Preview only show first 10 pages with watermark. For full document please download

Safety Control

   EMBED


Share

Transcript

Safety Overview Selection Guide........................................... 394 Safety Relay HR1S-AC ............................... 395 Safety Relay HR1S-AF................................ 398 XW Series E-Stops Safety Relay HR1S-DM............................... 401 Safety Relay HR1S-ATE............................... 403 Safety Relay HR2S-301............................... 406 Safety Relay HR2S-332N............................ 411 FS1A Multi-function Safety Relay.............. 416 Interlock Switches Control Enabling Switches Safety Safety Control Light Curtains AS-Interface Safety at Work www.IDEC.com/safety Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg. 933 Safety Control Selection Guide XW Series E-Stops Overview Selection Guide Single Function Safety Relay Single Function Safety Relay Multi-function Safety Relay HR1S HR2S FS1A Page 395 406 416 Performance Level PLe PLe PLe 3/4 3/4 4 1NO/1NC, 2NC, 2NO/3NO (time delay) 3NO/1NC, 3NO/3NO (time delay) /2NC (Aux.) 4NO Series Appearance Contact Configuration AS-Interface Safety at Work Light Curtains Safety Control Enabling Switches Interlock Switches Safety Category 394 www.IDEC.com Safety Control HR1S-AC Safety Relay HR1S-AC Overview Key features: Part Numbers Dimensions (mm) Integrated Terminal Block HR1S-AC5121P Removable Terminal Block A1 13 23 33 –10 to 55°C (no freezing) Degree of Protection Terminal: IP20, Housing: IP40 Rated Power Voltage 24V AC (–20 to +10%) 50/60 Hz 24V DC (±20%) Power Consumption AC: 2.2 VA (24V AC) maximum DC: 1.2W (24V DC) maximum Overcurrent Protection Electronic Control Circuit Voltage 24V Performance Level (PL) e (EN ISO 13849-1) Safety Category 3 (EN 954-1) Safety Integrity Level (SIL) 3 (EN 62061) Response Time 100ms maximum Input Synchronization Time Unlimited Overvoltage Category III Pollution Degree 2 Rated Insulation Voltage 300V A1 A2 14 24 34 Y43 Y44 22.5 22.5 14 24 Y1 Y2 33 Y2 114 A1 14 24 34 114 LED Indicator  A2 Y43 Y44 • A1/A2 Fuse: Turns on when power circuit is normal. Turns off when power is interrupted or the electronic fuse blows. • K1: Turns on when K1 relay operates. Auxiliary Contact 1NO (transistor, PNP) AC-15 C300: Ue= 240VAC, Ie=0.75A DC-13 Ue=24VDC, Ie=2A Transistor Circuit 24V/20mA Minimum Applicable Load 17V/10mA (initial value) Rated Current Safety circuit output total: 10.5A maximum Wire Size HR1S-AC5121: 1 × 2.5mm2, 2 × 0.75mm2 maximum HR1S-AC5121P: 1 × 2.5mm2, 2 × 1.5mm2 maximum Weight 160g AS-Interface Safety at Work 1200 operations/h maximum The HR1S-AC5121P terminal block can be removed and installed as shown, allowing for easy installation and replacement of modules. Light Curtains 3NO Safety Control • K2: Turns on when K2 relay operates. Instantaneous (Stop Cat 0) Operation Frequency 23 Y1 Enabling Switches Operating Temperature Output Contact Ratings 13 24 99 Specifications Safety Circuit A1 14 A1/A2 A1/A2 Fuse Fuse K1/K2 K1/K2 99 Terminal Style HR1S-AC5121 Terminal Arrangement Interlock Switches Part Number Safety Outputs XW Series E-Stops • 1NC or 2NC safety input type, such as E-Stops or Interlock Switches • EN ISO 13849-1 PLe, Safety Cat 3 compliant, and EN 62061 SIL 3 • Fault diagnosis function with dual safety circuits. • Internal relay operations can be moni­tored with LED Indicator. • Finger-safe protection • 22.5mm wide, 35mm DIN rail mounting • UL listed, CSA certified, TÜV NORD approved Use a 4A fuse (Type gL) for power fuse protection. Use a 4A (Type gL) or a 6A fast blow fuse for output fuse protection 800-262-IDEC (4332) • USA & Canada 395 Safety Control HR1S-AC Overview HR1S-AC Wiring Diagram Safety Category 3 Example Circuit (using an emergency stop switch with 2NC contacts) F1 Fuse: 4A gL L1 (+) (3) ESC: S1: S2: F1: External Start Condition Emergency Stop Switch Start Switch Protection fuse for the power of safety relay module K4, 5: Safety contactor S2 K4 K5 S1 XW Series E-Stops (4) A1 Y1 HR1S-AC + T ESC Y2 LOGIC K1/K2 A1/A2 – K1 +24V DC 13 23 K1 K4 K4 K4 K2 K5 K5 K5 14 24 K4 Interlock Switches Y43 34 Y44 K5 N (–) (1) (2) (1) Three safety outputs (2) One transistor output (3) See the specifications for maximum fuse size (4) Jumper for terminal Y1-Y2 (for automatic start) Safety Category 3 Example Circuit (using an emergency stop switch with 2NC contacts) ESC: S1: S2: F1: Exernal Start Condition Emergency Stop Switch Start Switch Protection fuse for the power of safety relay module F2 to F4: Protection fuse for the output of safety relay module L1 (+) F1 (3) F2 (3) Fuses: 4A (gL) Enabling Switches F3 (3) F4 (3) S2 S1 ESC +24V DC (4) A1 Y1 Y2 HR1S-AC + T LOGIC K1/K2 A1/A2 – 13 23 33 Y43 24 34 Y44 Fuses: 4A (gL) or 6A fast blow type K1 K2 K1 K2 A2 14 N (–) (1) (2) (1) Three safety outputs (2) One transistor output (3) See the specifications for maximum fuse size Output Contact Electrical Life Operating Current × 0.1A Light Curtains 100 AS-Interface Safety at Work The Safety Category is achieved by the entire control system. Take any connected safety equipment and wiring into consideration. K2 A2 Safety Control 33 AC15: 230V DC13: 24V 10 AC1: 230V DC1: 24V 1 104 396 105 Operations 106 www.IDEC.com 107 Safety Control HR1S-AC HR1S-AC Safety Relay Module Operation Chart When Using a Start Switch Emergency Stop not Operated Overview Power ON Emergency Stop Operated Emergency Stop Switch A1 (NC1) Emergency Stop Switch A2 (NC2) Start Switch Operated ON OFF XW Series E-Stops Feedback Circuit with Start Switch (Y1-Y2) Output 13-14 (NO Contact) Output 23-24 (NO Contact) Output 33-34 (NO Contact) Contact Status ON Interlock Switches Transistor Output Y43-Y44 (NO Contact) OFF When Not Using a Start Switch Power ON Emergency Stop not Operated OFF Emergency Stop Operated Enabling Switches Emergency Stop Switch A1 (NC1) Emergency Stop Switch A2 (NC2) Y1-Y2 Jumper Output 13-14 (NO Contact) Output 23-24 (NO Contact) Safety Control Output 33-34 (NO Contact) Transistor Output Y43-Y44 (NO Contact) Contact Status ON OFF Light Curtains AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 397 Safety Control HR1S-AF Key features: • 2NC safety input type, such as E-Stops or Interlock Switches • EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3 • Welding detection of start switch • Fault diagnosis function with dual safety circuits • Internal relay operations can be moni­tored with LED Indicator. • Finger-safe protection • 22.5mm wide, 35mm DIN