Transcript
®
Multi-Application Peripherals and Accessories Non-Coded Manual Station 300 Series (Metal)
ULC Listed*
FEATURES:
• Single Action • Durable Extruded Aluminum Construction
DOWN
PULL
• Simple Test & Reset
FIRE ALARM
• Handle Hangs Down in Alarm
®
• Attractive, Low Profile Design • Standard Single Gang Mount • English, French, or Bilingual • Single or Two-Stage Alarm
MS-301C
DESCRIPTION:
SPECIFICATIONS:
Attractive and durable, MS-300 Series pull Stations are non-coded, single action devices which initiate an alarm signal when pulled.
The single action pull station shall be constructed of extruded aluminum and finished in red enamel paint to allow quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. Those stations installed in a two-stage system shall come equipped with an internal key switch designed to operate the 2nd stage alarm initiating circuit. The manual fire alarm stations shall be installed according to the specific requirements outlined in the applicable codes and standards.
The MS-300 pull stations are constructed of durable extruded aluminum and finished in red. An abrasion resistant label with large, raised letters provides clear legible instructions. The unique side reset design is simple and does not detract from the appearance of the station. The model MS-302C (two-stage) is similar to the MS-301C except it contains an additional normally open switch for General Alarm (G.A.). The G.A. switch is accessible only after the handle has been pulled. A General Alarm key is supplied with each unit. OPERATION:
Pulling firmly on the station’s handle will open the station and activate the internal switch to trigger the alarm detection circuit. The handle, once pulled, will remain open until the station is reset.
ORDERING INFORMATION: PID #
DESCRIPTION
MS-301C
Simple Action, Single Stage Pull Station
MS-302C
Simple Action, Two-Stage Pull Station (Key Switch)
MODELS LISTED ABOVE ARE ENGLISH LANGUAGE, ADD ‘F’ FOR FRENCH – ‘B’ FOR BILINGUAL e.g. MS-301C, MS-301CF, MS-301CB
The MS-302C provides a key switch which will be accessible only after the handle is pulled. Operation of the key switch, when connected to a separate general alarm circuit, will initiate the 2nd stage of a two-stage alarm signalling system. The station is reset with a 1/8” diameter screwdriver.
© 2000 Simplex International Time Equipment Co. Ltd.
S01575-100-1 7/00
DIMENSIONS:
PULL
RESET HOLE
DOWN
FIRE ALARM
114.3mm (4.5”)
®
25.4mm (1.0”) 89.9mm (3.5”)
30.48mm (1.2”)
CONNECTION DIAGRAM:
BLUE
BLUE
G.A. WHITE
WHITE
TO NEXT STATION OR END-OF-LINE DEVICE
FROM PREVIOUS STATION OR FIRE ALARM CONTROL RED BLACK RED BLACK
TO NEXT STATION OR END-OF-LINE DEVICE
NOTES: 1. WIRE AS SHOWN SO THAT SUPERVISION OF CONNECTIONS IS MAINTAINED. 2. MOUNTS TO 2” X 4” X 2.25” OUTLET BOX. 3. SWITCH RATINGS: ALL MODELS 1 A @ 30 VDC; 0.1 A @ 125 VAC.
®
S01575-100-1 7/00 2400 Skymark Avenue, Mississauga, Ontario L4W 5K5 Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Printed in Canada.