Preview only show first 10 pages with watermark. For full document please download

S M F -

   EMBED


Share

Transcript

ZoomStereo Microscope Operation Manual SMF-806/808/810 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3, Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 [email protected] MRC.VER.01-3.14 Contents Maintenance Structure Assemblage Operation Assemblage and Usage of the Illumination Other Attachments Main Technology Parameter Troubleshooting Thanks for choosing choosingRXU Stereo Microscope This instruction is for S0) Series Zoom Stereo Microscope Please read the instruction carefully before using � Proper modification can be made without notice � Please contact manufacturer if something unclear or incorrect is found � The product you purchase may not include all the things mentioned in the manual � Please operate the instrument as the instruction Safety problems have been fully considered when design, users may get hurt or instrument can get damaged if improper operations are taken. For your safety, please read the instructions carefully before using. Warning 1. Specified use The instrument can be used for micro observation only 2. Do not take the microscope apart As it will be damaged. Please contact manufacturer if the microscope does not work 3. Make sure the input voltage The correct input voltage is marked on the power supply of the illumination. Make sure the voltage in your position is right. Improper input voltage may cause short circuit and fire. Please contact manufacturer if you have any questions 4. Power supply cord Please turn off the power supply and pull out the cord when replacing the bulbs 5. Temperature for illumination The temperature will be high if the bulb is lightened. Do not put fiber, papers and inflammable things (eg. Gasoline, aether, methanol and ethanol) close to the bulb Attention 1. Be careful when replacing the bulbs The bulb ( halogen bulb) will be heated after using. Replace the bulb when it has been cooling enough to avoid scald. 2. Check the illumination Specific bulbs can be used. Bulbs with different specifications may cause damage to the instrument. Refer to the manual for more information Maintenance 1. Working Environment � Temperature range is 0°C-40 C-40°°C and the max. Humidity is 85%. Avoid high temperature and humidification. � Do not expose the microscope in the sun directly � Place microscope on a stable plane and keep it in balance. Avoid violent vibration � Keep the environment breezy and cover the microscope with the dust-cover. 2. Protect the microscope well As microscope is a precision instrument, please avoid violent vibration. Improper using will make it unworkable. 3. Lens cleaning Avoid dust and fingerprint on the lens as these will reduce its precision. Please clean as the following 1) Blow the dust with soot blower. Soft brush or gauze can also be used to remove the dust 2) More persistent dirt, such as fingerprints and oil, may be removed with soft cotton or lens tissue lightly moistened with absolute alcohol. As absolute alcohol are quite flammable, please take great care when using. 4. Cleaning of the painted or plastic parts Avoid using organic solvents ( such as alcohol, ether, etc) to clean the painted or plastic parts of the instrument. We recommend the use of gauze. More persistent dirt may be cleaned with mild detergent solution 5. Storage When the microscope is not in use, cover it up with dust cover, and store in a dry place not subject to mold. Do not expose the microscope in the sun directly, avoid high temperature and humidification 6. Periodical inspection To maintain the performance of the microscope, periodical inspection is recommended. Structure As s e mbl ageofSMF800Se r i e s Loosen the arm fixing screw with the wrench (big) attached with the stand. Assemble the arm over again using the screw at the high position on the slider. There are 55mm discrepancy between low & high position. Before tightening the screw, make sure that the 2 pins on the arm fit into the grooves on the vertical slider. 4. Mount the zoom body Gently tighten the zoom body clamp screw to hold the zoom body into the focus arm Note: Do not over-tighten the zoom body clamp screw as this may cause damage to the instrument 5. Mount the objective Insert the objective into the zoom body 6. Mount the eyepiece tube Insert the eyepiece tube into the zoom body, and tighten the screw with the wrench (small) attached with the stand 7. Mount the eyepiece Insert the eyepiece into the eyepiece tube while diopter scale at 0. Be sure that it is inserted till it touches the end of the sleeve. Operation 1. Preparation 1) Adjust the torque of focus knob Adjust the torque of the focus knob so that the zoom body will not fall down because of its own weight. 2) Illumination Insert the plug into the plug base, and turn on the power supply. Adjust the brightness of the illumination to get a suitable illumination. 3) Adjusting a. Check the working distance Set the distance between the bottom of the zoom body and specimen at a suitable position (as long as the working distance) b. Focus on the specimen Adjust the focusing knob to make the focus on the specimen. 4) Interpupillary distance adjusting This adjustment should be performed every time if the observer changes since the interpuillary distance is different between individuals. Adjust the interpupillary distance so that the view field for each eye is merged into one. Move while holding each tube with both hands. 