rail mounting • UL listed, CSA certified, TÜV NORD approved AS-Interface Safety at Work Light Curtains Safety Control Enabling Switches Interlock Switches Part Numbers Dimensions (mm) Part Number Terminal Style HR1S-AF5130B Integrated Terminal Block HR1S-AF5130PB Removable Terminal Block A1/A2 Fuse K1 K2 Specifications Operating Temperature –25 to +55°C (no freezing) Degree of Protection Terminal: IP20, Housing: IP40 Rated Power Voltage 24V AC (–15 to +10%) 50/60 Hz 24V DC (–15 to +10%) Power Consumption 5 VA maximum (24V AC) 2.5W maximum (24V DC) Overcurrent Protection Electronic (Note) Control Circuit Voltage 24V Performance Level (PL) e (EN ISO 13849-1) Safety Category 4 (EN ISO 13849-1) Safety Integrity Level (SIL) 3 (EN 62061) Response Time When S11-S12, S21-S22 are interrupted: 20 ms maximum When power is interrupted: 60 ms maximum Input Synchronization Time Unlimited Overvoltage Category III Pollution Degree 2 Rated Insulation Voltage 300V Safety Outputs 3NO Output Contact Ratings Instantaneous (Stop Cat 0) Safety Circuit Terminal Arrangement AC-15 C300: Ue= 240VAC, Ie=0.75A DC-13 Ue=24VDC, Ie=2A Minimum Applicable Load 22.5 99 XW Series E-Stops Overview Safety Relay HR1S-AF 114 LED Indicator • A1/A2 Fuse: Turns on when power circuit is normal. Turns off when power is interrupted or the electronic fuse blows. • K1: Turns on when K1 relay operates. • K2: Turns on when K2 relay operates. 17V/10mA (initial value) Operation Frequency 1200 operations/h maximum Rated Current Safety circuit output total: 18A maximum Each safety circuit output: 6A maximum Wire Size HR1S-AF5130B: 1 × 2.5 mm2, 2 × 0.75 mm2 maximum HR1S-AF5130PB: 1 × 2.5 mm2, 2 × 1.5 mm2 maximum Weight 250g The HR1S-AF5130PB terminal block can be removed and installed as shown, allowing for easy installation and replacement of modules. Note: Short-circuit of S11 and S21 activates the overcurrent protection circuit, interrupting the power supply. The safety output turns off. Normal status is restored when the short-circuit is removed. Use a 4A fuse (Type gL) for power line protection. Use a 4A fuse (Type gL) or a 6A fast blow fuse for output line protection. 398 www.IDEC.com Safety Control HR1S-AF Wiring Diagram Safety Category 4 Example Circuit (using an emergency stop switch) L (+) When not using a start switch (automatic start) The Safety Category is achieved by the entire control system. Take any connected safety equipment and wiring into consideration. A1 S33 S34 S39 13 23 Overview HR1S-AF 33 F1 (Fuse: 4A gL) 24V AC/DC When not monitoring the start switch (welding of start switch cannot be detected) K3 K4 Start Switch 14 14 A1 S33 XW Series E-Stops S2 13 S2 13 Start Switch S34 S39 13 23 33 (1) ESC When monitoring S2 A1 S33 When not monitoring S2 S34 S39 13 23 When monitoring the start switch 33 (detecting the OFF status of start switch) K1 S2 13 LOGIC 14 K2 A1 A2 S11 S12 S21 S1 11 21 Emergency 12 Stop Switch 22 S22 14 24 S33 Start Switch S34 S39 13 23 Interlock Switches HR1S-AF 33 34 When not monitoring the start switch (welding of start switch cannot be detected) K3 K4 S11 S12 S21 S22 Enabling Switches A2 N (–) S1 22 Input B 21 Safety Output 3 Circuits 14 Input A ESC: External Start Condition F1: Protection fuse for the power of safety relay module K3, 4: Safety contactor 13 (1) = Start Switch Monitor S2 Safety Category 3 Example Circuit (using multiple emergency stop switches) L (+) F1 (Fuse: 4A gL) Safety Control Safety Guard Open 24V AC/DC K3 S4 K4 ESC A1 ESC: External Start Condition F1: Protection fuse for the power of safety relay module K3, 4: Safety contactor Start Switch When monitoring S4 S33 When not monitoring S4 S34 S39 23 33 14 24 34 Light Curtains 13 K1 HR1S-AF LOGIC K2 A2 S12 S21 21 12 S2 11 22 12 22 S3 11 21 12 22 21 S22 Emergency Stop Switch 1 Emergency Stop Switch 2 K3 AS-Interface Safety at Work N (–) S11 S1 11 K4 Emergency Stop Switch 3 800-262-IDEC (4332) • USA & Canada 399 Safety Control HR1S-AF Overview HR1S-AF Operation Chart When Using the Emergency Stop Switch Power ON Emergency Stop Switch 0 S11-S12 NC1 Start Switch Operation Emergency Stop Switch Operation 1 XW Series E-Stops Emergency Stop Switch S21-S22 NC2 Start Switch S33-S34 NO ➀ Start Switch S33-S39 NO ➁ j When monitoring the start switch (detecting the OFF status of start switch) k When not monitoring the start switch (contact welding of start switch can­not be detected) Output 13-14(NO Contact) Interlock Switches Output 23-24(NO Contact) Output 33-34(NO Contact) When not Using the Safety Guard (Automatic Start) Input A (S21-S22) Enabling Switches Switch S1 Operated Power ON 0 Safety Guard Open Switch S2 Operated Safety Guard Open Safety Guard Closed 1 Input B (S21-S22) S33-S39 (short-circuit) Output 13-14 (NO contact) Safety Control Output 23-24 (NO contact) Output 33-34 (NO contact) t = 0 to ∞ Output Contact Electrical Life 100 AC1: 230V AS-Interface Safety at Work Operating Current × 0.1A Light Curtains AC15: 230V DC1: 24V DC13: 24V 10 1 104 400 105 Operations 106 107 www.IDEC.com Safety Control HR1S-DM Safety Relay HR1S-DM HR1S-DMB( )P HR1S-DMB Part Numbers Specifications Terminal Style HR1S-DMB1132 Integrated Terminal Block Input HR1S-DMB1132P Removable Terminal Block HR1S-DME1132 Integrated Terminal Block HR1S-DME1132P Removable Terminal Block 2 6 Terminal Arrangement HR1S-DMB S11 S12 S13 23 A1 Y1 Y2 13 99 S11 S12 S13 23 A1 Y1 Y2 13 22.5 A2 Y34 Y44 14 114 S21 S22 S23 24 HR1S-DMB1132 Rated Power Voltage 24V DC (–20 to +20%) Power Consumption HR1S-DMB: 2.5W maximum (24V DC) HR1S-DME: 3.5W maximum (24V DC) Overcurrent Protection Electronic Control Circuit Voltage 24V DC Performance Level (PL) e (EN ISO 13849-1) Safety Category 4 (EN ISO 13849-1) Safety Integrity Level (SIL) 3 (EN 62061) Response Time 20 ms maximum Input Synchronization Time 500ms max Overvoltage Category III Pollution Degree 2 Rated Insulation Voltage 300V Maximum Input Resistance 100Ω (per input point) No. of Outputs HR1S-DMB1132P Terminal Arrangement HR1S-DME 2NO (transistor PNP) AC-15 C300: Ue= 240VAC, Ie=0.75A DC-13 Ue= 24V DC, Ie= 1.5A Transistor Circuit 24V/20 mA Minimum Applicable Load 17V/10 mA (initial value) Operation Frequency 1200 operations/hour maximum Rated Current Output total 12A maximum Wire Size 0.14 to 2.5 mm2 Weight HR1S-DMB: 180g HR1S-DME: 250g 800-262-IDEC (4332) • USA & Canada AS-Interface Safety at Work HR1S-DME1132P 2NO Auxilliary Contact Safety Circuit Output Contact Ratings 114 HR1S-DME1132 Safety Circuit Light Curtains 99 Dimensions (mm) HR1S-DME Terminal: IP20, Housing: IP40 Safety Control A2 Y34 Y44 14 S21 S22 S23 24 –10 to 55°C (no freezing) Degree of Protection Enabling Switches Dimensions (mm) HR1S-DMB Operating Temperature Interlock Switches Part Number 45 HR1S-DME XW Series E-Stops • 1NO-1NC safety input type, such as magnetic coded safety switches • Fault diagnosis function with dual safety circuits. • Internal relay operations can be moni­tored with LED Indicator. • Finger-safe protection • 22.5 or 45mm wide, 35mm DIN rail mounting • EN ISO 13849-1 PLe, Safety Cat 4 compliant, and EN 62061 SIL 3 • UL listed, CSA certified, TÜV NORD approved Overview Key features: Use a 4A fuse (Type gL) for power fuse protection. Use a 4A (Type gL) or a 6A fast blow fuse for output fuse protection. 