Preview only show first 10 pages with watermark. For full document please download

Rslogix500 Project Report

   EMBED


Share

Transcript

RSLogix500 Project Report LIFTE.RSS Processor Information Processor Type: Bul.1764 Micrologix 1500 LRP Series C Processor Name: LIFT_E Total Memory Used: 542 Instruction Words Used - 211 Data Table Words Used Total Memory Left: 13346 Instruction Words Left Program Files: 11 Data Files: 41 Program ID: 342f Page 1 Thursday, September 07, 2006 - 08:08:34 LIFTE.RSS I/O Configuration 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Page 1 Bul.1764 1769-IA16 Micrologix 1500 LRP Series C 16-Input 79/132 VAC Thursday, September 07, 2006 - 08:08:34 LIFTE.RSS Channel Configuration CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 0 (SYSTEM) - Driver: DF1 Half Duplex Slave CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex CHANNEL 1 (SYSTEM) - Driver: DF1 Full Duplex Edit Resource/Owner Timeout: 60 Passthru Link ID: 1 Write Protected: No Comms Servicing Selection: Yes Message Servicing Selection: Yes 1st AWA Append Character: \d 2nd AWA Append Character: \a Edit Resource/Owner Timeout: 60 Passthru Link ID: 1 Write Protected: No Comms Servicing Selection: Yes Message Servicing Selection: Yes 1st AWA Append Character: \d 2nd AWA Append Character: \a Source ID: 1 (decimal) Baud: 19200 Parity: NONE Control Line : No Handshaking Error Detection: BCC Embedded Responses: Auto Detect Duplicate Packet Detect: Yes ACK Timeout: 50 NAK Retries: 3 ENQ Retries: 3 Page 1 Thursday, September 07, 2006 - 08:08:34 LIFTE.RSS Program File List Name Number Type [SYSTEM] 0 1 2 3 4 5 6 7 8 9 10 SYS SYS LADDER LADDER LADDER LADDER LADDER LADDER LADDER LADDER LADDER MAIN TIME BASE PUMP1 PUMP2 Page 1 Rungs 0 0 27 17 9 9 1 1 1 1 1 Debug No No No No No No No No No No No Bytes 0 0 577 557 408 408 3 3 3 3 3 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS Data File List Name Number Type Scope Debug OUTPUT INPUT STATUS BINARY TIMER COUNTER CONTROL INTEGER FLOAT 0 1 2 3 4 5 6 7 8 40 O I S B T C R N F T Global Global Global Global Global Global Global Global Global Global No No No No No No No No No No Page 1 Words 12 15 0 2 60 30 3 63 20 6 Elements Last 4 5 66 2 20 10 1 63 10 2 O:3 I:4 S:65 B3:1 T4:19 C5:9 R6:0 N7:62 F8:9 T40:1 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 2 - MAIN --- Total Rungs in File = 27 CR3 / FU204 POWER FAILURE LIFTE_AC_FAIL I:0 LIFT_E_AC_ALARM N7:0 0000 0 Bul.1764 / CR211 UPS FAILURE LIFTE_UPS_FAIL I:0 0 LIFT_E_UPS_FAIL N7:0 0001 1 Bul.1764 1 VALVE VAULT ALARM LIFTE_V_V_ALA I:0 VALVE VAULT ALARM LIFT_E_V_V_ALA N7:0 2 Bul.1764 12 0002 CR5 LOW LEVEL FLOAT ALAR LIFTE_LO_LO_ALM I:0 LOW LEVEL ALARM LIFT_E_LO_LO_ALARM N7:0 0003 3 Bul.1764 AR / CR373 HIGH LEVEL FLOAT ALA LIFTE_HI_HI_ALM I:0 14 HIGH LEVEL ALARM LIFT_E_HI_HI_ALAM N7:0 0004 4 Bul.1764 CR11 P1 HEAT FAIL SENSOR LIFTE_P1_FAIL I:0 4 P1 HEAT SENSOR LIFT_E_P1_HEAT N7:0 0005 5 Bul.1764 5 P1 CURRENT SENSOR LIFTE_P1_STS I:0 P1 CURRENT SWITCH LIFT_E_P1_STS N7:0 6 Bul.1764 6 0006 CR13 P2 HEAT FAIL SENSOR LIFTE_P2_FAIL I:0 P2 HEAT SENSOR LIFT_E_P2_HEAT N7:0 0007 7 Bul.1764 Page 1 7 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 2 - MAIN --- Total Rungs in File = 27 P2 CURRENT SENSOR LIFTE_P2_STS I:0 P2 CURRENT SWITCH LIFT_E_P2_STS N7:0 8 Bul.1764 8 0008 CR7 / CR365 LEVEL 1 FLOAT LIFTE_WETWELL_LVL_1 I:0 LEVEL 1 FLOAT LIFT_E_WETWELL_LVL_1 N7:0 0009 9 Bul.1764 CR8 / CR369 LEVEL 2 FLOAT LIFTE_WETWELL_LVL_2 I:0 9 LEVEL 2 FLOAT