Preview only show first 10 pages with watermark. For full document please download

S 3vl96008lc01 Item: Wbmmfm For Use With Frame Mg

   EMBED


Share

Transcript

s U.S. Cat. No. Item: Euro Order No. WBMMFM 3VL96008LC01 Walking-Beam Interlock Módulo de enclavamiento recíproco para interruptores adyacentes Module d'interverouillage mécanique For Use With Frame MG Para Usar Con Caja Base MG Installation Instructions / Instructivo de Instalación Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Tension dangereuse. Danger de mort ou risque de blessures graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. Use only with Siemens certified Components. Utilizar únicamente con componentes certificados de Siemens. A utiliser uniquement avec les composants certifiés Siemens. Ø = .22“ [ Ø = 5.5 mm ] NOTE - These instructions do not purport to cover all details or variations in equipment, or to provide for every possible contingency to be met in Ø = .28“ [ Ø = 7.1 mm ] connection with installation, operation or maintenance. Should further information be desired or should particular problems arise, which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Siemens sales office. The contents of this Instruction manual shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties is the sole warranty of Siemens. Any statements contained herein do not create new warranties or modify the existing warranty. Trademarks - Unless otherwise noted, all names identified by ® are registered trademarks of Siemens AG or Siemens Industry, Inc. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. SEAMB SEAMM SEAMY SEAMN SEAMR 3VL9600-3MJ01 = 24 Vdc 3VL9600-3ML01 = 42-48 V ac/dc 3VL9600-3MS01 = 60 V ac/dc 3VL9600-3MN01 = 110-127 V ac/dc 3VL9600-3MQ01 = 220-250 V ac/dc 5 mm 10mm Cal ISO 6789 10 mm Notice: Control circuit interlocking recommended to prevent unintended operation of the motor operator in conflict with the walking beam interlock. [ Aviso: El enclavamiento del circuito de control es recomendado para prevenir la operación involuntaria del accionamiento de motor en conflicto con el modulo de enclavamiento mecánico. ] 2X M5 X 20 mm 4X M5 X 16mm 4X M5 X .8 - 2X 806892_ _ _ 1/9 8 0 6 8 9 5 A 0 1 WBMMFM / 3VL96008LC01 6X M5 - 2X a b - 2X c - 2X d - 4X M4 X 12 I.L. No. 806895A01 Front Connect – MG 3 + 4 Pole [ Conexión Frontal – MG 3 + 4 Polos ] 9.75 [247.5] 5.30 [134.5] Supplied by Customer: [ Proveído por el Cliente: ] Y 3.41 [86.5] X 1.42 [36.0] 14.99 [381.0] 11.66 [296.0] 8.41 [213.5] 6.91 [175.5] 4.91 [125.0] 3X Ø.28 [Ø7.0] Y .57 [14.5] .16 [4.0] 3.59 [91.0] X 2X Ø.21 [Ø5.0] 1.05 [26.5] 4X Ø.23 [Ø5.5] 90° Screw Head Flush to Panel 1.08 [27.5] 2.66 [67.5] 4X Ø.28 [Ø7.0] (3P) 6X Ø.28 [Ø7.0] (4P) Cold Rolled Steel [ Acero rollado en frio ] 6.14 [156.0] 1.25 [31.5] (3P + 4P) 1.25 [32.0] (3P) 3.75 [95.0] (4P) 19.87 [504.5] Supplied by Customer: [ Proveído por el Cliente: ] 9.78 [248.5] (4P) 7.28 [185.0] (3P) Rear Connect – MG 3 + 4 Pole [ Conexión Trasera – MG 3 + 4 Polos ] 3.64 [92.5] 14.99 [381.0] 9.75 [247.5] 5.80 [147.5] 5.30 [134.5] 10.78 [274.0] 2.30 [58.5] Y X 11.66 [296.0] 8.41 [213.5] 6.91 [175.5] 4.91 [125.0] Y 3X Ø.28 [Ø7.0] 3.41 [86.5] 2.66 [67.5] 1.42 [36.0] .16 [4.0] 3.59 [91.0] 1.08 [27.5] 2X Ø.21 [Ø5.0] 4X Ø.23 [Ø5.5] 90° 1.05 [26.5] Screw Head Flush to Panel 4X Ø.28 [Ø7.0] (3P) 6X Ø.28 [Ø7.0] (4P) X .57 [14.5] 2.30 [58.5] 6.14 [156.0] Cold Rolled Steel [ Acero rollado en frio ] 1.25 [31.5] (3P + 4P) 1.25 [32.0] (3P) 3.75 [95.0] (4P) 19.87 [504.5] Supplied by Customer: [ Proveído por el Cliente: ] .12 – .24” [ 3 – 6 mm ] 32 .51” [ 13 mm ] 3X M6 nut [ 3X M6 tuerca ] 3 .12” [ 3 mm ] 3X - M6 18 lb. in. 32] 13 [ 2.0 Nm ] 1.26”[ 32 mm Cold Rolled Steel [ Acero rollado en frio ] 2/9 806895A01 Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Tension dangereuse. Danger de mort ou risque de blessures graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. 