401 Safety Control HR1S-DM Causes of Fault LED Indication LED2: Fault • Power A1/A2: Turns on when power circuit is normal. Turns off when power is interrupted or the electronic fuse blows. • Fault: Turns on when the HR1S fails (see failure causes on page 694). • K1/K2: Turns on when K1/K2 relays operate. • Power A1/A2: Turns on when power circuit is normal. Turns off when power is interrupted or the electronic fuse blows. • Fault: Turns on when the HR1S fails (see failure causes on page 694) • K1/K2: Turns on when K1/K2 relays operate. • S13: NO contact of non-contact interlock switch 1 • S12: NC contact of non-contact interlock switch 1 • S23: NO contact of non-contact interlock switch 2 • S22: NC contact of non-contact interlock switch 2 • S33: NO contact of non-contact interlock switch 3 • S32: NC contact of non-contact interlock switch 3 • S43: NO contact of non-contact interlock switch 4 • S42: NC contact of non-contact interlock switch 4 • S53: NO contact of non-contact interlock switch 5 • S52: NC contact of non-contact interlock switch 5 • S63: NO contact of non-contact interlock switch 6 • S62: NC contact of non-contact interlock switch 6 Internal Fault External Fault Short circuit of the +24V power supply and input terminal Remove the short circuit and reboot. External Fault Short-circuit of the non-contact interlock switch wiring Correct the wiring of the non-contact interlock switch and reboot. Synchronization for the NO contact and NC con­tact of the non-contact interlock switch (HS7A) is 0.5 seconds or longer. Open and close the door again. Fault of the noncontact interlock switch (HS7A) Replace the noncontact interlock switch. N O h itc w tS ar St G (N uar on d 2 -c on Op e G tac n (N uar t In on d 2 ter lo -c on Clo ck Sw ta se ct d itc In h te 2 rlo D ec k Er ac Sw ro tu r itc at ed h 2 ) Ac tu at ed ) ed at tu Ac 2 h itc Sw k (N G ua on rd 2 -c on Clo ta se ct d In te rlo c s C om G pl et (N uar ed on d 1 -c C on lo ta se ct d In te rlo ck Sw ag di lf- Po w er no O si N itc h 1 Ac tu at ed ) HR1S-DM Operation Chart When Using the Emergency Stop Switch Se Safety Control Measures Replace the safety relay module. The HR1S-DM terminal block can be removed and installed as shown, allowing for easy installation and replacement of modules. Non-contact Interlock Switch 1 (S11-S12) Non-contact Interlock Switch 2 (S21-S22) Light Curtains Fault Cause Fault of the internal circuit Synchronization time excess of switch con­tact input Non-contact Interlock Switch 1 (S11-S13) Non-contact Interlock Switch 2 (S21-S23) Start Switch (Y1-Y2) Transistor Output Y34 (Fault) Transistor Output Y44 (K1/K2) AS-Interface Safety at Work Fault Type HR1S-DME ) Enabling Switches Interlock Switches XW Series E-Stops Overview LED Indicator HR1S-DMB Safety Output 13-14/23-24 (NO) 2 sec Contact Status of Non-contact Interlock Switch < 0.5 sec < 0.5 sec ON (0) OFF (1) 402 www.IDEC.com Safety Control HR1S-ATE Safety Relay HR1S-ATE Overview Key features: Part Numbers Part Number XW Series E-Stops • EN ISO 13849-1 performance level e, safety category 4 compliant, and EN 62061 safety integrity level 3 • Integrated and removable teminal styles available • Compact design: 45 mm in width • Time delay outputs: 3NO • Auxiliary output enables power supply monitoring, inputs (2 channels), and a time delay output • Environmentally friendly, RoHs directive compliant • UL Listed, CSA certified, TÜV NORD approved Specifications Terminal Style Integrated Terminal Block HR1S-ATE5110P Removable Terminal Block Applicable Standards for Use 35 3 (EN 62061) 0, 1 (EN 60204-1) (Note) –10 to +55ºC (no freezing) 30 to 85% RH (no condensation) 4 kV (IEC 60947-5-1) 150 m/s2, 11m sec, 3 shocks in each 3 axes 10 to 60 Hz, amplitude 0.35 mm 60 to 150 Hz, acceleration 50 m/s2 Terminal: IP20 Enclosure: IP40 24V AC –20% +10% 24V DC –20% +20% 24V AC: 8 VA max. 24V DC: 4W max. Built-in, electronic 17V DC / 10 mA (initial value) ON to OFF: 20 ms max. (instantaneous output) III 2 300V Ac 2NO 3NO None 4 C300 (230V AC / Ie=0.75A) 24V DC / Ie=1A C300 (230V AC/ Ie=0.75A) 24V DC / Ie=1A 0, 0.5, 1, 2, 4, 6, 8, 10, 15, 20, 25, 30 sec. 24V DC / 20 mA (PNP) 10,000,000 operations See page XX Total output: 8A max. 1 output 4A max. Single wire: 0.2 to 2.5 mm2 max. (24~14 AWG) Multiple wires: 0.14 to 0.75 mm2 max. Single wire: 0.2 to 2.5 mm2 max.(24~14 AWG) Multiple wires: 0.2 to 1.5 mm2 max. 280g Degree of Protection Rated Voltage 35 99 HR1S-ATE5110P Removable Terminal Type 45 114 LED Indicator A1/A2 Fuse A1/A2 Fuse: Turns on when power circuit is normal. Input A S12 Input A S12: Turns on when S11–S12 is closed. Input B S22 Input B S22: Turns on when S21–S22 is closed. Stop 1 Stop1: Turns on when the time-delay output circuits 57-58, 67-68, and 77-78 are closed. Power Consumption Overcurrent Protection Minimal Applicable Load Response Time Overvoltage Category Pollution Degree Rated Insulation Voltage Safety Circuit Time-delay Circuit No of Outputs Auxilliary Contact Circuit Transistor AC15 Safety Circuit DC13 Output AC15 Contact Time-delay DC13 Ratings Circuit Preset Time Auxilliary Circuit Mechanical Durability Electrical Durability Rated Current Wire Size Weight (approx.) Note: Safety output contact Time-delay output contact Stop category 0 Stop category 1 HR1S-ATE5110 HR1S-ATE5110P Use a 4A fuse (Type gG) for power protection.Use a 6A fuse (Type gG) for safety output protection. Use a 4A fuse (Type gG) for time-delay output and auxiliary output protection. 