Transcript
Installation S19-625 Hand-Held Drench Hose and Eye/Face Wash Table of Contents Pre-Installation Information . . . . . . . . . . . . . . . .2 Installation Instructions . . . . . . . . . . . . . . . . . . .3 Assembly of Components . . . . . . . . . . . . . . . . .4 Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
215-1622; EN 06-542 © 2007 Bradley Corporation Page 1 of 4 2/22/07
P.O. Box 309, Menomonee Falls, WI USA 53052-0309 PHONE 1-800-BRADLEY FAX (262) 251-5817 http://www.bradleycorp.com
S19-625
Installation
Pre-Installation Information Operation The eye/face body wash is activated when the handle on the valve is squeezed.
Components Eye/Face and Body Spray: The quick-access emergency eye/face and body spray features a softflow sprayhead for flooding large areas as well as the eyes only. The integral flow control assures safe, steady flow under varying water supply conditions from 30-90 PSI. NOTE: The ANSI Z358.1 standard requires an uninterruptible supply of flushing fluid at a minimum 30 PSI flowing pressure. Valve: The chrome-plated brass valve with extended handle stays open until manually closed. Recoiling Drench Hose: The 12’ (3655mm) self-coiling hose retracts for storage while allowing instant extension in emergency situations. Hose is high-visible yellow. Burst strength is 250PSI. Wall Bracket: Metal parts of the bracket are polished chrome plate.
WARNING Read this installation manual completely to ensure proper installation, then file it with the owner or maintenance department. Compliance and conformity to drain requirements and other local codes and ordinances is the responsibility of the installer.
Installation
Packing List
IS TH SIDE UP
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. Flush the water supply lines before beginning installation and after installation is complete. Test the unit for leaks and adequate water flow. Main water supply to the eyewash should be “ON” at all times. Provisions shall be made to prevent unauthorized shutoff. Flushing fluid should be tepid per ANSI Z358.1.
P.O
Da Da te Da tum te
TES
Sig ned Sig ned ned
. Box DIE ESS SEST THI 309 Tes AI S Rep t-op HEBGER UNI , Me Ven ort DO ÄT T EAC nom dur til(e anyera 1ST te MA one H Tes ch val DAI WÖ WE sig e Un ) wö ma ve( RE CHE EK Fal un ne t le ters che lfun s) ls, NTL rap en fon chr ntli ctio eac WI por basctio ICH ns h ift. ch 530 t imm. nne ZU immwe Jeg im S'il 51 ek me PRÜ lichTes edi and édi y nt Sig FEN ate ateà que des e tbe Stö trie ly. sig Un ned . me lqu n Sig ter nt. e valves run b prü bel g ne sch cho ow sof fen rift . se cha ort , bes qui que Da me ne sem lde täti Da te va ain n. gt Da te pas e te Sig fait et
R
The inspection and testing results of this equipment should be recorded weekly to verify proper operation. This equipment should be inspected annually to ensure compliance with ANSI Z358.1.
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA TEL: 1-800-BRADLEY
FAX: (262-251-5817)
http://www.bradleycorp.com 114-051
Workers who may come in contact with potentially hazardous materials should be trained regarding the placement and proper operation of emergency equipment per ANSI Z358.1. For questions regarding the operation or installation of this product, visit www.bradleycorp.com or call 1-800-BRADLEY. Product warranties may also be found under ”Product Information” on our web site at www.bradleycorp.com.
2
2/22/07
Bradley Corporation • 215-1622; EN 06-542
Installation
S19-625
Installation Instructions
10-3/4" (273mm)
Supplies required for installation • Three (3/8") wall anchors and three (3/8") bolts • Minimum 1/2" water supply pipe to connect to 1/2" NPT connector on hand-held unit • Pipe sealant or pipe dope • Sign-mounting hardware • Vacuum breaker as required by UPC, IPC and/or local plumbing codes
10-3/4" (285mm)
13-3/8" (340mm)
Step 1: Install mounting bracket to wall NOTE: Make sure that, when mounted, the eye wash unit will measure 33-45 inches from the top of the sprayheads to the finished floor. For usage as an eye/face wash, the top of the sprayheads of the S19-625 must be 33–45 inches from where the user stands per ANSI Z358.1. The unit must also be placed a minimum of 6" away from the nearest wall or obstruction. 1. Install three suitable wall anchors for use with 3/8" bolts (supplied by installer) into the wall at the desired location (see Figure 1a for eye wash dimensions and Figure 1b for bracket dimensions). 2. Bolt the mounting bracket to the wall using three 3/8" bolts (supplied by installer).
Figure 1a
2" (51mm)
4-11/32" (110mm) 2" (51mm)
Step 2: Assemble eye/face body wash unit 1. Assemble the component parts as shown in Figure 2 on page 4. • Be sure to apply pipe sealant to all pipe joints.
33-45" (838-1143mm) TO FINISHED FLOOR
27/32" (21mm)
2" (51mm) 4" (102mm)
Figure 1b
Step 3: Connect water supply 1. Connect the water supply to the unit (piping supplied by installer). 2. Mount the safety sign to the wall using the sign-mounting hardware supplied by installer. 3. Open the water supply line. Test for leaks and adequate water flow.
Bradley Corporation • 215-1622; EN 06-542
2/22/07
3
S19-625
Installation
Assembly of Components and Parts List
4.3 4.2
4
11 R
4.1
P.O. Box 309, Menomonee Falls, WI 53051
TEST THIS UNIT EACH WEEK DIESES GERÄT 1ST WÖCHENTLICH ZU PRÜFEN. ESSAI HEBDOMADAIRE
Test-operate valve(s) each week and sign below. Report any malfunctions immediately. Ventil(e) wöchentlich im Testbetrieb prüfen, bestätigt durch Unterschrift. Jegliche Störung sofort melden. Test le fonctionnement des valves chaque semaine et signe en bas. S'il y à quelque chose qui ne va pas fait un rapport immédiatement.
Date Datum Date
Signed Unterschrift Signe
Date Date Date
Signed Signed Signed
3
1
1.1 10 5
2
6 7
P.O. BOX 309, MENOMONEE FALLS, WI 53052-0309 USA TEL: 1-800-BRADLEY FAX: (262-251-5817) http://www.bradleycorp.com
114-051
8
9
Figure 2
NOTE: Items 1–8 come preassembled.
Item
4
Part No.
Qty
Description
Item
Part No.
Qty
Description
1
S27-265
1
Valve Assembly with Handle
5
141-008
1
Hanger
1.1
269-661
1
Handle only
6
110-212
1
Nut, Lock
2
S70-094
1
Wall Bracket
7
113-635
1
Nipple
3
153-337
1
Adapter
8
169-078
1
Coupling
4
S05-148
1
Angled EFW Assembly
9
269-053
1
Hose, 12’
4.1
S05-091P
1
Yoke Assembly
10
114-051
1
Safety Sign
4.2
S05-135
2
Sprayhead Assembly
11
204-421
1
Emergency Tag
4.3
S53-063
2
Dust Cover Assembly
2/22/07
Bradley Corporation • 215-1622; EN 06-542