Rx Series 5 C O N C E N T R A T...

   EMBED


Share

Transcript

ENERGY RECOVERY VENTILATORS MODEL RX5 SERIES Concentrating what we can do. more, ever and definitely... HEAD OFFICE : MITSUBISHI DENKI BLDG., 2-2-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN http://Global.MitsubishiElectric.com Y08-003 Nov.2008(MEE) Specifications subject to change without notice. Simple and Effective Excellent air quality and unbeatable Heat Exchange Efficiency LOSSNAY's Energy Recovery Technology and Simultaneous Ventilations (Supply and Exhaust) Contribute to Excellent Indoor air Quality and Significantly Reduce the Outdoor air load. Energy-Recovery Concept by Hyper Eco LOSSNAY Core In summer In winter Temperature difference between air supply and room: 1.7 ºC About 4kg/h of water vapor is recovered. Supply air Supply air LOSSNAY Conventional ventilator Try blowing into a rolled up piece of paper. The warmth of your breath travels through the paper to your hands. Dry bulb temperature (ºC) 27.7 33 Absolute humidity (g/kg'(DA)) 13.4 20.1 Relative humidity (%) 58 63 Enthalpy (kJ/kg(DA)) 62.1 84.6 Total heat recovered (kW) 7.5 0 Outdoor air load (kW) 3.1 10.6 Outdoor air load ratio (%) 71 100 LOSSNAY Conventional ventilator Exhaust air Room air Absolute humidity Air conditioner 26ºC Dry bulb temperature 10.5g/kg'(DA) Absolute humidity 50% Relative humidity Relative humidity Enthalpy problems arising in the workplace or in the home. It is believed to contribute to a significant loss in productivity, low morale and Heat exchange unit (LOSSNAY core) higher rates of sickness among many employees. The object of providing good Stale exhaust air ventilation alongside air condition in residential and commercial buildings is to Fresh air from outside 52.9kJ/kg(DA) Enthalpy 20.1g/kg'(DA) 63% 84.6kJ/kg(DA) { } Stale room air extracted the recovery of waste energy. The units reduce overall energy costs by extracting stale air and then recovering the heating or incoming fresh air. By utilising this energy, the LOSSNAY Core Construction & Principle Stale air exhaust (dirty indoor-air) EA Fresh air exhaust (fresh heating/cooling air) SA Indoors initial capital costs of heating and cooling OA Fresh air induction (fresh air) 1 50 29.2 4.7 Total heat recovered (kW) 8.2 0 Outdoor air load (kW) 3.1 11.3 Outdoor air load ratio (%) 72.5 100 Exhaust air Room air Dry bulb temperature Air conditioner Absolute humidity Relative humidity Enthalpy Outdoor air 20ºC Dry bulb temperature 7.3g/kg'(DA) Absolute humidity 50% Relative humidity 38.5kJ/kg(DA) Enthalpy 0ºC 1.9g/kg'(DA) 50% 4.7kJ/kg(DA) { Indoor supply-air Indoor _ Outdoor = × Temp recovery + Outdoor temperature (ºC) temperature (ºC) temperature (ºC) efficiency (%) temperature (ºC) Calculation example : 16ºC=(20ºC _ 0ºC)×80%+0ºC } The remarkable technology that permits the intake of fresh air with minimal loss to indoor temperature is know as the LOSSNAY Core. The cross-flow, plate-fin structure of the energy-recovery unit along with a specially processed diaphragm keep supply and exhaust air separate, ensuring that only fresh air is introduced to the indoor environment while also allowing for the efficient transfer of heat. The improvements Outdoors LOSSNAY system can save up to 30% on plant. 46 Enthalpy (kJ/kg(DA)) The basic principle cooling energy to either warm and cool Fresh air supply to the room Relative humidity (%) Every building needs a supply of fresh air to keep its inhabitants healthy and comfortable. Outdoor air though is rarely, if ever, , the same temperature as that maintained by the building s air conditioning system. In the summer, it is too hot. In the winter, it is too cold. This puts added stress on the air conditioner to compensate for the intake of the hot or cold air adding to the expense of operating the system. LOSSNAY all but eliminates this problem with original energy-recovery technology that uses the heat of the stale indoor air to be expelled in order to either heat or cool the incoming fresh air to a temperature much closer to the existing indoor air. This process reduces the load on the air conditioning system without cutting off the supply of vitally necessary fresh air. live and work comfort and safety. years, the LOSSNAY system has perfected 1.9 Energy-recovery calculating equation Indoor supply-air Outdoor Temp recovery _ Indoor _ Outdoor temperature (ºC) = temperature (ºC) temperature (ºC) temperature (ºC) × efficiency (%) Calculation example : 27.7ºC=33ºC_(33ºC _ 26ºC)×76% * The above applies to the case of LGH-100RX5 (High notch). provide conditions under which people can Developed and refined over the past 30 0 5.2 33ºC Energy-recovery calculating equation Poor air quality can be attributed to many 16 Absolute humidity (g/kg'(DA)) Outdoor air Dry bulb temperature Some 38 years ago, that simple principle led to the development of our most advanced air-conditioning technology. Dry bulb temperature (ºC) RA Stale air induction (dirty heating/cooling air) The microscopically small pores of the diaphragm have been made even smaller, decreasing the rate at which water soluble gases such as ammonia and hydrogen pass through. Further, a new specially processed paper used to make the diaphragm has been developed with high moisture permeability characteristics that aid in the transference of moisture for improved energy exchange efficiency. These developments further improve moisture permeability and effectiveness in shielding unwanted gases, resulting in a lower rate of gas transference and more highly efficient energy transfer. 2 Hyper Eco Core New function: "By-pass" Ventilation External Control Setting Better energy conservation by improved total heat exchange efficiency. In addition to the automatic damper open/close function, open/close control via external devices is now possible, delivering a“By-pass” ventilation system that is suitable to the installed environment. Introducing the new Hyper Eco Element Mitsubishi's newly developed Hyper Eco Element is on board, offering the industry's best total heat exchange efficiency. Energy conservation performance has been improved not only by reducing the air conditioning load associated with ventilation, but also by facilitating humidity penetration. Outdoors EA (exhaust air) Indoors SA (supply air) Control devices (example) .Temperature sensor .Humidity sensor .Timers Exhaust air Enthalpy exchange efficiency improve *Cooling, High Fan speed, 50Hz RX4 RX5 Damper Return air Supply air Fresh air LOSSNAY core Establish the wire connection by inserting the optional remote display adaptor (PAC-SA88HA-E) in the connector CN16 (Ventilation mode selector). Element Structure "By-pass" operation Remote display adaptor (Optional) PAC-SA88HA-E Brown 1 Red 2 SW1 (outside air) SW1: By-pass ventilation operation switch (When closed: For By-pass ventilation operation) 73% RA (return air) Yellow 4 Green 5 Humidity does not penetrate easily. Humidity penetration is facilitated. The automatic damper mode automatically provides the correct ventilation for the conditions in the room. The following shows the effect “By-pass” ventilation will have under various conditions. 70% 69% 68% Improved adhesive agent material 67% 66% Dividerplates 65% Humidity Not used. Insulate completely. Max wiring length 10 m Automatic ventilation setting 71% Hyper Eco Element Adhesive agent with low humidity penetration rate Fan speed/ Ventilation mode selection 72% Hyper Element Spacerplates CN16 Orange 3 With SW1 is “ON”, the ventilation mode of LOSSNAY is changed to the By-pass ventilation regardless of the setting on the remote controller. 74% OA LOSSNAY control board New adhesive agent with high humidity penetration rate 64% 15RX Type 25RX Type 35RX Type 50RX Type 65RX Type 80RX Type 100RX 150RX 200RX Type Type Type 1. Reduces cooling load If the air outside is cooler than the air inside the building during the cooling season (such as early morning or at night), “By-pass” ventilation will draw in the cooler outside air and reduce the cooling load on the system. Extra Low Mode CO2 Sensor Additional energy conservation by using a four-level air volume system that allows more precise control. The system allows you to measure CO2 density and thereby control the amount of fresh air supplied. By connecting a CO2 sensor to the connector CN16, which is added to the LOSSNAY main unit, the setting can be switched to High, Low, or Extra Low operation, which is selected when the sensor is turned ON. This system produces additional energy conservation. In addition to the conventional Extra High, High, and Low modes, an Extra Low mode is added to provide a more dynamic range of air volume settings and versatility in a variety of installation environments, yielding much better energy conservation. Using a simplified timer function, it switches to Extra Low operation when the operation stop button is activated and it is accordingly possible to implement 24-hour energy conservation ventilation. A) Extra Low Low 2. Night purge “By-pass” ventilation can be used to release hot air from inside the building that has accumulated in buildings a business district during the hot summer season. 