800-262-IDEC (4332) • USA & Canada 403 AS-Interface Safety at Work 4 (EN ISO 13849-1) Safety Integrity Level (SIL) Stop Category Operating Temperature Relative Humidity Impulse Withstand Voltage Shock Resistance Light Curtains Safety Category Safety Control e (EN ISO 13849-1) Vibration Resistance 45 114 Performance level (PL) Enabling Switches 99 Dimensions (mm) HR1S-ATE5110 Integrated Terminal Type EN 60204-1: 2007, EN 60947-1: 2007, EN 60947-5-1:2004, EN 61000-6-2: 2005 EN 61000-6-4: 2007, EN 62061: 2005 EN ISO 13849-1: 2008, EN ISO 13849-2: 2008 EN 60204-1: 2006 EN ISO 13850: 2008 Interlock Switches HR1S-ATE5110 Applicable Standards Safety Control HR1S-ATE Overview HR1S-ATE Wiring Diagram Safety Category 4 (3) Circuit (using an emergency stop switch) (Note) Power ON Emergency Stop Switch 0 S11-S12 NC1 Start Switch Operation Emergency Stop Switch Operation 1 When not monitoring the start switch (Y3-Y4 short-circuited) (automatic start when S33-Y2 is short-circuited) Emergency Stop Switch S21-S22 NC2 XW Series E-Stops Safety category is achieved by the entire control system. Take the connected safety equipment and wiring into consideration. HR1S-ATE Start Switch S33-S34 NO ➀ Start Switch S33-S39 NO ➁ When monitoring the start switch Output 13-14(NO Contact) (Y3-Y5 short-circuited) HR1S-ATE Interlock Switches Output 23-24(NO Contact) Output 33-34(NO Contact) 1. When monitoring the start switch, starts when switched off (default setting/recommended) 2. When monitoring the start switch, starts when switched on 3. Outputs must be fused (see the instruction manual for maximum fuse size) 4. To PLC, etc. Note: When using off-delay output, safety category becomes 3. S1 = Emergency stop switch with 2 NC contacts (recommended) S2 = Start switch ESC = External start conditions Y1 (S33) – Y2 = Feedback loop Emergency stop switch - Input 1 channel Emergency stop switch - Input 2 channels When not detecting short-circuit(B1-S12 short-circuit not detected) HR1S-ATE HR1S-ATE Safety Category 3 Example Circuit (using multiple emergency stop switches) Door Cover L1 (+) Read instructions before configuring circuits. F1 Safety Control S5 S1 52 A2(+) 41 51 A1(–)  22 1 S2 HS5E-D4001 Interlock Switch with Solenoid S3 XW1E-BV402 Emergency stop switch A1 S21 S11 B1 21 11 22 12 21 11 22 12 S12 +24V S22 13 23 HR1S-ATE 57 67 77 Y+ 58 68 78 Y88 Y89 Y90 Y91 Time (s) K2 K1 HS5E-D4001 Interlock Switch with Solenoid XW1E-BV402 Emergency Stop Switch Start Switch (HW series momentary) Unlocking Enabling Switch Limit Switch, etc. External Start Condition Contactor (forced guided type) Fuse 4A (gG) Operations of Emergency stop switch (Stop) Press emergency stop switch → Safety output OFF → Machine stops (Reboot) Emergency stop switch reset → Safety relay module start switch ON → Safety output ON → Machine starts 2 S6 S1: S2, 3: S4: S5: S6: ESC: K5 to 8: F1: Operations of Interlock Switch with Solenoid (Stop) Machine stops → Unlocking enabling switch ON → Safety output OFF → Door cover released (Start) Door cover closed → Safety relay module start switch ON → Safety output ON → Machine starts 21 11 Light Curtains 2 42 12 HS9Z-A51 Actuator 1 Timer 2 T LOGIC Timer 1 Enabling Switches When not detecting short-circuit (All failures such as short-circuit of emergency stop switch wiring not detected) K1 K3 K2 K4 A2 S33 S4 K3 K4 K4 Y1 Y2 Y3 Y4 Y5 ESC K5 14 24 K5 K6 K6 K7 K8 N (–) 404 www.IDEC.com K7 K8 (Stop1) K2 (S22) K1 (S12) AS-Interface Safety at Work K2 K3 (A1/A2) K1 External Output Circuit Safety Control HR1S-ATE Operation Chart Start Output Contact Electrical Life Emergency Stop Not Operated (Safety Circuit, Time-delay Circuit, Auxilliary Circuit) Emergency Stop Operated DC13: 24V (<0,1Hz) Emergency Stop Switch (NC1) Transistor Output Y89 (S12) ➀ Emergency Stop Switch (NC2) Transistor Output Y90 (S22) Start Switch Start Switch ➁ ➁ tmax.= 75ms∗ When monitoring the start switch, with Y3-Y4 jumpered ∗When using without start switch, the input synchronization time should be 75 ms max. DC1: 24V AC15: 230V AC1: 230V XW Series E-Stops Without Start Switch Emergency Stop Switch (NC2 or NC1) Transistor Output Y89 (S12) ➀ When monitoring the start switch, with Y3-Y5 jumpered (default setting/recommended) Operating Current × 0.1A With Start Switch Overview Power ON HR1S-ATE Operations Emergency Stop Switch (NC1 or NC2) Transistor Output Y90 (S22) Start Switch ➂ ➂ Without start switch, with Y3-Y4 and S33-Y1 jumpered Output External Start Conditions Output 13-14 (NO) Output 23-24 (NO) Output 67-68 (NO) Output 77-78 (NO) Operation ON Interlock Switches Output 57-58 (NO) OFF Transistor Output Y88 (A1/A2) Transistor Output Y91 (Stop1) Tv = 0 to 30 seconds adjustable Residual Risk (En ISO/ISO12100-1) a) When it is necessary to modify the recommended circuit and if added/modified components are not properly integrated into the control circuit. b) When applicable standards of machine operation are not observed, or when the machine is not adjusted or maintained properly (adhere to a strict maintenance schedule). c) When the contacts of relays and contactors for connected with safety outputs are not forced guided (compliant with EN 50205). Enabling Switches The wiring diagrams on previous page have been tested under actual operating conditions. The HR1S-ATE safety relay module can be used in a safety circuit by connecting to safety equipment compliant to applicable standards. Consider residual risk in the following circumstances: Safety Control Light Curtains AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 405 Safety Control HR2S-301 HR2S-301P/HR2S-301N Safety Relay Modules Key features: HR2S-301 • Simple wiring procedure • Removable terminal block enables easy replacement • Terminal cover detects improper connection • Operation modes can be changes with a single action • Compact design enables installation in a narrow space • Safety Category 4, Performance Level e according to EN ISO 13849-1: 2008 • TÜV SÜD European and North American (NRTL) S te afety ste d on cti d du itore Pro on m XW Series E-Stops Overview Safety Relay HR2S-301 Functional Safety Part Numbers Auxiliary Contact 3NO 1NC Light Curtains Supply Voltage Part No. Positive 24V DC –15% to +10% HR2S-301P Negative 24V DC –15% to +10% HR2S-301N Specifications Applicable Standards Applicable Standards for Use Performance level (PL) Safety Category 1 Stop Category Operating Temperature Relative Humidity Altitude Insulation Resistance Dielectric Strength Shock Resistance Bump AS-Interface Safety at Work Input Vibration Resistance Degree of Protection Rated Voltage Power Consumption Overcurrent Protection Contact Resistance Turn-On Time 406 EN ISO 13849-1: 2008 EN 954-1: 1996 EN 50178: 1997 EN 55011/A2: 2007 EN 61000-6-2: 2005 IEC/EN 61496-1: 2006 UL508/R2005-07 CAN/CSA C22.2 No.14: 2005 EN 60204-1: 2006 e (EN ISO 13849-1) 3 or 4 (EN ISO 13849-1) 0 (IEC/EN 60204-1) –10 to +55°C (no freezing) 30 to 85% (no condensation) 0 to 2000m (operating) 100Ω minimum (500V DC megger, same measurement positions as dielectric strength) Between outside housing and internal circuit: 3,750V AC,1 minute Between outputs of different poles: 2,500V AC, 1 minute Between input and output terminals: 2,500V AC, 1 minute Between power supply and output terminals: 2,500V AC ,1 minute 300 m/s2, pulse width 11m sec, 3 shocks in each of 3 axes 100 m/s2, pulse width 16m sec, 1000 times in each of 3 axes 10 to 55 Hz, 1 octave/minute, 0.7 mmp-p in each of 3 axes, 20 sweeps, 5 to 55 Hz, 30 m/s2, for 2 hours in each of 3 axes Terminals: IP20 Housing: IP40 24V DC –15% +10% 2.2W (26.4V DC) Built-in, electronic (approx. 