LIFT_E_WETWELL_LVL_2 N7:0 0010 10 Bul.1764 10 LEVEL 1 FLOAT ALARM TIMER TON Timer On Delay Timer T4:10 Time Base 1.0 Preset 600< Accum 0< LEVEL 1 FLOAT ALARM TIMER T4:10 0011 DN RESET P1 SCADA BIT LIFT_E_P1_RESET N7:62 0012 0 EN DN LIFT_E_LVL1_ALARM N7:2 L 3 LIFT_E_LVL1_ALARM N7:2 U 3 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT_E_P2_REM_MAN N7:61 1 CR6 / CR359 STOP PUMPS FLOAT LIFTE_PUMPS_OFF I:0 LEVEL LOW/STOP PUMP LIFT_E_LVL_OFF N7:0 0013 11 Bul.1764 Page 2 11 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 2 - MAIN --- Total Rungs in File = 27 PANEL DOOR SWTCH LIFTE_DOOR_ALARM I:1 PANEL DOOR OPEN LIFT_E_DOOR_ALARM N7:1 L 0 0014 0 1769-IA16 PANEL DOOR SWTCH LIFTE_DOOR_ALARM I:1 PANEL DOOR OPEN LIFT_E_DOOR_ALARM N7:1 0 1769-IA16 0 PANEL DOOR ALARM TIMER TON Timer On Delay Timer T4:8 Time Base 1.0 Preset 30< Accum 0< 0015 PANEL DOOR ALARM TIMER T4:8 EN DN PANEL DOOR OPEN LIFT_E_DOOR_ALARM N7:1 U 0 0016 DN PANEL TEMP SWTCH LIFTE_ICE_CUBE_ALARM I:1 PANEL TEMP SWITCH TIMER T4:9 PANEL TEMPERATURE LIFT_E_ICE_CUBE_ALA N7:1 1 1769-IA16 DN 1 0017 PANEL TEMP SWITCH TIMER TON Timer On Delay Timer T4:9 Time Base 1.0 Preset 120< Accum 0< P1 START/STOP RELAY CR251 LIFTE_P1_SS O:0 EN DN P1 START/STOP RELAY N7:3 0018 0 Bul.1764 P2 START/STOP RELAY CR254 LIFTE_P2_SS O:0 0 P2 START/STOP RELAY N7:3 0019 1 Bul.1764 Page 3 1 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 2 - MAIN --- Total Rungs in File = 27 CR10 P1 SEAL FAIL SENSOR LIFTE_P1_SEAL_FAIL I:1 P1 SEAL FAIL ALARM LIFT_E_P1_SEAL N7:0 0020 2 1769-IA16 2 CR12 P2 SEAL FAIL SENSOR LIFTE_P2_SEAL_FAIL I:1 P2 SEAL FAIL ALARM LIFT_E_P2_SEAL N7:0 0021 3 1769-IA16 3 STATUS RED LIGHT LT257 LIFTE_STATUS_LAMP O:0 RED STATUS LIGHT N7:3 0022 2 Bul.1764 2 Major Error Halted S:1 PLC ALARM LIFT_E_FIX_PLC_ALARM N7:2 13 0 0023 LIFT_E_AC_ALARM N7:0 0024 0 P1_FAILED N7:3 P2_FAILED N7:3 5 6 P1_FAILED N7:3 Time Base S:4 P2_FAILED N7:3 Time Base S:4 5 12 6 12 P1_FAILED N7:3 P2_FAILED N7:3 Time Base S:4 5 6 12 STATUS RED LIGHT LT257 LIFTE_STATUS_LAMP O:0 2 Bul.1764 Page 4 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 2 - MAIN --- Total Rungs in File = 27 0025 TIME BASE SUBROUTINE JSR Jump To Subroutine SBR File Number U:3 PUMP 1 SUBROUTINE JSR Jump To Subroutine SBR File Number U:4 PUMP 2 SUBROUTINE JSR Jump To Subroutine SBR File Number U:5 Overflow Trap S:5 U 0 0026 Page 5 END Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 3 - TIME BASE --- Total Rungs in File = 17 RUNG 0 ALLOWS THE T4:0 TIMER TO TIME TO 3600 THIS IS 1 HOUR HOUR TIMER HOUR_TIMER TON Timer On Delay Timer T4:0 Time Base 1.0 Preset 3600< Accum 20< 0000 RUNG 1 ALLOWS THE HOUR PULSE TO BE COUNTED TO C5:0.ACC HOUR TIMER HOUR_TIMER/DN T4:0 0001 DN DAY_COUNTER CTU Count Up Counter C5:0 Preset 24< Accum 16< EN DN CU DN HOUR TIMER HOUR_TIMER T4:0 RES RUNG 2 IS THE DAY COUNTER C5:1 DAY_COUNTER/DN C5:0 WEEK_COUNTER CTU Count Up Counter C5:1 Preset 7< Accum 0< 0002 DN CU DN DAY_COUNTER C5:0 RES 0003 WEEK_COUNTER.ACC GEQ Grtr Than or Eql (A>=B) Source A C5:1.ACC 0< Source B 7 7< LIFTE_PUMP1_START B3:0 LIFTE_PUMP2_START B3:0 10 11 WEEKLY_CHANGE_BIT B3:0 0 Page 1 Thursday, September 07, 2006 - 08:08:35 LIFTE.RSS LAD 3 - TIME BASE --- Total Rungs in File = 17 WEEK COUNTER RESETTING TIMER TON Timer On Delay Timer T40:1 Time Base 0.01 Preset 30< Accum 0< WEEKLY_CHANGE_BIT B3:0 0004 0 WEEK COUNTER RESETTING TIMER T40:1 EN DN WEEK_COUNTER C5:1 RES DN ALTERNATE LEAD ALTERNATE_LEAD CTU Count Up Counter C5:2 Preset 2< Accum 