Preview only show first 10 pages with watermark. For full document please download

S - Vemco

   EMBED


Share

Transcript

DT EST & MEASUREMENT CLAMP METERS ...................................D-2 SPECIALITY TESTERS ..............................D-19 MULTIMETERS .......................................D-5 ACCESSORIES .......................................D-20 CIRCUIT TRACERS .................................D-9 REPLACEMENT PARTS ............................D-22 THERMAL IMAGERS ...............................D-10 CIRCUIT ANALYZERS .............................D-12 POWER QUALITY ...................................D-14 INSULATION/GROUND TESTERS ..............D-15 VOLTAGE TESTERS .................................D-16 ELECTRICAL TESTERS .............................D-17 TEST & MEASUREMENT Clamp Meter Selection Guide WWW.IDEALINDUSTRIES.COM s s s s s s s s s s s s s s s D 200 D 200 D 600 s s s s s s s s s 61-775 61-746 s s s s s 61-773 61-744 s s s 770 Series 61-765 61-704 s s s 760 Series 61-763 CLAMP METERS D-2 CLAMP METER SELECTION GUIDE MEASUREMENT FUNCTIONS AC Voltage DC Voltage AC Current DC Current Resistance Audible Continuity Diode Test Capacitance Frequency FEATURES Display Type (Digital) AC Current Capacity DC Current Capacity True RMS Auto Ranging Auto/Manual Ranging Data Hold Max Hold Peak Hold Min/Max DCA Zero Auto Power Off Non-Contact Voltage Indication Harmonics Indicator Vibration Mode Backlight Low Battery Indication High Voltage Warning Overload Protection on all Ranges Conductor Size – Inches (mm) Warranty (years) CERTIFICATIONS UL 61010 Listed CAT III, 100V/CAT IV 600V CE 740 Series 61-702 700 Series s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s D 600 D 660 s s D 660 660 s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 1.4” (36) 2 s s s s 2.0” (51) 2 s s s s 2.0” (51) 2 s IV s s IV s s IV s D D 1000 1000 1000 s s s s s s 1.3” (33) 2 s s s s s s s s 1.3” (33) 2 s III s s III s s s s s s s s 1.5” (38) 2 s 1.5” (38) 2 s s s s 1.4” (36) 2 s III s s III s s IV s 1-800-435-0705 CUSTOMER ASSISTANCE TightSight® Clamp Meters 1000 & 660 Amp s TightSight®BOTTOMDISPLAY s 4APEREDJAWSWITHHOOKTIP s -EASURES!#CURRENT s 4RUE2-3 s !#$#6OLTAGE s #APACITANCE s !UDIBLECONTINUITY s &REQUENCYVIACLAMPHEADORTESTLEADS s 2ESISTANCE s (IGHFREQUENCYREJECTION s 0EAKHOLD N12966 600V 1000V s -AXMINHOLD s $ATAHOLD 1000A Clamp (61-773) s 3ELECTABLEAUDIBLEANDVISUALVOLTAGE ALERTSON!#$#VOLTAGEFUNCTIONS s 3ELECTABLEAUTOPOWEROFF s "ACKLITDISPLAY s ,OWBATTERYINDICATOR s  YEARWARRANTY 660A Clamp (61-763) Exclusive TightSight ® Display Description Cat. No. 1000AAC Clamp Meter 61-773 1000A AC/DC Clamp Meter 61-775 660AAC Clamp Meter 61-763 660A AC/DC Clamp Meter 61-765 Includes: Carrying Case and Test Leads w/Alligator Clip. Specifications Range & Resolution 61-773 AC Current DC Current 61-775 61-763 0.0-999.9A — 61-765 0.0-660.0A 0.0999.9A — 0.0-660.0A Accuracy 2.0% 2.0% AC Voltage 0.0-750.0V 1.0% DC Voltage 0.0-999.9V 1.0% Resistance 0.0-999.91 1.5% Capacitance 0.0-999.9μF 5.0% Continuity 0.0-999.91 Audible @ <301 Frequency 20.0-400.0Hz 0.5% Jaw Size 1-800-435-0705 CUSTOMER ASSISTANCE CLAMP METERS 2EADSACCURATELYONNOISYELECTRICALCIRCUITS 2” (51mm) 1.42” (36mm) — WWW.IDEALINDUSTRIES.COM D-3 TEST & MEASUREMENT Clamp-Pro™ Clamp Meters 600 Amp (740 Series) s -EASURESUPTO!!# Compact jaw for use in tight locations. s .ON CONTACTVOLTAGEINDICATOR 6 6!# s #ONTINUITY 61-744 s 4APEREDJAWSWITHHOOKTIP s !UTOMANUALRANGING s $ATAHOLD s !UTOPOWEROFF s ,OWBATTERYINDICATOR s  YEARWARRANTY N12966 Description Cat. No. 600A Clamp Meter w/TRMS 61-746 600A Clamp Meter 61-744 600V Specifications Includes: Carrying Case and Test Leads. Range & Resolution Accuracy AC Current 40.00/400.0/600A 1.7% AC Voltage 400.0/600 V 1.2% DC Voltage 400.0/600 V 0.5% Resistance 400.0/4.000k/ 40.00k 400.0k/4.000M/40.00M 1 1.0% Jaw opening is 1.25” (32mm). CLAMP METERS 4-in-1 Test Tools (700 Series) s !!#CURRENTCAPABILITY s .ON CONTACTVOLTAGE 6!# s 6IBRATIONMODETOVERIFY!#VOLTAGE s (ARMONICSINDICATOR s #APACITANCE 61-704 s -AXHOLD s #ONTINUITY s ,OWBATTERYINDICATION s )NTEGRALLEADSTORAGE s !UDIBLEDANGEROUSVOLTAGEWARNINGON ALLRANGES N12966 1000V s !UTOPOWEROFF s %RGONOMICHOURGLASSSHAPE Specifications s #OMPACTCLAMPHEAD Range & Resolution s  YEARWARRANTY Description Cat. No. 4-in-1 Test Tool w/TRMS, Backlight 61-704 4-in-1 Test Tool 61-702 Includes: Carrying Case and Silicone Test Leads. D-4 WWW.IDEALINDUSTRIES.COM Accuracy AC Voltage 2000m/200.0/750 V 1.2% DC Voltage 2000m/200.0/1000 V 0.5% AC Current 200.0 A 3.0% Resistance 200.0/200.0k 1 1.0% Capacitance 200.0μ F 3.0% Jaw opening is 1.3” (33mm). 