S01575-134-2 8/03 4616 Series 24 Point I/o Serial Annunciator For Use With The 4010

   EMBED


Share

Transcript

® Multi-Application Peripherals and Accessories ULC Listed Annunciators, 4616 Series, 24 Point Serial LED Annunciators Features • LED annunciator for use with the Simplex 4010 fire alarm control panel • Information is transmitted over one twisted, shielded pair ZONE 1 ZONE 9 ZONE 17 ZONE 2 ZONE 10 ZONE 18 ZONE 3 ZONE 11 ZONE 19 ZONE 4 ZONE 12 ZONE 20 • 24 Red/Yellow LEDs, jumper selectable ZONE 5 ZONE 13 ZONE 21 • Long life LEDs ZONE 6 ZONE 14 ZONE 22 • Low current consumption ZONE 7 ZONE 15 ZONE 23 ZONE 8 • Supervised from Simplex 4010 control panel ZONE 16 SYSTEM TROUBLE TROUBLE SYSTÈME ZONE 24 POWER ON ALIM. MARCHE • Lamp test 4616 Serial LED Annunciator • Surface mount on standard electrical box • 18 gauge steel casing Description The Simplex 4616 series serial LED annunciators are designed for use with the Simplex 4010 series fire alarm control panel. Initiating circuit alarm and trouble information is transmitted to the annunciator over one twisted, shielded pair. Standard zone information (i.e., Zone 1, Zone 2) is provided on “slip-in” labels. Specific zone information may be typed on the reverse side (i.e. east wing, first floor) of the label. The 4616 series annunciators come standard with 24 points of annunciation, a “Power On” LED, a “System Trouble” LED and a “Lamp Test” feature. A piezo and a piezo silence are available as options. The various configurations are listed on the back. Available models Model Description 4616-9301CA 24 Point Annunciator 4616-9302CA 24 Point Annunciator with Piezo 4616-9303CA 24 Point Annunciator with Piezo and Silence 4616 Series LED Annunciator Specifications General Specifications Voltage 18-32 VDC, system supplied Standby operating current 70.6 mA Alarm current 308 mA (all LEDs) Piezo current 16 mA Communications N2 external annunciator communications line from 4010 FACP Temperature Range 32° F to 120° F (0° C to 49° C) Humidity Range 10% to 90% RH, non-condensing, at 90° F (32° C) Dimensions 7 1/4” H x 7 1/4” W x 1 3/8” D (185 mm x 185 mm x 35 mm) Mounting Information Surface mount on a standard single gang electrical box or on front of 4010 fire alarm control panel © 2000 Simplex International Time Equipment Co. Ltd. S01575-134-2 08/01 Wiring Reference FIRE ALARM CONTROL 12:02:15pm FIRE ALARM ALARM ACK ** SYSTEM IS NORMAL** Mon 8 -Mar-99 SU PV. SUPV. ACK T SYSTEM ROUBLE ALARM SILENCE ALARM SILENCE TROU BLE AC K AC POWER SYSTEM RESET CAU TION DISC ONN ECT POWER BEFORE SERVICING ZONE 1 ZONE 9 ZONE 17 ZONE 2 ZONE 10 ZONE 18 ZONE 3 ZONE 11 ZONE 19 ZONE 4 ZONE 12 ZONE 20 ZONE 5 ZONE 13 ZONE 21 ZONE 6 ZONE 14 ZONE 22 ZONE 7 ZONE 15 ZONE 8 ZONE 16 SYSTEM TROUBLE TROUBLE SYSTÈME ZONE 1 ZONE 9 ZONE 17 ZONE 2 ZONE 10 ZONE 18 ZONE 3 ZONE 11 ZONE 19 ZONE 4 ZONE 12 ZONE 20 ZONE 5 ZONE 13 ZONE 21 ZONE 6 ZONE 14 ZONE 22 ZONE 7 ZONE 15 ZONE 23 ZONE 8 ZONE 16 ZONE 24 ZONE 23 ZONE 24 POWER ON ALIM. MARCHE 4616 Series LED Annunciator – – – • • One #18 AWG twisted shielded pair Two #18-12 AWG - Power One #18 AWG as needed - See below Refer to Field Wiring Specifications for distance limitations. Maximum distance determined by 4602 Field Wiring Specifications. 4010 Series Fire Alarm Control Panel Options Hardwired Controlled I/O Controlled Power On LED P P System Trouble LED P P Controlled by System Trouble LED P Piezo* P * A local piezo silence switch is available as an option. Mounting Information 7 1/4” (185 mm) 1 3/8” (35 mm) 7 1/4” (185 mm) ZONE 1 ZONE 9 ZONE 17 ZONE 2 ZO NE 10 ZONE 18 ZONE 3 ZONE 11 ZONE 19 ZONE 4 ZONE 12 ZONE 20 ZONE 5 ZONE 13 ZONE 21 ZONE 6 ZONE 14 ZONE 22 ZONE 7 ZONE 15 ZONE 23 ZONE 8 ZONE 16 SYSTEM TROUBLE TROUBLE SYSTÈME Side View ® Single Gang Box ZONE 24 POWER ON ALIM. MARCHE Front View S01575-134-2 08/01 2400 Skymark Avenue, Mississauga, Ontario L4W 5K5 Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Printed in Canada.