Controller Ceiling-Mounted RF Receiver rta-rx-f-sc-1 03.17.07 RadioTouchTM Controller for Lights, Sivoia QEDTM Controllable Window Shading System, and Contact Closures RTA-RX-F-SC RTA-RX-F-SC-347 RadioTouch RTA-RX-F-SC 120/277 V 16 A Max. TM PROG STAT 100 Hr/100% ON CCO 3 CCO Com _ 0-10 V 9 10 11 12 13 14 15 16 CCO 2 PS S ig ® 8 CCO 5 6 7 CCO 4 5 CCO 1 4 + 3 Cir Com 1 2 15 V 5 24 V 4 Occ S ig 3 Occ. Com 2 PELV (Class 2: USA) 1 P/N 500-10634 © 2006 Lutron Electronics Co., Inc. CONFIGURACIONES REGLAGES PWR SETTINGS ® Refer to the Installers Guide for more detailed instructions. Consulte la Guía de Instaladores para información más detallada. Référer au Guide d’installation pour plus de renseignements détaillés. 1-800-523-9466 1-888-235-2910 USA, Canada Mexico www.lutron.com Description The RadioTouch lights, Sivoia QED ultra-quiet controllable window shading system, and contact closure controller is designed to work in conjunction with RadioTouch transmitters that have been addressed to the controller. The controller can be addressed to respond to signals from up to 16 RadioTouch transmitters. The controller has the ability to control Lutron Hi-lume® and ECO-10TM ballasts directly. The controller can be connected to a Lutron FDI interface to dim Lutron Tu-wireTM ballasts, incandescent, magnetic low-voltage, and electronic low-voltage loads. 60 Hz LISTED 243C Ind. Cont. E q. Coopersburg, PA 18036 USA The controller mounts to a standard 4 x 4 in. (120 x 120 mm) junction box or to the knockout of a fluorescent fixture. The controller can directly accept inputs from standard 15 and 24 V occupant sensors as well as Lutron’s MW-PS-WH and MW-FPS-WH daylight sensors. The controller operates at either 120/277 V or 347 V , depending on the model number. The controller can communicate with Lutron’s Sivoia QED ultra-quiet controllable window shading system through a SVQ-CCI-8 interface. It also has the ability to provide up to five momentary dry contact closures, and control AC shade and projection screen motors through a group control interface. Ratings Model Number RTA-RX-F-SC RTA-RX-F-SC-347 R Voltage 120 or 277 V 347 V Maximum Current 16 A (20 A breaker) 16 A (20 A breaker) S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Switch Closure Maximums 30 V 1/3 A 30 V 1/3 A Page 1 Controller Ceiling-Mounted RF Receiver rta-rx-f-sc-2 03.17.07 Dimensions RadioTouch RTA-RX-F-SC 120/277 V 16 A Max. TM Coopersburg, PA 18036 USA PROG STAT 100 Hr/100% ON 5 CCO 3 CCO Com CCO 2 9 10 11 12 13 14 15 16 8 CCO 5 6 7 CCO 1 5 CCO 4 4 + 15 V Occ S ig Occ. Com 3 _ 1 2 PS S ig 4 24 V 3 Cir Com 2 PELV (Class 2: USA) 1 0-10 V ® P/N 500-10634 © 2006 Lutron Electronics Co., Inc. CONFIGURACIONES REGLAGES PWR SETTINGS ® Refer to the Installers Guide for more detailed instructions. Consulte la Guía de Instaladores para información más detallada. Référer au Guide d’installation pour plus de renseignements détaillés. 1-800-523-9466 1-888-235-2910 USA, Canada Mexico www.lutron.com 60 Hz LISTED 243C Ind. Cont. E q. 7.75 in. (197 mm) ON 1 2 3 4 5 1 TX 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RX 4 in. (100 mm) 2.5 in. (17.8 mm) Mounting Using two screws, mount the unit to a 4 x 4 in. (120 x 120 mm) junction box or directly to a wall (screws and wall anchors are provided) as shown. R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Features • Provides direct control of a full circuit of Lutron Hi-lume® and ECO-10TM ballasts. • Capable of switching 16 amps of Lutron ballasts. • Provides control of Lutron Tu-wireTM ballasts, incandescent, magnetic low-voltage, and electronic low-voltage loads using an FDI load interface. • RTA-RX-F-SC operates at 120 or 277 V line voltage. • RTA-RX-F-SC-347 operates at 347 V line voltage. • Each controller can be programmed to accept control information from 16 unique RadioTouch transmitters. • Accepts inputs from standard 15 and 24 V occupant sensors and provides power to them (not to exceed 30 mA). • One required per lighting zone to be controlled. • Accepts an input from a Lutron MW-PS-WH or MW-FPS-WH daylight sensor to regulate the electric light based on the presence or absence of sunlight and provides power to the sensor (not to exceed 30 mA). • Accepts control signals from RadioTouch transmitters at 418 MHz. • Provides a burn-in function to assist in the seasoning of new fluorescent bulbs for 100 hours. • Mounts to a standard 4 x 4 in. (120 x 120 mm) junction box or to the knockout of a fluorescent fixture. • Provides up to five momentary dry low-voltage contact closures. • Communicates with Lutron’s Sivoia QEDTM ultraquiet controllable window treatments through contact closure outputs and a SVQ-CCI-8 Sivoia QED interface. • Requires a group control interface to operate AC shades and projection screen motors. Page 2 Controller Ceiling-Mounted RF Receiver rta-rx-f-sc-3 03.17.07 Power Wiring Diagram Green White Black (120 V Black/Red Ground Neutral Switched Hot (blue) Dimmed Hot (orange) ) Distribution panel RadioTouch RTA-RX-F-SC 120/277 V 16 A Max. TM LISTED 243C Ind. Cont. E q. Coopersburg, PA 18036 USA PROG ® 100 Hr/100 ® CCO 4 9 10 11 12 13 14 15 16 CCO 5 _ 0-10 V CCO Com 8 + 6 7 CCO 3 5 CCO 2 4 CCO 1 15 V 3 PS S ig 5 24 V 4 1 2 Occ S ig 3 Cir Com 2 Occ. Com 1 Lutron FDB or ECO dimming ballast P/N 500-10634 © 2006 Lutron Electronics Co., Inc. STAT ON PELV (Class 2: USA) Ground Neutral Hot CONFIGURACIONES REGLAGES PWR SETTINGS Fixture ground Refer to the Installers Guide for more detailed instructions. Consulte la Guía de Instaladores para información más detallada. Référer au Guide d’installation pour plus de renseignements détaillés. 1-800-523-9466 1-888-235-2910 USA, Canada Mexico www.lutron.com 60 Hz Green White Black Orange Fixture ground Green White Black Orange Red (277/347 V ) Cap the wire that is not being used (red or black, depending on voltage) Lutron FDB or ECO dimming ballast To additional dimming ballasts R S P E C I F I C AT I O N S U B M I T TA L Job Name: Job Number: Model Numbers: Page 3