1-800-435-0705 CUSTOMER ASSISTANCE Multimeter Selection Guide s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s 61-614 s s s s 61-610 s s s s 61-605 s s s s s s s s s s s s s s s s s s s s s s s s s s s D s s D s s A s s s s s s s s s s s s s s s 2 s s s s s s IV s 610 Series 61-498 61-484 s s s s 600 61-497 61-361 s s s s 490 Series 61-486 61-342 480 Series 61-340 360 61-312 s s s s s s s s s s s s s s s s s s s s s s s s s A A s s 2 2 2 s II s s II s s II s s D D D D s s D s s D s D s s s D s s s D s s s D s s s D D s s D s s s s s s s s s s s s s s s s s s s s s s s s s 2 2 2 2 2 2 2 A s s s s s s s s s s s s s s s 2 s II s s II s s III s s III s s III s s IV s s IV s s IV s 1-800-435-0705 CUSTOMER ASSISTANCE D s D WWW.IDEALINDUSTRIES.COM MULTIMETERS MULTIMETER SELECTION GUIDE MEASUREMENT FUNCTIONS AC & DC Voltage AC Current DC Current Resistance LV Resistance Audible Continuity Diode Test Capacitance Frequency Temperature Duty Factor Battery Test Decibels Phase Rotation FEATURES Display Type (Digital or Analog) True RMS Auto/Manual Ranging Non-Contact Voltage Detection Data Hold / Auto Hold Min/Max Min/Max/Avg Peak Min/Max Relative Mode High Speed Analog Bar Graph Auto Power Off Backlight Low Battery Indication Dual Display Overload Protection on all Ranges Data Logging Data Acquisition Memory Storage & Recall Optical USB Interface ProVision™ II Software Warranty (years) CERTIFICATIONS UL 61010 Listed CAT Rating CE 340 Series 61-310 310 Series D-5 TEST & MEASUREMENT 490 Series Industrial-Grade Multimeters s 4RUE2-3 s D"MD"MEASUREMENT s $ATAACQUISITION DATALOGGINGDATA STORAGE s 2ELATIVEMODE s -IN-AX!VG s !UTO!#$#VOLTAGEANDCURRENTMODEW FREQUENCYINDICATION 61-498 s $UALDISPLAY s $UTYFACTOR s (IGHVOLTAGEINDICATOR s !UTOPOWEROFF s &REQUENCY s !UTOSENSINGBACKLIGHT s 4EMPERATURE s ,OWBATTERYINDICATOR s (IGHFREQUENCYREJECTIONMODE s !UTOSELECTIONFORRESISTANCECONTINUITY DIODECAPACITANCE N12966 s 53"CABLEANDSOFTWARE INCLUDED s  YEARWARRANTY s !UTOHOLD PEAKHOLD 600V 1000V 2EADSACCURATELYONNOISYELECTRICALCIRCUITS Specifications Description Cat. No. Digital Multimeter, 0.015% DCV Accuracy 61-498 Digital Multimeter, 0.03% DCV Accuracy 61-497 AC Voltage Accessories DC Voltage Includes MULTIMETERS Test Leads w/Alligator Clips TL-497 AC Current DC Current Magnetic Strap 61-565 Resistance USB Cable 61-902 ProVision™ II Software 61-906 K-Type Thermocouple 61-461 Thermocouple Adapter 61-465 Carrying Case C-230 Capacitance Diode Test Frequency Duty Factor Temperature Range & Resolution 61-497 61-498 40.000m/400.00m/ 100.000m/1000.00m/ 4.0000/40.000/400.00/1000.0 V 10.0000/100.000/1000.00V 40.000m/400.00m/ 100.000m/1000.00m/ 4.0000/40.000/400.00/1000.0 V 10.0000/100.000/1000.00V 40.000m/400.00m/10.000 A 10.0000m/100.000m/10.0000A 40.000m/400.00m/10.000 A 10.0000m/100.000m/10.0000A 400.00/4.0000k/40.000k/400.00k/ 1000.00/10.0000k/100.000k/1000.00k 4.0000M/40.000M 1 10.0000M/40.000M 1 4.000n/40.00n/400.0n/4.000μ/ 40.00μ/400.0μ/4.000m/40.00mF 2.000 V 0.400 V - 0.800 V 40.000/400.00/4.0000k/40.000k/400.00k/4.0000M Hz 20% - 80% -328° F to 2192° F (-200° C TO 1200° C) Accuracy 61-497 61-498 ±0.7% ±0.40% ±0.03% ±0.015% ±0.8% ±0.2% ±0.7% ±0.1% 0.6% 0.9% ±1.5% ±0.002% ±0.1% ±1.0% +2°F/1°C 480 Series Commercial-Grade Multimeters s 4RUE2-3 s !UTO!#$#VOLTAGE DETECTWLOWIMPEDANCE !UTO 6,O: s #APACITANCE 61-486 s &REQUENCY s !NALOGBARGRAPH s -INMAX s .ON CONTACTVOLTAGEDETECTION Specifications s ,OWBATTERYINDICATION s !UTOPOWEROFF s  YEARWARRANTY Description Cat. No. Digital Multimeter w/peak hold, temperature, includes thermocouple 61-486 Digital Multimeter 61-484 Include: Test Leads & Carrying Case. D-6 WWW.IDEALINDUSTRIES.COM AC Voltage AC mV DC Voltage DC mV AC Current DC Current Resistance Capacitance Frequency Temperature N12966 Range & Resolution 61-484 61-486 6.000/60.00/600.0/1000.0 V 600.0 mV 6.000/60.00/600.0/1000.0 V 600.0 mV 60.00/600.0 mV 60.00m/600.0m/6.000/10.00A 60.00m/600.0m/6.000/10.00A 600.0/6.000k/60.00k/600.0k/6.000M/40.00M 1 1nF to 10.mF 99.9 to 100.0k Hz -40°F to 752°F — (-40°C to 400°C) 600V 1000V Accuracy 61-484 61-486 1.0% 0.80% 1.5% 1.2% 0.1% 0.08% 1.5% 1.0% 1.0% 1.2% 0.80% 0.80% 0.1% 0.1% 1.0% 1-800-435-0705 CUSTOMER ASSISTANCE 361 