1< WEEKLY_CHANGE_BIT B3:0 0005 0 CU DN LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 P1 P2 ENABLED P1_P2_ENABLED B3:0 2 3 5 0006 0007 ALTERNATE LEAD ACC ALTERNATE_LEAD_ACC EQU Equal Source A C5:2.ACC 1< Source B 0 0< P1 P2 ENABLED P1_P2_ENABLED B3:0 P1 LEAD P1_LEAD B3:0 5 15 LIFT_E_FIX_P1_LEAD N7:2 1 Page 2 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 P1 P2 SET LEAD P1_P2_SET_LEAD B3:1 3 1 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 3 - TIME BASE --- Total Rungs in File = 17 0008 ALTERNATE LEAD ACC ALTERNATE_LEAD_ACC EQU Equal Source A C5:2.ACC 1< Source B 1 1< P1 P2 ENABLED P1_P2_ENABLED B3:0 P2 LEAD P2_LEAD B3:1 5 0 LIFT_E_FIX_P2_LEAD N7:2 2 LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 P1 P2 SET LEAD P1_P2_SET_LEAD B3:1 2 1 P1 LEAD P1_LEAD B3:0 P2 LEAD P2_LEAD B3:1 15 0 0009 LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 0010 2 P1 P2 SET LEAD P1_P2_SET_LEAD B3:1 L 1 P1 P2 SET LEAD P1_P2_SET_LEAD B3:1 U 1 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 3 0011 ALTERNATE LEAD ACC ALTERNATE_LEAD_ACC GEQ Grtr Than or Eql (A>=B) Source A C5:2.ACC 1< Source B 2 2< LIFT_E_SET_P1_LEAD N7:2 0012 14 LIFT_E_SET_P2_LEAD N7:2 ALTERNATE LEAD ACC ALTERNATE_LEAD_ACC CLR Clear Dest C5:2.ACC 1< PUMP LEAD SET TIMER TON Timer On Delay Timer T4:17 Time Base 1.0 Preset 7< Accum 0< EN DN 15 Page 3 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 3 - TIME BASE --- Total Rungs in File = 17 PUMP LEAD SET TIMER T4:17 LIFT_E_SET_P1_LEAD N7:2 U 14 0013 DN LIFT_E_SET_P2_LEAD N7:2 U 15 LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 LIFT_E_SET_P1_LEAD N7:2 2 14 0014 HOUR TIMER HOUR_TIMER.ACC CLR Clear Dest T4:0.ACC 20< DAY_COUNTER.ACC CLR Clear Dest C5:0.ACC 16< WEEK_COUNTER.ACC CLR Clear Dest C5:1.ACC 0< ALTERNATE LEAD ACC ALTERNATE_LEAD_ACC MOV Move Source 0 0< Dest C5:2.ACC 1< Page 4 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 3 - TIME BASE --- Total Rungs in File = 17 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 LIFT_E_SET_P2_LEAD N7:2 3 15 0015 HOUR TIMER HOUR_TIMER.ACC CLR Clear Dest T4:0.ACC 20< DAY_COUNTER.ACC CLR Clear Dest C5:0.ACC 16< WEEK_COUNTER.ACC CLR Clear Dest C5:1.ACC 0< ALTERNATE LEAD ACC ALTERNATE_LEAD_ACC MOV Move Source 1 1< Dest C5:2.ACC 1< 0016 Page 5 END Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 4 - PUMP1 --- Total Rungs in File = 9 LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 LIFT E P1 AUTOMATIC=0 MANUAL=1 LIFT_E_P1_REM_MAN N7:61 2 0 0000 P1 LEAD P1_LEAD B3:0 LEVEL 1 FLOAT LIFT_E_WETWELL_LVL_1 N7:0 15 9 LIFT_E_LVL1_ALARM N7:2 LEVEL 2 FLOAT LIFT_E_WETWELL_LVL_2 N7:0 3 10 P2 LEAD P2_LEAD B3:1 LEVEL 2 FLOAT LIFT_E_WETWELL_LVL_2 N7:0 0 10 LIFTE_PUMP1_START B3:0 L 10 LIFT E P1 AUTOMATIC=0 MANUAL=1 LIFT_E_P1_REM_MAN N7:61 LEVEL LOW/STOP PUMP LIFT_E_LVL_OFF N7:0 0 11 LIFTE_PUMP1_START B3:0 U 10 0001 LIFT E P1 AUTOMATIC=0 MANUAL=1 LIFT_E_P1_REM_MAN N7:61 0 First Pass S:1 15 LIFT E SCADA P1 ON LIFT_E_SCADA_P1_ON N7:61 LIFT E P1 AUTOMATIC=0 MANUAL=1 LIFT_E_P1_REM_MAN N7:61 LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 4 0 2 0002 Page 1 SCADA_MAN_ON_OFF B3:0 L 9 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 4 - PUMP1 --- Total Rungs in File = 9 LIFT E SCADA P1 OFF LIFT_E_SCADA_P1_OFF N7:61 0003 5 Page 2 SCADA_MAN_ON_OFF B3:0 U 9 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 4 - PUMP1 --- Total Rungs in File = 9 LIFT E P1 DISABLED=1 ENABLED=0 LIFT_E_P1_ENABLED N7:61 LIFTE_PUMP1_START B3:0 LIFT E P1 TWO MINUTE DELAY