3. Office equipment room cooling During cold season, fresh air can be drawn in and used as is to cool rooms where the temperature has risen due to the use of office equipment. * When the outdoor air tempereture drops lower than 8ºC it changes to the heat exchange ventilation. (Display of the remote controller does not change) * In the case of “By-pass” ventilation, the supply air temperature slightly rises more than the outside air temperature because of the heat effect around the ducts or the unit motors. Fan speed High High CO2 density Fan speed Extra-Low Low CO2 density CO2Sensor CO2Sensor High Air volume can be set using a pin position. To force High fan speed externally B) Extra Low Low Extra High CO2 sensor, etc. (When CO2 increases: Closed) SW1 * The Extra High and High ventilation modes are selectable by the initial setting. * Extra-Low not equipped LGH-150RX 5 and 200RX 5. * The ventilation mode is actually selected in three levels, and the remote controller also displays these three levels. SW1: High fan speed operation switch (When closed: For High fan speed operation) 3 Remote display adaptor (Optional) PAC-SA88HA-E Brown 1 Red 2 Orange 3 Yellow 4 Green 5 LOSSNAY control board CN16 When SW1 is "ON", fan speed of the LOSSNAY will be set to "High"(Extra-High) regardless of the remote control setting. Use this in such a way that it ventilates at Low or Extra-Low fan speed normally, and when the external sensor detects contamination of indoor air, it changes to High (Extra High) fan speed operation. Fan speed/ Ventilation mode selection Not used. Insulate completely. Max wiring length 10 m 4 Multi-ventilation Mode enables the appropriate supply/ exhaust balance to be selected to suit the usage environment and location Featuring "Multi-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamically. The supply/exhaust balance can be selected to suit the usage environment and location, such as allowing for air exhausted via extractor fans. Modes can be selected easily by setting the connectors on the circuit board. Control switch Hand-held remote control for microprocessor type High Low Ventilation mode Supply airflow Exhaust airflow Unit setting * Factory setting is "High" for both supply and exhaust. Air supply Air exhaust High Power air supply/exhaust mode High High High Power air supply mode High Low High Low Power air exhaust mode Low High Low High Energy-saving ventilation mode Low Low Newly Adopted Dot Matrix Display Available in Eight Languages ARIAESTERNA VENTILATION ITALIANO ENGLISH e Air supply and exhaust are "Low" irrespective of unit setting. * "High notch" can also be further set to "Extra High" using the unit switch. Offers choice of 9 air supply/exhaust combination patterns. Geblasebetrieb Deutsch Normal office, etc. Providing efficient ventilation while maintaining air supply/exhaust balance... Power air supply /exhaust Smaller offices or tenant buildings, etc. Using LOSSNAY compensates for using extractor fans... Power air supply Smoking areas, etc. Priority on air exhaust... Power air exhaust New Remote Controller PZ-60DR-E Energy Saving by VENTILACIoN VENTILATION ESPANOL FRENCH timer Air volume level can be set hourly (max 8 times) and weekly. You can pre-set air volume according to the predictable requirement so that LOSSNAY can automatically operate at only necessary air-speed at the specified time period, which saves power consumption while maintaining the indoor air quality. Besides, once the weekly timer has been set, no switching on-off is required. Example A (Hourly) current RX4 series with PZ-41SLB controller 8:00 new RX5 series with PZ-60DR-E 8:00 9:00 low 13:00 low 17:00 high 19:00 low 22:00 extra low 1,210W (18%) less Example B (Weekly) 8:00 Saturday to Sunday 9:00 low 8:00 Friday Energy Saving by 12:00 high Tolal power consumption in one day : LGH-100RX4-E : 6,600W (14 hours)          LGH-100RX5-E : 5,390W (14 hours) Monday to Thursday A new remote controller for the RX5 series is now available. In addition to boosting the energy conservation performance of the main unit, the remote controller features a variety of new functions which also pursue additional energy conservation. The appearance of the remote controller conforms to Mitsubishi air conditioner interface design standards. Functions that were set using Dip-Switch on the LOSSNAY main unit can now be configured as needed using the new remote controller. This eliminates the need to crawl under the eaves to change operation settings. Also, a newly adopted dot matrix display provides much more information, making it easy to check maintenance indications, operation status display, and explanations required when configuring settings. 22:00 high 12:00 high 9:00 low 13:00 low 12:00 high 17:00 high 13:00 low 19:00 low 17:00 high 22:00 extra low 22:00 extra low 8:00 22:00 extra low Night Purge Function During the summer season, the Night Purge function draws cooler outside air into the room to suppress temperature rises at night. This energy conservation function reduces the load when air conditioning is started the next morning. Dot matrix display While air conditioning and ventilation are not operating, the room temperature rises as a result of heat from the skeleton and OA equipment. When the outside temperature becomes lower than the room temperature, ventilation starts automatically. At night, the outside temperature drops. Hot air is discharged. When the room becomes sufficiently cool, ventilation is stopped. ON/OFF button Fan speed Adjustment button Button CLEAR button Filter button Return button Timer MENU (MONITOR/SET) button Set time buttons Back Ahead OPERATION buttons Back Ahead Function selector button "Extra Low" fan speed button OPERATION button The air conditioning load required to reach the set temperature the next morning is reduced. Timer ON/OFF (DAY) button The out door temperture (OA) setting can be selected either 17゜ C or 28゜ C by using Dip-Switch (SW2-7) in the LOSSNAY control box. Refer to the Instillation Manual for more information. *Do not use the night purge function if fog and heavy rain is expected. The entry of rain water may occur in the night. 5 6 Control The New Remote Controller PZ-60DR-E enable simple control setting Interlocked with Air conditioners LOSSNAY independent Interlocked with City Multi Interlocked with Mr.Slim M-NET transmission line City Multi Slim-LOSSNAY connection cable LOSSNAY RX5 Mr.Slim Can Be Used With AG-150A Centralized Controller Controllers are one of the most important and familiar devices in an air conditioning system. Not only does it control to provide optimum air environment but supports operations to minimize running costs and to preserve energy. Through studies and development, we've visualized a new system controller meeting needs with versatile options. With a new coloured touch panel, new functions, and continuation of all the current G-50A functions, AG-150A visualizes its functions from basic control to advanced operations and bringing an ultimate controller to reality. LOSSNAY RX5 (Max 15 unit) – Design your control with our new centralized controller; AG -150A. System structure LOSSNAY RX5 M-NET Switching Hub LOSSNAY remote controller PZ-60DR-E can be connected PZ-52SF-E can be used insted of PZ-60DR-E, However, function is limited and connecting position is different. LOSSNAY remote controller PZ-60DR-E The LOSSNAY remote controller (PZ-60DR-E, PZ-41SLB-E) can not be used with this system. PZ-41SLB-E can be connected however function is limited. M-NET adapter LAN (100BASE-TX) M-NET A Control AG -150A Remote Monitoring PC Remote monitoring via a Web browser Power supply unit (PAC-SC51KUA) Centralized Controller System General Equipment DIDO Controller (PAC-YG66DCA) Hub Centralized controller AG-150A Temp/Humidity sensor Lights M-NET Outdoor unit Hub Interlocked with City Multi indoor units Indoor unit LOSSNAY RX5 Power supply unit (PAC-SC51KUA) Network