Transcript
8901 Access Control Panel Installation Guide __________________________________________________________________________ 1. Introduction 2. Technical Specification 3. System Deployment 4. Panel Layout 5. Detailed Pin Assignment 6. Panel Configuration 7. Sample Connection Circuits System Reader Electrical Lock Door Alarm Door Ajar Door Sensor Release Button Panel Tamper
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 1 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 1. Introduction This document provides detailed description about the features, functions and setup of ACX 8901 Control Panel. A. Strength Native TCP/IP on board, 10/100Mbps communication speed Flexibility structure cabling, cat 5 cable, direct to hub or panel to panel daisy chain wiring. Multi-threading program, transactions upload to database server less than 2 sec under 50 panels. User defined 128 bits key for the data exchange between ACX 8901&8902 door access panel to ACX COM Server, prevent the real data to be snooped and simulated by other network point. User defined 128 bits key, scramble RS485 data exchange between ACX 8901&8902 door access panel and ACX reader, prevent reader data to be snooped and copied. Work with ACX 2081 I/O module, save the wiring cost and increase the data security (patented design) Support 7 x card number format, each card number format has 3 x facility code checking Work with ACX LCD reader, display interactive message Work with ACX emergency door open device Supervised Monitor of the Door Sensor Input, Prevent trouble close and open B. Features 32 bits microprocessor, 50MHz External device short circuit protection Thumbed protection Recoverable fuse protection. Status LED represents operating status Auto recover for the TCP/IP failure Battery on board for memory retention, 3 years Firmware can be on-line upgraded Real time clock, less than 1 sec deviation daily. Twin card operation (100 couples) Anti-passback Two door interlock
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 2 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ C. Panel Appearance
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 3 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 2. Technical Specification
Specification
Panel Inputs
8901 - 1 x IN and 1 x OUT Wigand reader or; - 1 x IN and 1 x OUT ACX scramble RS485 reader - 1 x door sensor input - 1 x request to exit input - 1 x auxiliary input - 1 x controller box tamper input - 1 x ACX high security key open door device - Power input monitoring : A.C. / D.C. / Backup Battary - Work with ACX high security door emergency open device, couple with random key switch & reset panel.
Panel Outputs
- 1 x E-Lock relay dry contact output, max. 10A current rating - 1 x Alarm relay dry contact output, max. 3A current rating - 1 x Door ajar TTL signal output, 5VDC output, 20mA - 12.8VDC battery charging
Memory
- 38,000 cardholders, each card holder has 24 bytes content - 45,000 swipe card records - 800 events
PCB Dimension Expansion
120mm x 120mm x 12mm 1 x RS485 serial port for expansion, software and hardware interface to other system
Holidays
100 Holiday dates
Timezone
- 80 x access control time zone - 1 x password time zone - 1 x electric Lock time zone - 1 x alarm time zone - 1 x door ajar time zone - 1 x request to exit time zone - 1 x twin card operation time zone All timezone can be assigned from Monday to Sunday and Holiday, 4 intervals per day, time zone can be selected globally or individually
Password
- User password, timezone control - Global password, key in the password through keypad reader open door - Duress password, open door but trigger alarm output
Communication
- Panel to hub, CAT 5 cable (max. 100 meters) - Panel to panel, daisy chain by CAT 5 cable (max. 100 meters)
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 4 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ No. of Panels Depends on IP address available Backup Battery Operating Voltage Operating Temperature Operating humidity
Wiegand Reader
ACX Reader
- 12VDC, 7AH backup battery, - provide at least 4 hours operation, excludes electric lock power consumption - 220V, 5A input in AC. - 12VDC, 3A output 0°to 65°C 0-95% relative humidity non-condensing - Communication: Wiegand - Green / Red LED control - Buzzer control - Reader in 6 wires connection - Max. cable length : 150m - Communication : RS485 - High Security scramble data encryption - 7 x LED color control - Buzzer Control - Interactive message display for ACX LCD reader - Reader in 4 wires connection - Max. cable length : 1,200m
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 5 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 3. System Deployment There are three ways to connect panels. All of the panels communicate in TCP/IP protocol with each other. CAT5 cable is used to connect the panel to the (LAN) Local Area Network or connect the panels in Daisy Chain. RS 485 protocol is no longer used for inter-panel communications so that the cost is reduced and the speed is increased. Multi-threading is also used to speed up concurrent operations. Pier to Pier Daisy Chain Pier to Pier + Daisy Chain
Pier to Pier
DATABASE and SOFTWARE
Local Area Network TCP/IP PANEL
TCP/IP
TCP/IP PANEL
.... PANEL
Daisy Chain
DATABASE and SOFTWARE
Local Area Network TCP/IP
....
TCP/IP PANEL
PANEL
PANEL
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 6 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________
Pier to Pier + Daisy Chain
DATABASE and SOFTWARE
Local Area Network TCP/IP
TCP/IP
.... PANEL
....
