Preview only show first 10 pages with watermark. For full document please download

S-60-12 даташит

   EMBED


Share

Transcript

S-60 60W Single Output Switching Power Supply series Features : Universal AC input / Full range Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 77KHz 2 years warranty SPECIFICATION MODEL OUTPUT S-60-5 S-60-12 S-60-15 S-60-24 DC VOLTAGE 5V 12V 15V 24V RATED CURRENT 12A 5A 4A 2.5A CURRENT RANGE 0 ~ 12A 0 ~ 5A 0 ~ 4A 0 ~ 2.5A RATED POWER 60W 60W 60W 60W RIPPLE & NOISE (max.) Note.2 120mVp-p 120mVp-p 150mVp-p 150mVp-p VOLTAGE ADJ. RANGE 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V VOLTAGE TOLERANCE Note.3 INPUT 0.5% 0.5% LOAD REGULATION 1.0% 0.5% 0.5% 0.5% SETUP, RISE TIME 300ms, 50ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY(Typ.) 73% 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 2A/115VAC 1A/230VAC COLD START 20A/115VAC 40A/230VAC LEAKAGE CURRENT <3.5mA / 240VAC OVERLOAD 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE OTHERS NOTE 1.0% 0.5% WORKING TEMP. (Note 4) 1.0% 0.5% OVER VOLTAGE EMC 1.0% LINE REGULATION PROTECTION SAFETY & 4.75 ~ 5.5V 2.0% 800ms, 50ms/115VAC at full load 12ms/115VAC at full load 120 ~ 370VDC 5.75 ~ 6.75V 77% 13.8 ~ 16.2V 17.25 ~ 20.25 79% 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed. -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1012, UL60950-1, TUV EN60950-1, CCC GB4943 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 / 70% RH EMS IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A MTBF DIMENSION 316.2K hrs min. MIL-HDBK-217F (25 159*97*38mm (L*W*H) PACKING 0.51Kg; 24pcs/13.1Kg/0.7CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) File Name:S-60-SPEC 2010-10-18 S-60 60W Single Output Switching Power Supply Mechanical Specification Case No. 901 series Unit:mm 3.5 7 152.5 1 3 84.5 8.2 4 5 2-M 97 65 9.5 2 3 3.5 4.5 78 24 159 150 Terminal Pin No. Assignment 22 Pin No. 1 2 3 38 M3 3.5 28.5 9 3.5 3- 18 18.5 9 6.5 Assignment AC/L AC/N FG Pin No. 4 5 Assignment DC OUTPUT -V DC OUTPUT +V 117 Block Diagram fosc : 77KHz RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING DETECTION CIRCUIT FG O.L.P. +V -V PWM CONTROL O.V.P. Static Characteristics (24V) OUTPUT VOLTAGE (V) 100 80 LOAD (%) 60 40 20 -10 -10 Ta=25 Vo 32 0 0 10 20 30 40 50 45 AMBIENT TEMPERATURE ( ) 60 55 (VERTICAL) (HORIZONTAL) 350 28 300 24 250 20 200 16 150 12 100 8 50 60 80 100 120 140 160 180 200 220 240 OUTPUT RIPPLE (mVp-p) Derating Curve 260 INPUT VOLTAGE (V) 60Hz File Name:S-60-SPEC 2010-10-18