remote controller Mr.Slim indoor unit PI Controller (PAC-YG60MCA) Network remote controller LOSSNAY remote controller PZ-60DR-E ON/OFF Operation mode switching LOSSNAY remote controller PZ-60DR-E Temperature setting Interlocked with external devices LOSSNAY RX5 LOSSNAY remote controller PZ-60DR-E Ext. signal source Modem VPN Router Internet Remote monitoring PC Mobile phone of service person Note : Use a security device such as a VPN router when connecting the AG-150A to the Internet to prevent unauthorized access. Item Controllable unit LOSSNAY units only LOSSNAY remote controller PZ-60DR-E Modem : Each unit Mr.Slim remote controller LOSSNAY RX5 Service company /Sales office Remote monitoring via a Web browser Functions LOSSNAY RX5 LOSSNAY RX5 AG-150A / GB-50A VPN Router Interlocked with Mr. Slim indoor units Mr.Slim outdoor unit Watt hour meter Central Control PC (TG-2000A) *Ver. 5.50 or later Indoor unit Ventilation AI Controller (PAC-YG63MCA) Fan speed setting Air flow direction setting Schedule operation Permit / Prohibit local operation Indoor unit intake temperature Error Test run Ventilation interlock External input/output : Each group : Each block : Each floor : Collective Description : Not available Operations Display Up to 50 units/groups. Run and stop operation for the air conditioner units and general equipment. (To operate general equipment, PAC-YG66DCA is required.) Switches between Cool / Dry / Auto / Fan / Heat. (Group of LOSSNAY unit : automatic ventilation/ vent - heat interchange/ normal ventilation) depending on the air conditioner unit. Auto mode is for City Multi R2 and WR2 series only. Cool/Dry : 19 (67 ) - 30 (87 ) [14 (57 ) - 30 (87 )] Heat : 17 (63 ) - 28 (83 ) [17 (63 ) - 28 (83 )] Auto : 19 (67 ) - 28 (83 ) [17 (63 ) - 28 (83 )] [ ] in case of using middle-temperature on PDFY, PEFY-VML/VMR/VMS/VMH-by setting DipSW7-1 to ON. Yet, PEFY-P-VMH-E-F is excluded. Models with 4 air flow speed settings: Hi/Mid-2/Mid-1/Low Models with 3 air flow speed settings: Hi/Mid/Low Models with 2 air flow speed settings: Hi/Low Fan speed setting (including Auto) varies depending on the model. Air flow direction angles, 4-angle or 5-angle Swing, Auto (Louver cannot be set) Weekly schedule can be set by groups based on daily operation pattern. Individually prohibit operation of each local remote control function (Start/Stop, Change operation mode, Set temperature, Reset filter). Measures the intake temperature of the indoor unit only when the indoor unit is operating. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. This operates air conditioner units in test run mode. The ventilation unit (LOSSNAY) is able to automatically start its operation when operation of the interlocked indoor unit starts. By using optional external input/output adaptor (PAC-YG10HA) you can set and monitor the following. Input : By level signal : "Batch start/stop", "Batch emergency stop" By pulse signal : "Batch start/stop", "Enable/disable local remote controller" Output : "Start/stop", "Error/Normal" X X *NOTE: Operation and displayed content vary depending on the indoor unit model. 7 8 List of Remote Controller Settings and Functions Controllers The remote controller provides a wide range of functions and features other than the main functions described above, such as sophisticated energy conservation control and an easy to see, easy to use interface. LOSSNAY remote controller (PZ-60DR-E) New Controller PZ-60DR-E (V Controlling) PZ-52SF-E (M-NET) 120 New Function Extra low fan speed (Except LGH-150RX5 and 200RX5) Weekly timer Simple timer Night Purge mode Multi languages display 24-hours ventilation (Except LGH-150RX5 and 200RX5) Operation function limit Clock display Contact number setting for error situation LOSSNAY core cleaning sign Air volume display by external signal By-pass display by external signal Possible setting from the controller in addition to unit Dip-SW setting Extra High / High switch setting Multi Ventilation mode Power supply / exhaust when operation starts Pulse input Inter locking mode Automatic recovery following power supply interruption Delay operation at heating or cooling start-up Operation output monitor Exhaust fan stop at outdoor air lower than -15ºC Exhaust fan stop during defrosting,exhaust fan Low speed operation at outdoor air lower than -15ºC By-pass automatic ventilation priority setting Filter cleaning sign Maintenance display Total operated hours Total LOSSNAY mode operated hours Error history Carry on function In the use of MELANS M-NET 2 controllers display "Central" indication(use prohibition) PZ-41SLB-E (V Controlling) 19 130 (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) only auto recover mode (in unit setting) (in unit setting) (in unit setting) (in unit setting) 1–15 120 8 70 48 33 70 48 Unit: mm 8 33 Unit: mm *Stock available only. *Stock available only. Source power requirement Interface condition for transmission line Number of LOSSNAY units controlled by PZ-41SLB-E Input voltage: 9VDC-15VDC, 0.02A Power received from a LOSSNAY unit, TM4 1 - 2 Specialized transmission line: DC power+AM modulation 1–15 Source power requirement Interface condition for transmission line Input voltage: 17VDC – 30VDC, 0.02A Power received from an outdoor unit or a power supply unit via M-NET transmission line. M-NET transmission line: 30VDC+AMI signal (±5VDC) Number of M-NET controlled LOSSNAY 1–16 units controlled by PZ-52SF-E Filters B B 取 付 日 High-efficiency filter This high-efficiency filter (with 65% colorimetricity EU-F7) can be incorporated inside the LOSSNAY unit without the need to attach parts from other systems, as done to date. The main unit external dimensions are unchanged, and processing capacity ranges between 150m3/h and 2,000m3/h. AIR FLOW   年  月  日 Standard filter Replacement components for the standard air filter supplied with the LOSSNAY LGH main unit. A A C C Installation with duct direction changed Avoid installations where the stale air exhaust aperture would be blocked by lighting or air conditioning units. Can be installed close to the surface of the wall. A space is necessary to prevent the influx of rainwater. OA EA Changing the duct direction Collar Aperture Plate 9 Number of LOSSNAY units controlled by PZ-41SLB-E LOSSNAY M-NET remote controller (PZ-52SF-E) LOSSNAY remote controller (PZ-41SLB-E) Ducts can be connected in two different directions to the outdoor vents thanks to collars and aperture plates that can be interchangeably placed in two different positions. This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both planning and installation that much simpler. EA Power received from a LOSSNAY unit, TM4 1 - 2 Unit: mm Connect ducts in two different directions (OA, EA side) Standard installation Source power requirement 120 Function(Communicating mode) Exchangeable OA Model Lighting, etc. EA OA Remove the collar (factory-standard direction) and the side panel aperture plate and switch their placements. They are both equipped with screw stoppers making the switch extremely simple. The direction of the ducts can only be changed on the outside (OA and EA). The inside cannot be changed (SA and RA). The position of the suspension bracket is changed to improve workability. OA/EA square duct (LGH-150・200R) By attaching the suspension bracket in the center of the product, the suspension bracket does not need to be moved even when the product is mounted upside down. (Model LGH-15 to 65) OA/EA is square duct. This simplifies installation and reduces total installation time. PZ-25RF8-E PZ-35RF8-E PZ-50RF8-E PZ-65RF8-E PZ-80RF8-E PZ-100RF8-E Number of Dimension (mm) filters per set A 333 399 470 433 451 565 B 156 183 183 218 243 243 Applicable model Filter material C Supply Exhaust 2 2 15 LGH-15RX5-E,LGH-25RX5-E 2 2 20 LGH-35RX5-E Nonwoven filter 2 2 15 LGH-50RX5-E Collection efficiency 2 2 15 LGH-65RX5-E (EU-G3) 2 2 15 LGH-80RX5-E,LGH-150RX5-E(2sets) 2 2 15 LGH-100RX5-E,LGH-200RX5-E(2sets) Dimension (mm) Number of Filter filters Applicable model material per set A B 2 144 327 LGH-15RX5-E,LGH-25RX5-E PZ-25RFM Non combustible 2 171 393 LGH-35RX5-E PZ-35RFM fiber 2 171 464 PZ-50RFM LGH-50RX5-E (Polyester 2 205 427 PZ-65RFM LGH-65RX5-E polyolefin) 2 232 446 PZ-80RFM LGH-80RX5-E,LGH-150RX5-E(2sets) (EU-F7) 2 232 559 PZ-100RFM LGH-100RX5-E,LGH-200RX5-E(2sets) Model Incorporation into the main unit is simple, and filter changes can be performed via the main unit inspection opening. 