Preview only show first 10 pages with watermark. For full document please download

S C P

   EMBED


Share

Transcript

SMARTCOM 3 CONTROL PANEL & WARM AIR WIRING INTERCONNECTS. Warnings All external wiring MUST comply with the current IEE wiring regulations. These instruction MUST be used in conjunction with the SmartCom user manual and the appropriate heater manual. Visit our Support Database at www.s-i-d.co.uk Part No. 704005 Nortek Global HVAC (UK) Limited, Fens Pool Avenue, Brierley Hill, West Midlands, DY5 1QA INDEX Diagram Number(s) Heater type Single Stage Two Stage Modulation 1 2 3 4 5 6 SDH SHH 7 8 9 OUHA 10 11 - ULSA - - 18 12 13 14 15 16 17 UESA (all versions) UDSA-3* (025-100) *from Jan14 UDSA-4** (055-085) **from Sept 15 VRA-3*** (12-145) ***after s/no.154501956 UDSA UDSA-2 UDSA-3 (008-020) UDSA-3* (025-100) *prior to Jan14 VRA-3** (12-145) **prior to s/no.154501956 UPA LCSA ST-2 series UC series c/w Autospark ignition UC series c/w Thermoelectric (P/Pilot) 1 Single Stage (on/off) Heaters with BMBC Autospark ignition to remote SmartCom³ SZ. FUSE RATING ! SmartCom Singlezone NEUT *IMPORTANT* REMOVE JUMPER LIVE 41 40 9 C 5 6 1/L 2/N 10 B1 B0 B2 S/R0S/R1 (COMMON) (REMOTE ON) (LOCKOUT INDICATION) (NEUTRAL) (LIVE) (HEAT 1 OUTPUT) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). (LOCKOUT RESET) (VENT 1 OUTPUT) NOTES: (LOCKOUT COMMON) *IMPORTANT* Add these link wires (REMOTE OFF) ! ! Room Sensor (where applicable) *The power supply is non-isolated, therefore all wiring to the control must be mains rated. eg B.M.S. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg Door Remote ON Remote OFF (where applicable) (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. *The power supply is non-isolated, therefore all wiring to the control must be mains rated. E 230Vac N MAINS IN L C 9 8 7 6 5 4 2 J1 Remove jumper 1 N L Non-interrupted mains supply must be present at the heater 230V 1Ph. BMBC style Heater Installer connection terminal strip 2 Two Stage (hi/low) Heaters with BMBC Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* REMOVE JUMPER 8 C 9 25 14 5 LIVE 6 1/L 2/N 10 (LOCKOUT INDICATION) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires (HEAT 1 OUTPUT) (LOCKOUT RESET) (LOCKOUT COMMON) *(HEAT 2 OUTPUT) *(HEAT 2 INPUT) (VENT 1 OUTPUT) S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! NEUT (COMMON) 7 (REMOTE OFF) 40 (REMOTE ON) 41 Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON Networking (where applicable) (where applicable) (* where applicable) NOTES: eg Door Remote OFF Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) (where applicable) E 230Vac N MAINS IN L C 9 8 7 6 J3 Remove jumper if fitted 5 4 2 J1 Remove jumper 1 N L Non-interrupted mains supply must be present at the heater 230V 1Ph. BMBC style Heater Installer connection terminal strip NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 3 Modulation Heaters with BMBC Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* REMOVE JUMPER 9 25 14 5 LIVE 6 1/L 2/N 10 (LOCKOUT INDICATION) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires (ENABLE/option C.R.F.) (LOCKOUT RESET) (LOCKOUT COMMON) (VENT 1 OUTPUT) S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! NEUT (COMMON) C (0 - 10Vdc output) 8 (COMMON) 7 (REMOTE OFF) 40 (REMOTE ON) 41 GM44 Interface board 64 66 OPTION Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON (where applicable) eg Door Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) Remote OFF (where applicable) E 230Vac N MAINS IN L C 9 8 7 6 3 4 2 J1 Remove jumper 1 N L Non-interrupted mains supply must be present at the heater 230V 1Ph. BMBC style Heater Installer connection terminal strip Networking (where applicable) NOTES: MODULATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 4 Single Stage (on/off) Heaters with Autospark ignition to remote SmartCom³ SZ. FUSE RATING ! SmartCom Singlezone NEUT *IMPORTANT* 'Plug in' jumper MUST be in Neutral position LIVE 41 40 9 C 5 6 10 B1 B0 B2 S/R0S/R1 (COMMON) (REMOTE OFF) (REMOTE ON) (LIVE) (LOCKOUT INDICATION) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). (HEAT 1 OUTPUT) Controls cables min 0.75mm² cable for up to a distance of 200m. (ENABLE/option C.R.F.) (LOCKOUT RESET) (VENT 1 OUTPUT) *IMPORTANT* Add this link wire (NEUTRAL) ! ! NOTES: 1/L 2/N Room Sensor (where applicable) eg Door Remote OFF *The power supply is non-isolated, therefore all wiring to the control must be mains rated. (where applicable) REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Remote ON (where applicable) E 230Vac N MAINS IN L *The power supply is non-isolated, therefore all wiring to the control must be mains rated. 10 9 8 7 6 5 4 2 J1 Remove jumper 1 N L Non-interrupted mains supply must be present at the heater 230V 1Ph. Heater Installer connection terminal strip 5 Two Stage (hi/low) Heaters with Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* 'Plug in' jumper MUST be in Neutral position 7 8 C 9 25 14 5 LIVE 6 1/L 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! (LOCKOUT INDICATION) (REMOTE ON) (LIVE) (NEUTRAL) *IMPORTANT* Add these link wires (HEAT 1 OUTPUT) (ENABLE/option C.R.F.) (LOCKOUT RESET) *(HEAT 2 OUTPUT) *(HEAT 2 INPUT) (VENT 1 OUTPUT) NEUT (COMMON) 40 (REMOTE OFF) 41 Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON Networking (where applicable) (where applicable) (* where applicable) NOTES: eg Door Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) Remote OFF (where applicable) MAINS IN 25 13 12 11 10 9 8 7 6 J3 Remove jumper if fitted 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) Heater Installer connection terminal strip NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 6 Modulation Heaters with Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* 'Plug in' jumper MUST be in Neutral position C 9 25 14 5 LIVE 6 1/L 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! (REMOTE ON) (LOCKOUT INDICATION) (LIVE) (NEUTRAL) *IMPORTANT* Add these link wires (ENABLE/option C.R.F.) (LOCKOUT RESET) (VENT 1 OUTPUT) NEUT (COMMON) 8 (0 - 10Vdc output) 7 (COMMON) 40 (REMOTE OFF) 41 GM44 Interface board 64 66 OPTION Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) MAINS IN 10 9 8 7 6 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) Heater Installer connection terminal strip Networking (where applicable) NOTES: MODULATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 7 Single Stage (on/off) SDH/SHH Heaters, Autospark ignition to remote SmartCom³ SZ. FUSE RATING ! SmartCom Singlezone NEUT *IMPORTANT* 'Plug in' jumper MUST be in Neutral position LIVE 41 40 9 C 5 6 10 B1 B0 B2 S/R0S/R1 (COMMON) (REMOTE OFF) (REMOTE ON) (NEUTRAL) (LOCKOUT INDICATION) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). (HEAT 1 OUTPUT) Controls cables min 0.75mm² cable for up to a distance of 200m. (ENABLE/option C.R.F.) (LOCKOUT RESET) (VENT 1 OUTPUT) *IMPORTANT* Add this link wire (LIVE) ! ! NOTES: 1/L 2/N Room Sensor (where applicable) eg Door Remote OFF *The power supply is non-isolated, therefore all wiring to the control must be mains rated. (where applicable) REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Remote ON (where applicable) *The power supply is non-isolated, therefore all wiring to the control must be mains rated. 