S 1635
STRICTLY FOR INTERNAL USE
PRODUCT DATA SHEET 2005
Product range
DC inverter split wall mounted
Model
S 1635 in/out
Brand name Colour
EAN code indoor unit
EAN code outdoor unit
Zibro
white
8713508726588
8713508726595
TECHNICAL SPECIFICATIONS EER* / COP*
W/W
EE-class* / Heating performance*
Capacity *
kW
Capacity range *
kW
Power consumption
Mains Voltage Amperage
Air flow (max.) indoor unit **
For rooms up to **
kW V/Hz/Ph
m /h
Moisture removal *** Operating range
Thermostatic range *
**
EN 14511
A 3
m
3
L/d °C °C
Cooling
Heating
A
A
3.21
3.82
3.5
5.0
1.0 - 3.5
1.2 - 5.0
1.0
1.04
220-240 / 50 / 1 4.5
570
4.6
100
600
41
-10 °C to +43°C 16 - 30
Noise level in-/outdoor**
Fan speed
dB
Generated negative ions qtty/cc
Control
Cooling
Heating
25-40 / 45 25-42 / 46 3 positions 9000
Electronic Remote
Air filter
type
Screen, Enzyme, Active carbon
Dim. indoor (w x d x h)
mm
795 x 182 x 265
Refrigerant type / charge R / gr
Dim. outdoor (w x d x h)
Compressor type
Protection class in-/outdoor
Weight in-/outdoor
mm
kg
R410A / 1100 gr 710 x 255 x 545 Rotary
IP X0 / IP X4 9 / 29.0
Guarantee
years
2
Manual
2 6 5 3 4 > 1 :
To be used as indication
*** Moisture removal at 32°C, 80% RH
ACCESSORIES
Remote control
Remote control holder AAA batteries (2 pcs.)
Cap screw (2 pcs.)
Active carbon filter
Mounting plate
Enzyme filter
MOST IMPORTANT SPAREPARTS
Spare part description
EAN Code
Remote control holder
8713508
Remote control
P V G
8713508
Spare part description Active carbon filter Enzyme filter
EAN Code 8713508 8713508 uk© 11-mrt-2005
S 1635
FEATURES
Inverter: The Zibro DC Inverter split wall mounted air-conditioner continuously adjusts the cooling and heating capacity according to the desired room temperature. When the desired temperature is reached, the compressor speed is gradually decreased to maintain the room temperature with a minimum of variation. By varying this compressor capacity comfort and energy efficiency will increase.
Non-inverter air conditioners that operate at a constant speed must turn on/off the compressor to control the room temperature causing less comfortable temperature fluctuations.
Inverter type
Power consumption: The compressor starts to slow down as the room temperature reaches the desired temperature. As a result, the over all power consumption is reduced significantly (till 35% less than non inverter / conventional types).
Air conditioning: In COOLING mode the unit produces, with high energy efficiency, a pleasant and refreshing high capacity cool airflow. Heating: In HEATING mode the unit produces, with high energy efficiency, a warm and comfortable airflow.
Dehumidification: In DRY mode the unit operates as dehumidifier only. Note: In COOLING mode the air is dehumidified also. Conventional type
Automatic operation: The air conditioning system can be set to automatic operation for the most suitable mode; Cooling, Dry or Heating, monitoring the indoor temperature.
Remote control: The unit can be controlled with an easy to handle remote control including LCD-display. The remote control can be used up to a distance of approx. 7 meters.
Remote control holder: The remote control can be placed in the wall-mounted holder, delivered together with this unit. Auto recovery function: If there is any power failure during operation, the operation status before power failure is memorized and the unit starts operation automatically after power recovery.
Fan speed setting: Select with the FAN speed button: Automatic, Low, Medium or High. The LCD display on the remote control will show the chosen speed.
Timer: Use TIMER to set an ON or OFF between 10 minutes and 24 hours. The preset time appears in the display of the remote control. The unit switches ON or OFF automatically when this time has run down.
Sleep timer: This function can stop operation automatically after the interval set (max. 7 hours) by the remote control. In this function the set temperature will automatically go up or down, respectively depending on the operating mode COOLING or HEATING, with 1.2 ºC over 1 hour. After the programmed time the unit will stop automatically. Temperature setting: When switched on, the display will show the room temperature. The desired temperature can be set between 16 and 30°C. Note: actual result is up to specific room conditions.
Emergency button: If the remote control is not usable/available; the emergency button can be used to operate the unit. The unit will operate in automatic mode then. Ionizer / negative ion generator: The integrated IONIZER creates 9000 negative ions per cc off air passing the unit. This to achieve a better natural equilibrium (balance) between positive and negative ions.
Air filtration: This air conditioner is equipped with two “3 layer filters” to clean the circulated room air. The screen filter removes the larger (dust) particles. The enzyme filter neutralizes airborne micro organisms caught on the surface of this filter, resulting in protection against secondary contamination. The active carbon filter removes unpleasant odours from the air.
Filter package: Frequently renewal of the Active carbon and Enzyme filters is recommended. Refreshment filter sets are available in a consumer package. The screen filter can easily be cleaned with a vacuum cleaner or with lukewarm water. Airflow: To adjust the airflow direction, the horizontal louvers can be moved by pushing the “Louver” button on the remote control. The vertical louvers can be adjusted manually. Design: This DC inverter air conditioner is part of an exclusive range of Zibro products.