Contractor-Grade Multimeter s 0HASEROTATION s #APACITANCE s &REQUENCY s 6OLTAGE s #URRENT s 2ESISTANCE s !UDIBLECONTINUITY s -ANUALRANGING s 2UGGEDCONSTRUCTION s !UTOPOWEROFF N12966 s ,OWBATTERYINDICATION 300V Specifications s  YEARWARRANTY Description Cat. No. 361 Multimeter w/TRMS 61-361 AC Voltage DC Voltage AC Current DC Current Resistance Capacitance Frequency Phase Rotation Includes: Test Leads. Range & Resolution Accuracy 200.0m/2000m/200.0/600 V 2.0% 200.0m/2000m/20.00/200.0/600 V 1.2% 2.000 A 3.0% 2.000 A 2.5% 200.0/2.000k/20.00k/200.0k/20.00M/200.0M 1 1.0% 20.00μ/200.0μ/2.000m/20.00m F 4.0% 10.0-100.0k Hz 0.5% 80-500V (50-500Hz) — 340 Series Test-Pro® Multimeters s "ACKLIGHT s &REQUENCY s -INMAX s 4EMPERATURE s $ATAHOLD s 6OLTAGE s ,OWBATTERY INDICATOR s #URRENT s 2ESISTANCE s !UDIBLECONTINUITY 61-342 s !UTOPOWEROFF MULTIMETERS s #APACITANCE 61-340 s  YEARWARRANTY s 2ELATIVEMODE Description Cat. No. ® 61-342 ® 61-340 Test-Pro Multimeter w/TRMS Test-Pro Multimeter N12966 300V Includes: Test Leads and Thermocouple. Specifications 1-800-435-0705 CUSTOMER ASSISTANCE Range & Resolution Accuracy AC Voltage DC Voltage Current Resistance Capacitance 4.000/40.00/400.0/600 V 400.0m/4.000/40.00/400.0/600 V 400.0μ/4000μ/40.00m/400.0m/4.000/10.00A AC/DC 400.0/4.000k/40.00k/400.0k/4.000M/40.00M 1 40.00n/400.0n/4.000μ/ 40.00μ/400.0μ F 1.5% 0.5% 1.5% 1.0% 3.0% Frequency Temperature 10.000/100.00/1.000k/10.00k/100.0k/1.000M/4.000M Hz -4° F to 1382° F (-20° C to 750° C) 0.3% 3.0% WWW.IDEALINDUSTRIES.COM D-7 TEST & MEASUREMENT 310 Series Residential Meters s 6OLTAGE s #URRENT s 2ESISTANCE s !UDIBLECONTINUITY 61-312 s 4EMPERATURE s $ATAHOLD 61-310 s $IODETEST s ,ARGENUMBERSDISPLAYED s  YEARWARRANTY Description Cat. No. Resi-Pro™ Meter w/Auto Ranging, AC/DC Current, Capacitance, Frequency, Auto Power Off, Low Battery Indication 61-312 Resi-Pro™ Meter w/Manual Ranging, Tests Batteries 61-310 N12966 300V Includes: Test Leads and Thermocouple. Specifications AC Voltage DC Voltage Current Resistance Capacitance Frequency Temperature 61-310 Range & Resolution Accuracy 200.0/300 V 1.2% 200.0m/2.000/20.00/200.0/300 V 0.5% 200.0m/10.00 ADC 1.5% 200.0/2.000k/20.00k/200.0k/20.00M 1 1.0% — — — — -4-1382°F (-20-750°C) 2.5% 61-312 Range & Resolution 4.000/40.00/400.0/300 V 400.0m/4.000/40.00/400.0/300 V 400.0μ/4000μ/40.00m/400.0m/10.00A AC/DC 400.0/4.000k/40.00k/400.0k/4.000M/40.00M 1 40.00n/400.0n/4.000μ/40.00μ/400.0μ F 10.00/100.0/1.000k/10.00k/100.0k/1.000M/10.00M Hz -4-1382°F (-20-750°C) Accuracy 1.2% 0.5% 1.5% 1.0% 3.0% 0.3% 2.5% MULTIMETERS Pocket Meter Analog Meters s #ONVENIENTPOCKETSIZE s -ULTI COLORANALOGDISPLAY WITHMIRROREDSCALE s "UILT INLEADSTORAGEAND TESTSTAND s !UDIBLECONTINUITY s (IGH IMPACT THERMOPLASTICCASE s !UTOPOWEROFF s "ATTERYTEST s 4ESTLEADSTORAGE s  YEARWARRANTY 61-614 s  YEARWARRANTY Description Cat. No. Pocket Meter 61-605 Includes: Test Leads. Cat. No. Analog Multimeter w/Audible Continuity, built-in stand 61-614 Analog Multimeter (pocket-size) 61-610 Includes: Test Leads. Specifications Specifications AC Voltage DC Voltage Resistance Description Range & Resolution 200.0m/2.000/20.00/200.0/600 V 200.0m/2.000/20.00/200.0/600 V 200.0/2.000k/20.00k/200.0k/2.000M/20.00M 1 N12966 Accuracy 4.0% 2.0% 3.0% 300V Range & Resolution Accuracy 61-610 61-614 AC Voltage 10/50/250/500 V 10/50/250/1000 V +/- 4.0% Full Scale DC Voltage 10/50/250/500 V 2.5/10/50/250/1000 V +/- 3.0% Full Scale DC Current 500μ/50m/250mA 5m/50m/500m/20A +/- 3.0% Full Scale 1 M 1 Full Scale 10k/100k/10M 1 Full Scale Resistance +/- 3.0% Arc Length 5 k 1 Mid Scale 50/500/50k 1 Mid Scale Decibels -20 to +56 dB -8 to +62 dB — Battery Test 1.5 , 9.0 VDC 1.5 , 9.0 VDC — N12966 D-8 WWW.IDEALINDUSTRIES.COM 600V 1-800-435-0705 CUSTOMER ASSISTANCE SureTrace™ s Circuit Tracers s 2ECEIVERDISPLAYROTATESAUTOMATICALLY TICALLY FOREASYVIEWING s )DENTIFIESBREAKERSANDFUSESWITH #ERTAIN#IRCUIT»DETECTION s 0INPOINTSOPENSANDSHORTS s 4RACESWIRES s h vDISPLAYOFSIGNALSTRENGTH s !UDIBLEINTENSIFIESINTONEPITCH s 7ORKSONENERGIZEDOR DE ENERGIZEDCIRCUITS  6!