Preview only show first 10 pages with watermark. For full document please download

Rs2t4-210 Dm.cdr

   EMBED


Share

Transcript

RS2T4-210 Isolated Daul Port RS232 to RS232/RS422/RS485 Converter Board Features Converts RS232 signal to RS232/422/485 signal for data transmitting Automatically detects signals to match RS-422 or RS-485 networks Auto Baud Rate Detection Auto Data Flow 2.5K VDC Isolation for com port / 3K VDC Isolation for power On Board I/O 12.5 mm 1.5 mm 80 mm System Specification Pin Assignment Number of Ports Box Header : : Isolation : Data Rate : Power Consumption Power supply Dimension Operating Temp. Storage Temp. Humidity Range : : : : : : 2 x DB9-M 1 x 5VDC-IN 1 x RS232 (2x10 pitch 2.0mm) Power: 3KV DC Com Port: 2.5KV DC 1200, 2400, 4800, 9600, 19.2k, 38.4k, 57.6k, 115.2k Auto Baud Rate Detection Auto Data Flow 0.5W 5V@90mA 76 x 30 x 16mm -10~70 C -25~85 C 10-90% R.H. Note: All Specifications are subject to change without prior notice! J3,J8: RS-232/RS-485/RS-422 Complex Port J1: Power Input Pin Symbol Description 1 VCC +5VDC 2 GND Ground J2: Dual RS-232 Pin 1 2 3 4 5 6 7 8 9 Symbol DB1(2)_P1 DB1(2)_P2 DB1(2)_P3 DB1(2)_P4 GND DB1(2)_DSR DB1(2)_RTS DB1(2)_CTS DB1(2)_RI Description RS-232 DCD/RS-485 D-/RS-422 T(R)XRS-232 RXD/RS-485 D+/RS-422 T(R)X+ RS-232 TXD/ RS-422 R(T)XRS-232 DTR/ RS-422 R(T)X+ Ground RS-232 DSR RS-232 RTS RS-232 CTS RS-232 RI Pin Symbol Description 1 COM1_DCD RS-232 Port 1 DCD signal 2 COM1_DSR RS-232 Port 1 DSR signal 3 COM1_RXD RS-232 Port 1 RXD signal 4 COM1_RTS RS-232 Port 1 RTS signal 5 COM1_TXD RS-232 Port 1 TXD signal 6 COM1_CTS RS-232 Port 1 CTS signal 7 COM1_DTR RS-232 Port 1 DTR signal 8 COM1_RI RS-232 Port 1 RI signal 9 GND Ground 10 GND Ground 11 COM2_DCD RS-232 Port 2 DCD signal 12 COM2_DSR RS-232 Port 2 DSR signal 13 COM2_RXD RS-232 Port 2 RXD signal 14 COM2_RTS RS-232 Port 2 RTS signal 15 COM2_TXD RS-232 Port 2 TXD signal 16 COM2_CTS RS-232 Port 2 CTS signal 17 COM2_DTR RS-232 Port 2 DTR signal J9,J10: RS-232/RS-485,RS422 Selection 18 COM2_RI RS-232 Port 2 RI signal Left: RS-485,RS-422 19 GND Ground 20 GND Ground Note: All Specifications are subject to change without prior notice! SW1: Com Port Mode Switch Switch Serial Port Status Mode 1 COMx OFF(Default) RS-422: Master mode (J3) RS-485: Auto flow control ON RS-422: Slave mode RS-485: N/A 2 COMx OFF(Default) RS-422: Master mode (J8) RS-485: Auto flow control ON RS-422: Slave mode RS-485: N/A J4,J5,J6,J7: 120 ohm Termination Selection Open: Normal Mode (below 300M) Close: Long Distance Mode (up to 1.2KM) Right: RS-232 Revised Date:6/30/2008