25 13 12 11 10 9 MAINS IN 8 7 6 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) Heater Installer connection terminal strip 8 Two Stage (hi/low) SDH/SHH Heaters, Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* 'Plug in' jumper MUST be in Neutral position 7 8 C 9 25 14 5 LIVE 6 1/L 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! (REMOTE ON) (LOCKOUT INDICATION) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires (HEAT 1 OUTPUT) (ENABLE/option C.R.F.) (option DAMPER) (LOCKOUT RESET) *(HEAT 2 INPUT) *(HEAT 2 OUTPUT) (VENT 1 OUTPUT) NEUT (COMMON) 40 (REMOTE OFF) 41 Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON Networking (where applicable) (where applicable) (* where applicable) NOTES: Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) MAINS IN 25 13 12 11 10 9 8 7 6 J3 Remove jumper if fitted 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) Heater Installer connection terminal strip NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 9 Modulation SDH/SHH Heaters, Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* 'Plug in' jumper MUST be in Neutral position C 9 25 14 5 LIVE 6 1/L 2/N 10 S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! (REMOTE ON) (LOCKOUT INDICATION) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires (ENABLE/option C.R.F.) (option DAMPER) (LOCKOUT RESET) (VENT 1 OUTPUT) NEUT (COMMON) 8 (0 - 10Vdc output) 7 (COMMON) 40 (REMOTE OFF) 41 GM44 Interface board 64 66 OPTION Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON (* where applicable) (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) MAINS IN 25 13 12 11 10 9 8 7 6 3 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) Heater Installer connection terminal strip Networking (where applicable) NOTES: MODULATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 10 Single Stage (on/off) OUHA Heaters with Autospark to remote SmartCom³ SZ. FUSE RATING ! SmartCom Singlezone NEUT LIVE 41 40 9 C 5 6 ! 1/L 2/N 10 B1 B0 B2 S/R0S/R1 (COMMON) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). (REMOTE OFF) (REMOTE ON) Controls cables min 0.75mm² cable for up to a distance of 200m. (NEUTRAL) NOTES: (LIVE) (VENT 1 OUTPUT) *IMPORTANT* Add this link wire (HEAT 1 OUTPUT) ! Room Sensor (where applicable) eg Door Remote OFF (where applicable) *The power supply is non-isolated, therefore all wiring to the control must be mains rated. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Remote ON (where applicable) E N L *The power supply is non-isolated, therefore all wiring to the control must be mains rated. 12 11 10 9 8 7 6 5 4 E3 N2 L1 Non-interrupted mains supply must be present at the heater 230V 1Ph Heater Installer connection terminal strip 11 Two Stage (hi/low) OUHA Heaters with Autospark Ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING 8 C 9 25 14 5 6 LIVE 1/L 2/N S/R0 S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (LIVE) (NEUTRAL) (HEAT 1 OUTPUT) *(HEAT 2 OUTPUT) *(HEAT 2 INPUT) (VENT 1 OUTPUT) *IMPORTANT* Add this link wire 10 ! NEUT (COMMON) 7 (REMOTE OFF) 40 (REMOTE ON) 41 Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON (* where applicable) Networking (where applicable) (where applicable) NOTES: Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) E N L 12 11 10 9 8 7 6 5 4 E3 N2 L1 Non-interrupted mains supply must be present at the heater 230V 1Ph Heater Installer connection terminal strip NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 12 Single Stage (on/off) ST Heaters with Autospark to remote SmartCom³ SZ. FUSE RATING ! SmartCom Singlezone NEUT *IMPORTANT* 'Plug in' jumper MUST be in Neutral position LIVE 41 40 9 C 5 6 B1 B0 B2 S/R0S/R1 (COMMON) (REMOTE OFF) (REMOTE ON) INDICATION) (NEUTRAL) (LOCKOUT REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). (LIVE) (LOCKOUT RESET) Controls cables min 0.75mm² cable for up to a distance of 200m. (ENABLE/F.R.I./option C.R.F.) *IMPORTANT* Add this link wire (VENT 1 OUTPUT) NOTES: 10 ! (HEAT 1 OUTPUT) ! 1/L 2/N Room Sensor (where applicable) eg Door *The power supply is non-isolated, therefore all wiring to the control must be mains rated. Remote OFF (where applicable) REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Remote ON (where applicable) MAINS IN *The power supply is non-isolated, therefore all wiring to the control must be mains rated. 