#$# 61-959 s &OURMODESOFSENSITIVITY 61-957 s 0EAKBARGRAPH s  YEARWARRANTY Description Cat. No. Receiver with Rotating Display, Inductive Clamp and Battery Pack 61-959 Receiver with Rotating Display 61-957 Receiver with Standard Display 61-955 CIRCUIT TRACERS 61-955 CertainCircuit ™ After you identify and trip the correct breaker, the transmitter senses the loss of power and sends a different signal back to the receiver to give you confidence at the panel that the right circuit was de-energized. Energized Exclusive Rotating Display Revolutionary technology in the receiver rotates the display in 90° increments so that you always receive an upright reading. Even when the receiver is pointing down, you can keep up. De-energized Transmitter will work on a de-energized circuit and won’t affect GFCIs N12966 AA batteries provide the transmitter and receiver 4x the power. 600V 1-800-435-0705 CUSTOMER ASSISTANCE WWW.IDEALINDUSTRIES.COM D-9 TEST & MEASUREMENT ® Thermal Imagers s "LENDEDTHERMALDIGITALIMAGE 0)0 Description Cat. No. ® s (OTTESTCOLDESTTEMPERATURECURSORSINSTANTLYDISPLAY ONLIVESCREEN HeatSeeker 320 Thermal Imager – (320 x 240 resolution) 61-848 s 3EQUENCEIMAGERECORDINGACTIVATEDBYALARM SETTINGS HeatSeeker® 160 Thermal Imager – (160 x 120 resolution) 61-846 s #LASS))LASER HeatSeeker® Thermal Imager – (47 x 47 resolution) 61-844 s "UILT IN,%$LIGHT s (IGHANDLOW TEMPERATUREALARMS s 3AVEIMAGESWITHTEXT ANDVOICEANNOTATION 61-848/ 61-846 Accessories Includes s !DJUSTABLEEMISSIVITYFOR MAXIMUMACCURACY s )0RATED Removable Battery 61-846BAT — USB Cable 61-844USB 61-844USB Camera Handle — 61-844HAN s -ULTI LINGUAL NINE LANGUAGESINCLUDED Carrying Case 61-844CC 61-844CC Power Supply 61-846PS 61-844PS s 4RIPODMOUNTABLE ThermalVision™ Software 61-848SW 61-844SW s 4HERMAL6ISION»0# SOFTWAREINCLUDED Optional s 4WO YEARWARRANTY THERMAL IMAGERS Specifications Feature N12966 Included Accessories: Temperature Range Light Shade 61-844LS 61-844LS Car Charger 61-846CAR 61-844CAR Desktop Charger 61-846DT — Hard Transport Case 61-846HC 61-846HC HeatSeeker® (61-844) HeatSeeker® 160 (61-846) HeatSeeker® 320 (61-848) 14°F to 662°F (-10°C to 350°C) -4°F to 1652°F (-20°C to 900°C) 14°F to 482°F (-10°C to 250°C) Temperature Accuracy ±2°C or ±2% of reading Emissivity Table Cursors 0.2 to 1.0 (adjustable) Four-movable (with independent emissivity setting) Two-movable Image Storage (2 GB micro SD card) Field of View 2000 Images 20° x 20° 10° x 15° < 0.3°C at 30°C < 0.08°C at 30°C Focal Plane Array 47 x 47 (2,209 pixels) 160 x 120 (19,200 pixels) 320 x 240 (76,800 Pixels) Visible Light Camera Resolution Spectral Range Image Control 3.5” LCD 1.0 Megapixels 2.0 Megapixels 8μm to 12μm 8μm to 14μm Eight color palettes (Ironbow, Rainbow, Isotherm, Hot Metal, High Contrast, Rainbow 16, Black Hot and White Hot) Focus Battery Life 61-846 / 61-848 Power Pump Motor WWW.IDEALINDUSTRIES.COM 21.4° x 16° Thermal Sensitivity Display D-10 61-844 Manual 6 hours 6 hours Internal rechargeable Li-ion battery 4 hours Field replaceable, rechargeable Li-ion battery Fuse Panel 1-800-435-0705 CUSTOMER ASSISTANCE Visit idealheatseeker.com for a demonstration! Hot/cold temperatures and difference (6) Cursors continuously find hottest and coldest temperatures Adjustable LCD brightness 6 hour battery life Microphone records voice annotations Speaker USB Connector Power Port Micro SD card Easy-to-use navigation and set-up keys THERMAL IMAGERS Move cursor to convey real-time temperature anywhere on screen Side door allows quick access to headphone and USB connections, charging port and removable Micro SD card ThermalVision™ PC Software Included Easy-to-use software allows report generation. Provides Real-time Analysis for: Electrical Safety Energy Efficiency Data Center Thermal Mapping Preventive Maintenance Building Maintenance 1-800-435-0705 CUSTOMER ASSISTANCE WWW.IDEALINDUSTRIES.COM D-11 TEST & MEASUREMENT SureTest® Circuit Analyzers Description s -EASURESVOLTAGEDROPUNDERLOAD Cat. No. ® s (OTANDNEUTRALCONDUCTORIMPEDANCES SureTest Circuit Analyzer - Tests AFCIs wiring, tests for shared neutrals 61-165 s %STIMATES,OADON,INE%,, UPTO! SureTest® Circuit Analyzer 61-164 s 4ESTS'&#)SAND%0$SFORPROPEROPERATION s 3UPER BRIGHTDISPLAY Accessories s (IGHACCURACIES Includes s 4RUE2-3 Carrying Case 61-179 s ,INEVOLTAGE 1’ Extension Cord 61-182 61-165 Optional s 0EAKVOLTAGE Ground Continuity Adapter 61-175 s &REQUENCY Isolated Ground Adapter 61-176 s 'ROUNDTONEUTRALVOLTAGE Alligator Clip Adapter 61-183 s 'ROUNDIMPEDANCE s )DENTIFIESPROPERWIRINGIN  WIRERECEPTACLES Specifications Range & Resolution s )DENTIFIESFALSEBOOTLEG GROUNDS s #ONDUCTSTESTINGWITHOUT DISTURBINGSENSITIVELOADS s 6ERIFIESISOLATEDGROUNDS WITH ADAPTER CIRCUIT ANALYZERS s  YEARWARRANTY ! ! !LOADTESTS 61-183 300V Accuracy AC Voltage 85.0 - 265.0 VAC 1.0% Frequency 45.0 - 65.0 Hz 1.0% Impedance 0.00 - 1.99 1 5.0% Ground-Neutral Voltage 0.0 - 24.0 VAC 2.0% % Voltage Drop 12A, 15A, 20A load tests 0.1% - 50.0% 5.0% GFCI Test Current/Time 6.0 - 9.0 mA 0.0 - 6500 mS 2.0% SureTest® Circuit Analyzer Functions Voltage Drop s .