Preview only show first 10 pages with watermark. For full document please download

S A Tp 40 10 D R

   EMBED


Share

Transcript

Solid State Relay SATP40 Series · Three-Phase solid-state relays ratings from 10A to 80A @ 40-530 VAC · 1200 Volts transient overvoltage · Removable IP 20 touch-safe cover · EMC Compliant for reliable operation in harsh environments · CE approved, RoHS compliant. · LED input status indicator · Strengthened current design for heavy industrial loads · Designed in according with the requirements of IEC 62314 · Zero-crossing (resistive loads) or instantaneous (inductive loads) output PRODUCT SELECTION Control Voltage 90-280 VAC 4-32 VDC 10A 15A 25A 30A 40A 60A 80A SATP4010A SATP4010D SATP4015A SATP4015D SATP4025A SATP4025D SATP4030A SATP4030D SATP4040A SATP4040D SATP4060A SATP4060D SATP4080A SATP4080D MODEL NAME DEFINITIONS Rated Current Style TP: 3 Phases Solid-State Relay S 10: 10 Amps 15: 15 Amps 25: 25 Amps 30: 30 Amps 40: 40 Amps 60: 60 Amps 80: 80 Amps A Output Type A: AC Output 10 40 TP Switch Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On D Output Voltage 40: 40-530 Vrms R Control Type A: 90-280 VAC D: 3-32 VDC OUTPUT SPECIFICATIONS (1) Description 10A 15A 25A 30A 40A 60A 80A Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] Maximum Load Current Per Phase(2) [Arms] Minimum Load Current Per Phase [Arms] Maximum 1 Cycle Surge Current (50/60Hz) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vrms] Thermal Resistance Junction to Case (Rjc) [°C/W] Maximum 1/2 Cycle I²t for Fusing (50/60 Hz) [A²sec] Minimum Power Factor (with Maximum Load) Weight (typical) [Gram] 40-530 1200 3 300 10 0.1 152/160 1.15 1.89 142/129 0.5 232 40-530 1200 3 300 15 0.1 229/240 1.15 1.73 172/171 0.5 232 40-530 1200 3 300 25 0.1 391/410 1.15 1.12 285/259 0.5 232 40-530 1200 3 500 30 0.1 477/500 1.15 0.88 1327/1221 0.5 232 40-530 1200 3 500 40 0.1 573/600 1.15 0.62 1770/1629 0.5 232 40-530 1200 3 500 60 0.15 764/800 1.15 0.57 2442/2247 0.5 398 40-530 1200 3 500 80 0.15 955/1000 1.15 0.49 3230/2971 0.5 415 Solid State Relay INPUT SPECIFICATIONS (1) Description Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Minimum Turn-Off Voltage Minimum Input Current [mA] Maximum Input Current [mA] Nominal Input Impedance Maximum Turn-On Time(3) [msec] Maximum Turn-Off Time [msec] SATP40xxA SATP40xxB SATP40xxD 90-280 Vrms 90 Vrms 10 Vrms 5 15 Current Regulated 20 30 40-140 Vrms 90 Vrms 10 Vrms 5 15 Current Regulated 20 30 3-32 VDC -32 3.0 VDC 1.0 VDC 7 20 Current Regulated 1/2 cycle 1/2 cycle GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) Minimum Insulation Resistance (@ 500 V DC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range Ambient Storage Temperature Range Housing Material Terminal Material Baseplate Material Humidity LED Input Status Indicator 4000 Vrms 109 Ohm 8 pF -40 to 80°C -40 to 125 °C UL E211125: 94 V-0 Gilded Copper 85% non-condensing Red RECOMMENDED MODEL & HEATSINK Choosing compatible current is critical in selecting a right model of solid state relay. Our engineers recommend SSR models according to actual applications and internal components of relay. For example, when solid state relay is used for electric heating, because of the cold resistance effect (the resistance value is 60% of heating wire value when it is in cold state), the SSR’s current should be 1.67 times bigger than actual working current in order to prevent the over-current of solid state relay. The recommendations for the other types of application are provided in the similar reasons. Heatsink in the table are compatible (size and thermal parameters) with the corresponding SSRs. Application to Electric Heating Continuous Load Current Per Phase Recommended Model(4) Recommended Panel Mount Heatsink 0.15A-6.4A SATP4010D G120 0.15A-9.9A SATP4015D G120 0.15A-17.6A SATP4025D T110 0.15A-21.7A SATP4030D T110 0.15A-26.2A SATP4040D FT110 Application to Three-Phase Motor Continuous Load Current Per Phase Recommended Model(4) Recommended Panel Mount Heatsink 0.15A-1.8A 0.15A-2.7A 0.15A-4.6A 0.15A-5.6A 0.15A-7A 0.15A-9A 0.15A-11.5A SATP4010D-R SATP4015D-R SATP4025D-R SATP4030D-R SATP4040D-R SATP4060D-R SATP4080D-R S150 S150 S150 G120 G120 G120 T110 GENERAL NOTES (1) (2) (3) (4) All parameters at 25°C and per section unless otherwise specified. Heat sinking required, for derating curves see next page. Turn-on time for random turn-on (-R) version is 0.1 msec. It is DC control as a default in the recommendation table, but it can be changed to AC control according to demand. AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314