BEFORE P1 CAN RESTART T4:4 2 10 TT LIFT E P1 AUTOMATIC=0 MANUAL=1 LIFT_E_P1_REM_MAN N7:61 SCADA_MAN_ON_OFF B3:0 0 9 0004 P1 HEAT SENSOR LIFT_E_P1_HEAT N7:0 P1 CURRENT SENSOR LIFTE_P1_STS I:0 5 6 Bul.1764 P1 HAS FAILED SCADA BIT LIFT_E_P1_FAILED N7:3 7 LIFT E P1 PUMP FAILURE TIMER T4:2 DN P1 START/STOP RELAY CR251 LIFTE_P1_SS O:0 0 Bul.1764 LIFT E P1 PUMP FAILURE TIMER TON Timer On Delay Timer Time Base Preset Accum Page 3 EN T4:2 1.0 30< 0< DN LIFT E P1 PUMP FAILURE TIMER T4:2 P1 HEAT SENSOR LIFT_E_P1_HEAT N7:0 P1_FAILED N7:3 DN 5 5 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 4 - PUMP1 --- Total Rungs in File = 9 P1 CURRENT SENSOR LIFTE_P1_STS I:0 6 Bul.1764 P1_FAILED N7:3 P1 HAS FAILED SCADA BIT LIFT_E_P1_FAILED N7:3 5 7 0005 P1 HAS FAILED SCADA BIT LIFT_E_P1_FAILED N7:3 P1 ALARM IS RESET INTERNAL BIT LIFTE_P1_ALARM_RESET B3:0 7 2 P1 HAS FAILED SCADA BIT LIFT_E_P1_FAILED N7:3 RESET P1 SCADA BIT LIFT_E_P1_RESET N7:62 P1 ALARM IS RESET INTERNAL BIT LIFTE_P1_ALARM_RESET B3:0 7 0 2 0006 P1 ALARM IS RESET INTERNAL BIT LIFTE_P1_ALARM_RESET B3:0 2 First Pass S:1 15 LIFTE_PUMP1_START B3:0 P1 START/STOP RELAY N7:3 10 0 0007 0008 Page 4 LIFT E P1 TWO MINUTE DELAY BEFORE P1 CAN RESTART TON Timer On Delay Timer T4:4 Time Base 1.0 Preset 300< Accum 20< EN DN END Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 5 - PUMP2 --- Total Rungs in File = 9 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT_E_P2_REM_MAN N7:61 3 1 0000 P2 LEAD P2_LEAD B3:1 LEVEL 1 FLOAT LIFT_E_WETWELL_LVL_1 N7:0 0 9 LIFT_E_LVL1_ALARM N7:2 LEVEL 2 FLOAT LIFT_E_WETWELL_LVL_2 N7:0 3 10 P1 LEAD P1_LEAD B3:0 LEVEL 2 FLOAT LIFT_E_WETWELL_LVL_2 N7:0 15 10 LIFTE_PUMP2_START B3:0 L 11 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT_E_P2_REM_MAN N7:61 LEVEL LOW/STOP PUMP LIFT_E_LVL_OFF N7:0 1 11 LIFTE_PUMP2_START B3:0 U 11 0001 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT_E_P2_REM_MAN N7:61 1 First Pass S:1 15 LIFT E SCADA P2 ON LIFT_E_SCADA_P2_ON N7:61 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT_E_P2_REM_MAN N7:61 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 6 1 3 0002 Page 1 B3:0 L 12 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 5 - PUMP2 --- Total Rungs in File = 9 N7:61 B3:0 U 12 0003 7 LIFT E P2 DISABLED =1 ENABLED =0 LIFT_E_P2_ENABLED N7:61 LIFTE_PUMP2_START B3:0 LIFT E P2 TWO MINUTE DELAY BEFORE P1 CAN RESTART T4:5 3 11 TT 0004 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT_E_P2_REM_MAN N7:61 B3:0 1 12 P2 HEAT SENSOR LIFT_E_P2_HEAT N7:0 P2 CURRENT SENSOR LIFTE_P2_STS I:0 7 8 Bul.1764 P2_FAILED N7:3 P2 START/STOP RELAY CR254 LIFTE_P2_SS O:0 6 1 Bul.1764 LIFT E P2 PUMP FAILURE TIMER T4:3 DN LIFT E P2 PUMP FAILURE TIMER TON Timer On Delay Timer Time Base Preset Accum EN T4:3 1.0 30< 0< DN LIFT E P2 PUMP FAILURE TIMER T4:3 P2 HEAT SENSOR LIFT_E_P2_HEAT N7:0 P2_FAILED N7:3 DN 7 6 P2 CURRENT SENSOR LIFTE_P2_STS I:0 8 Bul.1764 Page 2 Thursday, September 07, 2006 - 08:08:36 LIFTE.RSS LAD 5 - PUMP2 --- Total Rungs in File = 9 P2_FAILED N7:3 P2 HAS FAILED SCADA BIT LIFT_E_P2_FAILED N7:3 6 8 0005 P2 HAS FAILED SCADA BIT LIFT_E_P2_FAILED N7:3 P1 ALARM IS RESET INTERNAL BIT LIFTE_P2_ALARM_RESET B3:0 8 3 P2 HAS FAILED SCADA BIT LIFT_E_P2_FAILED N7:3 RESET P2 SCADA BIT LIFT_E_P2_RESET N7:62 P1 ALARM IS RESET INTERNAL BIT LIFTE_P2_ALARM_RESET B3:0 8 1 3 0006 P1 ALARM IS RESET INTERNAL BIT LIFTE_P2_ALARM_RESET B3:0 3 First Pass S:1 15 LIFTE_PUMP2_START B3:0 P2 START/STOP RELAY N7:3 11 1 0007 0008 Page 3 LIFT