%#RECOMMENDSNOMORE than 5% voltage drop s (IGHERVOLTAGEDROPLEADSTO heat buildup and performance issues s 6ISAPOORLEVELFORVOLTAGELOAD 61-175 Line Voltage s 3PECIlCATIONIS6!#   61-182 61-176 (108 to 132 VAC) s 4RUE2-3ENSURESACCURACYIN harmonic environments Ground-to-neutral Voltage s 'OODCIRCUITHAS6!#ORLESS s (IGHERREADINGINDICATESLOADED circuit, harmonic distortion or shared neutral Ground Impedance s 'ROUNDIMPEDANCESHOULDBE 11 or less (0.25 1 or less for sensitive equipment to run properly) GFCI s !PPLIESA M!FAULTCURRENT and measures the trip time s !PPLIESAM!FAULTCURRENTTO check for equipment protection Troubleshoots branch circuit problems with a variety of tests at the receptacle. D-12 WWW.IDEALINDUSTRIES.COM AFCI testing with alligator clips on an installed device. 1-800-435-0705 CUSTOMER ASSISTANCE AFCI/GFCI Tester s 4ESTS!&#)SCIRCUITWIRING s 4ESTS'&#)SFORPROPEROPERATION s 4ESTSFORSHAREDNEUTRALS s 6ERIFIESWIRINGCONFIGURATION s #OMPACTSIZEFITSCOMFORTABLYINPOCKET s  YEARWARRANTY Description Cat. No. AFCI/GFCI Circuit Tester 61-059 C-50 w/Belt clip Accessories Optional 1’ Cord Adapter 61-177 Alligator Clip Adapter (3-wire) 61-184 Alligator Clip Adapter (2-wire) TL-532A Carrying Case with Belt Clip C-50 Voltage Performance Monitor s 2 EAL TIME42-3VOLTAGE FREQUENCY ANDHARMONICSMONITORING Applications Monitor voltage near sensitive equipment s ,OGSVOLTAGE SAGS SWELLSANDIMPULSES s 3ELECTABLETHRESHOLDSBASEDONTHE MOSTACCEPTEDINTERNATIONALSTANDARDS DEFAULTSTO)4)# sElectricians – Eliminate guesswork on service calls sBuilding Maintenance Technicians – Identify voltage caused equipment failures s #USTOMPROGRAMMABLEEVENT THRESHOLDS s )NVERTIBLEDISPLAY WHENITISNECESSARY TOPLUGINUPSIDEDOWN sEquipment Manufacturers – Eliminate unnecessary warranty costs s  YEARWARRANTY sHospital/IT Maintenance Engineers – Monitor voltage quality to critical equipment * Captures events that would affect equipment on branch circuit Description Cat. No. Voltage Performance Monitor 61-830 Includes Adapters (set of 4) PA-830 Carrying Case 61-179 Optional Alligator Clip Adapters (2-wire) TL-532A 1 ft. US Extension Cord 61-177 Kit with (1) SureTest® 61-164, (2) VPM 61-2003 61-830, Soft Case C-2004 Kit with (1) SureTest® 61-164, (4) VPM 61-830, Soft Case C-2004 N12966 300V See voltage through the eyes of your equipment Poor voltage quality increases facility expenses, warranty costs and downtime plus SHORTENSTHELIFEOFEQUIPMENT4HE)$%!,60-IDENTIlESONLYTHOSEVOLTAGECONDITIONSTHAT can damage equipment or cause equipment failure. 61-179 Specifications Accessories ANALYZERS sInstallation and Service Technicians – Monitor voltage at point of equipment connection s -EASURES4($ANDLOGSPERIODSOVER LINETONEUTRAL 61-830 Operating Range Memory Sampling Method 15-265V Continuous (128 samples per cycle) Voltage Accuracy 1% Impulse Detection 6μs, 4kV Harmonic Distortion PA-830 513 Events 2%, FFT to 51st 61-2004 1-800-435-0705 CUSTOMER ASSISTANCE WWW.IDEALINDUSTRIES.COM D-13 TEST & MEASUREMENT 3-Phase Power Analyzer s 4RUE2-3 POWER & ENERGY MEASUREMENTS s 3 INGLE ORTHREE PHASE MEASUREMENTS s +ILOWATTSK7 s 5 PTOONEMONTHOFRECORDINGTIME s  CHANNELSFORVOLTAGEPLUS  CHANNELSFORCURRENT MEASUREMENTS s 6OLT AMPERES6! s )NDUCTIVEREACTIVEPOWERKVAR, s #APACITIVEREACTIVEPOWERKVAR# s 0OWERFACTOR0& s " ACKLITDISPLAY s &REQUENCY s 0 ROGRAMMABLETRIGGER POINTSAND STARTSTOPTIME s +ILOWATTHOURSK7H s %ASYSET UPANDINTERACTIVE DEMO#$ s 4OTALHARMONICDISTORTION4($ s  YEARWARRANTY HARMONICS MEASUREMENT Description Cat. No. Power Analyzer Kit 61-807 Accessories POWER QUALITY Optional 1000AAC Clamps (set of 3) 100AAC Neutral Clamp (1) 2000AAC Clamps (set of 3) 5AAC Compact Clamps (set of 3) 100AAC Compact Clamps (set of 3) 200/2000/20000AAC Flexible Clamp adapters (set of 3) N12966 600V s ( ARMONICFACTORIZATION&&4 TO STHARMONIC Specifications 61-811 61-813 61-810 61-819 61-820 61-457 Range & Resolution 20 to 600 V (phase-neutral) AC VOLTAGE 20 to 866 V (phase-phase) AC CURRENT 10 to 1000A (with supplied clamp adapters) ACTIVE POWER 866 kW (with supplied clamp adapters) REACTIVE POWER 866 kW (with supplied