Preview only show first 10 pages with watermark. For full document please download

Rzqsg-l8y1 Technical Data (eeden13

   EMBED


Share

Transcript

Air Conditioning Technical Data EEDEN13-100 RZQSG-L(8)Y1 • Outdoor Unit • • RZQSG-L(8)Y1 TABLE OF CONTENTS RZQSG-L(8)Y1 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Options 5 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Cooling Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Capacity Correction Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 10 12 20 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Piping Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Piping Diagram Twin Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Piping Diagram Triple Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Piping Diagram Double Twin Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 22 23 24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Sound Power Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound Pressure Spectrum Quiet Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Installation Method 13 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Wiring Diagrams - Three Phase 11 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Centre of Gravity 9 10 Combination table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Dimensional Drawings 8 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Combination Table 6 7 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 5 • Split - Sky Air • Outdoor Unit 27 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation Range 26 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 1 • Outdoor Unit • • RZQSG-L(8)Y1 1 k i1 SYn )U 8 - ( r L o t - o Gi d S l t Q puZ S•OR • 1 1 Features Seasonal classic series already comply with EU’s 2014 Eco-Design requirements Top efficiency: - new compressor that offers substantial efficiency improvements - new control logic that optimises efficiency at the most frequently encountered operating conditions and that optimises the auxiliary modes (when the unit is not active) - newly designed heat exchangers that optimise the refrigerant flow at the most frequent operating conditions (temperature and load) - via improved nominal performances Inverter 2 • Split - Sky Air • Outdoor Unit • Re-use of existing R-22 or R-407C technology • Guarantees operation in heating mode down to -15ºC • Maximum piping length up to 50m, minimum piping length is 5m. • Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall • Seasonal efficiency, optimized for all seasons. • Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season. • Outdoor Unit • • RZQSG-L(8)Y1 2 Specifications 2-1 Nominal Capacity And Nominal Input Cooling capacity Nom. Heating capacity Nom. Seasonal efficiency (according to EN14825) Cooling FCQHG125F/RZQSG125L8Y1 FCQHG140F/RZQSG140LY1 kW 9.5 12.0 13.4 kW 10.8 13.5 15.5 A++ A - 9.50 12.00 - 1 6.70 5.40 - 496 777 - 2 Energy label Pdesign kW SEER Annual energy consumption Heating (Average climate) kWh Energy label Pdesign kW SCOP Annual energy consumption EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling 3 FCQHG100F/RZQSG100L8Y1 kWh kWh A+ - 8.03 - 4.30 4.10 - 2,614 2,741 - 3.70 3.23 3.21 4.30 3.75 3.61 1,855 2,085 1,285 Heating A - A - Notes (1) EER/COP according to Eurovent 2012 2-1 Nominal Capacity And Nominal Input FCQG100F/RZQSG100L8Y1 FCQG125F/RZQSG125L8Y1 FCQG140F/RZQSG140LY1 Cooling capacity Nom. kW 9.5 12.0 13.4 Heating capacity Nom. kW 10.8 13.5 15.5 Seasonal efficiency (according to EN14825) Cooling A++ A - 9.50 12.00 - 6.50 5.30 - kWh 511 792 - kW 7.60 8.03 - 4.10 4.01 - kWh 2,595 2,803 - 3.30 3.21 Energy label Pdesign kW SEER Annual energy consumption Heating (Average climate) Energy label Pdesign A+ SCOP Annual energy consumption EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling - 3.54 kWh Heating 3.01 3.41 1,440 1,870 2,225 A - B - Notes (1) EER/COP according to Eurovent 2012 2-1 Nominal Capacity And Nominal Input FAQ100C/RZQSG100L8Y1 Cooling capacity Nom. kW 9.5 Heating capacity Nom. kW 10.8 Seasonal efficiency (according to EN14825) Cooling kW 9.50 Energy label Pdesign A+ SEER Annual energy consumption Heating (Average climate) 5.61 kWh 592 kW 6.81 kWh 2,377 Energy label Pdesign A+ SCOP Annual energy consumption 4.01 • Split - Sky Air • Outdoor Unit 3 • Outdoor Unit • • RZQSG-L(8)Y1 