E P2 TWO MINUTE DELAY BEFORE P1 CAN RESTART TON Timer On Delay Timer T4:5 Time Base 1.0 Preset 300< Accum 20< EN DN END Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS LAD 6 - 0000 Page 1 --- Total Rungs in File = 1 END Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS LAD 7 - 0000 Page 1 --- Total Rungs in File = 1 END Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS LAD 8 - 0000 Page 1 --- Total Rungs in File = 1 END Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS LAD 9 - 0000 Page 1 --- Total Rungs in File = 1 END Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS LAD 10 - 0000 Page 1 --- Total Rungs in File = 1 END Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS Data File O0 (bin) Offset 15 14 13 12 11 10 O:0.0 O:0.1 O:0.2 O:0.3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 1 (Radix Binary) 0 0 0 0 -- OUTPUT 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Bul.1764 Bul.1764 Bul.1764 Bul.1764 Micrologix Micrologix Micrologix Micrologix 1500 1500 1500 1500 LRP LRP LRP LRP Series Series Series Series Thursday, September 07, 2006 - 08:08:37 LIFTE.RSS Data File I1 (bin) Offset 15 14 13 12 11 10 I:0.0 I:0.1 I:0.2 I:0.3 I:1.0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 1 (Radix Binary) 0 0 0 0 0 -- 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 INPUT Bul.1764 Micrologix 1500 LRP Bul.1764 Micrologix 1500 LRP Bul.1764 Micrologix 1500 LRP Bul.1764 Micrologix 1500 LRP 1769-IA16 - 16-Input 79/132 VAC Series Series Series Series Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File S2 (hex) -- STATUS Main Processor Mode S:1/0 - S:1/4 = Remote Run On Power up Go To Run (Mode Behavior) S:1/12 = 0 First Pass S:1/15 = No Free Running Clock S:4 = 0010-1001-1111-0010 Proc OS Catalog Number S:57 = 1510 OS Series S:58 = C OS FRS S:59 = Processor Catalog Number S:60 = Processor Series S:61 = A Processor FRN S:62 = User Program Type S:63 = 818h Compiler Revision Number S:64 = Scan Times Maximum (x10 ms) S:22 = 19 Watchdog (x10 ms) S:3 (high byte) = 10 Last 100 uSec Scan Time S:35 = 9 Scan Toggle Bit S:33/9 = 0 Math Math Overflow Selected S:2/14 = 0 Overflow Trap S:5/0 = 0 Carry S:0/0 = 0 Overflow S:0/1 = 0 Zero Bit S:0/2 = 0 Sign Bit S:0/3 = 0 Math Register (lo word) S:13 = 0 Math Register (high word) S:14-S:13 = 0 Math Register (32 Bit) S:14-S:13 = 0 Chan 0 Processor Mode S:1/0- S:1/4 = Remote Run Node Address S:15 (low byte) = 0 Baud Rate S:15 (high byte) = ? Channel Mode S:33/3 = 0 Comms Active S:33/4 = 0 Incoming Cmd Pending S:33/0 = 0 Msg Reply Pending S:33/1 = 0 Outgoing Msg Cmd Pending S:33/2 = 0 Debug Suspend Code S:7 = 0 Suspend File S:8 = 0 Errors Fault Override At Power Up S:1/8 = 0 Startup Protection Fault S:1/9 = 0 Major Error Halt S:1/13 = 0 Overflow Trap S:5/0 = 0 Control Register Error S:5/2 = 0 Major Error Executing User Fault Rtn. S:5/3 = 0 Battery Low S:5/11 = 0 Input Filter Selection Modified S:5/13 = 0 ASCII String Manipulation error S:5/15 = 0 Fault Routine S:29 = 0 Major Error S:6 = 0h Error Description: Protection Deny Future Access S:1/14 = No Data File Overwrite Protection Lost S:36/10 = False Page 1 Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File S2 (hex) -- STATUS Mem Module Memory Module Loaded On Boot S:5/8 = 0 Password Mismatch S:5/9 = 0 Load Memory Module On Memory Error S:1/10 = 0 Load Memory Module Always S:1/11 = 0 On Power up Go To Run (Mode Behavior) S:1/12 = 0 Program Compare S:2/9 = 0 Data File Overwrite Protection Lost S:36/10 = 0 