Preview only show first 10 pages with watermark. For full document please download

Sa2-01b_sa2-02b_datasheet

   EMBED


Share

Transcript

SA2-01B, SA2-02B Switching actuator 1 and 2 fold  Designed for potentialless contact switching of appliances and loads.  SA2-01B contains 1 relay with potentialless contact with max. load 16A/4000 VA/AC1.  SA2-02B contains 2 relays with potentialless contacts with max. load 8A/2000 VA/AC1.  Output contacts are separately controllable and addressable.  LED on front panel signals output contact status.  SA2-01B, SA2-02B are designed for mounting into installation box.  SA2 is normally supplied in the option AgSnO2 contact material, the order can be supplied with contact Agni (use contacts page loads see Table 58). SA2-01B 1 TI SA2-02B 2 RO/AC EAN codes SA2-01B 8595188131162 1 TI TECHNICAL PARAMETERS B SA2-01B SA2-02B Yes, input for external thermo sensor TC, TZ -20 .. +100°C; 0.5°C from range / -4 °F to +212 °F / 32.9 °F from range I N P U T S Temperature measuring: Scope and accuracy of tem. meas.: EAN codes 1 R0/AC SA2-02B 8595188131186 Connection SA2-01B O U T P U T S Numbers and configuration: Switching voltage: Switched load: Surge current: Insulation voltage between outputs and built-in circuits: Insulation voltage between relay outputs RE1-RE2: Minimal switching current: Switching frequency/no load: Switching frequency/rated load: Mechanical lifetime: Electrical lifetime for AC1: Output indication: 1 x SPST-NO contact 16 A/AC1 2 x SPST-NO contact 8 A/AC1 250 V AC1, 24 V DC 4000 VA/AC1, 384 W/DC 2000 VA/AC1, 192 W/DC 30 A/<3s CIB + CIB Thermo sensor TC/TZ 3.75kV, SELV by EN 60950 x 1000 V AC 100 mA -1 1200 min -1 6 min 7 3 x 10 5 0.7 x 10 red LED 2x red LED C O M M U N I C A T I O N CIB Installation BUS: P O W E R S U P P L Y 27 V DC/40 mA 27 V DC/60 mA green LED RUN Supply voltage/rated current: Unit status indication: AC 230V L N C O N N E C T I O N Connection SA2-02B 0.5 - 1 mm2 (AWG 16) 2x conductors CY, section 2.5 mm2 (AWG 14) 4x conductors CY, 2.5 mm2 (AWG 14) Data terminals: Power outputs: CIB + CIB Thermo sensor TC/TZ O P E R A T I N G Operating temperature: Storage temperature: Protection degree: Control device purpose: Control device construction: C O N D I T I O N S -20 .. +55 °C / -4 °F to +131 °F -30 .. +70 °C / -22 °F to +158 °F Characteristics of automatic operation: Heat and fire resistance category: Anti-stroke category (immunity): Rated impulse voltage: Overvoltage category: Pollution degree: Operating position: Installation: D I M E N S I O N S Dimensions: Weight: A N D IP 30 operative control device individual control device 1.B.E FR-0 class 2 2.5 kV II. 2 any into installation box W E I G H T 49 x 49 x 21 mm / 1.9” x 1.9” x 0.8” 43 g/ 1.5 oz. 63g/ 2.2 oz. AC 230V L N 35