TCP/IP PANEL
PANEL
PANEL
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 7 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 4. Panel Layout
ACX 8901 Single Door TCP/IP Panel 120mm C2
C3
C4
C5
C2 : NO / NC / COM / PWR / GND (1) C3 : Door Ajar / NO / NC / COM (1) C4 : Door Sensor / GND / RTE / GND (1)
RJ45
- AUX IN - Tamper
RJ45
12VDC, 3ADC
C1 C6
For Emergency Door open Device
C7
AC / DC / Backup battery monitoring
C8
120mm
RS485 Port (for future use)
2 x Wiegand or ACX Scramble RS485 reader Power / Ground / D0 / D1 / ACK / Buzzer / RS485 T+ / RS485 T-
C10
C9
Start from the left is PIN 1 when face the terminal
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 8 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 5. Detailed Pin Assignment
8901 Single Door TCP/IP Controller Connector C1
Summary Power Input E-Lock Power (12V, 1.5A)
C2 E-Lock Output (Dry Contact)
C3
Door Alarm Output (Dry Contact) Door Ajar Output Door Sensor
C4 Release Button AUX INPUT C5 Panel Tamper
C6
C7
C8
RS485 Port (Custom use)
For Emergency Door Open Device
Power Status
PIN
Description
1
12VDC, 3ADC
2
Ground
1
Ground
2
Power
3
COM
4
NC
5
NO
1
COM
2
NC
3
NO
4
Normal is 0VDC, Door Ajar 5VDC, 200mA output
1
Door Sensor
2
Ground
3
Release button
4
Ground
1
IN#1
2
Ground
3
Tamper
4
Ground
1
RS485 (T+)
2
RS485 (T-)
3
RS485 (T+)
4
RS485 (T-)
1
Power Out (12VDC, 100mA)
2
Ground
3
Signal +
4
Signal -
1
DC Power
2
Backup Battery
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 9 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 3 A.C. Power
C9
C10
RJ45
OUT Reader
IN Reader
2 Ports TCP/IP Switch
4
Ground
1
Reader Power (200mA)
2
Ground
3
Data 0
4
Data 1
5
Green LED (ACK)
6
Buzzer
7
RS485 (T+) ACX RS485 reader only
8
RS485 (T-) ACX RS485 reader only
1
Reader Power (200mA)
2
Ground
3
Data 0
4
Data 1
5
Green LED (ACK)
6
Buzzer
7
RS485 (T+) ACX RS485 reader only
8
RS485 (T-) ACX RS485 reader only
1 2
Connect to TCP/IP swtich or next Panel
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 10 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 6. Panel Configuration Panel Address 1. Go to the IP Config folder under the Installation folder (Normally C:\Program Files (x86)\ACX\X.90 Access Control System\Set IP Config). Open the IP Configuration utility program.
2. Click “Scan” button.
3. Select the device and modify the IP Address or other parameters. Input the PWD and Click “Set” button to download configuration to the board.
Remark: The Default Key is 123456
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 11 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ 7. Sample Connection Circuits A. System
Daisy Chain
TCP/IP Hub
8901/8902 PANEL
TCP/IP
L A N
TCP/IP
Server
8901/8902 PANEL
8901/8902 PANEL
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 12 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ B. Reader Wire Color:
Reader: C9, C10
1. Red 2. Black 3. Green 4. White 5. Orange 6. Yellow 7. Purple 8. Grey
Reader Power Ground Data 0 Data 1 Green LED (ACK) Buzzer RS485 (T+) RS485 (T-)
1 2 3 4 5 6 7 8
Wiegand Reader
Wiegand Reader
1 2 3 4 5 6 7 8
ACX Scramble RS485 Reader (Improved Security)
Scramble RS 485 Reader
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 13 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ C. Electrical Lock Pin Assignment:
E-Lock: C2
1 2 3 4 5
Ground Power COM NC NO
+E-Lock -
Normally Closed with Power on Panel
5
4
3
2
1
+E-Lock -
Normally Open with Power on Panel
5
4
3
2
1
Normally Closed with External Power
E-Lock + -
External Power
External Ground
5
4
3
2
1
3
2
1
Normally Open with External Power
E-Lock + -
External Power
External Ground
5
4
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 14 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ D. Door Alarm (Dry Contact) Pin Assignment: Alarm: C3
1 2 3 4
COM NC NO Normal is 0VDC, Door Ajar 5VDC, 20mA output
External Power
-
External Ground
Alarm Device +
Normally Open with External Power
4
3
2 1
External Power
-
External Ground
Alarm Device +
Normally Closed with External Power
4
3
2
1
E. Door Ajar Output Pin Assignment: Door Ajar: C3
1 2 3 4
COM NC NO Normal is 0VDC, Door Ajar 5VDC, 20mA output
LED Panel Ground
Connect to LED indication
4
3
2 1
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 15 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ F. Door Sensor and Release Button Input Pin Assignment: Door Sensor and Release Button: C4
1 2 3 4
Door Sensor Ground Release button Ground
Door Sensor Release Button
Connect the Sensor Input
4
3
2
1
G. Panel Tamper Pin Assignment: Panel Tamper: C5
1 2 3 4
Door Sensor Ground Release button Ground
Normal is Close
Connect the Sensor Input
4
3
2
1
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 16 of 17
8901 Access Control Panel Installation Guide __________________________________________________________________________ H. Emergency Door Open Device Pin Assignment: Emergency Door Open: C7
1 2 3 4
Power Out (12VDC, 100mA) Ground Signal + Signal -
Pin Assignment for Key Switch
Pin 1 2 3 4
Install the ACX J1 key switch panel
6
5
4
3
2
5
1
6
Type
Function Wire Color Red (V-) Red LED Green (V-) Green VCC (12V) Black Key N.O Amber COM White (for Key and Tamper) Tamper N.O Brown
ACX J1
4 3 2 1 S- S+ GND 12V
C7 for 8901 C10 for 8902
Control Panel
_______________________________________________________________________________________________________________ Version C. 2014-05-21 Design . Innovations Page 17 of 17