Forces Forces Enabled S:1/5 = Yes Forces Installed S:1/6 = No Page 2 Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File B3 (bin) Offset 15 14 13 12 11 10 B3:0 B3:1 0 0 0 0 0 0 0 0 0 0 Page 1 (Radix Binary) 0 0 -- BINARY 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 1 (Symbol) Description Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File T4 Offset T4:0 T4:1 T4:2 T4:3 T4:4 T4:5 T4:6 T4:7 T4:8 T4:9 T4:10 T4:11 T4:12 T4:13 T4:14 T4:15 T4:16 T4:17 T4:18 T4:19 Page 1 EN TT DN 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 BASE 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 .01 .01 .01 .01 .01 .01 1.0 .01 .01 sec sec sec sec sec sec sec sec sec sec sec sec sec sec sec sec sec sec sec sec PRE ACC 3600 2 30 30 300 300 3 3 30 120 600 0 0 0 0 0 0 7 0 0 20 0 0 0 20 20 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -- TIMER (Symbol) Description (HOUR_TIMER) HOUR TIMER LIFT LIFT LIFT LIFT E E E E P1 P2 P1 P2 PUMP FAILURE TIMER PUMP FAILURE TIMER TWO MINUTE DELAY BEFORE P1 CAN RESTART TWO MINUTE DELAY BEFORE P1 CAN RESTART PANEL DOOR ALARM TIMER PANEL TEMP SWITCH TIMER LEVEL 1 FLOAT ALARM TIMER PUMP LEAD SET TIMER Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File C5 Offset C5:0 C5:1 C5:2 C5:3 C5:4 C5:5 C5:6 C5:7 C5:8 C5:9 Page 1 CU CD DN OV UN UA 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 PRE ACC 24 7 2 0 0 0 0 0 0 0 16 0 1 0 0 0 0 0 0 0 -- COUNTER (Symbol) Description (DAY_COUNTER) (WEEK_COUNTER) (ALTERNATE_LEAD) ALTERNATE LEAD Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File R6 Offset R6:0 Page 1 EN EU DN EM ER UL IN FD 0 0 0 0 0 0 0 0 LEN POS 0 0 -- CONTROL (Symbol) Description Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File N7 (dec) Offset N7:0 N7:10 N7:20 N7:30 N7:40 N7:50 N7:60 Page 1 -- INTEGER 0 1 2 3 4 5 6 7 8 9 160 0 0 0 0 0 0 1 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (Radix Decimal) Thursday, September 07, 2006 - 08:08:38 LIFTE.RSS Data File F8 -- FLOAT Offset 0 1 2 3 4 F8:0 F8:5 0 0 0 0 0 0 0 0 0 0 Page 1 Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Data File T40 Offset T40:0 T40:1 Page 1 EN TT DN 0 0 0 0 0 0 BASE PRE ACC .01 sec .01 sec 0 30 0 0 (Symbol) Description WEEK COUNTER RESETTING TIMER Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS CDM 0 - Untitled Address (Symbol) = Value [Description] Page 1 Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Address/Symbol Database Address Symbol Scope B3:0/0 B3:0/2 B3:0/3 B3:0/5 B3:0/9 B3:0/10 B3:0/11 B3:0/15 B3:1/0 B3:1/1 C5:0 C5:1 C5:2 C5:2.ACC I:0/0 I:0/1 I:0/2 I:0/3 I:0/4 I:0/5 I:0/6 I:0/7 I:0/8 I:0/9 I:0/10 I:0/11 I:1.0 I:1/0 I:1/1 I:1/2 I:1/3 N7:0/0 N7:0/1 N7:0/2 N7:0/3 N7:0/4 N7:0/5 N7:0/6 N7:0/7 N7:0/8 N7:0/9 N7:0/10 N7:0/11 N7:0/12 N7:0/14 N7:1/0 N7:1/1 N7:2/0 N7:2/1 N7:2/2 N7:2/3 N7:2/14 N7:2/15 N7:3/0 N7:3/1 N7:3/2 N7:3/5 N7:3/6 N7:3/7 N7:3/8 N7:61/0 N7:61/1 N7:61/2 N7:61/3 N7:61/4 N7:61/5 N7:61/6 N7:62/0 N7:62/1 O:0/0 O:0/1 O:0/2 S:0 S:0/0 S:0/1 S:0/2 WEEKLY_CHANGE_BIT LIFTE_P1_ALARM_RESET LIFTE_P2_ALARM_RESET P1_P2_ENABLED SCADA_MAN_ON_OFF LIFTE_PUMP1_START LIFTE_PUMP2_START P1_LEAD P2_LEAD P1_P2_SET_LEAD DAY_COUNTER WEEK_COUNTER ALTERNATE_LEAD ALTERNATE_LEAD_ACC LIFTE_AC_FAIL LIFTE_UPS_FAIL LIFTE_V_V_ALA LIFTE_LO_LO_ALM LIFTE_HI_HI_ALM LIFTE_P1_FAIL LIFTE_P1_STS LIFTE_P2_FAIL LIFTE_P2_STS LIFTE_WETWELL_LVL_1 LIFTE_WETWELL_LVL_2 LIFTE_PUMPS_OFF Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global LIFTE_DOOR_ALARM LIFTE_ICE_CUBE_ALARM LIFTE_P1_SEAL_FAIL