Transcript
MCC
TM
Micro Commercial Components
S3A THRU S3M
omponents 20736 Marilla Street Chatsworth !"# $ % !"#
Features
•
Lead Free Finish/Rohs Compliant (Note1) ("P"Suffix designates Compliant. See ordering information) For Surface Mount Applications Low Thermal Resistance High Current Capability High Temp Soldering: 260°C for 10 Seconds At Terminals
• • • •
•
3 Amp Silicon Rectifier 50 to 1000 Volts
Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 MSL rating1
Maximum Ratings • • •
DO-214AB (SMC)
Operating Temperature: -55°C to +150°C Storage Temperature: -55°C to +150°C Maximum Thermal Resistance; 10°C/W Junction To Lead MCC Part Number
Device Marking
S3A S3B S3D S3G S3J S3K S3M
S3A S3B S3D S3G S3J S3K S3M
Maximum Recurrent Peak Reverse Voltage 50V 100V 200V 400V 600V 800V 1000V
Maximum RMS Voltage 35V 70V 140V 280V 420V 560V 700V
Maximum DC Blocking Voltage 50V 100V 200V 400V 600V 800V 1000V
Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward IF(AV) 3.0A Ta = 120°C Current Peak Forward Surge IFSM 100A 8.3ms, half sine Current Maximum VF IFM = 3.0A; Instantaneous 1.20V Forward Voltage TJ = 25°C* Maximum DC IR Reverse Current At TJ = 25°C 10µA Rated DC Blocking 250µA TJ = 125°C Voltage Typical Junction CJ 60pF Measured at Capacitance 1.0MHz, VR=4.0V *Pulse test: Pulse width 200 µsec, Duty cycle 2% Note:
G
H
D C A
E B
F DIMENSIONS
DIM A B C D E F G H
INCHES MIN .079 .108 .002 .006 .030 ..305 .260 .220
MM MIN 2.00 2.75 0.051 0.152 0.76 7.75 6.60 5.59
MAX .103 .128 .008 .012 .050 .320 .280 .245
MAX 2.62 3.25 0.203 0.305 1.27 8.13 7.11 6.22
NOTE
SUGGESTED SOLDER PAD LAYOUT 0.185
0.121”
0.060”
1. High Temperature Solder Exemptions Applied, see EU Directive Annex 7.
Revision: 4
www.mccsemi.com 1 of 4
2008/02/01
MCC
S3A thru S3M
TM
Micro Commercial Components
Figure 1 Typical Forward Characteristics 100
Figure 2 Forward Derating Curve
60
3.0
40 2.5
20 10
2.0
6 1.5
4
Amps
2
1.0
25°C Amps
1 .5 .6 .4
0
Single Phase, Half Wave 60Hz Resistive or Inductive Load 40
60
80
100
120
140
160
.2
°C
.1
Average Forward Rectified Current - Amperes versus Ambient Temperature - °C
.06 .04 .02 .01
.5
.9
.7
1.1
1.3
1.7
1.5
Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance
100 60 40 20 pF
10
TJ=25°C
6 4 2 1 .1
.2
.4
1 Volts
2
4
10
20
40
100
200
400
1000
Junction Capacitance - pF versus Reverse Voltage - Volts
Revision: 4
www.mccsemi.com 2 of 4
2008/02/01
MCC
S3A thru S3M
TM
Micro Commercial Components Figure 4 Typical Reverse Characteristics 1000 600 400
Figure 5 Peak Forward Surge Current 150
200
125
100
100
60 75 40
Amps
50
20 25
TA=125°C
µAmps 10
0 6
1
2
4
6
8 10
20
40
60 80 100
Cycles
4
Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles
2 1 .6 .4 TA=25°C
.2 .1
20
40
60
80
100
12 0
140
Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts
Revision: 4
www.mccsemi.com 3 of 4
2008/02/01
MCC
TM
Micro Commercial Components
Ordering Information Device
Packing
(Part Number)-TP
Tape&Reel;3Kpcs/Reel
***IMPORTANT NOTICE*** Micro Commercial Components Corp . reserves the right to make changes without further notice to any product herein to make corrections, modifications , enhancements , improvements , or other changes . Micro Commercial Components Corp . does not assume any liability arising out of the application or use of any product described herein; neither does it convey any license under its patent rights ,nor the rights of others . The user of products in such applications shall assume all risks of such use and will agree to hold Micro Commercial Components Corp . and all the companies whose products are represented on our website, harmless against all damages. ***APPLICATIONS DISCLAIMER*** Products offer by Micro Commercial Components Corp . are not intended for use in Medical, Aerospace or Military Applications.
www.mccsemi.com Revision: 4
4 of 4