2 Specifications 2-1 Nominal Capacity And Nominal Input 1 EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling FAQ100C/RZQSG100L8Y1 3.01 3.41 kWh 1,580 B Heating 2 B Notes (1) EER/COP according to Eurovent 2012 2-1 Nominal Capacity And Nominal Input FVQ100C/RZQSG100L8Y1 FVQ125C/RZQSG125L8Y1 Cooling capacity Nom. kW 9.5 12.0 13.4 Heating capacity Nom. kW 10.8 13.5 15.5 Seasonal efficiency (according to EN14825) Cooling kW 9.50 12.00 - kWh 604 763 - Energy label Pdesign A SEER Annual energy consumption Heating (Average climate) A+ kW EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling - A - 7.60 SCOP Annual energy consumption - 5.50 Energy label Pdesign FVQ140C/RZQSG140LY1 kWh - 4.01 3.85 - 2,653 2,763 - 3.21 2.81 3.61 kWh 3.01 3.41 1,480 2,135 2,225 A C - A B - FBQ100C8/RZQSG100L8Y1 FBQ125C8/RZQSG125L8Y1 FBQ140C8/RZQSG140LY1 Heating Notes (1) EER/COP according to Eurovent 2012 2-1 Nominal Capacity And Nominal Input Cooling capacity Nom. kW 9.5 12.0 13.4 Heating capacity Nom. kW 10.8 13.5 15.5 Seasonal efficiency (according to EN14825) Cooling kW 9.50 12.00 - 5.50 5.20 - 604 807 - Energy label Pdesign A SEER Annual energy consumption Heating (Average climate) kWh Energy label Pdesign A+ kW SCOP Annual energy consumption EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling kWh kWh Heating Notes (1) EER/COP according to Eurovent 2012 4 • Split - Sky Air • Outdoor Unit - A 7.60 - 4.01 3.90 - 2,653 2,728 - 3.31 3.21 3.02 3.65 3.51 3.41 1,435 1,870 2,220 A A B - • Outdoor Unit • • RZQSG-L(8)Y1 2 Specifications 2-1 Nominal Capacity And Nominal Input Cooling capacity Nom. Heating capacity Nom. Seasonal efficiency (according to EN14825) Cooling kW 12.0 kW 13.5 kW 12.00 1 5.20 2 Energy label Pdesign A SEER Annual energy consumption Heating (Average climate) kWh 807 kW 7.60 kWh 2,728 Energy label Pdesign A SCOP Annual energy consumption EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling 3 FDQ125C/RZQSG125L8Y1 3.90 3.21 3.51 kWh 1,600 A Heating B Notes (1) EER/COP according to Eurovent 2012 2-1 Nominal Capacity And Nominal Input FHQ100C/RZQSG100L8Y1 FHQ125C/RZQSG125L8Y1 FHQ140C/RZQSG140LY1 Cooling capacity Nom. kW 9.5 12.0 13.4 Heating capacity Nom. kW 10.8 13.5 15.5 Seasonal efficiency (according to EN14825) Cooling Energy label Pdesign A+ kW SEER Annual energy consumption Heating (Average climate) kWh EER Nominal efficiency (cooling at 35º/27º COP nominal load, heating Annual energy consumption at 7º/20º nominal load) Energy label Cooling - 748 - - 592 A kW SCOP Annual energy consumption 12.00 5.61 Energy label Pdesign - 9.50 kWh kWh A+ 7.60 - 3.91 4.01 - 2,721 2,653 - 3.21 2.89 3.01 3.61 3.62 3.41 1,480 2,075 2,225 A C Heating A - Notes (1) EER/COP according to Eurovent 2012 2-2 Technical Specifications RZQSG100L8Y1 RZQSG125L8Y1 Capacity control Method Casing Colour Ivory white Material Painted galvanized steel plate Dimensions Unit Packed unit Weight Heat exchanger RZQSG140LY1 Inverter controlled Height mm Width mm Depth mm Height mm Width mm Depth mm 990 1,430 940 320 1,170 1,610 1,015 422 Unit kg 82 101 Packed unit kg 94 114 Fin Type Treatment • Split - Sky Air • Outdoor Unit WF fin Anti-corrosion treatment (PE) 5 • Outdoor Unit • • RZQSG-L(8)Y1 2 Specifications 2-2 Technical Specifications Compressor RZQSG100L8Y1 Fan Hermetically sealed swing compressor Starting method Inverter driven Type Propeller fan Discharge direction 2 Horizontal Quantity Air flow rate Fan motor 1 Cooling Nom. m³/min Super low m³/min Heating Nom. m³/min Super low m³/min 2 76 77 83 62 - cfm 1 2 Model Brushless DC motor Output W 200 Drive 94 Direct drive Cooling Super low rpm - Heating Super low rpm - Sound power level Cooling Nom. dBA 69 70 Sound pressure level Cooling Nom. dBA 53 54 53 Heating Nom. dBA 57 58 54 Operation range Night quiet mode Level 1 dBA Cooling Ambien Min. t Max. ºCDB -5 ºCDB 46 Heating Refrigerant Ambien Min. t Max. ºCWB -15 ºCWB 15.5 R-410A kg Control 2.9 Refrigerant oil Type Piping connections Liquid 1,975 Quantity 1 FVC50K Charged volume l Quantity mm Quantity 9.52 1 Type Flare connection OD mm Quantity 15.9 5 Type Piping length 1.35 Flare connection OD Drain 0.9 1 Type Gas 4.0 Expansion valve (electronic type) GWP Circuits 69 49 Type Charge Hole ID mm - OD mm 26 OU - IU Min. m 5 Max. m 50 System Equival m ent 70 Chargel m ess 30 Additional refrigerant charge