10 A Breath of Freshness in Restaurants, Offices, and Schools Restaurants Offices Schools A restaurant can never be too clean and its air never too fresh Fresh air–improving the overall quality of working life Creating the best possible environment for our children to succeed The atmosphere of a restaurant is crucial to securing customers and making them happy enough to come back for more. Cleanliness is the key to an attractive atmosphere and restaurants devote significant effort to ensuring the premises are sanitary. Sanitation and cleanliness, however, are not enough. No matter how clean a restaurant may look, if there are bothersome odors lingering in the air, all those efforts go to waste and the restaurant's clean image is tarnished. For these reasons, we invite restaurant owners to leave the air to LOSSNAY. LOSSNAY's superior ventilation capabilities ensure that every breath is a breath of freshness keeping guests happy. LOSSNAY also keeps owners happy with its remarkable heat recovery technology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy and expense. Many office buildings today are heavily insulated air-tight structures with little or no natural ventilation. The unnatural environment created by air conditioners without added ventilation is a breeding ground for bacteria. Factor this in with the accumulation of pollutants and odors in the form of cigarette smoke, formaldehyde, pollen, dust, and carbon dioxide, and the necessity of ventilation becomes ever more apparent. In fact, poorly ventilated buildings can give rise to Sick Building Syndrome, a malady that is known to cause headaches, sore eyes, itching, and concentration loss. This results not only in discomfort at best and sickness at worst for the building's occupants, but also the reduced productivity of the workforce. Fresh air, effectively ventilated throughout the building, is therefore essential to the overall quality of working life. Children deserve all the help we can give for them to grow up healthy, happy, and prosperous. No matter how good a school's curriculum, no matter how positive and enthusiastic the teacher, a child who does not feel well will have a hard time learning. The constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where large numbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate, decreasing the levels of oxygen that are vital for alertness and concentration. This is especially true during the winter months when windows tend to remain closed. LOSSNAY ventilates fresh outdoor air into classrooms to replenish the supply of oxygen and expels not only carbon dioxide, but also other pollutants and odors that inevitably sully the air. If it’s LOSSNAY... If it’s LOSSNAY... If it’s LOSSNAY... Ventilators work to exhaust stale air and supply fresh, clean air free of the odors associated with cooking, cigarettes, and the people working and dining. Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building, effectively ventilating even fully airtight structures. The continuous influx of fresh, outdoor air and the exhaust of stale, indoor air ensure that the indoor oxygen level is maintained at just the right balance for comfort and health. Change in room temperature is kept to a minimum during ventilation thanks to the heat-recovery function. Multiple split-type units operate independently of one another, simplifying system set up and ensuring a layout that optimally matches nearly any office design. Occupants have the luxury of breathing fresh air at all times even in highly air-tight buildings. The ventilators operate very quietly so those in the midst of enjoying their meals will not be bothered by any excess noise. LOSSNAY operation can be interlocked with air-conditioning system operation. LOSSNAY's sound attenuation qualities prevent outside noise from penetrating into the room, helping to maintain a quiet environment for productive study. A large array of ventilators is available to match the layout of just about any restaurant. Heat that is commonly lost due to ventilation is collected and reused thanks to the LOSSNAY Core, reducing air conditioners’ energy load and cutting operating costs. Heat-exchange technology prevents fluctuations in temperature for significant energy savings when either heating or cooling a room. What would you most like to see improved in restaurants? O2 concentration and deficiency 52.3% Improvement in overall cleanliness Others: No response 21% Promotion of waste prevention: 5.4% Improvement in employees’ attitude toward customer service: 20.5% O2 Concentration (%) Reduction of time required for food to reach the table: 12.0% 18% 21 Improvement in atmosphere: 6.5% 16% Normal air 15 10 5 0 Safety minimum Increased respiration and pulse 12% 10% 8% Dizziness, nausea,loss of Paleness of Comatose muscle strength skin, vomiting. Unconsciousness (death in 8min) (precursors to death) 6% Convulsions respiration stops, death 1996 Foodstuffs Consumption Monitor, Second Periodic Survey (Ministry of Agriculture, Forestry and Fisheries, Japan) 11 12 Specifications / Dimensions LGH-15 to 100RX5 LGH-15RX5-E LGH-15RX5-E Model Frequency / Power source 50Hz / Single phase 220-240V LOSSNAY ventilation By-pass ventilation Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.44-0.46 0.37-0.38 0.25-0.25 0.14-0.15 0.45-0.46 0.37-0.38 0.25-0.26 0.14-0.15 96-110 80-90 53-59 30-35 97-110 81-91 54-61 30-35 (m3/h) 150 150 110 70 150 150 110 70 (L/s) 42 42 31 19 42 42 31 19 (mmH2O) 10.2-10.7 6.6-7.1 3.6-4.1 1.4 10.2-10.7 6.6-7.1 3.6-4.1 1.4 (Pa) 100-105 65-70 35-40 14 100-105 65-70 35-40 14 82.0 82.0 84.0 85.5 Heating 75.0 75.0 77.5 81.0 Cooling 73.0 73.0 76.5 81.0 27.5-28 26.5-27 22-23.5 18 28.5-29 27-28 23-24 18-19 Power consumption (W) Air volume External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) (Measured at 1.5m under the center of panel in an anechoeic chamber) Noise (dB) Weight (kg) 20 Under 0.8A Less Starting current *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 6dB greater than the indicated value.(at High Fan speed) 50Hz/Single phase 220V Enth Ent 80 30 300 60 25 250 50 20 200 15 150 hal py exch ange effic ienc exc y(H han eatin ge g) eff icie nc y(C oo ling ) 10 20m Extra high 100 Extra low 15m 10m High 5m 5 0 50 0 50 100 150 200 70 30 300 60 25 250 Temp efficieerature exc Enth hange ncy alpy exch Ent ange hal e py fficie exc ncy han (He ge atin g) eff icie nc y(C oo ling ) 50 20 200 Extra high 15 150 80 100mm dia pipe length Low Pa External static pressure mmH 2 O LGH-150 and 200RX5 70 alpy 50Hz/Single phase 240V Exchange efficiency (%) 90 Temp e efficie rature exch ncy ange 250 10 20 30 20m 10m 100 High Extra low 5m 5 0 50 0 50 100 (m2/h) 0 100mm dia pipe length 15m Low 10 Pa Exchange efficiency (%) External static pressure mmH 2 O 90 150 200 250 (m2/h) 40 50 60 70 0 10 20 Air volume (L/s) 30 40 50 60 70 Air volume (L/s) Position where duct direction change is possible 102 768 Air exhaust fan By-pass damper plate Ceiling suspension fixture (4-13x20 oval) 65 RA (return air) 782 20 150 ~250 Core, air filter, HighEfficiency filter, fan, Maintenance space More than 600 OA (outside air intake) 102 Inspection opening LOSSNAY core Position where duct direction change is possible 13 780 Control box 30 273 Maintenance cover High efficiency filter(sold separately) attachment position 103 97.5 110 30 103 SA (supply air) Power supply cable opening 65 Air supply fan 95 735 530 EA (exhaust air outlet) Air filters(EU-G3) Unit: mm 14 LGH-25RX5-E LGH-35RX5-E LGH-25RX5-E Model Frequency / Power source LGH-35RX5-E Model 50Hz / Single phase 220-240V Frequency / Power source LOSSNAY ventilation By-pass ventilation 50Hz / Single phase 220-240V Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 0.52-0.55 0.47-0.48 0.26-0.27 0.17-0.18 0.53-0.55 0.47-0.48 0.26-0.27 0.17-0.18 Current (A) 0.92-0.92 0.74-0.74 0.5-0.51 0.28-0.3 0.93-0.94 0.77-0.77 0.51-0.52 0.28-0.3 Power consumption (W) 113-129 102-114 56-62 36-42 115-131 103-115 56-63 36-42 Power consumption (W) 195-212 160-169 105-116 58-69 197-217 164-173 105-116 58-69 (m3/h) 250 250 155 105 250 250 155 105 (m3/h) 350 350 210 115 350 350 210 115 (L/s) 69 69 43 29 69 69 43 29 (L/s) 97 97 58 32 97 97 58 32 (mmH2O) 8.2-8.7 5.1-6.1 2-2.5 0.9 8.2-8.7 5.1-6.1 2-2.5 0.9 (mmH2O) 15.8-16.3 7.6-8.2 2.5-3.1 0.9 15.8-16.3 7.6-8.2 2.5-3.1 0.9 (Pa) 80-85 50-60 20-25 9 80-85 50-60 20-25 9 (Pa) 155-160 75-80 25-30 9 155-160 75-80 25-30 9 79.0 79.0 81.5 83.5 80.0 80.0 85.0 88.0 Heating 69.5 69.5 74.0 77.5 Heating 71.5 71.5 76.5 81.5 Cooling 68.0 68.0 72.5 76.0 Cooling 71.0 71.0 75.5 81.0 26-27 25-26 20-21.5 18-19 32-32 28.5-29.5 21.5-23 18 32.5-32.5 