25 13 12 11 10 9 8 7 6 5 J6 A 25 13 12 11 10 9 J' 8 7 6 2 1 5 4 2 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) J1 Remove jumper Heater Installer Hot surface connection terminal strip B 4 1 Option Fast Response Ignition additional links required 13 Two Stage (hi/low) ST Heaters with Autospark Ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* 'Plug in' jumper MUST be in Neutral position 8 C 9 25 14 5 LIVE 6 1/L 2/N 10 (LOCKOUT INDICATION) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires (HEAT 1 OUTPUT) (ENABLE/F.R.I./option C.R.F.) (option DAMPER) (LOCKOUT RESET) *(HEAT 2 INPUT) *(HEAT 2 OUTPUT) (VENT 1 OUTPUT) S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! NEUT (COMMON) 7 (REMOTE OFF) 40 (REMOTE ON) 41 Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON Networking (where applicable) (where applicable) (* where applicable) NOTES: Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) MAINS IN 25 13 12 11 10 9 Heater Installer connection terminal strip B J6 8 7 6 5 J3 Remove jumper if fitted A 25 13 12 11 10 9 8 7 6 4 2 1 4 2 L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) J1 Remove jumper 5 N 1 Option Fast Response Ignition additional links required NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 14 Modulation ST Heaters with Autospark ignition to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING *IMPORTANT* 'Plug in' jumper MUST be in Neutral position 9 25 14 5 LIVE 6 1/L 2/N 10 (LOCKOUT INDICATION) (NEUTRAL) (LIVE) *IMPORTANT* Add this link wire (ENABLE/F.R.I./option C.R.F.) *(option DAMPER) (LOCKOUT RESET) (VENT 1 OUTPUT) S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! NEUT (COMMON) C (0 - 10Vdc output) 8 (COMMON) 7 (REMOTE OFF) 40 (REMOTE ON) 41 GM44 Interface board 64 66 OPTION Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON (where applicable) (* where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) MAINS IN 25 13 12 11 10 9 8 7 6 5 J6 A 25 13 12 11 10 9 8 7 2 1 6 5 4 2 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram) J1 Remove jumper Heater Installer connection terminal strip B 4 1 Option Fast Response Ignition additional links required Networking (where applicable) NOTES: MODULATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 15 Single Stage (on/off) Heaters with Thermoelectric (permanent pilot) to remote SmartCom³ SZ. FUSE RATING ! SmartCom Singlezone NEUT LIVE 41 40 9 C 5 6 10 B1 B0 B2 S/R0S/R1 (COMMON) (NEUTRAL) (LIVE) (REMOTE ON) REMOTE SWITCH INPUTS should be connected by 6A mains Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). (HEAT 1 OUTPUT) Controls cables min 0.75mm² cable for up to a distance of 200m. (option C.R.F.) (VENT 1 OUTPUT) *IMPORTANT* Add this link wire (REMOTE OFF) ! ! NOTES: 1/L 2/N Room Sensor (where applicable) eg Door Remote OFF *The power supply is non-isolated, therefore all wiring to the control must be mains rated. (where applicable) REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 6A mains* cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. eg B.M.S. Remote ON (where applicable) MAINS IN *The power supply is non-isolated, therefore all wiring to the control must be mains rated. 25 12 11 10 9 J3 8 7 6 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph or 415V 3Ph refer to heater wiring diagram). Heater Installer connection terminal strip 16 Two Stage (hi/low) Heaters with Thermoelectric (permanent pilot) to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING 7 8 C 9 25 14 5 LIVE 6 1/L 2/N S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (REMOTE ON) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires *(option C.R.F.) (HEAT 1 OUTPUT) *(HEAT 2 INPUT) *(HEAT 2 OUTPUT) (VENT 1 OUTPUT) 10 ! NEUT (COMMON) 40 (REMOTE OFF) 41 Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON Networking (where applicable) (where