5) Diopter adjusting a. Set the zooming knob to the highest magnification, focus on the sample using the focus knob b. Set the zooming knob to the lowest magnification, look into the left eyepiece with your left eye, focus on the sample using the diopter ring on the left eyepiece. Then look into the right eyepiece with your right eye, and focus on the sample using the diopter ring on the right eyepiece. 2. Magnification Turn the zoom knob to change the magnification of the sample 1) Total magnification Total magnification= Eyepiece's magnification × Zoom magnification Note: When attachments such as upright illumination is attached, multiply 1.5 as well. 2) ON/OFF of the locating reading unit of the zoom knob a. Plug the wrench(small) into the hole behind the zoom tube, loosen the inner screw, and this operation can help to cancel the automatic setting of the locating reading ( OFF). On the contrary, tighten the inner screw toward the opposite direction can restore this setting ( ON ) Assemblage and usage of the illumination 1. Illumination Many kinds of power supply can be attached, such as transmitted, sideling, circuit LED, upright illumination and etc. Power supply setting Input Voltage Output Voltage Power cord Working Environment Protective Level 200V-240V 50/60Hz 0.4A 6V20W Max Incorrect power cord may cause fire Equipment of protective Level I must connect PE 250V 7A Temperature: 0-40 0-40°°C (Only indoor) Humidity: <85% ( No dew) Pollution: Level 2 Assemblage: Classified 2 Level 1 2. Assemblage of the illumination a. Assemblage of the sideling illumination Fix the extra-long board on the body with screw 1, put the sideling illumination well with the screw hole on the extra-long board, and tighten it. Adjust the lamp house for better observation, and then tighten the screw 2. b. Circuit LED Plug the screw of the circuit LED into the groove of the zoom tube, and tighten it. Plug the power cord into the base of the column top c. 1) 2) 3) Assemblage of the upright illumination Push the groove of the upright illumination into the joggle, and tighten it. 1/4λλ into the bottom of the main objective Fix the 1/4 Plug the incidence face of the fiber into the fiber connector of the illumination, tighten the screw. Plug the irradiance port into the fiber connector of the upright illumination, and tighten the screw. 4) Revolve the 1/4 1/4λλ to obtain the suitable brightness and contrast. 5) Plug the filter into the fiber illumination to change the balance of the colour during the process of the micro-image. 3. Assemblage of the movable hinge Loosen the knob slightly and turn the pipe.` Plug the fixing screw of the movable hinge into the hole on the stand, and tighten the screw. Fix the screw into the hole in the lamp house. Adjust the direction of the lamp house for better observation. Note: a. The bulb has been mounted before shipment. Avoid scald after using. b. Replacement of the bulb. Turn off the power supply and cool the bulb enough before replacing the bulb. Do not touch the glass parts of the bulb directly. Clean the glass with cotton cloth slightly with absolute alcohol. c. Mounting of the filter The frosted glass has been assembled in the front of the sideling illumination. Change the filters by revolving the lamp house. Other Attachments 1. Photography and Video Attachments Assembly Assemble the optical splitter between zoom tube and eyepiece tube ( single or double) to take pictures or display the image on the monitor. 1) Total magnification Magnification (with video)= main objective magnification × zoom magnification × connector magnification When upright illumination is used Magnification= main objective magnification × zoom magnification × projection lens magnification ×1.5 2) Assemblage of the optical splitter Assemble the optical splitter on the zoom tube by connecting the groove of the optical splitter's bottom and fixing screw of the eyepiece tube, and tighten the screw with the wrench ( small) a. Assemblage of the single optical splitter b. Assemblage of the double optical splitter SMF806 SMF808 SMF810 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 25X Eyepiece 2X Plan Main Objective 0.5X Plan EPO Main Objective Circuit LED Movable Hinge Rotary Stage 10X Division Eyepiece Micrometer Trinocular Accessories Quadruple Reflected Stand ( LED/ Halogen Lamp) Transmitted ( LED ) Transmitted & Reflected Zoom Stand/ Stand ( LED/ Halogen Zoom Stand with Lamp) Fine Focusing Stand without Illumination Zoom Stand with Fine Focusing SE4200 Large Stand Polydirectional Stand Transmitted Stand ( Halogen ) Adjustable Binocular Eyepiece Tube BTS-V0351 Coaxial LED Illumination CIS-CL 0.02mm Range: 0~35 Troubleshooting Under certain conditions, performance of this unit may be adversely affected by factors other than defects. If a problem occurs, please review the following list and take immediate action as need. If you can not solve the problem after checking the entire list, please contact manufacturer. Problem Incomplete Binocular vision Dirt is visible in field of Cause Interpupillary distance is not correctly adjusted Diopter adjustment is incomplete Different magnification of the 2 eyepieces Dirt on specimen Solution Adjust it correctly Complete the diopter adjustment Exchange the eyepiece with same magnification Clean Specimen view Dirt on Eyepiece Clean Eyepiece Diopter ring is not Adjust it correctly Specimen image blurs adjusted correctly when zoom Incorrect focus on Focus specimen correctly magnification changes specimen Inflexible coarse focusing Tension adjustment is too Loosen it properly knob tight Zoom microscope body Tension adjustment is too Tighten it properly drops automatically loose