPTIONS 0 120/277V AC transformer 1 347V AC transformer 2 120/277V AC transformer plus 120/277V AC auxiliary transformer (for 16 relays capacity and above panels only) 3 347V AC transformer plus 347V AC auxiliary transformer (for 16 relays capacity and above panels only) SPECIAL OPTIONS (for 16 relays capacity and above panels only) 00 None X1 With UL924 Emergency Bypass (Relays 17-32 only) Low Voltage Bay Options (Bottom of panel, for 16 relays capacity and above panels only) (BLANK) None L1 9" bay LA 9" bay plus one 2.5A 24V DC power supply LB 9" bay plus two 2.5A 24V DC power supplies LC 9" bay plus one BACnet IP router LD 9" bay plus one BACnet IP router and one 2.5A 24V DC power supply LE 9" bay plus one BACnet IP router and two 2.5A 24V DC power supply LINE VOLTAGE BAY OPTIONS WITH DEAD FRONT COVER (Top of panel, for 16 relays capacity and above panels only) (BLANK) None H1 9" bay HA 9" bay plus one 4 pole 30A electrically held lighting contactor, 120V coil HB 9" bay plus two 4 pole 30A electrically held lighting contactor, 120V coil HC 9" bay plus four 4 pole 30A electrically held lighting contactor, 120V coil HD 9" bay plus one 4 pole 30A electrically held lighting contactor, 277V coil HE 9" bay plus two 4 pole 30A electrically held lighting contactor, 277V coil HF 9" bay plus four 4 pole 30A electrically held lighting contactor, 277V coil
16
LTR1 RPRVD RPSB-CTRL TK- 2.0
610
1
X1
Example: RPSB161X1 Relay Panel Switching Basic w/ UL924, 16 Relay Capacity, 16 Relays Installed, 24 Universal Inputs, 347V AC Control Power Transformer
ACCESSORIES Relay, Lighting Tough Relay, Field Installation, 20A Relay Voltage Divider Relay Panel Switiching Basic, Replacement Controller, PCB ONLY Technicians Kit, includes Micro-USB Cable, USB flash drive with Essentials software, USB Bluetooth Dongle, Bluetooth module, and Screwdriver
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014