LIFTE_P2_SEAL_FAIL LIFT_E_AC_ALARM LIFT_E_UPS_FAIL LIFT_E_P1_SEAL LIFT_E_P2_SEAL LIFT_E_HI_HI_ALAM LIFT_E_P1_HEAT LIFT_E_P1_STS LIFT_E_P2_HEAT LIFT_E_P2_STS LIFT_E_WETWELL_LVL_1 LIFT_E_WETWELL_LVL_2 LIFT_E_LVL_OFF LIFT_E_V_V_ALA LIFT_E_LO_LO_ALARM LIFT_E_DOOR_ALARM LIFT_E_ICE_CUBE_ALA LIFT_E_FIX_PLC_ALARM LIFT_E_FIX_P1_LEAD LIFT_E_FIX_P2_LEAD LIFT_E_LVL1_ALARM LIFT_E_SET_P1_LEAD LIFT_E_SET_P2_LEAD Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Page 1 Description Sym Group Dev. Co P1 ALARM IS RESET INTERNAL BIT P1 ALARM IS RESET INTERNAL BIT P1 P2 ENABLED P1 LEAD P2 LEAD P1 P2 SET LEAD ALTERNATE LEAD ALTERNATE LEAD ACC CR3 / FU204 POWER FAILURE / CR211 UPS FAILURE VALVE VAULT ALARM CR5 LOW LEVEL FLOAT ALAR AR / CR373 HIGH LEVEL FLOAT ALA CR11 P1 HEAT FAIL SENSOR P1 CURRENT SENSOR CR13 P2 HEAT FAIL SENSOR P2 CURRENT SENSOR CR7 / CR365 LEVEL 1 FLOAT CR8 / CR369 LEVEL 2 FLOAT CR6 / CR359 STOP PUMPS FLOAT PANEL DOOR SWTCH PANEL TEMP SWTCH CR10 P1 SEAL FAIL SENSOR CR12 P2 SEAL FAIL SENSOR P1 SEAL FAIL ALARM P2 SEAL FAIL ALARM HIGH LEVEL ALARM P1 HEAT SENSOR P1 CURRENT SWITCH P2 HEAT SENSOR P2 CURRENT SWITCH LEVEL 1 FLOAT LEVEL 2 FLOAT LEVEL LOW/STOP PUMP VALVE VAULT ALARM LOW LEVEL ALARM PANEL DOOR OPEN PANEL TEMPERATURE PLC ALARM P1 START/STOP RELAY P2 START/STOP RELAY RED STATUS LIGHT P1_FAILED P2_FAILED LIFT_E_P1_FAILED LIFT_E_P2_FAILED LIFT_E_P1_REM_MAN LIFT_E_P2_REM_MAN LIFT_E_P1_ENABLED LIFT_E_P2_ENABLED LIFT_E_SCADA_P1_ON LIFT_E_SCADA_P1_OFF LIFT_E_SCADA_P2_ON LIFT_E_P1_RESET LIFT_E_P2_RESET LIFTE_P1_SS LIFTE_P2_SS LIFTE_STATUS_LAMP Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global Global P1 HAS FAILED SCADA BIT P2 HAS FAILED SCADA BIT LIFT E P1 AUTOMATIC=0 MANUAL=1 LIFT E P2 AUTOMATIC=0 MANUAL=1 LIFT E P1 DISABLED=1 ENABLED=0 LIFT E P2 DISABLED =1 ENABLED =0 LIFT E SCADA P1 ON LIFT E SCADA P1 OFF LIFT E SCADA P2 ON RESET P1 SCADA BIT RESET P2 SCADA BIT P1 START/STOP RELAY CR251 P2 START/STOP RELAY CR254 STATUS RED LIGHT LT257 Arithmetic Flags Processor Arithmetic Carry Flag Processor Arithmetic Underflow/ Overflow Flag Processor Arithmetic Zero Flag Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Address/Symbol Database Address S:0/3 S:1 S:1/0 S:1/1 S:1/2 S:1/3 S:1/4 S:1/5 S:1/6 S:1/7 S:1/8 S:1/9 S:1/10 S:1/11 S:1/12 S:1/13 S:1/14 S:1/15 S:2/0 S:2/1 S:2/2 S:2/3 S:2/4 S:2/5 S:2/6 S:2/7 S:2/15 S:3 S:4 S:5/0 S:5/2 S:5/3 S:5/4 S:5/8 S:5/9 S:5/10 S:5/11 S:6 S:7 S:8 S:9 S:10 S:11 S:12 S:13 S:14 S:15 S:16 S:17 S:18 S:19 S:20 S:21 S:22 S:23 S:24 S:25 S:26 S:27 S:28 S:29 S:30 S:31 S:32 S:33 S:33/0 S:33/1 S:33/2 S:33/3 S:33/4 S:33/5 S:33/6 S:33/7 S:33/8 S:33/9 S:33/10 Page 2 Symbol S Scope Global Description Sym Group Dev. Co Processor Arithmetic Sign Flag Processor Mode Status/ Control Processor Mode Bit 0 Processor Mode Bit 1 Processor Mode Bit 2 Processor Mode Bit 3 Processor Mode Bit 4 Forces Enabled Forces Present Comms Active Fault Override at Powerup Startup Protection Fault Load Memory Module on Memory Error Load Memory Module Always Load Memory Module and RUN Major Error Halted Access Denied First Pass STI Pending STI Enabled STI Executing Index Addressing File Range Saved with Debug Single Step DH-485 Incoming Command Pending DH-485 Message Reply Pending DH-485 Outgoing Message Command Pending Comms Servicing Selection Current Scan Time/ Watchdog Scan Time Time Base Overflow Trap Control Register Error Major Err Detected Executing UserFault Routine M0-M1 Referenced on Disabled Slot Memory Module Boot Memory