Transcript
SA1E-X Photoelectric Transparent Sensor Features • Sub-miniature photoelectric sensor • Quick response speed - 500μs • Long sensing range - up to 2m • Cable and M8 connector models • IP67 rated housing provides water and dust resistance • CE Marked, UL Listed • Other models in the SA1E Series include through-beam, polarized retro-reflective, background suppression, convergent, diffuse-reflective, and small-beam reflective
Specifications
Accessories
Coaxial Polarized Retro-reflective
Reflectors (used only for transparent-object sensing)
Voltage
12 to 24V DC (Operating range: 10 to 30V DC; reverse-polarity protected)
Item
Power Consumption
20mA maximum
Reflector
Sensing Range
2m (when using IAC-R9)
Detectable Object
Opaque, transparent and mirror-like objects
Response Time
500μs maximum
Sensitivity Adjustment
Adjustable using a potentiometer (approx. 240°)
Sensor Mounting Brackets
Light Source Element
Red LED
Item
Operation Mode
Light ON/Dark ON
Control Output
NPN/PNP open collector (30V DC, 100 mA maximum; short-circuit protection) Voltage drop: 2V maximum
LED Indicators
Operation LED: Yellow
Interference Prevention
Two units can be mounted close to each other
Degree of Protection
IP67 (IEC60529)
Extraneous Light Immunity (at receiver)
Sunlight: 10,000 lux maximum, Incandescent lamp: 5,000 lux maximum
Operating Temperature Operating Humidity
Insulation Resistance
Between live part and mounting bracket: 20MΩ minimum (500V DC Megger)
Dielectric Strength
Between live part and mounting bracket: 1,000V AC, 50/60Hz, 1 minute
Vibration Resistance
Damage limits: 10 to 55Hz, Amplitude 0.75mm, 20 cycles in each of 3 axes
Shock Resistance
Damage limits: 500m/s2, 10 shocks in each of 3 axes
Material
Housing: PBT, Lens: PMMA, Indicator cover: PC
Connection Method
Connector
55g* 20g
Cable
ø3.5mm, 3-core, 0.2 mm2, vinyl cabtyre cable
Connector
M8 connector (4-pin)
*Cable length: 2m (35g when the cable length is 1m and 120g when 5m)
IAC-R9
Small
IAC-R10
Extra-small
IAC-R11
For IAC-R9
IAC-L3
Vertical Mounting
SA9Z-K01
Horizontal Mounting
SA9Z-K02
Cover type
SA9Z-K03
Back Mounting
SA9Z-K04
Part Number
Main Unit Mounting Brackets
Connector Cable (for connector model) Number of Core Wires
4
35 to 85% RH (no condensation) –40 to +70°C (no freezing)
Cable
Reflector Mounting Bracket
–25 to +55°C (no freezing)
Storage Temperature
Weight (approx.)
Part Number Standard
Type and Length
Part Number
Straight, 2m
SA9Z-CM8K-4S2
Straight, 5m
SA9Z-CM8K-4S5
Right angle, 2m
SA9Z-CM8K-4L2
Right angle, 5m
SA9Z-CM8K-4L5
Air Blower Mounting Block Item
Part Number
Air Blower Mounting Block Notes 1 & 2
SA9Z-A02
Slits Item Vertical Slit Note 3
Slit Size
Part Number
0.5 mm × 18 mm
SA9Z-S06PN02
1.0 mm × 18 mm
SA9Z-S07PN02
2.0 mm × 18 mm
SA9Z-S08PN02
1. Two mounting screws (M3 × 20 mm sems screw), one M5 × 6 mm screw for plugging the air supply port, and one gasket (0.5 mm thick) are supplied. Air tube fitting and mounting bracket are not supplied and must be ordered separately (recommended mounting bracket: SA9Z-K01). 2. Material: Anodized aluminum 3. Horizontal or round slits cannot be used.
Part Numbers, Dimensions, Characteristics & Wiring on following page
Sensor Part Numbers
Red LED
With Sensitivity Adjustment
Coaxial Polarized Retro-reflective
Sensing Method
Sensing Range 2.0m (when using IAC-R9)
Part Number Operation Mode NPN Output PNP Output
Cable Length
Connection
Cable*
1.0m [100 mm] (when using IAC-R10)
Note: Reflector is not supplied and must be ordered separately. See characteristics diagrams below.
1.0m [100 mm] (when using IAC-R11)
Light ON
SA1E-XN1-2M
SA1E-XP1-2M
Dark ON
SA1E-XN2-2M
SA1E-XP2-2M
Light ON
SA1E-XN1C
SA1E-XP1C
Dark ON
SA1E-XN2C
SA1E-XP2C
2m
Connector
—
*Also available with 1 or 5m cables. Please contact IDEC for more details.
Dimensions Cable Model
Application Examples
Connector Model
10.8 4.5
ø3
.5
4.5 17.2
31.5 25.4
(coaxial)
19.5 3.4
ø5
Projector, Receiver (coaxial)
4.5 17.2
Transparent Film
31.5 25.4
.2
.2
0.9
10.8 0.9
19.5 3.4
ø5
Projector, Receiver
14.5 11.0
2.9
2.9
14.5
11.0
Transparent Case Packaging 2-M3
M8
6.3∗
2-M3
*The connector length is 18 mm when a right-angle connector cable (SA9Z-CM8K-4L ) is attached.
Characteristics Excess Gain
Lateral Displacement
100.0
Excess Gain
Lateral Displacement Y (mm)
30
10.0
IAC-R9 IAC-R9形
IAC-R11形 IAC-R11 1.0
IAC-R10形 IAC-R10 0
0.5
1
1.5
2
2.5
3
Sensing Distance X (m)
3.5
4
Angle
20
0
Wafer Displacement
-10 -20 -30
0
0.5
1
1.5
2
2.5
Sensing Distance X (m)
3
3.5
4
40
30 IAC-R9
IAC-R11
IAC-R10
10
Light Beam Diameter (mm)
35
20 Reflector Angle
IAC-R9
IAC-R10
Light Beam Diameter
40
0 -10 -20 -30 -40
IAC-R11
10
0
0.5
1
1.5
2
2.5
Sensing Distance X (m)
3
3.5
4
30 25 20 15 10 5 0
0
0.2
0.4
0.6
0.8 1 1.2 Distance (m)
1.4
1.6
1.8
2
Output Circuit Wiring PNP Output Type Brown (1) +V Load Black (4) OUT Blue (3) 0V
Connector Pin Layout 12 to 24V DC
(OUT)
(0V)
(NC)
(+V)
Main Circuit
Main Circuit
NPN Output Type
Brown (1) +V Black (4) OUT Blue (3) 0V
12 to 24V DC
Load
Connector Pin Layout (OUT)
(0V)
(NC)
(+V)
IDEC Corporation • 1175 Elko Drive • Sunnyvale, CA 94089 • 800-262-IDEC (4332) • Fax: 408-745-5258 • www.IDEC.com/usa ©2010 IDEC Corporation. All Rights Reserved. Catalog No. SA9Y-DS300-0 06/10 10K