0.9A) 200 mΩ maximum 2 50 ms maximum 3 Minimum Applicable Load Response Time Overvoltage Category Pollution Degree Rated Insulation Voltage (output contact) Output Contact Ratings Safety Control Enabling Switches Interlock Switches Contact Configuration Safety Output Terminals 13-14 23-24 33-34 Rated Load 5 6 AC15 DC13 No. of Outputs Safety Circuit Rated Load 6 Terminals 41-42 AC15 DC13 No. of Outputs Mechanical Durability Electrical Durability Wire Size Weight (approx.) Safety Circuit 24V DC / 5 mA (Reference value) 20 ms maximum 3 4 III (IEC60664-1) 2 (IEC60664-1) 250V (IEC60664-1) 250V AC / 30V DC (resistive load) 7 Category 3 or lower: 5.0A maximum Category 4 or lower: 3.6A maximum 240V AC / 2A cosø=0.3 24V DC / 1A L/R=48 ms 3 (NO contact output) 250V AC / 30V DC (resistive load) Category 3 or lower: 5.0A maximum Category 4 or lower: 3.6A maximum 240V AC / 2A cosø=0.3 24V DC / 1A L/R=48 ms 1 (NC contact output) 5,000,000 operations minimum 100,000 operations minimum 0.2 mm2 to 1.5 mm2 (24 to 16 AWG) 200g 1. HR2S-301N is recommended for use in category 4 safety applications. The requirements of the safety category must be determined according to the safety equipment. We recommend that you consult a third party organization. Categories may change depending on the combination of the safety equipment. Categories may also change depending on the output contact ratings. 2. Measured using 5 or 6V DC, 1A voltage drop method. 3. When measured at the rated voltage (at 20°C), excluding contact bounce time. 4. The time from when the safety input turns OFF to when the safety output turns OFF. 5. Leave 5 mm of space between the sides of the module when more than 3A is continuously applied to the relay contact. 6. The module is not suitable for use with a load less than the minimum applicable load. Once a large load is applied, contacts may not operate with a small load. 7. The maximum current of the safety output contact is specified by the approved standard. Category 4 HR2S-301N, HR2S-301P + Type 4 OSSD’s 3.6A Category 3 HR2S-301P 5.0A To prevent the safety output contact from overcurrent, use a fuse. To satisfy Category 4, use a fuse with a maximum current of 3.6A. This fuse is not required if the short circuit current is less than 5A. www.IDEC.com Safety Control HR2S-301 Dimensions (mm) Overview 33 A2 SEAL 41 13 23 S33 S34 A1 SAFETY RELAY MODULE HR2S-301P AUTO RESET 41 13 23 33 XW Series E-Stops K1 K1 K2 111.2 POW MANU RESET K2 42 14 24 34 S11 S12 S21 S22 42 14 24 34 Terminal position (76.7) 22.5 Terminal position (95.7) 111 Part No. 1 6 33 A2 SAFETY RELAY MODULE HR2S-301P POW MANU RESET 5 K1 K1 K2 AUTO RESET 41 13 23 33 Part Names and Functions 1 CN1: Power supply input, start/off-check input 2 CN2: Safety input (dual channel) 3 S33 S34 A1 A2 CN3: Safety output contact 41 13 23 1 CN1 33 SAFETY RELAY MODULE HR2S-301P 8 4 CN4: Safety outputPOW contact K1 K2 5 6 MANU or MANU mode Switch: Select AUTO RESET AUTO RESET 6 POW: Power LED 7 K1: ON-LED for safety output 8 13 23 33 K1 41 output K2: ON-LED for safety K2 S11 42 Terminal 3 7 41 Y1 13 Y2 MANU RESET 5 42 14 24 34 S12 S21 S22 14 24 34 23 S12 CN2 41 K2 42 14 24 34 S12 S21 S22 14 24 34 S21 S22 33 41–42 CN3 CN4 2 2 4 4 Power supply 0V input S11 K1 S11 42 13 A2 S34 K2 AUTO RESET I/O Signals Power supply +24V DC input S33 23 33 S33 S34 HR2S-301P SAFETY RELAY MODULE POW K1 Markings A1 Start/off-check input Safety input 1 Common Safety input 2 Common Function Function For HR2S-301N, use a dry contact. When connecting TYPE 4 safety light curtain to HR2S-301P, use only S12 (S22). Rated load 250V AC / 30V DC, 1A (Resistive load) Safety output contact (NO) Rated load 250V AC / 30V DC (Note) (Resistive load) Category 3 or lower Category 4 HR2S-301P HR2S-301N, HR2S-301P + Type 4 OSSD’s 33–34 Note: 5.0A max. 3.6A max. Use a dry contact. Monitor contact for safety output (NC) 13–14 23–24 Notes Safety Control K2 42 14 24 34 S11 S12 S21 S22 42 14 24 34 Terminal Arrangement Enabling Switches 8 7 41 13 23 S33 S34 A1 Interlock Switches Terminal Arrangement Part Description 3 Light Curtains AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 407 Safety Control HR2S-301 Overview HR2S-301P Wiring Diagram Safety Category 4 Circuit Example (using a safety light curtain) *EDM function disabled SE4B Light Curtain (TYPE4, PNP Output) Emitter Safety category is achieved by the entire control system. Take the connected safety equipment and wiring into consideration. F1 (1) Receiver XW Series E-Stops Turn on DIP switch #3 on the receiver. F2 (1) 13 23 33 14 24 34 K1 K2 24V DC (Yellow) EDM (Blue) 0V (Brown) 24V DC (Blue) 0V N.C. (No Connect) (Brown) (White) 24V DC TEST/START External Device (Pink) 24V DC Interlock Switches A1 S11 S21 S22 2 S12 b ESC 1 (1) 13 23 33 41 14 24 34 42 S33 S34 a a b K2 (1) Use a 3.6A maximum fuse for output line protection. (Gray) OSSD1 OSSD2 S2 Relay Off Check ON Control Sub Circuit K1 K1 K2 K2 K1 Enabling Switches AUTO: Short MANU: Open Safety Control F3 (1) A2 Stop Category 0 to PLC 0V The SE4B light curtains are used in the above system. ESC: F1 to 3: K1 to 2: S2: S33-S34: External Start Condition Protective fuse for the output of safety relay module Safety Contactor Start Switch Feedback loop HR2S-301P Operation Chart Using OSSD outputs of a light curtain (EPSE) MANU mode AS-Interface Safety at Work Light Curtains AUTO mode 408 www.IDEC.com Safety Control HR2S-301 HR2S-301N Wiring Diagram Safety Category 4 (3) Circuit Example (using an emergency stop switch) 24V DC S11 S21 S2 S22 K2 1 2 b ESC (1) S33 S34 S12 a a b 13 Off check Relay ON Control Sub Circuit K1 K2 Overview S1 A1 Safety category is achieved by the entire control system. Take the connected safety equipment and wiring into consideration. 