Preview only show first 10 pages with watermark. For full document please download

Runtime Charts Eaton 93e 15-80kva Ups Eaton 93e 15

   EMBED


Share

Transcript

Runtime Charts Eaton 93E 15-80kVA UPS Eaton 93E 15-80 kVA UPS on-battery runtimes with different load ratings Contents 93E 15kVA UPS .........................................................................................................................................................2 Internal batteries ..................................................................................................................................................2 External batteries .................................................................................................................................................2 93E 20kVA UPS .........................................................................................................................................................3 Internal batteries ..................................................................................................................................................3 External batteries .................................................................................................................................................3 93E 30kVA UPS .........................................................................................................................................................4 Internal batteries ..................................................................................................................................................4 External batteries .................................................................................................................................................4 93E 40kVA UPS .........................................................................................................................................................5 Internal batteries ..................................................................................................................................................5 External batteries .................................................................................................................................................5 93E 60kVA UPS .........................................................................................................................................................5 External Batteries .................................................................................................................................................5 93E 80kVA UPS .........................................................................................................................................................7 External batteries .................................................................................................................................................7 Battery cabinet specifications ..................................................................................................................................9 Page 1 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS 93E 15kVA UPS Internal batteries Power factor 0.8 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 2x32 3 kVA 88 5k VA 44 10 kVA 22 12kVA 17 15 kVA 13 3 kVA 79 5k VA 44 10 kVA 19 12kVA 15 15 kVA 11 Power factor 0.9 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 2x32 External batteries Power factor 0.8 on different load levels Battery Battery 9Ah Battery 9Ah Battery 9Ah Battery 9Ah Quantity 3x32 4x32 5x32 6x32 3 kVA 148 207 271 332 5k VA 80 111 148 179 10 kVA 36 51 64 80 12kVA 29 40 53 64 15 kVA 22 30 40 51 Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL 2x32 3x32 4x32 5x32 6x32 84 136 205 277 355 51 75 102 136 173 21 37 51 67 81 16 29 41 54 67 11 21 31 41 51 Power factor 0.9 on different load levels Battery Battery 9Ah