Multi-Application Peripherals and Accessories
ULC Listed
Annunciators, 4616 Series, 24 Point Serial LED Annunciators
Features
• LED annunciator for use with the Simplex 4010 fire alarm control panel
• Information is transmitted over one twisted, shielded pair
ZONE 1
ZONE 9
ZONE 17
ZONE 2
ZONE 10
ZONE 18
ZONE 3
ZONE 11
ZONE 19
ZONE 4
ZONE 12
ZONE 20
• 24 Red/Yellow LEDs, jumper selectable
ZONE 5
ZONE 13
ZONE 21
• Long life LEDs
ZONE 6
ZONE 14
ZONE 22
• Low current consumption
ZONE 7
ZONE 15
ZONE 23
ZONE 8
• Supervised from Simplex 4010 control panel
ZONE 16 SYSTEM TROUBLE TROUBLE SYSTÈME
ZONE 24 POWER ON ALIM. MARCHE
• Lamp test 4616 Serial LED Annunciator
• Surface mount on standard electrical box • 18 gauge steel casing Description
The Simplex 4616 series serial LED annunciators are designed for use with the Simplex 4010 series fire alarm control panel. Initiating circuit alarm and trouble information is transmitted to the annunciator over one twisted, shielded pair. Standard zone information (i.e., Zone 1, Zone 2) is provided on “slip-in” labels. Specific zone information may be typed on the reverse side (i.e. east wing, first floor) of the label. The 4616 series annunciators come standard with 24 points of annunciation, a “Power On” LED, a “System Trouble” LED and a “Lamp Test” feature. A piezo and a piezo silence are available as options. The various configurations are listed on the back.
Available models Model
Description
4616-9301CA
24 Point Annunciator
4616-9302CA
24 Point Annunciator with Piezo
4616-9303CA
24 Point Annunciator with Piezo and Silence
4616 Series LED Annunciator Specifications General Specifications Voltage
18-32 VDC, system supplied
Standby operating current
70.6 mA
Alarm current
308 mA (all LEDs)
Piezo current
16 mA
Communications
N2 external annunciator communications line from 4010 FACP
Temperature Range
32° F to 120° F (0° C to 49° C)
Humidity Range
10% to 90% RH, non-condensing, at 90° F (32° C)
Dimensions
7 1/4” H x 7 1/4” W x 1 3/8” D (185 mm x 185 mm x 35 mm)
Mounting Information Surface mount on a standard single gang electrical box or on front of 4010 fire alarm control panel © 2000 Simplex International Time Equipment Co. Ltd.
S01575-134-2 08/01
Wiring Reference
FIRE ALARM CONTROL
12:02:15pm FIRE ALARM
ALARM ACK
** SYSTEM IS NORMAL** Mon 8 -Mar-99
SU PV.
SUPV. ACK
T
SYSTEM ROUBLE
ALARM SILENCE
ALARM SILENCE
TROU BLE AC K
AC POWER
SYSTEM RESET
CAU TION
DISC ONN ECT POWER BEFORE SERVICING
ZONE 1
ZONE 9
ZONE 17
ZONE 2
ZONE 10
ZONE 18
ZONE 3
ZONE 11
ZONE 19
ZONE 4
ZONE 12
ZONE 20
ZONE 5
ZONE 13
ZONE 21
ZONE 6
ZONE 14
ZONE 22
ZONE 7
ZONE 15
ZONE 8
ZONE 16 SYSTEM TROUBLE TROUBLE SYSTÈME
ZONE 1
ZONE 9
ZONE 17
ZONE 2
ZONE 10
ZONE 18
ZONE 3
ZONE 11
ZONE 19
ZONE 4
ZONE 12
ZONE 20
ZONE 5
ZONE 13
ZONE 21
ZONE 6
ZONE 14
ZONE 22
ZONE 7
ZONE 15
ZONE 23
ZONE 8
ZONE 16
ZONE 24
ZONE 23 ZONE 24 POWER ON ALIM. MARCHE
4616 Series LED Annunciator
– – – • •
One #18 AWG twisted shielded pair Two #18-12 AWG - Power One #18 AWG as needed - See below Refer to Field Wiring Specifications for distance limitations. Maximum distance determined by 4602 Field Wiring Specifications.
4010 Series Fire Alarm Control Panel
Options Hardwired Controlled
I/O Controlled
Power On LED
P
P
System Trouble LED
P
P
Controlled by System Trouble LED
P
Piezo*
P
* A local piezo silence switch is available as an option.
Mounting Information
7 1/4” (185 mm)
1 3/8” (35 mm)
7 1/4” (185 mm)
ZONE 1
ZONE 9
ZONE 17
ZONE 2
ZO NE 10
ZONE 18
ZONE 3
ZONE 11
ZONE 19
ZONE 4
ZONE 12
ZONE 20
ZONE 5
ZONE 13
ZONE 21
ZONE 6
ZONE 14
ZONE 22
ZONE 7
ZONE 15
ZONE 23
ZONE 8
ZONE 16 SYSTEM TROUBLE TROUBLE SYSTÈME
Side View
®
Single Gang Box
ZONE 24 POWER ON ALIM. MARCHE
Front View
S01575-134-2 08/01 2400 Skymark Avenue, Mississauga, Ontario L4W 5K5 Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Printed in Canada.