applicable) (* where applicable) NOTES: eg Door Remote OFF Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) (where applicable) MAINS IN 25 12 11 10 9 J3 8 7 J4 Remove jumper 6 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram). Heater Installer connection terminal strip NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 17 Modulation Heaters with Thermoelectric (permanent pilot) to remote SmartCom³ MZ (or Network). SmartCom Mulitizone ! FUSE RATING C 9 25 14 5 LIVE 6 1/L 2/N S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 (REMOTE ON) (NEUTRAL) (LIVE) *IMPORTANT* Add these link wires (ENABLE/option C.R.F.) *(option DAMPER) (VENT 1 OUTPUT) 10 ! NEUT (COMMON) 8 (0 - 10Vdc output) 7 (COMMON) 40 (REMOTE OFF) 41 GM44 Interface board 64 66 OPTION Room Sensor (where applicable) To other Slave Units C2 C0 C1 66 64 OPTION eg B.M.S. Remote ON Networking (where applicable) (where applicable) NOTES: (* where applicable) eg Door Remote OFF (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) MAINS IN 25 12 11 10 9 J3 8 7 J4 Remove jumper 6 5 4 2 J1 Remove jumper 1 N L N L1 L2 L3 Non-interrupted mains supply must be present at the heater (either 230V 1Ph / 415V 3Ph refer to heater wiring diagram). Heater Installer connection terminal strip MODULATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. NETWORK OPTION: if applicable Master-slave (Network) communication is by screened twisted pair cable, RS485 compatible such as Belden 9841. Maximum overall system length of 500m. Connect screen to C0. NOTE: Diagram shows a master and ONE slave configuration**. Wire further slaves in parallel. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. remote frost etc). For Master/Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. 18 Modulation ULSA Heaters with Autospark ignition to remote SmartCom³ MZ. SmartCom Mulitizone ! FUSE RATING *IMPORTANT* REMOVE JUMPER 25 14 5 LIVE 6 1/L 2/N 10 NOTES: (LOCKOUT INDICATION) (LIVE) (NEUTRAL) (L/O RESET) (L/O COMMON) (VENT 1 OUTPUT) *IMPORTANT* Add this link wire MODULATION 0-10V outputs should be connected by 0.75mm² cable. Max length is 100m. REMOTE SWITCH INPUTS should be connected by 0.75mm² cable. Max length is 100m. Low voltage switching inputs to be normally open (closed circuit to enable). Connect to B0 & B1 for remote ON (ie BMS time control). Connect to B0 & B2 for remote OFF (ie door interlock. frost etc). For Master / Slave networks, remote OFF can be set for individual zones or total system via the Master. REMOTE SENSOR(s) may be placed at a max distance of 100m from the control unit, using screened 0.75mm² cable. Wiring should be kept separate from mains wiring to minimise noise pick up. Set within Engineers functions for remote sensor. S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 ! NEUT Room Sensor (where applicable) eg B.M.S. Remote ON (where applicable) Controls cables min 0.75mm² cable for up to a distance of 200m. - - - - Optional features where requested (refer to heater wiring diagram.) eg Door Remote OFF (where applicable) E 230Vac N MAINS IN L 66 64 C 10 9 8 7 6 5 4 2 J1 Remove jumper 1 N L Non-interrupted mains supply must be present at the heater 230V 1Ph. CS0254C style Heater Installer connection terminal strip Nortek Global HVAC (UK) Ltd Fens Pool Avenue Brierley Hill West Midlands DY5 1QA United Kingdom Document reference number GB/SCOM/121/0915 Replaces GB/SCOM/121/1114 9 (COMMON) C (0 - 10Vdc output) 8 (REMOTE OFF) 7 (REMOTE ON) 40 (COMMON) 41 Tel: 01384 489250 Fax: 01384 489707 [email protected] www.ambirad.co.uk Registered in England No. 1390934. Registered office: 10 Norwich Street, London, EC4A 1BD Nortek Global HVAC is a registered trademark of Nortek Global HVAC Limited. Because of continuous product innovation, Nortek Global HVAC reserves the right to change product specification without due notice.