Battery 9Ah Battery 9Ah Battery 9Ah Quantity 3x32 4x32 5x32 6x32 3 kVA 126 177 235 291 5k VA 70 95 126 160 10 kVA 30 44 57 70 12kVA 25 35 46 57 15 kVA 19 27 35 44 Battery 7Ah LL Battery 7Ah LL 2x32 3x32 74 115 45 64 17 31 13 25 9 17 Page 2 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL 4x32 5x32 6x32 171 241 295 88 115 150 44 58 72 36 46 58 27 36 44 5 kVA 51 10 kVA 22 12 kVA 17 15 kVA 13 20 kVA 9 5 kVA 44 10 kVA 19 12 kVA 15 15 kVA 11 20 kVA 8 5 kVA 80 111 148 179 10 kVA 36 51 64 80 12 kVA 29 40 53 64 15 kVA 22 30 40 51 20 kVA 15 22 29 36 51 75 102 136 173 22 37 51 59 75 16 29 41 54 67 11 21 31 41 51 7 13 21 29 37 5 kVA 70 95 10 kVA 30 44 12 kVA 25 35 15 kVA 19 27 20 kVA 13 19 93E 20kVA UPS Internal batteries Power factor 0.8 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 2x32 Power factor 0.9 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 2x32 External batteries Power factor 0.8 on different load levels Battery Battery 9Ah Battery 9Ah Battery 9Ah Battery 9Ah Quantity 3x32 4x32 5x32 6x32 Battery 7Ah LL 2x32 Battery 7Ah LL 3x32 Battery 7Ah LL 4x32 Battery 7Ah LL 5x32 Battery 7Ah LL 6x32 Power factor 0.9 on different load levels Battery Battery 9Ah Battery 9Ah Quantity 3x32 4x32 Page 3 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS Battery 9Ah Battery 9Ah 5x32 6x32 126 160 57 70 46 57 35 44 25 30 Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL Battery 7Ah LL 2x32 3x32 4x32 5x32 6x32 45 64 88 115 150 18 30 45 55 64 13 25 36 46 58 9 17 27 36 44 4 11 17 25 31 10 kVA 36 15 kVA 22 20 kVA 15 25 kVA 12 30 kVA 9 10 kVA 30 15 kVA 19 20 kVA 13 25 kVA 10 30 kVA 8 93E 30kVA UPS Internal batteries Power factor 0.8 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 3x32 Power factor 0.9 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 3x32 External batteries Power factor 0.8 on different load levels Battery CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W Power factor 0.9 Quantity 1x32 2x32 3x32 4x32 10 kVA 110 230 371 485 15 kVA 69 153 230 315 20 kVA 47 110 171 230 25 kVA 35 86 135 179 30 kVA 27 69 110 153 Battery CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W Quantity 1x32 2x32 3x32 10 kVA 97 204 315 15 kVA 58 133 204 20 kVA 40 97 153 25 kVA 29 75 117 30 kVA 24 58 97 Page 4 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS CSB HRL 12200 200W 4x32 441 276 204 163 133 10 kVA 51 15 kVA 30 20 kVA 22 30 kVA 13 40 kVA 9 10 kVA 44 15 kVA 27 20 kVA 19 30 kVA 11 40 kVA 8 Battery Quantity CSB HRL 12200 200W 1x32 CSB HRL 12200 200W 2x32 CSB HRL 12200 200W 3x32 CSB HRL 12200 200W 4x32 Power factor 0.9 on different load levels 10 kVA 110 230 371 485 15 kVA 69 153 230 315 20 kA 47 110 171 230 30 kVA 27 69 110 153 40 kVA 18 47 80 110 Battery CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W 10 kVA 97 204 315 441 15 kVA 58 133 204 276 20 kVA 40 97 153 204 30 kVA 24 58 97 133 40 kVA 15 40 69 97 20 kVA 23 30 kVA 13 40 kVA 8 50 kVA 5 60 kVA - 93E 40kVA UPS Internal batteries Power factor 0.8 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 4x32 Power factor 0.9 on different load levels Battery Yuasa NPW45-12 9Ah Quantity 4x32 External batteries Power factor 0.8 on different load levels Quantity 1x32 2x32 3x32 4x32 93E 60kVA UPS External Batteries Power factor 0.8 on different load levels Battery CSB HRL 12110 110W Quantity 1x36 Page 5 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS CSB HRL 12110 110W CSB HRL 12110 110W CSB HRL 12110 110W 2x36 3x36 4x36 60 98 131 33 60 86 23 42 60 17 28 46 13 23 33 CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W 1x36 2x36 3x36 4x36 54 120 188 256 31 80 120 168 21 54 90 120 15 40 70 97 11 31 54 80 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 1x36 2x36 3x36 4x36 61 147 245 333 38 96 147 211 26 61 107 147 18 47 84 113 14 38 61 96 Power factor 0.9 on different load levels Battery CSB HRL 12110 110W CSB HRL 12110 110W CSB HRL 12110 110W CSB HRL 12110 110W Quantity 1x36 2x36 