clamp adapters) POWER FACTOR 0.5 to 1.0 Accuracy 0.5% 1.0% 1.0% 1.0% 1.0% 100AAC Neutral Clamp (61-813) Test Leads with Alligator Clips (TL-805) Power Analyzer RS-232 Interface/ Power Supply 1000AAC Clamp Adapters (61-811) D-14 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 CUSTOMER ASSISTANCE Insulation Testers s #HECKSNEWINSTALLATIONSFOR DAMAGEDINSULATION s #HECKSEXISTINGINSTALLATIONSAND MOTORWINDINGSFORBREAKDOWNS ININSULATION s  YEARWARRANTY Description Cat. No. Insulation Meter w/PI, DAR, Remote Probe 61-797 Insulation Tester 61-795 61-797 N12966 600V 61-795 Includes: Test Leads Carrying Case 61-797 Includes: Test Leads 61-795 TL-795 C-795 600V TL-797 Remote Probe TL-797RP Carrying Case C-230 Test Voltage Voltage AC/DC Continuity Resistance Insulation Resistance Earth-Bond Resistance Range & Resolution 61-795 61-797 250/500/1000 VDC 50/100/250/500/1000 VDC 0.1-600.0 V 0.1-600.0 V 0.01-20.0 1 — 0-200.01 — Up to 4000M 1 Up to 20G 1 — 0.01 1 to 40.00k 1 Ground Resistance Meters s !UTORANGING s !UTOPOWEROFF s (ARDCASEINCLUDED s  YEARWARRANTY 61-796 61-920 INSULATION/GROUND TESTERS Specifications Accessories 300V TL-796 Description Cat. No. Ground Resistance Clamp Meter 61-920 3-Pole Ground Resistance Tester - includes TL-796 lead set kit 61-796 Earth Resistance Lead Set Kit TL-796 Specifications N12966 Range & Resolution 61-920 0/120/1200 1 Ground Resistance Ground Leakage Current 100m/1000m/15/30 A 1-800-435-0705 CUSTOMER ASSISTANCE Accuracy 1.5% 2.0% Range & Resolution 61-796 20.00/200.0/2000 1 — Accuracy 2.0% — WWW.IDEALINDUSTRIES.COM D-15 TEST & MEASUREMENT Vol-Con® Elite Digital Voltage Testers s 4ESTSFOR!#6OLTAGEFROM 6!# 61-092 s 4ESTSFOR$#6OLTAGEFROM 6$# s 6ISUALANDAUDIBLEWARNING s !UDIBLECONTINUITY s .ON CONTACTVOLTAGEINDICATION 6!# s ,OWIMPEDANCETOELIMINATEGHOSTVOLTAGES s ,OWBATTERYINDICATOR s 2EPLACEABLESILICONETESTLEADS s )NTEGRALLEADSTORAGE s  YEARWARRANTY N12966 Accessories Description Cat. No. ® Vol-Con Elite Digital Voltage Tester w/vibration mode 61-092 Vol-Con® Elite Digital Voltage Tester 61-090 1000V Includes Silicone Test Leads TL-102 Optional Carrying Case C-90 Solenoid Voltage Testers s %XTREMELYRUGGEDANDRELIABLE s 6IBRATESWHENVOLTAGEIS PRESENT 61-076 s )NDICATES!#$#VOLTAGELEVEL VOLTAGE TESTERS s 2EPLACEABLELEADSWITH SHIELDEDPROBETIPS 600V s "RIGHT LONG LIFE,%$SAND NEONINDICATORLAMP Accessories s $UALVOLTAGEINDICATIONFOR BACKUPSAFETY Standard Test Leads Includes 61-070 Optional Resistor-fused Leads* Description Vol-Con® Voltage/Continuity Tester, 5-600V AC/DC ® Vol-Test Voltage Tester, 100-600V AC/DC 61-072 Padded Nylon Case Cat. No. 61-076 61-065 C-90 Leather Case 61-010 Batteries 61-201 *Special, current-limiting resistor in each lead acts as a fuse to open in a short- circuit situation XL-Series Solenoid Voltage Testers s 2UGGEDANDRELIABLETESTER 61-086 nu t ag it y AUDIBLE Vo l s 2EPLACEABLELEADSWITH SHIELDEDPROBETIPS n® -Co Tes ol ts s )NDICATES!#$#VOLTAGELEVEL V s 6IBRATESWHENVOLTAGEISPRESENT e & o n ti C s "RIGHT LONG LIFE,%$SAND NEONINDICATORLAMP s $UALVOLTAGEINDICATIONFOR BACKUPSAFETY Accessories s #OMPACTSIZE Standard Test Leads s  YEARWARRANTY Optional Description Includes Resistor-fused Leads* Cat. No. 600V Padded Nylon Case TL-80 TL-82 C-90 ® 61-086 Leather Case ® 61-085 *Special, current-limiting resistor in each lead acts as a fuse to open in a short-circuit situation. Vol-Con XL Voltage/Continuity Tester, 6-600V AC/DC Vol-Test XL Voltage Tester, 80-600V AC/DC D-16 N12966 WWW.IDEALINDUSTRIES.COM 61-010 1-800-435-0705 CUSTOMER ASSISTANCE Split-Jaw™ Smart Meter s -EASURES !!# s -EASURES 6!# s -EASURES 6$# s -EASURES 1 s !UDIBLECONTINUITY s $ATAHOLD s )NTEGRALLEADSTORAGE s 2EPLACEABLETESTLEADS s !UTOPOWEROFF s ,OWBATTERYINDICATION N12966 s  YEARWARRANTY 600V 1000V Specifications AC Voltage Description Cat. No. DC Voltage Split-Jaw™ Smart Meter 61-096 AC Current Resistance Includes: Test Leads. 61-096 1.3 - 750 V 1.8 - 1000 V -0.6 - 1000 V 0.6 - 200.0A 0 - 2000 1 1.5% 1.0% 3.0% 1.0% *Note: Jaw opening is 0.6 in. (16mm) - up to 1/0 copper cable. ELECTRICAL TESTERS Circuit Breaker Finders s &ULLYAUTOMATICOPERATION s 0OSITIVELYIDENTIFIESCIRCUITBREAKERS ANDFUSESWITHOUTSERVICEINTERRUPTION s 3ELFCALIBRATING s 6ISUALANDAUDIBLEINDICATORS s  YEARWARRANTY 61-534 w/GFCI receptacle tester N12966 61-532 Description Cat. No. Circuit Breaker Finder w/Digital Receiver & GFCI Circuit Tester 61-534 Circuit Breaker Finder w/Analog Receiver 61-532 TL-532A Specifications Alligator clip adapter allows connections to exposed wiring. Lighting adapter allows connection to light lXTURES 1-800-435-0705 CUSTOMER ASSISTANCE Operating Voltage Operating Frequency 61-532 61-534 100 - 140 VAC 47 - 63 Hz 100 - 250 VAC 47 - 63 Hz WWW.IDEALINDUSTRIES.COM D-17 TEST & MEASUREMENT VoltAware™ Non-Contact Voltage Tester s )NDICATESPRESENCEOF VOLTAGEFROM 6!