29.5-30.5 21.5-24 18 Enthalpy exchange efficiency (%) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) 26.5-27.5 25.5-26.5 20.5-22 18-19 20 Under 0.9A Less Starting current Weight (kg) 50Hz/Single phase 220V Exchange efficiency 80 70 60 200 60 50 150 dia pipe length 40m 150 Low 100 5 50 0 0 Exchange efficiency (%) 80 Enth alpy Enth alpy e 70 exch a xcha nge 350 nge effic ienc effic ie y(He ncy( 60 Coo 300 30 30m High Extra low 20m 10m 50 100 150 200 250 300 350 400 25 250 20 200 150 dia pipe length Extra high 40m 150 15 30m Low High 10 100 5 50 0 0 Extra low 10m 50 100 150 (m2/h) 0 20m 200 250 300 350 400 (m2/h) 10 20 30 40 50 60 70 80 90 100 0 25 250 20 200 10 50 Low 0 0 50 100 150 200 250 300 350 400 450 500 0 Air volume (L/s) 20 40 60 80 100 120 LOSSNAY core 780 150mm dia pipe length 30m High Extra low 150 20m Low 100 10m 5 50 0 0 50 100 150 200 250 300 350 400 450 500 20 40 Core, air filter, HighEfficiency filter, fan, Maintenance space 60 80 100 120 140 Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture 875 80 (4-13x20 oval) 124 921 874 650 30 273 g) RA (return air) 124 Inspection opening LOSSNAY core 64 142 160 SA (supply air) Power supply cable opening Air supply fan Control box 80 55 315 Maintenance cover 888 High efficiency filter(sold separately) attachment position 64 55 30 63 Control box OA (outside air intake) Maintenance cover High efficiency filter(sold separately) attachment position 63 eatin Air volume (L/s) 20 20 Inspection opening ncy( H ienc y( 142 160 150 ~250 102 SA (supply air) Power supply cable opening 65 Air supply fan 95 782 735 530 Core, air filter, HighEfficiency filter, fan, Maintenance space More than 600 OA (outside air intake) 200 EA (exhaust air outlet) RA (return air) EA (exhaust air outlet) 20 0 Ceiling suspension fixture (4-13x20 oval) 65 150~250 768 250 140 Air exhaust fan More than 600 102 effic ie effic Coo ling) Air volume (L/s) By-pass damper plate ange ange (m2/h) Position where duct direction change is possible Air exhaust fan 25 10 10m 50 exch exch 300 30 15 20m Extra low Temp efficieerature e xcha ncy nge Extra high High 100 5 350 30m 150 15 60 alpy Enth alpy 70 150mm dia pipe length Enth (m2/h) 10 20 30 40 50 60 70 80 90 100 Air volume (L/s) 50 Exchange efficiency (%) 80 ating ) ling) 50Hz/Single phase 240V 90 Temp e efficie rature ex chan ncy ge Extra high Extra high 15 10 70 50Hz/Single phase 220V 90 Tem effic perature ienc Enth y exchang alpy e exch ange Ent halp effic ienc y ex y(H cha eatin nge g) effic ienc y(Co oling ) Pa 20 50Hz/Single phase 240V Exchange efficiency Pa 250 *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 10dB greater than the indicated value.(at High Fan speed) 80 External static pressure mmH 2 O 25 Pa External static pressure mmH 2 O 50 90 Tem effic perature ienc En th y exchang alpy e exch ang Ent e halp effic y ex ienc y(H cha eatin nge g) effic ienc y( Co oling ) 29 Under 2.4A Less Starting current *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 10dB greater than the indicated value.(at High Fan speed) 90 (Measured at 1.5m under the center of panel in an anechoeic chamber) Noise (dB) External static pressure mmH 2 O Noise (dB) External static pressure 95 Temperature exchange efficiency (%) Pa External static pressure Air volume By-pass ventilation External static pressure mmH 2 O Air volume LOSSNAY ventilation Position where duct direction change is possible 15 Air filters (EU-G3) Unit: mm Position where duct direction change is possible Air filters(EU-G3) Unit: mm 16 LGH-50RX5-E LGH-65RX5-E LGH-50RX5-E Frequency / Power source LOSSNAY ventilation By-pass ventilation Extra High High Low Extra Low Extra High High Low Extra Low Current (A) 1.2-1.25 1.0-1.0 0.85-0.85 0.4-0.4 1.25-1.25 1.0-1.0 0.85-0.85 0.4-0.4 Power consumption (W) 255-286 207-228 175-190 80-95 260-290 210-230 180-195 80-95 (m3/h) 500 500 390 180 500 500 390 180 (L/s) 139 139 108 50 139 139 108 50 (mmH2O) 15.3-15.8 6.6-9.2 4.1-6.1 1.0 15.3-15.8 6.6-9.2 4.1-6.1 1.0 (Pa) 150-155 65-90 40-60 10 150-155 65-90 40-60 10 78.0 78.0 81.0 86.0 Heating 69.0 69.0 71.0 78.0 Cooling 66.5 66.5 68.0 77.0 33-34 30.5-32 26.5-28 19 (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) 50Hz/Single phase 220V 34-35 31-32.5 27-29 19 350 60 30 300 25 250 20 200 15 150 10 50m High 40m Low 100 30m Extra low 5 20m 50 10m 0 0 100 200 300 400 500 600 70 35 350 60 30 300 50 60m Pa External static pressure mmH 2 O 50 200mm dia pipe length 700 25 250 20 200 15 150 10 40 60 excha nge efficie ncy ye xchan ge eff icienc Enth y (H alpy eatin exch g) ange efficie ncy (Coo ling) Extra high 60m 50m 30m Extra low 5 50 0 0 0 20m 10m 100 200 20 40 60 300 400 (m2/h) 500 600 700 80 100 120 140 160 180 200 350-380 308-322 248-265 120-140 350-385 310-335 250-265 120-140 (m3/h) 650 650 520 265 650 650 520 265 (L/s) 181 181 144 74 181 181 144 74 (mmH2O) 11.2-12.2 6.1-8.2 4.1-5.1 0.8 11.2-12.2 6.1-8.2 4.1-5.1 0.8 (Pa) 110-120 60-80 40-50 8 110-120 60-80 40-50 8 77.0 77.0 80.0 86.0 Heating 68.5 68.5 70.5 78.0 Cooling 66.0 66.0 68.5 77.0 34-34.5 32-33 28.5-31.5 22 34.5-35 32.5-33.5 28.5-30.5 22-22.5 Air volume External static pressure Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) 50Hz/Single phase 220V efficiency (%) rature exchan geefficie ncy lpy ex change Enth efficienc alpy y excha (Heati nge effic ng) iency (C ooling) 124 Inspection opening 450 60 40 400 50 35 350 30 300 25 250 20 200 15 150 Extra high 10 100 5 50 0 200mm dia pipe length 40m Low High 30m Extra low 20m 10m 0 rature exchan ge effic iency lpy ex change Enth efficienc alpy y excha (Heati nge effic ng) iency (C ooling) 450 60 40 400 50 35 350 30 300 25 250 20 200 15 150 0 25 50 Extra high 10 100 5 50 30m High Extra low 20m 10m 100 200 300 400 500 600 700 800 900 25 Position where duct direction change is possible By-pass damper plate 895 Ceiling suspension fixture (4-13x20 oval) 70 RA (return air) 954 692 Core, air filter, HighEfficiency filter, fan, Maintenance space 75 100 125 150 175 200 225 250 50 Air volume (L/s) SA (supply air) OA (outside air intake) High efficiency filter(sold separately) attachment position 79 40m Low 0 EA (exhaust air outlet) 30 60m 50m 0 75 100 125 150 175 200 225 250 Air exhaust fan 315 200mm dia pipe length (m2/h) Power supply cable opening 133 Inspection opening 70 386 High efficiency filter(sold separately) attachment position LOSSNAY core 79 Air supply fan Control box Maintenance cover Maintenance cover 888 Tempe Entha 0 100 200 300 400 500 600 700 800 900 133 95 SA (supply air) Power supply cable opening 65 Air supply fan Control box efficiency (%) 70 45 50m 908 79 30 192 208 LOSSNAY core 79 80 Entha 70 45 50Hz/Single phase 240V 90 Exchange Tempe 1063 20 OA (outside air intake) Extra Low 40 Under 4.4A Less Air volume (L/s) Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture 875 65 1016 745 0.6-0.6 Power consumption (W) (m /h) RA (return air) More than 600 150~250 1.2-1.2 2 Air volume (L/s) EA (exhaust air outlet) Core, air filter, HighEfficiency filter, fan, Maintenance space 40m High Low 100 80 100 120 140 160 180 200 124 1.5-1.5 80 200mm dia pipe length Air volume (L/s) Air exhaust fan 1.7-1.8 rature Ent halp (m /h) 20 0.6-0.6 90 Exchange Tempe 2 0 1.2-1.2 192 208 35 50Hz/Single phase 240V External static pressure mmH 2 O 70 excha Ent nge halp efficie ncy ye xchan ge e fficien Enth cy (H alpy eatin exch g) ange efficie ncy (Coo ling) Extra high 1.5-1.5 Starting current Exchange efficiency (%) 400 80 rature 1.7-1.8 *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 10dB greater than the indicated value.(at High Fan speed) 90 Tempe Low Current (A) Weight (kg) Pa Exchange efficiency (%) 400 80 High Enthalpy exchange efficiency (%) *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 16dB greater than the indicated value.