3x36 4x36 20 kVA 20 53 86 117 30 kVA 10 28 53 76 40 kVA 6 20 33 53 50 kVA 4 14 25 38 60 kVA 10 20 28 CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W 1x36 2x36 3x36 4x36 47 109 168 226 27 69 109 150 18 47 80 109 13 34 59 86 9 27 47 69 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 1x36 2x36 3x36 4x36 54 123 211 288 33 83 123 176 21 54 96 123 15 41 70 102 12 33 54 83 Page 6 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS 93E 80kVA UPS External batteries Power factor 0.8 on different load levels Battery CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W Quantity 1x36 2x36 3x36 4x36 1x40 2x40 3x40 4x40 20 kVA 54 120 188 256 62 139 212 286 30 kVA 31 80 120 168 37 89 139 185 40 kVA 21 54 90 120 25 62 102 139 60 kVA 11 31 54 80 14 37 62 89 80 kVA 6 21 37 54 8 25 43 62 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 1x36 2x36 3x36 4x36 1x40 2x40 3x40 4x40 61 147 245 333 75 166 273 382 38 96 147 211 43 106 166 242 26 61 107 147 29 75 116 166 14 38 61 96 16 43 75 106 9 26 44 61 10 29 50 75 Power factor 0.9 on different load levels Battery CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W CSB HRL 12200 200W Quantity 1x36 2x36 3x36 4x36 1x40 2x40 3x40 4x40 20 kVA 47 109 168 226 53 119 185 252 30 kVA 27 69 109 150 30 79 119 166 40 kVA 18 47 80 109 20 53 89 119 60 kVA 9 27 47 69 11 30 53 79 80 kVA 18 31 47 6 20 37 53 Exide XP12V1800 Exide XP12V1800 1x36 2x36 54 123 33 83 21 54 12 33 8 21 Page 7 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 Exide XP12V1800 3x36 4x36 1x40 2x40 3x40 4x40 211 288 60 144 242 327 123 176 38 94 144 207 96 123 25 60 106 144 The battery backup table is given with end voltage 1.7 VPC and UPS efficiency of 92%. Note! The specifications are subject to change without a notice. Page 8 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 54 83 13 38 60 94 38 54 9 25 43 60 Runtime Charts Eaton 93E 15-80kVA UPS Battery cabinet specifications Table 1. Eaton 93E 1580kVA compatible battery cabinet specifications 1 Cabinet (P/N) Model Breaker rating P-105000041-001 P-105000041-002 P-105000041-003 P-105000041-004 P-105000041-005 P-105000042-001 93P/E-63A 93P/E-63A 93P/E-63A 93P/E-63A 93P/E-63A 93P/E-160A 63A 63A 63A 63A 63A 160A P-105000042-002 93P/E-160A 160A P-105000017-001 93P/E-200A 200A P-105000017-002 93P/E-200A 200A P-105000017-004 93P/E-200A 200A P-105000017-005 P-105000017-006 P-105000017-007 P-105000018-001 93P/E-200A 93P/E-200A 93P/E-200A 93P/E-400A 200A 200A 200A 400A P-105000018-002 93P/E-400A 400A P-105000018-003 93P/E-400A 400A P-105000018-004 P-105000018-005 93P/E-400A 93P/E-400A 400A 400A Battery EMPTY Battery 9Ah Battery 9Ah Battery 7Ah LL Battery 7Ah LL EMPTY CSB HRL 12200 200W EMPTY M5 cables CSB HRL 12110 110W CSB HRL 12200 200W EMPTY M6 cables Exide P12V875 Exide XP12V1800 EMPTY M6 cables CSB HRL 12200 200W CSB HRL 12200 200W Exide XP12V1800 Exide XP12V1800 Battery Design life Blocks1 Used with 5 years 5 years 10 years 10 years - 3 x 32 2 x 32 3 x 32 2 x 32 3 x 32 1 x 32 93E 15-20kVA 93E 15-20kVA 93E 15-20kVA 93E 15-20kVA 93E 15-20kVA 93E 30-40kVA 10 years 1 x 32 93E 30-40kVA - 1 x 32-36 93E 60kVA 10 years 1 x 36 93E 60kVA 10 years 1 x 36 93E 60kVA 10 years 10 years 1 x 32-36 1 x 36 1 x 36 1 x 32-40 93E 60kVA 93E 60kVA 93E 60kVA 93E 80kVA 10 years 1 x 36 93E 80kVA 10 years 1 x 40 93E 80kVA 10 years 10 years 1 x 36 1 x 40 93E 80kVA 93E 80kVA Amount of battery blocks that are provided with the cabinet or can be installed in the battery cabinet (if empty). Page 9 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS Figure 1. 93P/E-63A Battery cabinet. Values are in millimetres. Figure 2. 93P/E-160A Battery cabinet. Values are in millimetres. Page 10 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002 Runtime Charts Eaton 93E 15-80kVA UPS Figure 3. 93P/E-200A 93P/E-400A Battery cabinet. Values are in millimetres. Page 11 of 11 Updated: 29.10.2015 Document: Eaton 93E 15-80kVA Runtime chart Rev002