# s 6ISUALINDICATIONOF VOLTAGE Convenient button turns audible voltage indication on or off. s 3ELECTABLEAUDIBLE INDICATIONOFVOLTAGE E-Z Check® Circuit Tester s 4ESTSFORCORRECTWIRING OPENGROUND REVERSE POLARITY OPENHOT OPEN NEUTRAL HOTONNEUTRAL HOT ANDGROUNDREVERSEDWITH OPENHOT ANDGROUNDFAULT INTERRUPTIONIN WIRE 6!#CIRCUITS s 3LEEK COMPACTDESIGN s .O SLIPERGONOMICDESIGN MAXIMIZESCOMFORT s 'REEN,%$INDICATES POWERON s 0REMIUMNEONLAMPS PREVENTFALSEREADINGS s ,OWBATTERYINDICATOR s 4OUGH IMPACT RESISTANTCASE s "ATTERYREPLACEMENT !!!SIZE s  YEARWARRANTY 61-051 1000V N12966 s  YEARWARRANTY Description Cat. No. ® Description Cat. No. VoltAware™ Non-Contact Voltage Tester 61-025 ELECTRICAL TESTERS VoltSensor™ Non-Contact Voltage Tester s 4ESTSFORVOLTAGEFROM  6!# E-Z Check Plus GFCI Circuit Tester 61-051 E-Z Check® Circuit Tester 61-035 Receptacle Testers s 7ARNSAGAINSTFAULTY WIRINGIN WIRE RECEPTACLES s &ORUSEON6!# CIRCUITS s  YEARWARRANTY s !UDIBLEANDVISUAL INDICATION 61-501 s ,OCATESBREAKSALONGLIVE INSULATEDWIRES s 4ESTSFORENERGIZEDCIRCUITS s "ATTERYREPLACEMENT ,2  s  YEARWARRANTY N12966 600V Description Cat. No. Volt-Sensor® Non-Contact Voltage Tester 61-063 Description Cat. No. GFCI Receptacle Tester 61-501 Receptacle Tester 61-500 Test-Glo™ Circuit Tester Continuity Tester s #HECKSCONTINUITYOFDEADCIRCUITSAND GROUNDONCONDUITSYSTEMSAND IDENTIFIESWIRESINMULTI WIRECABLES s )NDUSTRIAL QUALITYTESTERCHECKS VOLTAGEFROM6TO6!#$# s ,IGHTSIGNALINDICATESCOMPLETEDCIRCUIT s 2ESISTORSREDUCEVOLTAGE REACHINGLEADS s .EONTESTLAMPATFRONTOFPROBE s "ULB INENDCANSERVEASFLASHLIGHT s  INLEADˆRATED 6 s 0OCKETCLIPFUNCTIONSASPROBE s  YEARWARRANTY s 2EMOVABLE FTTESTLEADWITHALLIGATORCLIP s  YEARWARRANTY D-18 Description Cat. No. Description Cat. No. Continuity Tester 61-030 Test-Glo™ Circuit Tester 61-040 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 CUSTOMER ASSISTANCE Digital Light Meter 3-Phase/Motor Rotation Tester s -EASURESALLVISIBLELIGHT SOURCES s )DENTIFIESTHREE PHASE SEQUENCE s -EASURES,%$LIGHTING s -EASURESINFOURRANGES UPTO &#OR  ,UX s )NDICATESMOTORROTATION s  BASICACCURACY s &ORUSEUPTO6 s $ATAHOLDMODE s  YEARWARRANTY s #HECKSFOROPENPHASES s -AXREADINGMODE s !UTOZEROADJUSTMENT s ,OWBATTERY INDICATION N12966 s !UTOPOWEROFF 300V s 2EMOTESENSOR WITHINM Description Cat. No. Cat. No. 3-Phase/Motor Rotation Tester 61-521 61-686 Includes Carrying Case. N12966 Description Digital Light Meter Infrared Thermometer 3-Phase Sequence Tester s -EASUREMENTRANGE ²&TO²& s &ORUSEUPTO6 s #OLOR CODEDINSULATORSOVERALLIGATOR CLIPS s $ISTANCESPOT s -ODES!VE $IFFERENCE (I,OLIMITSWALARM -AX -IN ,OCK s 3HOCKRESISTANTHOUSING s %ASYTOREAD s  YEARWARRANTY s %MISSIVITY2ANGE !DJUSTABLEFROM TO SPECIALTY TESTERS Includes Carrying Case. s 0RECISION+ TYPE THERMOCOUPLEOPTIONAL s "ACKLIGHT s !UTOPOWEROFF s ,OWBATTERYINDICATOR s  YEARWARRANTY Description Cat. No. Description Cat. No. Infrared Thermometer 61-685 3-Phase Sequence Tester 61-520 Includes Carrying Case. Includes Carrying Case. Accessories Optional K-type Thermocouple 61-461 Specifications Object Temperature Range & Resolution Accuracy -27 to 932°F (-33 to 500°C) +/- 2% of reading or +/- 4°F (+/-2°C) whichever is greater 1-800-435-0705 CUSTOMER ASSISTANCE WWW.IDEALINDUSTRIES.COM D-19 TEST & MEASUREMENT Magnetic Strap Test Leads s &REESUPHANDSTOHELPWORK SAFELY s &ITS3ERIES -ULTIMETERS TL-100 Description Cat. No. Magnetic Strap 61-565 TL-104 USB Cable s 0ROVIDESSAFE EASY MEASUREMENTOF!#CURRENT TLF-252 s %XTENDSTHECURRENT MEASUREMENTCAPABILITIESOF DIGITALMULTIMETERS s !#MILLI VOLTOUTPUT M6!