Preview only show first 10 pages with watermark. For full document please download

Rs2001m Rs2007m 8187

   EMBED


Share

Transcript

RS2001M THRU RS2007M SINGLE-PHASE GLASS PASSIVATED SILICON BRIDGE RECTIFIER VOLTAGE RANGE 50 to 1000 Volts CURRENT 20 Amperes FEATURES Low leakage Low forward voltage Surge overload rating : 300 amperes peak Mounting position: Any Ideal for printed circuit boards High forward surge current capability RS-20M .189 (4.8) .173 (4.4) .197 (5) .165 (4.2) .150 (3.8) .106 (2.7) .096 (2.3) .087 (2.2) .071 (1.8) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS .800 (20.3) .775 (19.7) * Epoxy: Device has UL flammability classification 94V-O * UL list the recognized component directory,file #E94233 f .138 (3.5) .126 (3.2) .150 (3.8) .134 (3.4) 1.193 (30.3) 1.169 (29.7) .441 (11.2) .425 (10.8) MECHANICAL DATA .114 (2.9) .098 (2.5) .708 (18.0) .669 (17.0) * * * * * * .043 (1.1) .035 (0.9) Ratings at 25 o C ambient temperature unless otherwise specified. resistive or inductive load. .031 (0.8) .023 (0.6) .402 (10.2) .303 (7.7) .303 (7.7) .386 (9.8) .287 (7.3) .287 (7.3) Dimensions in inches and (millimeters) MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted) RATINGS SYMBOL RS2001M RS2002M RS2003M RS2004M RS2005M RS2006M RS2007M UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 Volts VDC 50 100 200 400 600 800 1000 Volts Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T C = 55 o C Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Current Squared Time IO 20 Amps I FSM 300 Amps 2 373.3 A 2S I T Typical Thermal Resistance (Note 1) Operating and Storage Temperature Range R q JC 1.5 R q JA 22 T J, T STG -55 to + 150 0 C/ W 0 C ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 10A DC Maximum DC Reverse Current at Rated DC Blocking Voltage @T A = 25 o C @T A = 100 o C SYMBOL RS2001M RS2002M RS2003M RS2004M RS2005M RS2006M RS2007M UNITS VF 1.1 Volts IR NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted. 2. "Fully ROHS compliant", "100% Sn plating (Pb-free)". 5.0 100 uAmps 2010-01 REV:A 30 20 60 10 50 POWER DISSIPATION, (W) INSTANTANEOUS FORWARD CURRENT, (A) RATING AND CHARACTERISTICS CURVES ( RS2001M THRU RS2007M ) TC= 150 OC (TYP) 5 TC= 25 OC (TYP) 2 1 0.5 0.2 0 Pulse test per one diode 0.2 0.4 0.6 0.8 1 1.2 1.4 40 30 20 10 0 1.6 sine wave TJ = 150 OC 0 INSTANTANEOUS FORWARD VOLTAGE, (V) 0 8.3ms 8.3ms 200 1 cycle non-repetitive T j=25 100 0 0 1 2 5 10 20 50 1 0 100 s oldering land 5mmf s ine wave R -load free in air 2 0 40 THERMAL RESISTANCE (OC/W) AVERAGE FORWARD CURRENT, (A) heats ink Tc Tc 8 s ine wave R -load on heats ink 90 110 120 160 FIG.4 TYPICAL FORWARD CURRENT DERATING CURVE 1.0 70 80 AMBIENT TEMPERATURE, (OC) 16 50 24 P .C .B 1.2 30 20 3 20 0 10 16 on glas s -epoxi s ubs trate FIG.3 SURGE FORWARD CURRENT CAPABILITY 4 12 4 NUMBER OF CYCLE 12 8 FIG.2 POWER DISSIPATION AVERAGE FORWARD CURRENT, (A) s ine wave IF S M PEAK FORWARD SURGE CURRENT, (A) FIG.1 TYPICAL INSTANTANEOUS FORWARD CHARACTERITICS 300 4 AVERAGE RECTIFIED FORWARD CURRENT, (A) 130 HEAT SINK TEMPERATURE, (OC) 150 FIG.5 TYPICAL FORWARD CURRENT DERATING CURVE 170 with thermal compound 0.8 0.6 0.4 0.2 0 2 3 4 5 6 7 MOUNTING TORQUE (kg.cm) FIG.6 CONTACT THERMAL RESISTANCE fcf 8 Marking Description Rectron Logo Part No. RS200XM Voltage-code UL Logo V Y WW Year – code: (Y:Last digit of year) Week – code: (WW:01~52) 1-------50V 2-------100V 3-------200V 4-------400V 5-------600V 6-------800V 7-------1000V PACKAGING OF DIODE AND BRIDGE RECTIFIERS BULK PACK EA PER BOX INNER BOX SIZE CARTON SIZE PACKING CODE RS-20M -B 300 230*190*46 410*243*157 1,800 13.37 PACKAGE PACKING CODE EA PER BOX INNER BOX SIZE CARTON SIZE EA PER CARTON WEIGHT(Kg) RS-20M -C 600 490*135*110 510*293*131 1,200 13.12 (mm) (mm) EA PER CARTON GROSS WEIGHT(Kg) PACKAGE TUBE PACK (mm) (mm) DISCLAIMER NOTICE Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Rectron: RS2006M RS2004M RS2002M RS2007M RS2005M RS2003M RS2001M