(at High Fan speed) 90 Extra High Temperature exchange efficiency (%) 32 Under 3.0A Less Starting current Extra Low 95 Noise (dB) Low Pa Enthalpy exchange efficiency (%) High External static pressure mmH2O Temperature exchange efficiency (%) By-pass ventilation Extra High 1001 External static pressure LOSSNAY ventilation Ventilation mode Fan speed 20 Air volume 50Hz / Single phase 220-240V More than 600 150~250 Ventilation mode Fan speed LGH-65RX5-E Model 50Hz / Single phase 220-240V Pa Frequency / Power source External static pressure mmH2O Model Position where duct direction change is possible 17 Air filters(EU-G3) Unit: mm Position where duct direction change is possible Air filters(EU-G3) Unit: mm 18 LGH-80RX5-E LGH-100RX5-E LGH-80RX5-E Frequency / Power source LOSSNAY ventilation By-pass ventilation Ventilation mode Fan speed Extra High High Low Extra Low Extra High High Low Extra Low Ventilation mode Fan speed Current (A) 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65 1.75-1.75 1.6-1.6 1.45-1.45 0.60-0.65 Power consumption (W) 380-415 345-370 315-340 125-145 380-415 345-370 315-340 120-145 (m3/h) 800 800 700 355 800 800 700 355 (L/s) 222 222 194 99 222 222 194 99 (mmH2O) 14.8-15.3 10.7-12.2 8.2-9.7 2 14.8-15.3 10.7-12.2 8.2-9.7 2 (Pa) 145-150 105-120 80-95 20 145-150 105-120 80-95 20 79.0 79.0 80.5 87.5 Heating 71.0 71.0 72.5 79.5 Cooling 70.0 70.0 71.5 79.5 33.5-34.5 32-33 30-31 22 Weight (kg) 50Hz/Single phase 220V 34.5-35.5 33-34 nge exch ange effic Enth ienc effic alpy e y (H ienc xcha eatin y(C nge g) ooli ng) 50 Extra high 400 40 60 250mm dia pipe length 300 30 200 20 31-32 22 60m 100 40m 20m 0 0 200 400 600 800 1000 1200 (m2/h) 0 50 100 150 200 250 300 nge exch ange effic Enth ienc y(H effic alpy exc eatin ienc hang y(C g) ooli e ng) y 80m 60m 100 40m 20m 0 200 400 600 800 1000 1200 (m2/h) 350 0 50 100 150 200 250 300 350 Air volume (L/s) Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture (4-15x20 oval) 165 365-395 175-200 (m3/h) 1000 1000 755 415 1000 1000 755 415 (L/s) 278 278 210 115 278 278 210 115 (mmH2O) 16.3-17.3 10.2-11.2 5.6-6.1 1.8 16.3-17.3 10.2-11.2 5.6-6.1 1.8 (Pa) 160-170 100-110 55-60 18 160-170 100-110 55-60 18 80.0 80.0 83.0 87.0 Heating 72.5 72.5 74.0 80.0 Cooling 71.0 71.0 73.0 79.0 36-37 34-35 31-32.5 21-22 37-38 35-36 32-33 21-22 Air volume External static pressure Noise (dB) (Measured at 1.5m under the center of panel in an anechoeic chamber) 165 Inspection opening 50Hz/Single phase 220V Exchange efficiency (%) Ent halp En y ex tha lpy cha n exc 50 ge 500 50 40 400 30 300 ge ge efficie effic ncy(H eatin ienc Position where duct direction change is possible Exchange efficiency (%) y(C Ent 80 En halp y tha lpy exc han exc ge ge han 500 50 Tem effic peratur e ex ienc cha y n ge g) 70 efficie ng) 250mm dia pipe length 100m Extra high 60 50 40 400 30 300 20 200 ncy(H effic ienc eatin y(C ooli g) ooli ng) 250mm dia pipe length 100m Extra high 80m 80m 200 20 60m High Low 10 40m Extra low 100 20m 0 0 200 0 50 400 100 600 150 800 200 1000 250 1200 300 350 1400 High 60m Low 10 40m Extra low 100 20m 0 0 200 0 400 50 400 100 600 150 800 200 1000 250 300 1200 1400 350 400 Air volume (L/s) Air volume (L/s) Position where duct direction change is possible By-pass damper plate Ceiling suspension fixture 1010 (4-15x20 oval) RA (return air) 1231 917 95 389 399 Core, air filter, HighEfficiency filter, fan, Maintenance space High efficiency filter(sold separately) attachment position 79 SA (supply air) Power supply cable opening 165 Inspection opening 79 Air filters(EU-G3) Unit: mm Position where duct direction change is possible Air supply fan Control box 399 Maintenance cover LOSSNAY core 242 258 1144 50Hz/Single phase 240V 90 Tem effic peratur e ex ienc cha y n OA (outside air intake) Maintenance cover LOSSNAY core 79 Air supply fan Control box Extra Low 59 Under 4.6A Less 1036 1004 690 460-485 EA (exhaust air outlet) SA (supply air) Power supply cable opening OA (outside air intake) More than 600 150~250 510-550 Air exhaust fan RA (return air) EA (exhaust air outlet) 175-200 165 1010 Air exhaust fan 350-380 100m 200 0 445-475 han Extra low 10 500-535 70 250mm dia pipe length Low 20 0.9-0.9 Power consumption (W) 60 300 30 1.7-1.7 80 Extra high Air volume (L/s) Core, air filter, HighEfficiency filter, fan, Maintenance space alp Tem effic peratu ienc re e xch y a High 80m Extra low 10 50 100m Low Pa External static pressure mmH 2 O High 2.1-2.1 90 400 40 2.3-2.4 50Hz/Single phase 240V 500 50 0.9-0.9 Starting current En th 70 1.7-1.7 *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 17dB greater than the indicated value.(at High Fan speed) 80 External static pressure mmH 2 O 60 500 50 2.1-2.1 Weight (kg) Exchange efficiency (%) Pa En tha lpy 80 70 90 Tem effic perat ienc ure e xch y a 2.3-2.4 Enthalpy exchange efficiency (%) 53 Under 3.8A Less Exchange efficiency (%) Low Current (A) Temperature exchange efficiency (%) Starting current *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 16dB greater than the indicated value.(at High Fan speed) 90 High 95 (Measured at 1.5m under the center of panel in an anechoeic chamber) Extra High Pa Noise (dB) Extra Low 1144 High efficiency filter(sold separately) attachment position 79 Air filters(EU-G3) 242 258 Enthalpy exchange efficiency (%) By-pass ventilation Low External static pressure m mH 2 O Temperature exchange efficiency (%) LOSSNAY ventilation High Pa External static pressure 50Hz / Single phase 220-240V Extra High External static pressure mmH 2 O Air volume 19 LGH-100RX5-E Model 50Hz / Single phase 220-240V More than 600 150~250 Frequency / Power source 1263 Model Unit: mm 20 LGH-150RX5-E LGH-200RX5-E LGH-150RX5-E Low Extra High High Low 3.5-3.5 3.2-3.2 2.9-2.9 3.5-3.5 3.2-3.2 2.9-2.9 Current (A) Power consumption (W) 760-830 690-740 630-680 765-835 695-745 635-685 1500 1500 1300 1500 1500 1300 (L/s) 417 417 361 417 417 361 (mmH2O) 16.3-17.8 13.3-13.8 9.7-10.2 16.3-17.8 13.3-13.8 9.7-10.2 (Pa) 160-175 130-135 95-100 160-175 130-135 95-100 80.0 80.0 81.0 Heating 72.0 72.0 72.5 Cooling 70.5 70.5 71.5 38-39 36-37.5 33.5-35 External static pressure Temperature exchange efficiency (%) Enthalpy exchange efficiency (%) (Measured at 1.5m under the center of panel in an anechoeic chamber) Weight (kg) Enthalpy exchange efficiency (%) 39-40.5 37.5-39 35.5-37 E nth Enth alp External static pressure (mmH 2 O) 50 400 40 300 20 200 70 60 50 Low High 0 0 500 0 100 1000 1500 2000 (m2/h) 200 300 Enth Enth a e ef y ex ficie ch a ncy nge (He effic atin ienc g) y(C ooli ng) 100 50Hz/Single phase 240V ang Extra high 30 10 exch 400 500 600 Low 4.2-4.2 3.4-3.4 4.8-4.8 4.2-4.2 3.4-3.4 1035-1100 910-980 715-785 1040-1110 915-980 720-785 2000 2000 1580 2000 2000 1580 (L/s) 556 556 439 556 556 439 (mmH2O) 16.3-16.8 10.2-10.7 6.1-6.6 16.3-16.8 10.2-10.7 6.1-6.6 (Pa) 160-165 100-105 60-65 160-165 100-105 60-65 80.0 80.0 83.0 Heating 72.5 72.5 73.5 Cooling 71.0 71.0 72.0 39.5-40 37-38 32.5-34 40.5-41 38-39 33.5-35 alpy lpy e exch xcha ang nge 400 40 90 300 20 200 enc y(H effic eat ing ienc ) y(C ooli ng) 100 High 0 700 100 1000 1500 2000 (m2/h) 200 300 400 2500 exch ange chan ge e fficie nc efficie exch ange ncy(H 20 10 y eating ) High Low 100 0 1000 1500 2000 600 700 0 100 200 300 400 500 600 10 High 200 Low 100 0 500 0 700 1010 Core, air filter, HighEfficiency filter, fan, Maintenance space Power supply cable opening 270 Inspection opening Air supply fan 21 200 300 400 500 600 700 399 798 Control box 242 258 44 Power supply cable opening High efficiency filter(sold separately) attachment position LOSSNAY core 1144 79 Unit: mm Air filters(EU-G3) 242 258 242 258 700 700 Air filters(EU-G3) 100 242 258 High efficiency filter(sold separately) attachment position 79 2500 917 1272 27 SA (supply air) Maintenance cover 1144 2000 Ceiling suspension fixture (4-15x30 oval) 270 150~250 Maintenance cover 44 1500 RA (return air) 1231 917 110 OA (outside air intake) 399 798 Control box LOSSNAY core 1000 Air volume (L/s) EA (exhaust air outlet) 690 1045 27 Air supply fan 20 300 0 Air exhaust fan SA (supply air) Inspection opening ooling ) (m2/h) More than 600 270 150~250 More than 600 Core, air filter, HighEfficiency filter, fan, Maintenance space efficie ncy(C By-pass damper plate Ceiling suspension fixture (4-15x30 oval) 270 OA (outside air intake) 30 Air volume (L/s) RA (return air) 1004 690 EA (exhaust air outlet) 1010 ncy cy(He ating) Extra high 2500 By-pass damper plate Air exhaust fan ange (m /h) 500 fficie e eff icien exch 2 Air volume (L/s) ge e 400 40 50 chan hang 50 300 500 alpy 500 70 efficie re ex y exc Enth Extra high 0 eratu Enth alp 60 200 Tem p 80 400 30 50Hz/Single phase 240V Exchange efficiency (%) ncy(C ooling ) 40 Low Air volume (L/s) alpy 500 50 50 500 pera ture ex alpy 70 90 Tem Enth 60 0 50Hz/Single phase 220V Exchange efficiency (%) Enth e ef fici 0 2500 118 Under 11.9A Less 80 Extra high 30 10 Temp effic erature e ienc xcha y nge 500 50 (Measured at 1.5m under the center of panel in an anechoeic chamber) Starting current 80 External static pressure (mmH 2 O) 60 500 50 (Pa) 70 alpy High 4.8-4.8 *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 20dB greater than the indicated value.