23 33 41 K1 K2 AUTO: Short MANU: Open A2 14 XW Series E-Stops K1 24 34 42 Stop Category 0 to PLC 0V F1 (1) F2 (1) F3 (1) 13 23 33 14 24 34 Interlock Switches ESC: External start condition F1 to 3: Protective fuse for the output of safety relay module S1: Emergency stop switch with 2NC contacts, safety switch (recommended) Start Switch S2: S33-S34: Feedback loop K1 K2 Enabling Switches (1) Use a 3.6A maximum fuse for output line protection. HR2S-301N Wiring Diagram Safety Category 4 (3) Circuit Example (using an emergency stop switch) Door Cover HS5E-DD4401-G Interlock Switch with Solenoid 24V DC 1 2 S5 S1 52 A2(+) 41 51 A1(-) 12 22 11 21 S2 21 2 1 11 22 12 S3 21 11 22 A1 S11 S21 K5 K6 S4 12 S22 ESC S33 S34 S12 K2 aa b F2 b Relay Off check K1 ON Control Sub Circuit K2 13 23 33 41 Operations of Interlock Switch with Solenoid (Stop) Machine stops → Unlocking enabling switch ON → Safety output OFF → Door cover released (Start) Door cover closed → Safety relay module start switch ON → Safety output ON → Machine starts Operations of Emergency Stop Switch (Stop) Press emergency stop switch → Safety output OFF → Machine stops (Start) Emergency stop switch reset → Safety relay module start switch ON → Safety output ON → Machine starts K1 K2 K1 14 24 34 42 AS-Interface Safety at Work AUTO: Short MANU: Open A2 External Start Condition Fuse 3.6A Safety Contactor (force guided) HS5E-DD4401-G Interlock Switch with Solenoid XW1E-BV402 Emergency Stop Switches Start Switch (HW series momentary) Unlocking Enabling Switch Limit Switch, etc. Light Curtains XW1E-BV402 Emergency Stop Switches F1 ESC: F1, F2: K5, 6: S1: S2, 3: S4: S5: S6: Safety Control 42 S6 HS9Z-A51 Actuator Safety category is achieved by the entire control system. Take the connected safety equipment and wiring into consideration. Read instructions before configuring circuits. External Output Circuit K5 K6 0V 800-262-IDEC (4332) • USA & Canada 409 Safety Control HR2S-301N Operation Chart Using an emergency stop switch AUTO mode Start Switch Power ON Operation Emergency Stop Switch Operation MANU mode Power ON Emergency stop switch S11-S12 Emergency stop switch S11-S12 Emergency stop switch S21-S22 Emergency stop switch S21-S22 Start Switch S33-S34 Start Switch S33-S34 Safety Output Contact 13-14, 23-24, 33-34 (NO) Safety Output Contact 13-14, 23-24, 33-34 (NO) Monitor Contact for Safety Output 41-42 (NC) Monitor Contact for Safety Output 41-42 (NC) ESC (External Start Condition) ESC (External Start Condition) AS-Interface Safety at Work Light Curtains Safety Control Enabling Switches Interlock Switches XW Series E-Stops Overview HR2S-301 410 www.IDEC.com Start Switch Operation Emergency Stop Switch Operation Safety Control HR2S-332N HR2S-332N-T075/T15/T30 Safety Relay Modules Overview Key features: S te afety ste d on cti d du itore Pro on m XW Series E-Stops • Simple wiring procedure • Removable terminal block enables easy replacement • Terminal cover detects improper connection • Operation modes can be changes with a single action • Compact design enables installation in a narrow space • Safety Category 4, Performance Level e according to EN ISO 13849-1: 2008 • TÜV SÜD European and North American (NRTL) Functional Safety Part Numbers Contact Configuration Time-delay Safety Output Input Auxiliary Contact Supply Voltage Part No. Interlock Switches Safety Output HR2S-332N-T075 3NO 3NO 2NC Negative 24V DC –15% to +10% HR2S-332N-T15 HR2S-332N-T30 Note: Time-delay duration can be set in 15 steps. 7.5 sec. (0.5, 1.0 … 7.0, 7.5); 15 sec. (1, 2 … 14, 15); 30 sec. (2, 4 … 28, 30) Specifcations Shock Resistance 300 m/s2, pulse width 11m sec, 3 times in each of 3 axes Bump 100 m/s2, pulse width 16m sec, 1000 times in each of 3 axes Vibration Resistance 10 to 55 Hz, 1 octave/minute, 0.7 mmp-p in each of 3 axes, 20 sweeps, 5 to 55 Hz, 30 m/s2, for 2 hours in each of 3 axes EN 60204-1: 2006 Degree of Protection Terminals: IP20 Housing: IP40 Performance level (PL) e (EN ISO13849-1) Rated Voltage 24V DC –15% to +10% Safety Category 4 (EN ISO13849-1) Power Consumption 4.6W (26.4V DC) Stop Category 0, 1 (IEC/EN 60204-1) 1 Overcurrent Protection Built-in, electronic (approx. 0.9A) Operating Temperature –10 to +55°C (no freezing) Contact Resistance Relative Humidity 30 to 85% (no condensation) 200 mW maximum (measured using 5 or 6V DC, 1A voltage drop method) Altitude 0 to 2000m (operating) Turn-On Time 50 ms maximum Insulation Resistance 100 MΩ minimum (500V DC megger, same measurement positions as dielectric strength) Dielectric Strength Between outside housing and internal circuit: 3,750V AC,1 minute Between outputs of different poles: 2,500V AC, 1 minute Between input and output terminals: 2,500V AC, 1 minute Between power supply and output terminals: 2,500V AC,1 minute Minimum Applicable Load 24V DC / 5 mA (reference value) Response Time 20 ms maximum Overvoltage Category III (IEC60664-1) Pollution Degree 2 (IEC60664-1) Rated Insulation Voltage (output contact) 250V (IEC60664-1) Safety Control Applicable Standards for Use Enabling Switches Applicable Standards EN ISO 13849-1: 2008 EN 954-1: 1996 EN 50178: 1997 EN 55011/A2: 2007 EN 61000-6-2: 2005 EN 61496-1: 2004 UL508/R2005-07 CAN/CSA C22.2 No.14: 2005 23 Light Curtains AS-Interface Safety at Work 1. Safety output contact: Stop Category 0 Time-delay output contact: Stop Category 1 2. When measured at the rated voltage (at 20°C), excluding contact bounce time. 3. The time from when the safety input turns OFF to when the safety output turns OFF. 800-262-IDEC (4332) • USA & Canada 411 Safety Control HR2S-332N Safety Circuit Terminals 41-42 AC15 240V AC / 2A cosø=0.3 DC13 24V DC / 1A L/R=48 ms No. of Outputs 3 (NO contact output) Rated Load 6 250V AC / 30V DC (resistive load) Category 3 or lower: 5.0A maximum Category 4 or lower: 3.6A maximum Safety Circuit Time-delay Output Contact Output Contact Ratings 250V AC / 30V DC (resistive load) 7 Category 3 or lower: 5.0A maximum Category 4 or lower: 3.6A maximum Rated Load 5 6 Terminals 13-14 23-24 33-34 Terminals 57-58 67-68 77-78 Terminals 45-46 250V AC / 30V DC (resistive load) 7 Category 3 or lower: 5.0A maximum Category 4 or lower: 3.6A maximum AC15 240V AC / 2A cosø=0.3 DC13 24V DC / 1A L/R=48 ms No. of Outputs 3 (NO contact output) Rated Load 6 250V AC / 30V DC (resistive load) Category 3 or lower: 5.0A maximum Category 4 or lower: 3.6A maximum DC13 24V DC / 1A L/R=48 ms Safety Circuit 1 (NC contact output) No. of Outputs AC15 240V AC / 2A cosø=0.3 DC13 24V DC / 1A L/R=48 ms 1 (NC contact output) Mechanical Durability 5,000,000 operations minimum Electrical Durability 100,000 operations minimum Wire Size 0.2 mm2 to 1.5 mm2 (24 to 16 AWG) Weight (approx.) 