kg/m Level difference IU - OU Max. m IU - IU m Max. Heat insulation 6 83 - cfm Quantity Speed RZQSG140LY1 1 Type 1 RZQSG125L8Y1 Quantity See installation manual 30.0 0.5 Both liquid and gas pipes Defrost method Reversed cycle Defrost control Sensor for outdoor heat exchanger temperature • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 2 Specifications 2-2 Technical Specifications Safety devices RZQSG100L8Y1 Item High pressure switch 02 Fan driver overload protector 03 Fuse 2-3 Electrical Specifications Power supply RZQSG125L8Y1 01 RZQSG100L8Y1 RZQSG125L8Y1 Name 1 RZQSG140LY1 2 3N~ Frequency Hz 50 Voltage V 380-415 Min. % 10 Max. % Voltage range Zmax 10 List Complies to EN61000-3-11 Recommended fuses A Maximum fuse amps (MFA) A Current - 60Hz Maximum fuse amps (MFA) A Wiring connections For power supply Remark See installation manual outdoor unit For connection with indoor Remark See installation manual outdoor unit Current - 50Hz 3 Y1 Phase Current RZQSG140LY1 Power supply intake 20 25 20 - Outdoor unit only Notes (1) PED: assembly = category l : excluded from scope of PED due to article 1, item 3.6 of 97/23/EC (2) See separate drawing for electrical data • Split - Sky Air • Outdoor Unit 7 • Outdoor Unit • • RZQSG-L(8)Y1 3 Electrical data 3-1 Electrical Data 1 3 8 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 3 Electrical data 3-1 Electrical Data 3 1 3 • Split - Sky Air • Outdoor Unit 9 • Outdoor Unit • • RZQSG-L(8)Y1 4 Options 4-1 Options 1 4 10 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 5 Combination table 5-1 Combination Table 3 1 5 • Split - Sky Air • Outdoor Unit 11 • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-1 Cooling Capacity Tables 1 6 12 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-1 Cooling Capacity Tables 3 1 6 • Split - Sky Air • Outdoor Unit 13 • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-1 Cooling Capacity Tables 1 6 14 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-2 Heating Capacity Tables 3 1 6 • Split - Sky Air • Outdoor Unit 15 • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-2 Heating Capacity Tables 1 6 16 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-2 Heating Capacity Tables 3 1 6 • Split - Sky Air • Outdoor Unit 17 • Outdoor Unit • • RZQSG-L(8)Y1 6 Capacity tables 6-3 Capacity Correction Factor 1 6 18 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 7 Dimensional drawings 7-1 Dimensional Drawings 3 1 7 • Split - Sky Air • Outdoor Unit 19 • Outdoor Unit • • RZQSG-L(8)Y1 8 Centre of gravity 8-1 Centre of Gravity 1 8 20 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 9 Piping diagrams 9-1 Piping Diagrams 3 1 9 • Split - Sky Air • Outdoor Unit 21 • Outdoor Unit • • RZQSG-L(8)Y1 9 Piping diagrams 9-2 Piping Diagram Twin Application 1 9 22 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 9 Piping diagrams 9-3 Piping Diagram Triple Application 3 1 9 • Split - Sky Air • Outdoor Unit 23 • Outdoor Unit • • RZQSG-L(8)Y1 9 Piping diagrams 9-4 Piping Diagram Double Twin Application 1 9 24 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 10 Wiring diagrams 10 - 1 Wiring Diagrams - Three Phase 3 1 10 ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ ∼ • Split - Sky Air • Outdoor Unit 25 • Outdoor Unit • • RZQSG-L(8)Y1 11 Sound data 11 - 1 Sound Power Spectrum 1 11 26 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 11 Sound data 11 - 2 Sound Pressure Spectrum - Cooling 3 1 11 • Split - Sky Air • Outdoor Unit 27 • Outdoor Unit • • RZQSG-L(8)Y1 11 Sound data 11 - 3 Sound Pressure Spectrum - Heating 1 11 28 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 11 Sound data 11 - 4 Sound Pressure Spectrum Quiet Mode 3 1 11 • Split - Sky Air • Outdoor Unit 29 • Outdoor Unit • • RZQSG-L(8)Y1 12 Installation 12 - 1 Installation Method 1 12 30 • Split - Sky Air • Outdoor Unit • Outdoor Unit • • RZQSG-L(8)Y1 12 Installation 12 - 1 Installation Method 3 1 12 • Split - Sky Air • Outdoor Unit 31 • Outdoor Unit • • RZQSG-L(8)Y1 13 Operation range 13 - 1 Operation Range 1 13 32 • Split - Sky Air • Outdoor Unit The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. BARCODE Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende EEDEN13-100 • 03/13 • Copyright Daikin The present publication supersedes EEDEN12-100 Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com”