(at High Fan speed) Exchange efficiency (%) (Pa) 80 90 Temp effic erature e ienc xcha y nge Noise (dB) External static pressure (mmH 2 O) 50Hz/Single phase 220V Exchange efficiency (%) Extra High Weight (kg) *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 19dB greater than the indicated value.(at High Fan speed) 90 Low Temperature exchange efficiency (%) 105 Under 7.3A Less Starting current High (m3/h) Air volume External static pressure By-pass ventilation Extra High 110 Air volume LOSSNAY ventilation Ventilation mode Fan speed High (m3/h) 50Hz / Single phase 220-240V (Pa) Power consumption (W) By-pass ventilation Extra High Current (A) Noise (dB) Frequency / Power source LOSSNAY ventilation Ventilation mode Fan speed LGH-200RX5-E Model 50Hz / Single phase 220-240V External static pressure (mmH 2 O) Frequency / Power source (Pa) Model Unit: mm 22 Wiring Diagrams LGH-15RX5 to 100RX5 LGH-150RX5 and 200RX5 GREEN/YELLOW BROWN RED BLACK GREY YELLOW M2 TM1 L TAB5 TAB3 BLUE TAB1 CN10 TAB2 BROWN C SUPPLY FAN MOTOR N POWER SUPPLY 220-240V 50Hz Isolator BROWN RED N (*2) SUPPLY FAN MOTOR BLUE ORANGE BLUE WHITE M1 RED CN7 YELLOW (*2) C x103 x102 (*2) TAB5 TAB3 BLACK x103 GREY YELLOW x102 RED ORANGE BLUE WHITE RED M1 GM EXHAUST FAN MOTOR TAB1 CN10 TAB2 LS PE BLUE BROWN x101 BLUE TR1 CN1 x203 ORANGE BLUE x202 WHITE x203 C (*2) x202 RED RED CN9 CN7 x201 WHITE RED WHITE BROWN CN32 TH1(OA) ORANGE ORANGE ORANGE ORANGE CN16 SW2 SW1 CN5 SW5 BROWN CN6 ORANGE ORANGE TM4 SA1 SA2 TH2(RA) CN2 X10 9 X12 X11 TM3 6 7 8 PZ60DR-E 2 TM2 1 1 TB5 2 3 A B S 12V or 24V DC By-pass or Delay2 M-NET monitor output 6 , 7 transmission Mr.Slim Malfunction monitor (non-polar) MELANS cable output 7 , 8 MAX 240VAC 1A External control input 24VDC 1A 1 3 MIN 220VAC 100mA 5VDC 100mA *When the optional Remote Controller PZ-60DR-E is used as the M-NET System ,connect it to 1 2 of TM4 terminal block,and connect M-NET transmission wire to A , B on TB5 terminal block. (*1) TM4 Optional Remote controller 2 (PZ-60DR-E) 1 2nd remote controller (Max.2 remote controllers TB5(M-NET) installable) Unchanged a-conntact *Attention (*1) M-NET transmission cable A B EXHAUST FAN MOTOR S Sheild Wire (*1)PZ-41SLB-E and PZ-52SF-E cannot be used when using PZ-60DR-E With this product, the wiring installation method will 2nd or later main units vary according to the design of the system. Perform electrical installation to meet local electrical regulations. .Always use double insulated PVC cable for the transmission cables. .Wiring work must be performed by qualified professionals. .All supply circuits must be disconnected before obtaining access to the terminal devices. HI LO M BY-PASS C CN16 (Unchanged a-conntact) BROWN HI LO EXTRA-LO BY-PASS RED ORANGE YELLOW GREEN (*2) C (*2) x201 RED ORANGE YELLOW GREEN BLACK TR2 TR3 BLACK LS GM MG BLACK BROWN CN32 TH1(OA) ORANGE ORANGE ORANGE ORANGE CN16 SW2 SW1 CN2 BROWN CN5 SW5 TM4 10 SA1 SA2 X10 9 X12 X11 2 TM3 8 MIN 220VAC 100mA 5VDC 100mA 2 3 A 12V or 24V DC Mr.Slim (non-polar) By-pass or Delay2 monitor output 6 , 7 Malfunction monitor output 7 , 8 MAX 240VAC 1A 24VDC 1A 1 1 TB5 TM2 7 LS BLACK TH2(RA) 6 CN16 (Unchanged a-conntact) BROWN (*2) LGH-100RX5 has 2 capacitors per mortor as following drawing. C C RED ORANGE BLUE WHITE M1 2nd remote controller  (Max.2remote controllers installable cable) 2nd LOSSNAY unit (Up to max 15 units) Transmission cable (non-polar) Sheild Wire NOTE 1.TM1, TM2, TM3, TM4, TB5 shown in dotted lines are field work. 2.Isolator should be provided by the customer. 3.Be sure to connect the grounding wire. M2 SUPPLY FAN MOTOR Operation or Delay1 monitor output MAX 240VAC 2A MIN 220VAC 100mA 5VDC 100mA 24VDC 2A 10 BROWN BLACK GREY YELLOW L N N x101 TR CN9 C EXHAUST FAN MOTOR BROWN BLACK GREY YELLOW PE Isolator TM1 L L M2 CN1 POWER SUPPLY 220-240V 50Hz GREEN/YELLOW B S Sheild Wire M-NET transmission MELANS cable GM MG Operation or Delay1 monitor output MAX 240VAC 2A MIN 220VAC 100mA 24VDC 2A 5VDC 100mA (*1) PZ60DR-E 2nd remote controller  (Max.2remote controllers installable cable) 2nd LOSSNAY unit (Up to max 15 units) Transmission cable (non-polar) External control input 1 3 Unchanged a-conntact NOTE 1.TM1, TM2, TM3, TM4, TB5 shown in dotted lines are field work. 2.Isolator should be provided by the customer. 3.Be sure to connect the grounding wire. *Attention *When the optional Remote Controller PZ-60DR-E is used as the M-NET System ,connect it to 1 2 of TM4 terminal block,and connect M-NET transmission wire to A , B on TB5 terminal block. (*1) TM4 Optional Remote controller 2 (PZ-60DR-E) 1 2nd remote controller (Max.2 remote controllers TB5(M-NET) installable) A B S (*2) LGH-200RX5 has 2 capacitors per mortor as following drawing. M C C M-NET With this product, the wiring installation method will transmission Sheild Wire (*1)PZ-41SLB-E and PZ-52SF-E cannot cable vary according to the design of the system. be used when using PZ-60DR-E Perform electrical installation to meet local electrical regulations. 2nd or later main units .Always use double insulated PVC cable for the transmission cables. .Wiring work must be performed by qualified professionals. .All supply circuits must be disconnected before obtaining access to the terminal devices. *Specifications may be subject to change without notice. Definition of Symbols *Specifications may be subject to change without notice. Definition of Symbols M1: M2: C: GM: LS: TH1: TH2: SW1: SW2, 5: TM1: TM2: TM3: TM4 : TB5 : TAB1,TAB2: TR1: X10,X11,X12: 23 Motor for exhaust fan Motor for supply fan Capacitor Motor for By-pass operation Microswitch Thermistor for outside air Thermistor for return air Switch (Main/Sub change) Switch (Function selection) Terminal block (Power supply) Terminal block (External control input) Terminal block (Monitor output) Terminal block (Transmission cable and monitor output) Terminal block (M-NET Transmission cable) Connector(Power supply) Control circuit transformer Relay contact CN1: CN2: CN5: CN6: CN7: TAB3: TAB5: CN9: CN10: CN16: CN32: SA1: SA2: SYMBOL Connector (Transformer primary) Connector (Transformer secondary) Connector (Thermistor) Connector (Microswitch) Connector (Motor for By-pass operation) Tab connector(Fan motor) Tab connector (Fan motor) Connector (Fan motor) Connector (Fan motor) Connector (High/Low/By-pass switch) Connector (Remote control selection) Address setting rotary switch (10 digit) Address setting rotary switch (1 digit) : Indicates terminal block. : Connector. : Board insertion connector or fastening connector of control board. M1: M2: C: GM: LS: TH1: TH2: SW1: SW2, 5: TM1: TM2: TM3: TM4: Motor for exhaust fan Motor for supply fan Capacitor Motor for By-pass operation Microswitch Thermistor for outside air Thermistor for return air Switch (Main/Sub change) Switch (Function selection) Terminal block (Power supply) Terminal block(External control input) Terminal block (Monitor output) Terminal block (Transmission cable and monitor output) TB5: Terminal block (M-NET Transmission cable) TAB1,TAB2: Connector(Power supply) TR1: Control circuit transformer TR2,TR3: By-pass operation transformer X10,X11,X12: Relay contact X101,X102,X103: Relay Supply fan speed control X201,X202,X203: Relay Exhaust fan speed control CN1: Connector (Transformer primary) CN2: Connector (Transformer secondary) CN5: Connector (Thermistor) CN6: Connector(Microswitch) CN7: Connector (Motor for By-pass operation) CN9: Connector (Fan motor) TAB3: Tab connector (Fan motor) TAB5: Tab connector (Fan motor) CN9: Connector (Fan motor) CN10: Connector (Fan motor) CN16: Connector(High/Low/By-pass switch) CN32: Connector (Remote control selection) SA1: Address setting rotary switch (10 digit) SA2: Address setting rotary switch (1 digit) SYMBOL : Indicates terminal block. Board insertion connector or fastening connector of control board. 