Transcript
S300-2DQ-CB-H
HALSEY TAYLOR OWNERS MANUAL USES HFC-134A REFRIGERANT
33 SEE FIG. 4 1 THRU 8 SEE FIG. 5 11
9, 10
31
28 32
23
29
20
24
22 12
26
42 SEE FIG. 3 18 41
13
40 19
14
30
25 27
15, 16, 17
21
FIG. 1 PAGE 1
97435C (Rev. C - 11/00)
LEGEND/LEYENDA/LÉGENDE A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB OUT 1-1/2 IN. (38mm) FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-1/2" (38 mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS. EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E. CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38 mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES. B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO. EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU. C = 1-1/4 TRAP NOT FURNISHED PURGADOR DE 1¼ NO PROPORCIONADO SIPHON 1-1/4 NON FOURNI D = ELECTRICAL OUTLET LOCATION UBICACIÓN DE LA TOMA DE ELECTRICIDAD EMPLACEMENT DE LA PRISE DE COURANT
97435C (Rev. C - 11/00)
PAGE 2 E = INSURE PROPER VENTILATION BY MAINTAINING 4" (102mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL. ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 4" (102mm) (MÍN.) DE HOLGURA ENTRE LA REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 4" (102mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE MUR. F = POWER CORD 4' (1219mm) LONG CABLE ELÉCTRICO DE 4' (1219mm) PIE, DE LARGO CORDON DALIMENTATION 4' (1219mm) G = WALL SCREW HOLES AGUJEROS DE TORNILLOS DE PARED TROUS DE VIS DU MUR
FIG. 2
S300-2DQ-CB-H
S300-2DQ-CB-H
SERVICING THE HOT CONTROL AND FUSE ASSEMBLY 1. A temperature sensing non-resetable fuse in the wire is located approximately 3" (76mm) from the thermostat. The fuse is located under the retaining bracket (Item 3) in the groove on the heater element jacket (Item 4). 2. The thermostat must be used with a washer-spacer (Item 7) and be centered in the heater element jacket for proper temperature control. Locate the heater element jacket about 3/4" (19mm) above the bottom of the tank. 3. The heater element jacket must be fastened VERY TIGHTLY to the tank (45+/-10 inch/lbs. of torque on the mounting screw Item 9). Failure to TIGHTEN heater element jacket may cause rapid failure of the fuse assembly.
HOT TANK PARTS LIST ITEM NO.
PART. NO.
DESCRIPTION
1 2 3 4 5 6 7 8 9 10 11 12 13 14
22111C 22112C 22113C 30980C 31386C 31428C 50787C 70606C 70607C 70640C 70659C 70683C 70793C 31397C
Heater Clamping Bracket Heater Clamping Bracket (thrd) Retaining Bracket Heater Element & Jacket 115V Tank & Tube Assy Hot Control Assy Washer-Spacer Drain Plug Screw 1/4-20 x 3.00" HSHC Screw #8-18 x 5/16" HHTC Belleville Washer 1/4 Union 1/4 Elbow Hot Tank Assy 115V (Serv)
7
12
10 3
5
6
4
9 1 2
13
8
35
11
FIG. 3 ITEM 14
39
34
36
37
38
FIG. 4 ITEM 33 PAGE 3
97435C (Rev. C - 11/00)
S300-2DQ-CB-H ITEMIZED PARTS LIST ITEM NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
PARTNO. 45675C 40048C 40089C 10031C 40322C 60291C 61313C 100322740560 101486340560 601506551550 401505742830 70683C 192682851550 35786C 194243901550 31797C 31038C 35839C 66200C 66504C 101486931560 66521C 27985C 27989C 401486648410 401455643730 401474943730 401484743730 55832C 192668251550 15009C 55996C 40579C 40596C 40597C 51543C 33659000 70921C 92712C 21591C 30010C 22588C
DESCRIPTION Bubbler Body Button CP Nut - Cover CP Nut - Retaining Orifice Assy Screen SS Regulator Gasket - Black Gasket Drain Elbow Assy Basin Union - 1/4 Condenser Compressor Serv Pack (115V) Cover - Elect Sheild Cover - Relay (115V) OL/Relay (115V) Cold Control Drier - R134A Evaporator Assy Toe Plate Heat Exchanger Panel - Side (LH) PV Panel - Side (RH) PV Panel - Front PV Shelf - "S" Series Base - "S" Series Service Plate "S" Series Flow Regulator Assy Wiring Assy SD-CB Assy - Nipple Strainer Hot Valve Assy Shroud - Hot Valve Gooseneck - Hot Handle - Red Gasket - Body Nut - Mounting Kit - Hot valve Hot Tank Switch Brkt Hot Tank Switch Bracket - Hot tank Mtg.
WIRING DIAGRAM
This Drawing is merely for illustrating the components of the electrical system.
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.
PUSH BUTTON REGULATOR Stream Height Adjustment
1) Remove cover nut. 2) Lift off push button cap. 3) Turn exposed screw to change stream height. Clockwise adjustment will raise stream height and counter-clockwise adjustment will lower stream height.
To Replace Cartridge: a) Shut off water cooler. b) Remove cover nut and push button. c) Use spanner wrench to remove retaining nut. d) Lift out cartridge and bottom gasket. Insert replacement and gasket. e) To adjust stream height see note 3 above.
NUT - COVER
ORIFICE ASSY BUBBLER BODY
NUT-RETAINING
SCREEN SS GASKET-BLACK
FIG. 5
2222 CAMDEN COURT OAK BROOK, IL 60523 630.574.3500
PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.323.0620 POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE 1.800.323.0620
97435C (Rev. C - 11/00)
PAGE 4