320g 5. Leave 5 mm of space between the sides of the module when more than 3A is continuously applied to the relay contact. 6. The module is not suitable for use with a load less than the minimum applicable load. Once a large load is applied, contacts may not operate with a small load. 7. The maximum current of the safety output contact is specified by the approved standard. Category 4: 3.6A Category 3: 5.0A To prevent the safety output contact from overcurrent, use a fuse. To satisfy Category 4, use a fuse with a maximum current of 3.6A. This fuse is not required if the short circuit current is less than 5A. 13 Y2 23 A1 33 A2 57 SAFETY K1 41 77 45 ERR. K3 K4 RELAY MODULE HR2S-332N-T075 POW K1 K2 MANU RESET 67 0.5 1 4 max. 7.5sec 0.5 1 4 max. 7.5sec AUTO RESET 13 23 33 42 14 24 34 K2 S11 S12 S21 S22 42 14 24 34 SEAL 41 S33 K3 57 67 77 45 K4 58 68 78 46 58 68 45.0 78 111.2 Enabling Switches Safety Circuit 240V AC / 2A cosø=0.3 Dimensions (mm) 46 Terminal position (76.7) Terminal position (95.7) 111 AS-Interface Safety at Work Light Curtains Safety Control Rated Load 5 6 AC15 No. of Outputs Interlock Switches XW Series E-Stops Overview Specifications, con’t 412 www.IDEC.com Safety Control Terminal Arrangement 11 41 9 8 13 S33 Y2 23 A1 33 A2 57 SAFETY MANU RESET K1 41 45 0.5 1 4 max. 7.5sec 0.5 42 14 24 34 K2 S11 S12 S21 S22 42 14 24 34 K4 58 12 4 13 AUTO RESET K3 15 1 max. 7.5sec 13 23 33 1 14 58 68 78 46 68 78 41 46 2 23 33 57 67 77 45 I/O Signals A1 Power supply +24V DC input A2 Power supply 0V input S33 input Y2 A1 (dual A2 CN2: Safety channel) 3 CN3: Safety output contact 1 4 CN4: Safety MANUoutput contact RESET 1 5 safety output contact CN5: Time-delayRESET S11 6 CN6: Time-delay safety output contact S12 SAFETY CN1 ERR. K3 K4 RELAY MODULE HR2S-332N-T075 POW K1 K2 0.5 max. 7.5sec 0.5 max. 7.5sec 4 S33 4 Y2 AUTO K1 41 13 23 33 K3 57 67 77 45 K4 58 68 78 46 CN2 Switch: Select AUTO or MANU mode 42 14 24 34 K2 S11 S12 S21 S22 42 14 24 34 POW: Power LED K1: ON-LED for safety output 10 K2: ON-LED for safety output 11 ERR: Error (timer) LED 12 Switches:  Time-delay. The same value should be set for both switches. Otherwise, an error occurs. 13 Characters:  Maximum time-delay duration is displayed. 0.75: 7.5 sec., 15: 15 sec., 30: 30 sec. 14 K3: ON-LED for safety output 15 K4: ON-LED for safety output 58 68 78 Start/off-check input S21 S22 46 41–42 CN3 CN4 13–14 23–24 33–34 Safety input 1 Common Safety input 2 Common Function Use a dry contact. Use a dry contact. Function Monitor contact for safety output (NC) Rated load 250V AC / 30V DC 1A (Resistive load) Safety output contact (NO) Rated load 250V AC / 30V DC (Note) (Resistive load) Rated load Time-delay safety output 250V AC / 30V DC 1A contact (NC) (Resistive load) 45–46 CN5 CN6 Remarks Interlock Switches 8 9 6 4 13 Markings 2 7 57 67 77 45 Terminals CN1: Power supply input, start/off-check input XW Series E-Stops 7 77 ERR. K3 K4 RELAY MODULE HR2S-332N-T075 POW K1 K2 67 Terminal Arrangement Part Names and Functions Overview Part No. 1 10 Part Description 5 3 HR2S-332N 57–58 Rated load Time-delay safety output 250V AC / 30V DC contact (NO) (Note) (Resistive load) 67–68 Enabling Switches 77–78 Note: 5.0A maximum Category 3 or lower 3.6A maximum Category 4 HR2S-332N-T075/T15/T30 Wiring Diagram Safety Category 4 Circuit Example (using an emergency stop switch) 24V DC S1 A1 S11 S21 S2 S12 S22 2 Y2 13 K3 K4 1 b S33 (1) a a b Relay Off check ON Control Sub Circuit K1 K1 K2 2 1 K3 Off-delay Timer Circuit ERR (1) 57 67 77 45 23 33 41 K1 K3 K2 K4 Safety Control K2 ESC K4 AUTO: Short MANU: Open 14 24 34 42 A2 Stop Category 0 58 68 78 46 Stop Category 1 to PLC Light Curtains 0V ESC: F1 to 6: S1: S2: S33-Y2: External Start Condition Protective fuse for the output of safety relay module Emergency stop switch with 2NC contacts, safety switch (recommended) Start Switch Feedback loop F1 (1) F2 (1) F3 (1) 13 23 33 14 24 34 K1 AS-Interface Safety at Work K2 (1) Use a 3.6A maximum fuse for output line protection. 800-262-IDEC (4332) • USA & Canada 413 Safety Control HR2S-332N Overview Safety Category 3 Circuit (using multiple emergency stop switches) Door Cover HS5E-DD4401-G Interlock Switch with Solenoid XW Series E-Stops Read instructions before configuring circuits. 24V DC 1 2 S5 S1 42 52 A2(+) 41 51 A1(-) 12 22 11 21 21 2 1 11 22 12 21 11 22 12 S6 HS9Z-A51 Actuator S2 S3 XW1E-BV402 Emergency Stop Switches A1 S11 S21 S22 Interlock Switches 2 F2 F4 F3 K5 K6 K7 K8 ESC S33 Y2 13 K3 K4 1 b F1 S4 S12 K2 Safety category is achieved by the entire control system. Take the connected safety equipment and wiring into consideration. a a b Off check Relay ON Control Sub Circuit K1 K4 2 33 41 K1 K3 K2 K4 57 67 77 45 58 68 78 46 ERR Off-delay Timer Circuit K2 1 K1 23 K3 AUTO: Short MANU: Open 14 A2 24 34 42 External Output Circuit K5 AS-Interface Safety at Work Light Curtains Safety Control Enabling Switches K6 K7 K8 0V ESC: External Start Condition F1 to F4: Fuse 3.6A K5 to 8: Safety Contactor S1: HS5E-DD4401-G Interlock Switch with Solenoid S2,3: XW1E-BV402 Emergency Stop Switches S4: Start Switch (HW series momentary) S5: Unlocking Enabling Switch S6: Limit Switch, etc. Operations of Interlock Switch with Solenoid (Stop) Machine stops Unlocking enabling switch ON Safety output OFF Door cover released (Start) Door cover closed Safety relay module start switch ON Safety output ON Machine starts Operations of Emergency Stop Switch (Stop) Press emergency stop switch Safety output OFF Machine stops (Start) Emergency stop switch reset Safety relay module start switch ON Safety output ON Machine starts HR2S-332N-T075/T15/T30 Operation Chart Using emergency stop switches AUTO mode Start Switch Power ON Operation MANU mode Emergency Stop Switch Operation Power ON Emergency Stop Switch S11-S12 Emergency Stop Switch S11-S12 Emergency Stop Switch S21-S22 Emergency Stop Switch S21-S22 Safety Output Contact 13-14, 23-24, 33-34 (NO) Safety Output Contact 13-14, 23-24, 33-34 (NO) Monitor Contact for Safety Output 41-42 (NC) Monitor Contact for Safety Output 41-42 (NC) ESC (External Start Condition) ESC (External Start Condition) Off-delay Safety Output 57-58, 67-68, 77-78 (NO) Off-delay Safety