Transcript
S-60
60W Single Output Switching Power Supply
series
Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 77KHz 2 years warranty
SPECIFICATION MODEL
OUTPUT
S-60-5
S-60-12
S-60-15
S-60-24
DC VOLTAGE
5V
12V
15V
24V
RATED CURRENT
12A
5A
4A
2.5A
CURRENT RANGE
0 ~ 12A
0 ~ 5A
0 ~ 4A
0 ~ 2.5A
RATED POWER
60W
60W
60W
60W
RIPPLE & NOISE (max.) Note.2 120mVp-p
120mVp-p
150mVp-p
150mVp-p
VOLTAGE ADJ. RANGE
10.8 ~ 13.2V
13.5 ~ 16.5V
21.6 ~ 26.4V
VOLTAGE TOLERANCE Note.3
INPUT
0.5%
0.5%
LOAD REGULATION
1.0%
0.5%
0.5%
0.5%
SETUP, RISE TIME
300ms, 50ms/230VAC
HOLD UP TIME (Typ.)
80ms/230VAC
VOLTAGE RANGE
85 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
73%
76%
AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
2A/115VAC 1A/230VAC COLD START 20A/115VAC
40A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed.
WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
OTHERS
NOTE
1.0%
0.5%
WORKING TEMP.
(Note 4)
1.0%
0.5%
OVER VOLTAGE
EMC
1.0%
LINE REGULATION
PROTECTION
SAFETY &
4.75 ~ 5.5V 2.0%
800ms, 50ms/115VAC at full load
12ms/115VAC at full load 120 ~ 370VDC
5.75 ~ 6.75V
77%
13.8 ~ 16.2V
17.25 ~ 20.25
79%
27.6 ~ 32.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed. -10 ~ +60
(Refer to output load derating curve)
20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3
/ 70% RH
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF DIMENSION
316.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H)
PACKING
0.51Kg; 24pcs/13.1Kg/0.7CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
File Name:S-60-SPEC 2010-10-18
S-60
60W Single Output Switching Power Supply Mechanical Specification
Case No. 901
series
Unit:mm
3.5
7
152.5
1
3
84.5
8.2
4 5
2-M
97
65
9.5
2
3
3.5 4.5 78
24
159 150
Terminal Pin No. Assignment
22
Pin No. 1 2 3
38
M3
3.5 28.5
9
3.5
3-
18
18.5
9
6.5
Assignment AC/L AC/N FG
Pin No. 4 5
Assignment DC OUTPUT -V DC OUTPUT +V
117
Block Diagram
fosc : 77KHz
RECTIFIERS & FILTER
EMI FILTER
I/P
RECTIFIERS & FILTER
POWER SWITCHING
DETECTION CIRCUIT
FG O.L.P.
+V -V
PWM CONTROL
O.V.P.
Static Characteristics (24V)
OUTPUT VOLTAGE (V)
100
80
LOAD (%)
60
40
20
-10 -10
Ta=25
Vo 32
0 0
10
20
30
40
50 45
AMBIENT TEMPERATURE ( )
60 55
(VERTICAL) (HORIZONTAL)
350
28
300
24
250
20
200
16
150
12
100
8
50
60
80
100
120
140
160
180
200
220
240
OUTPUT RIPPLE (mVp-p)
Derating Curve
260
INPUT VOLTAGE (V) 60Hz
File Name:S-60-SPEC 2010-10-18