#M! ACCESSORIES Description Cat. No. Optical USB Cable for 490 Series Meters & Software 61-902 Description Cat. No. Premium Test Leads w/alligator clips TL-100 Silicone Test Leads TL-102 Test Leads w/large alligator clip TL-104 Fused Test Leads w/alligator clips, 10A/600V, CAT III - 1000V TLF-252 Current Clamp Adapter Description Cat. No. 600A AC/DC Clamp Adapter 2 ft. lead length 61-334 Specifications 61-334 AC Current DC Current Output Signal Max Conductor Size 1 – 600 A 1 – 600 A 1mV/A 1.125” (28.5cm) N12966 D-20 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 CUSTOMER ASSISTANCE Thermocouple s -EASURESUPTOƒ&ƒ# s + TYPETHERMOCOUPLEPLUGSINTODIGITALMULTIMETERVOLTAGE JACKSWITH ADAPTER Description Cat. No. Beaded K-type Thermocouple 61-461 Thermocouple Adapter 61-465 61-461 61-465 Carrying Cases C-90 C-290 61-445 Description Cat. No. Leather Carrying Case - for use with 61-065, 61-076, 61-085, 61-086 61-010 Small Nylon Carrying Case w/four pockets 61-445 ® ® Nylon Carrying Case - for use with all Vol-Con and Vol-Test Voltage Testers C-90 Nylon Carrying Case - for use with Digital Multimeters C-290 ACCESSORIES 61-010 Carrying Case Selection Guide 830 61-830 61-775 770 61-773 61-765 760 61-763 61-746 740 61-744 61-704 61-702 700 61-614 610 61-610 61-498 490 61-497 61-486 480 61-484 360 61-361 61-342 340 61-340 s 61-312 s 310 61-310 61-096 61-092 61-090 61-086 61-085 61-076 61-165 Nylon Carrying Case Nylon Carrying Case Nylon Carrying Case Nylon Carrying Case Nylon Carrying Case Nylon Carrying Case Nylon Carrying Case Nylon Carrying Case 160 61-164 61-179 C-50 C-90 C-230 C-290 C-700 C-760 C-770 61-065 61-059 VOLTAGE TESTERS s s s s s 1-800-435-0705 CUSTOMER ASSISTANCE s s s s s s s s s s s s s s s s s s s s s s s s s WWW.IDEALINDUSTRIES.COM D-21 TEST & MEASUREMENT REPLACEMENT PARTS/SAFETY FUSES F-1 0.5A (250V) 6.35 x 38mm F-105 1A (600V) 10.3 x 35mm F-310 250mA (250V) 5 x 20mm F-312 500mA (250V) 5 x 20mm F-314 10A (250V) 5 x 20mm F-340 0.5A (500V) 6.35 x 32mm F-341 10A (1000V) 10 x 38mm F-497 440mA (1000V) 10 x 35mm F-498 11A (1000V) 10 x 38mm F-797 315mA (1000V) 5 x 32mm LA-3893 2A (600V) 6.35 x 25.4mm LA-3898 0.25A (500V) 5 x 32mm BATTERIES 61-201 1.5V (LR44) — 1.5V (AA) — 1.5V (AAA) — 9V TEST LEADS TL-34 Leads w/pin connectors TL-56 Test leads TL-95 Test leads TL-100 Test leads w/alligator clips TL-102 Silicone test leads TL-104 Test leads w/large alligator clips TL-310 Test leads TL-795 Test leads TL-797 Test leads 61-797 61-795 790 61-775 61-773 770 61-765 760 61-763 740 61-744 61-746 61-704 700 61-702 610 61-614 600 61-610 490 61-605 61-486 480 61-484 61-361 340 360 61-340 61-342 61-312 310 61-310 61-096 090 METER REPACEMENT PARTS SELECTION GUIDE 61-497 61-498 Replacement Parts Selection Guide s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s s Safety in the Field 4HEPOWERDEMANDSOFTODAYSHIGH TECHWORLDHAVECAUSEDAMARKEDINCREASEIN OCCURRENCESANDLEVELSOFTRANSIENTOVERVOLTAGES4HE)NTERNATIONAL%LECTROTECHNICAL #OMMISSION)%# HASDEVELOPEDASAFETYSTANDARDSMODELFORMEASUREMENT CONTROLAND LABORATORYUSE Category In4HESIGNALLEVELFORTELECOMMUNICATIONS ELECTRONICANDOTHERLOW ENERGY EQUIPMENTWITHTRANSIENT LIMITINGPROTECTION0EAKIMPULSETRANSIENTRANGEISn VOLTS WITHAOHMSOURCE Service Entrance Safety in the Field Meter Service Entrance Underground Service Category II n4HELOCALLEVELFORFIXEDANDNON FIXEDPOWEREDDEVICESINCLUDINGAPPLIANCES LIGHTINGANDPORTABLEEQUIPMENT/UTLETSLOCATEDMORETHANFEETFROM#!4)))SOURCESAND FEETFROM#!4)6SOURCES0EAKIMPULSETRANSIENTRANGEISFROMn VOLTSWITHA OHMSOURCE Category III –4HEDISTRIBUTIONLEVELFORFIXEDPRIMARYFEEDERSORBRANCHCIRCUITS#IRCUITS THATARESEPARATEDFROM#!4)6SOURCESBYATLEASTONELEVELOFTRANSFORMERISOLATION0EAK IMPULSETRANSIENTRANGEISn VOLTSWITHAOHMSOURCE Category IV PROPOSED n4HEPRIMARYSUPPLYLEVELFORTHEHIGHESTLEVELSOFTRANSIENT OVERVOLTAGE)NCLUDESTHEUTILITYSERVICEBOTHOUTSIDEANDATTHESERVICEENTRANCE SERVICEDROP FROMTHEPOLETOTHEBUILDING OVERHEADLINETOREMOTEBUILDINGS ANDUNDERGROUNDLINETOA WELLPUMP0EAKIMPULSETRANSIENTRANGEISn VOLTSWITHLESSTHANAOHMSOURCE Outbuilding Meter Service Entrance Transformer Outbuilding Meter Underground Service CAT I Copiers s%LECTRONIC equipment sLOWENERGY EQUIPMENTWITH TRANSIENTLIMITING protection CAT II Appliances, PCs, TVs sOutletSANDLONG BRANCHEQUIPMENT s!LLOUTLETSATMORE THANMFT FROM#ATEGORYIII source s!LLOUTLETSATMORE THANMFT FROM#ATEGORYIV source CAT III MC Panels CAT IV Exterior Transformers, Meters sFEEDERSANDSHORt BRANCHCIRCUITs sDistribution PANELDEVICEs s(EAVYAPPLIANCE outletSWITHhSHORt” CONNECTIONSTO SERVICEENTRANCE sOutSIDEAND SERVICEENTRANCE s3ERVICEDROPFROM POLETOBUILDING s/VERHEADLINETO DETACHEDBUILDING s5NDERGROUNDLINE TOWELLPUMP Visit our website for more technical product details, application support, white papers, videos and software! D-22 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 CUSTOMER ASSISTANCE