Overview: This PACOM Wall Mount CCTV Power Supply provides 24VAC distributed via eight (8) PTC protected outputs for powering CCTV Cameras and other video accessories. Notes: Power On/Off Switch has been provided at the Bottom of the cabinet Caution: Always test for correct output voltage ( 24VAC) before connecting power to cameras or other equipment. Temporarily power up the unit and measure the AC output voltage to avoid damage to devices. Then disconnect power before connecting external devices. 1. Mount unit in the desired location (Space unit at least 100mm from any video monitors). Do not obstruct side air vents. Use L brackets provided for bottom fixing. 2. Unplug Green terminal connector blocks from their sockets for easy installation. 3. Tech Tip: All Cameras with similar power cable length should be grouped together on the same terminal block. 4. Connect cameras or other equipment power input cables to the screw terminals side by side in pairs. 5. Screw the terminals closed, making sure that there are no loose connections. Once this is done, insert the terminal block back into its correct slot. 6. Connect the unit’s power cord to a 240VAC outlet. Switch on power to the unit. 7. Front-panel LEDs should illuminate Green if the Channel is not being used and Blue if the channel or channels are being used. Red if the Channel has a short circuit on the output lines. 8. Test the output at the camera end of each power cable to be sure that the voltage is within range as specified by the Camera manufacturer. 9. Volt meter operational range 5V - 69.9V 10. Amp meter operational range 200mA -8Amp For current load > 8 Amps ,<9 Amps Amp Meter display will Flash the current value For current Load Greater than 9.00 Amps, the Amp Meter display will read OL= Over Load.
PAC-24WM0808(S84746) PAC-24WM0808(S84746)
Tri-Colour LED status indicator for each output: Green Open Circuit
Blue Closed Circuit < 120mA load
Red Short Circuit PTC Fuse tripped
CAUTION: To reduce the risks of electric shock do not open enclosure. There is no user serviceable parts inside. Refer servicing to qualified service personnel. Replace fuses with the same type and rating T1.5A/250V Wall Mount Mechanical Dimensions 280*231*83mm
Procedure for resetting PTC fuse: • Remove short in the circuit. • Switch off PSU switch for a period of 30 seconds, then switch back on and PTC fuse will reset automatically.
Specifications
11. Ry-NC is a normally closed relay contact.
2
3
PAC-24WM0808(S84746)
PAC-24WM0808(S84746)
Parallel Output Configuration By connecting more than 1 output in parallel the normal current availability can be doubled, tripled or even quadrupled
24VAC Cable Distance (meters) 5VA (208ma)
24 AWG 65m
10VA (417ma)
22 AWG 103m
24 AWG 32m
20VA (833ma)
24 AWG 16m
20 AWG 175m
Normal Current Limit X 2 18 AWG 260m
22 AWG 86m
20 18 AWG AWG 87m 137m
22 AWG 43m
20 AWG 44m
16 AWG 414m
16 AWG 218m
18 16 AWG AWG 69m 109m
14 AWG 348m
14 AWG 174m
12 AWG 276m
14 AWG 659m
12 AWG 1052m
Load
12 AWG 552m
Normal Current Limit X 3Load
Load
30VA (1.250ma)
40VA (1.667ma)
50VA (2.083ma)
24 AWG 10m
24 AWG 8m
24 AWG 6m
22 AWG 29m
22 AWG 21m
22 AWG 17m
20 AWG 30m
20 AWG 22m
20 AWG 18m
18 16 14 12 AWG AWG AWG AWG 46m 73m 116m 184m
18 AWG 34m
18 AWG 27m
16 AWG 55m
16 AWG 44m
12 AWG 138m
14 12 AWG AWG 69m 110m
75VA (3.125ma)
24 AWG 5m
22 20 18 AWG AWG AWG 7m 12m 18m
100VA (4.167ma)
24 AWG 3m
22 20 18 16 14 AWG AWG AWG AWG AWG 8m 9m 14m 22m 35m
16 AWG 29m
14 AWG 87m
14 AWG 46m
4
Normal Current Limit X 4
12 AWG 73m
Load
12 AWG 55m
5
PAC-24WM0808(S84746)
PAC-24WM0808(S84746)
Troubleshooting 1. Power does not turn on
• Check front panel leds and rear main fuse • Ensure power cord is firmly in its socket and the switch is in the on position • Ensure you have 240VAC supply to the Power Supply Unit
2. led’s are RED even
• To reset PTC , turn of power and wait for 30 sec, then restart unit though there is no short circuit
3. Voltage drop is large
• Use thicker guage wire
4. Camera case is hot
• Check that the correct voltage is supplied to the camera
5. Amp Meter display Flashes continously
• Power Supply load is approaching maximum current limit
6. Amp Meter display reads OL
• Power Supply unit has exceeded its maximum load capacity. Disconnect 1 or more devices until Amp Meter shows a reading less than the maximum capacity.