24 Sample Installations LGH-15RX5 to 100RX5 LGH-150RX5 and 200RX5 Exhaust air grille A Exhaust grille (user supplied) Suspension bolt position Suspension bolt position Air-supply grille (user supplied) 150 to 250 600 or more Suspension bolt position Inspection opening LOSSNAY core/ air filter/ fan maintenance space Supply air grille 414 Air-supply grille (user supplied) OA (fresh-air intake) Duct (user supplied) Duct diameter 200 (ordered by customer) 450( 600) Inspection port Duct (user supplied) EA (Exhaust air) OA (Outside air) Suspension bolt position (ordered by customer) Exhaust grille (user supplied) EA (exhaust-air outlet) Inspection opening RA (Return air) Duct diameter 200 (user supplied) Heat exchanger/filter maintenance space Y piping,Dwindle pipe (user supplied) Ceiling suspension bolt position Air-supply grille (user supplied) Supply/ exhaust air grille SA (Supply air) •Always leave inspection holes ( 450 or 600) on the air filter and LOSSNAY core removal side. • Always insulate the two ducts outside the room (intake air and exhaust air ducts) to prevent condensation. •It is possible to change the direction of the outside air ducts (OA and EA side). • Do not install the vent cap or round hood where it will come into direct contact with rain water. Unit: mm Ceiling suspension bolt position B OA (Outside air) Duct diameter 250 Ceiling suspension (user supplied) bolt position A 150~250 Min. 600 B 414 EA (Exhaust air) Duct downward slope 1/30 or more (to wall side) (Rainwater entrance prevention) Deep-type hood or weather cover LOSSNAY model selection advices Duct incline Over 1/30 (toward the wall) to prevent entry of rainwater EA (exhaust-air outlet) Ceiling suspension bolt (user supplied) (user supplied) OA (fresh-air intake) Exhaust grille 450( 600) Inspection port Air-supply grille SA RA SA RA (return air) (return air) (supply air) (supply air) •Always leave inspection holes ( 450 or 600) on the air filter and LOSSNAY core removal side. • Always insulate the two ducts outside the room (intake air and exhaust air ducts) to prevent condensation. •If necessary, order a weather cover to prevent rain water from direct contact or entering the unit. Model A B LGH-15RX5 768 782 LGH-25RX5 768 782 LGH-35RX5 875 921 LGH-50RX5 875 1063 LGH-65RX5 895 1001 Model A B LGH-80RX5 1010 1036 LGH-150RX5 1010 1045 LGH-100RX5 1010 1263 LGH-200RX5 1010 1272 Unit: mm Attention for specifications 1.Cold operation mode(*1) is to start repeating in the case that LOSSNAY's detected OA temperature is less than-10°C. *1.Supply air(SA) in the operation for 60min. followed by stop operation for 10min. 2.The current, power consumption and efficiency are based on the air flow rate in the specification. 3.Fan speed is selectable by the remote controller from High (Extra-High), Low, Extra-Low(Extra-Low not equipped LGH150RX5 and 200RX5). Multi Ventilation Mode should set on LOSSNAY unit or remote controller (PZ-60DR-E). 4.LOSSNAY ventilation mode is to start automatically in the case that LOSSNAY's detected OA temperature is less than +8°C,even if By-pass ventilation is set by remote controller. Remote controller continue to show "By-pass ventilation" in this case. 5.Temperature Exchange efficiency(%) are based on winter condition. 6.Mitsubishi Electric measures the machine according to the Japan Industrial Standards(JIS B 8628) Attention 1.When using the product where it is exposed to high temperatures and humidity (40°C or higher, RH 80% or higher), or where fog occurs frequently, moisture is likely to condense in the core, and may result in condensation build up in the unit.The product should not be used under such conditions. 2.Outdoor air may enter the LOSSNAY owing to the pressure difference between indoor and outdoor or external winds even when the product is not operated. It is recommended to install an Electrically operated damper to block the outdoor air. 3.In a cold weather area, an area with strong external winds or where fog occurs frequently, cold outdoor air, external winds or fog may be introduced into the product when its operation is stopped. It is recommended to install an Electrically operated damper. 4.In a cold weather area, or others, dewing or freezing could occur on the main unit, where the duct is connected, or other sections, depending on the conditions of outdoor air and indoor temperature and moisture, even if they are within the range of operating conditions. Make sure to confirm the operating conditions and other precautions, and do not use the product if dewing or freezing is anticipated. 5.The outside ducts must be tilted at a gradient (1/30 or more) down toward the outdoor louvres from LOSSNAY, and properly insulated. (The entry of rain water may cause power leakage, fire, or damege to household property) 6.The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming. If it is expected that the ambient temperature around the place where the LOSSNAY unit is installed will be high during the summer air conditioning season, it is recommended that the indoor ductwork be covered with insulation material. 7.Inspection opening (450 × 450 or 600 × 600mm)must be installed on the filter and LOSSNAY core removing side. 25 1.Operating environment Install this product in an environment where the temperature ranges from -10°C to +40°C and the relative humidity is less than 80%RH. If condensation is expected to form,heat up the fresh outside air should be treated. 2.Do not use under high temperature and humidity condition Condensation will occur and water will gather inside the LOSSNAY cores under high temperature and humidity condition, such as warm swimming pool, bathroom, greenhouse or foggy place. 3.Condition of outdoor, indoor and return air Avoid using LOSSNAY under air condition with acid, alkalis, organic solvent , oil mist, paint, or harmful gas as presticide, corrosive gas, etc. 4.Insulation failure caused by salt or sulphur air and hot spring steam, Rust, fire or malfunction may occur. Installing high quality filters inside outdoor air duct if the LOSSNAY operates in salt or sulphur air conditions. 5.Intake of mist or outdoor air during off-mode operation Outdoor air or mist may flow through the duct into your room when LOSSNAY is in off-mode at windy and foggy area. To prevent intake of outdoor air or fog, a damper is advised to be installed. 6.Entry of insects When using the product in an environment where there is a window,or opening near the outdoor hood,so that insects are likely to gather around the interior or exterior light,take note that small insects may intrude into the LOSSNAY filters. 7.By-pass ventilation In the case of "By-pass" ventilation, the supply air temperature slightly rises more than the outside air temperature. because of the effect around the ducts or the unit motors. 8.Usage of M-NET. When solely using LOSSNAY units, power supply unit is required to connect to centralized control. Number of power supply units or the transmission boosters should correspond with the connected LOSSNAY units. Caution for installation 1.Do not modify the unit as it may cause malfunction. 2.Leaving sufficient space for maintenance purpose. 3.The location of the air inlet Take care in locating air inlet to prevent intake of dirty air or disgusting smell from exhaust gas of factory, air from rubbish disposal, etc. 4.Take precautions when using the product in quiet location. 5.Heat insulation foam for duct Take care as below to prevent the contaminate ceiling by duct condensation. 1)The two outdoor ducts(OA and EA) must be covered with heat-insulating material in order to prevent condensation. 2)If it is expected that the ambient temperature around the place where the LOSSNAY unit is installed will be high during the summer air conditioning season, it is recommended that the indoor ductwork be covered with insulation material. 3)Outdoor air may come into unit during not operating unit by the pressure difference between indoor and outdoor or the outdoor wind. In this case you should install a damper. 4)It is possible for condensation and freezing to occur in the cold regions inside the unit because of the outdoor air condition or humidity condition above ceiling. Make sure to install supplemental insulation foam. 5)In the case that air condition around LOSSNAY unit is high temperature in summer, it is recommended that there are heat insulation foam on indoor side duct to prevent heat recovery decreased by warming indoor duct. In winter, it is possible to cool indoor side duct without heat insulation foam on indoor side duct. 6.Prevent entry of rainwater into LOSSNAY unit Install weather louvre or "Weather cover" for OA inlet & EA outlet. This is to prevent rainwater entering the LOSSNAY unit. Ducts to outdoor (OA and EA) should decline by 1/30 or more. 1)Install the anchor bolts to ensure the product's weight or earthquake load. (Correctly rated wire/chain may also be used) 2)Do not install this product in a place where it is exposed to ultraviolet light. (UV may be damage covering insulation.) 7.Electrical Work A single pole isolator must be installed at the origins of mains power supply. Use single flush box, to support remote controller. Must connect ground wiring. When connecting external devices (electrically operated damper, lamp, monitoring unit, etc.) using output signals of the LOSSNAY unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment) 26