1 Trip [ Interrumpir ] & Circuit Breaker A [ Interruptor A ] 2 Circuit Breaker B [ Interruptor B ] a 2 1 3 3 b d OFF / O ON / I 2X M4 X 12 c a 2X 4 lb. in. [ 2X 0.5 Nm ] 1 b 2 4 3 5 2 2X 1 4 3/9 806895A01 5 2X M5 2X M5 X 20 mm 2X 27 lb. in. [ 2X 3.0 Nm ] 6 4X M5 X 16mm - 4X M5 4X M5X .8 - 4X 18 lb. In. [ 4X 2.0 Nm ] 7 1 2 4/9 806895A01 Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Tension dangereuse. Danger de mort ou risque de blessures graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. 8 1 3 2 X 360º 2 6 mm 18 lb. In. [ 2.0 Nm ] 9 OFF / O ON / I 8X 1/4 – 20 X 4.50” 8X 35 lb. in. [ 8X 4 Nm ] General information: [ Información General: ] 15.00” [ 381 ] 6.65” [ 169 ] 3.86” [ 98 ] 2.76” [ 70 ] 2.74” [ 69.5 ] 21.00” [ 533 ] 5/9 806895A01 10 ON / I OFF / 0 11 X>0 1 + + 2 X=0 X 2 1 9 Lbf [ 40 N ] X OFF / 0 ON / I 6/9 806895A01 Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. 12 Tension dangereuse. Danger de mort ou risque de blessures graves. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. 13 Ex: OFF / 0 OFF / 0 14 3X[ 3X - 1½ X- Total MAX Máximo Total ] WARNING Excessively High Temperatures will cause Equipment Damage. Follow adjustment steps 13 - 21 Carefully. Advertencia OFF / 0 Excesivas altas temperaturas causara daño al equipo. OFF / 0 Siga los pasos de ajuste 13 - 21 Cuidadosamente. 7/9 806895A01 15 35 lb.in. [ 4 Nm ] Test: [ Prueba: ] 16 A EX: 16 - a B ON / I OFF / 0 Result [ Resultado ] ON / I 16 - a OFF / O 16- b OFF / O ON / I 16 - C OFF / O ON / I 16 - d OFF / O 16 - e OFF / O 16 - f OFF / O Repeat [ Repetir ] B A ON / I ON / I OFF / O ON / I OFF / O OFF / O ON / I ON / I OFF / O 8/9 A B ON / I ON / I OK 5X ON / I ON / I OK 5X ON / I ON / I OK 5X OFF / O OFF / O OK 1X OFF / O ON / I OK 1X ON / I OFF / O OK 1X 806895A01 Hazardous Voltage. Will cause death or serious injury. Tensión peligrosa. Puede causar la muerte o lesiones graves. Turn off and lock out all power supplying this device before Desenergice totalmente antes de instalar o darle servicio. working on this device. Reemplace todas las barreras y cubiertas antes de Replace all covers before power supplying this device is energizar el interruptor. turned on. 17 OK Test: = [ Prueba: ] OK Tension dangereuse. Danger de mort ou risque de blessures graves. Couper l'alimentation de l'appareil et barrer avant de travailler. Remplacez touts les couverts avant que l'approvisionnement de pouvoir soit alimenté. Step 21 [ Paso 21 ] Step 18 [ Paso 18 ] 18 20 +½ X Step 14 [ Paso 14 ] 19 Step 16 [ Paso 16 ] Test: = OK Prueba: Step 15 [ Paso 15 ] 180° Step 21 [ Paso 21 ] 21 35 lb.in. [ 4 Nm ] For Support in Europe refer to : Bestell-Nr. / Order No.: 3ZX1012-0VL68-7AA4 Technical Support: Subject to change without prior notice Siemens Industry, Inc. , Norcross, GA 30092 U.S.A. Internet: www.siemens.de/lowvoltage/technical-assistance Toll Free: 1-800-241-4453 9/9 GWA 4NEB 179 6895-10 DS 02 Internet: www.usa.siemens.com/powerdistribution © Siemens Industry Inc. 2010 806895A01