Module Password Mismatch STI Overflow Battery Low Major Error Fault Code Suspend Code Suspend File Active Nodes Active Nodes I/O Slot Enables I/O Slot Enables Math Register Math Register Node Address/ Baud Rate Debug Single Step Rung Debug Single Step File Debug Single Step Breakpoint Rung Debug Single Step Breakpoint File Debug Fault/ Powerdown Rung Debug Fault/ Powerdown File Maximum Observed Scan Time Average Scan Time Index Register I/O Interrupt Pending I/O Interrupt Pending I/O Interrupt Enabled I/O Interrupt Enabled User Fault Routine File Number STI Setpoint STI File Number I/O Interrupt Executing Extended Proc Status Control Word Incoming Command Pending Message Reply Pending Outgoing Message Command Pending Selection Status User/DF1 Communicat Active Communicat Servicing Selection Message Servicing Selection Channel 0 Message Servicing Selection Channel 1 Interrupt Latency Control Flag Scan Toggle Flag Discrete Input Interrupt Reconfigur Flag Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Address/Symbol Database Address S:33/11 S:33/12 S:33/13 S:33/14 S:33/15 S:34 S:34/0 S:34/1 S:34/2 S:35 S:36 S:36/8 S:36/9 S:36/10 S:37 S:38 S:39 S:40 S:41 S:42 S:43 S:44 S:45 S:46 S:47 S:48 S:49 S:50 S:51 S:52 S:53 S:54 S:55 S:56 S:57 S:58 S:59 S:61 S:62 S:63 S:64 S:65 S:66 S:67 S:68 S:69 S:70 S:71 S:72 S:73 S:74 S:75 S:76 S:77 S:78 S:79 S:80 S:81 S:82 S:83 S:84 S:85 S:86 T4:0 T4:2 T4:3 T4:4 T4:5 T4:8 T4:9 T4:10 T4:17 T4:17/DN T40:1 U:3 U:4 Page 3 Symbol HOUR_TIMER Scope Global Description Sym Group Dev. Co Online Edit Status Online Edit Status Scan Time Timebase Selection DTR Control Bit DTR Force Bit Pass-thru Disabled Pass-Thru Disabled Flag DH+ Active Node Table Enable Flag Floating Point Math Flag Disable Last 1 ms Scan Time Extended Minor Error Bits Dll Lost STI Lost Memory Module Data File Overwrite Protection Clock Calendar Year Clock Calendar Month Clock Calendar Day Clock Calendar Hours Clock Calendar Minutes Clock Calendar Seconds STI Interrupt Time I/O Event Interrupt Time Dll Interrupt Time Discrete Input Interrupt- File Number Discrete Input Interrupt- Slot Number Discrete Input Interrupt- Bit Mask Discrete Input Interrupt- Compare Value Processor Catalog Number Discrete Input Interrupt- Return Number Discrete Input Interrupt- Accumulat Discrete Input Interrupt- Timer Discrete Input Interrupt- Timer Last Dll Scan Time Maximum Observed Dll Scan Time Operating System Catalog Number Operating System Series Operating System FRN Processor Series Processor Revision User Program Type User Program Functional Index User RAM Size Flash EEPROM Size Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes Channel 0 Active Nodes DH+ Active Nodes DH+ Active Nodes DH+ Active Nodes DH+ Active Nodes HOUR TIMER LIFT E P1 PUMP FAILURE TIMER LIFT E P2 PUMP FAILURE TIMER LIFT E P1 TWO MINUTE DELAY BEFORE P1 CAN RESTART LIFT E P2 TWO MINUTE DELAY BEFORE P1 CAN RESTART PANEL DOOR ALARM TIMER PANEL TEMP SWITCH TIMER LEVEL 1 FLOAT ALARM TIMER PUMP LEAD SET TIMER WEEK COUNTER RESETTING TIMER TIME BASE SUBROUTINE PUMP 1 SUBROUTINE Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Address/Symbol Database Address U:5 Page 4 Symbol Scope Description Sym Group Dev. Co PUMP 2 SUBROUTINE Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Instruction Comment Database Address Page 1 Instruction Description Thursday, September 07, 2006 - 08:08:39 LIFTE.RSS Symbol Group Database Group_Name Page 1 Description Thursday, September 07, 2006 - 08:08:40