Output 57-58, 67-68, 77-78 (NO) 414 Emergency Stop Switch Operation Start Switch S33-Y2 Start Switch S33-Y2 Off-delay Monitor Contact 45-46 (NC) Start Switch Operation Tv=0...30s Adjustable Off-delay Monitor Contact 45-46 (NC) www.IDEC.com Tv=0...30s Adjustable Safety Control HR2S-332N Maintenance Parts Part Number Remarks Overview Item Terminal / Coding Key Terminal HR9Z-PMT1 Coding keys are used to prevent incorrect insertion of terminals. HR9Z-PMC1 Used to make sure that the terminals are fully inserted. Coding key Terminal Cover XW Series E-Stops Protective Tape HR9Z-PE1 Used to protect the AUTO/MANU switch on the front of the module. Interlock Switches Enabling Switches Safety Control Light Curtains AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 415 Safety Control FS1A XW Series E-Stops Overview FS1A Multi-function Safety Relay Key features: • No programming required. Configuration complete by turning on a logic switch • A safety circuit can be configured easily just by selecting a logic from eight preprogrammed logics • Mode selection, partial/entire stop can be achieved just by selecting a logic • One SafetyOne module can connect with various safety inputs such as emergency stop switches and light curtains • The status of safety I/Os and the SafetyOne errors can be monitored • Solenoid drive output is provided, eliminating the need for a PLC • IEC 61508 safety integrity level 3, ISO 13849-1 performance level e, and EN954-1 control category 4 compliant Interlock Switches Part Numbers Optional Parts No. of Logic Part Number 8 FS1A-CO1S 24 FS1A-C11S Enabling Switches Logic selection only! Simple DIP switch selection Product Part Number Input Connector FS9Z-CN01 Output Connector FS9Z-CN02 Connecting Tool FS9Z-SD01 Marked Cable Tie FS9Z-MT01 Used to lock the protective cover of the FS1A. DIN Rail BNDN1000 Aluminum, 1m 35mm wide End Clip BNL6 No tools required No programming or debugging Safety Control No program certification required Complies with key safety standards! International Standards Compliant Light Curtains ISO13849-1 PLe The SafetyOne satisfies: EN 954-1 IEC 61508 ISO 13849-1 Category 4 SIL3 Performance level e ISO IEC EN ANSI/RIA ANSI SEMI NFPA With 8 (FS1A-C01S) or 24 (FS1A-C11S) pre-programmed safety circuit logics in a compact housing, the FS1A SafetyOne safety controller allows you to build a safety circuit by just sliding a DIP switch. Because the programs are tested and approved for compliance with key safety standards, labor, cost, and time for safety system certification can be reduced greatly. AS-Interface Safety at Work Note: The eight logic programs of FS1A-C01S are not included in the 24 logic programs of FS1A-C11S. 416 www.IDEC.com Note Safety Control FS1A Large functionality in a compact housing! -ONE ALL-IN Replaces more than seven safety relay modules Overview Small & Compact Two-hand Control Emergency Stop Switch FS1A-C11S Logic 12A Interlock Switch Monitor Output Safety Output 1 Safety Output 2 Safety Outputs PLC Two-hand Control Monitor signals Mode selection Error signals 72 mm Emergency Stop Switch 114.5 mm Hazardous area Muting sensors FS1A-C11S Logic 103 Light Curtain Safety Output 1 Enabling Switch Safety Output 2 Selector Switch Object 113.5 mm Muting lamp Interlock Switches Muting function of light curtains Light curtains XW Series E-Stops Light Curtain (PNP) Interlock Switch Solenoid drive output Safety Input Enabling Switch Selector Switch Solenoid drive output Interlock Switch Enabling Switches Four safety output lines Emergency Stop Switch FS1A-C11S Logic 104 Safety Output 2 Safety Output 1-1 Safety Output 1-2 Safety Output 3 Safety Control Light Curtains AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 417 Safety Control Overview FS1A Output Lines Input Device 1 1 line Mode select necessary (Two dual safety outputs of the same operation) Mode select unnecessary Input Device 2 Input Device 3 Light curtain Using the muting function of FS1A 004 FS1A-C01S Not using the muting function of FS1A 003 FS1A-C01S 002 FS1A-C01S 001 FS1A-C01S XW Series E-Stops Other devices (Two dual safety outputs of different operations) Mode select necessary FS1A 006 FS1A-C01S NO/NC contact device 2 lines Logic No. Light curtain 005 FS1A-C01S Not using the muting function of FS1A 103 FS1A-C11S 13b FS1A-C11S 13C FS1A-C11S 13d FS1A-C11S 103 FS1A-C11S Interlock Switches 13A FS1A-C11S 13b FS1A-C11S Other devices 13C FS1A-C11S START 13d FS1A-C11S Mode select unnecessary 12A FS1A-C11S Two-hand control Using the muting function of FS1A 11A FS1A-C11S Light curtain Enabling Switches 11d FS1A-C11S Not using the muting function of FS1A C a t e g o r y 4 11C FS1A-C11S 102 FS1A-C11S 12C FS1A-C11S NO/NC contact device 11b FS1A-C11S 007 FS1A-C01S 008 FS1A-C01S 101 FS1A-C11S 11A FS1A-C11S Safety Control Other devices 11C FS1A-C11S 102 FS1A-C11S 12b FS1A-C11S 12C FS1A-C11S 4 lines (Four single safety outputs of different operations) Mode select necessary Light curtain Not using the muting function of FS1A 14d FS1A-C11S 108 FS1A-C11S Light Curtains 104 FS1A-C11S 14A FS1A-C11S 14b FS1A-C11S Other devices 14C FS1A-C11S 14b FS1A-C11S 108 FS1A-C11S AS-Interface Safety at Work Mode select unnecessary Light curtain Not using the muting function of FS1A 105 FS1A-C11S 106 FS1A-C11S 105 FS1A-C11S Other devices 106 FS1A-C11S 107 FS1A-C11S 418 www.IDEC.com C a t e g o r y 3 Safety Control FS1A Specifications Electric Characteristics Safety Circuit Logic selection Operating Temperature –10 to +55°C (no freezing) Operating Humidity 10 to 95% RH (no condensation) Storage Temperature –40 to +70°C (no freezing) Storage Humidity 10 to 95% RH (no condensation) Pollution Degree 2 (IEC/EN60664-1) Applicable Standards Free from corrosive gases Altitude Operation: 0 to 2000m, Transport: 0 to 3000m Vibration Resistance 5 to 8.4 Hz, amplitude 3.5 mm Vibration: 8.4 to 150 Hz Acceleration: 9.8 m/s2 (2 hours each on three mutually perpendicular axes) (IEC/EN60028-2-6) Bump: Acceleration 98 m/s2, 16 ms (1000 times each on three mutually perpendicular axes) (IEC/EN60028-2-29) Shock Resistance 147 m/s2, 11ms (3 shocks each on three mutually perpendicular axes (IEC/EN 60028-2-27) Connector Insertion/ Removal Durability 50 times maximum Configuration Switch Durability 100 operations maximum per pole Enter Button Durability 1000 operations maximum Housing Material Modified-polyphenyleneether (m-PPE) Weight (approx.) 330g 20.4 to 28.8V DC Maximum Power Consumption 48W (at the rated power voltage, when all I/Os are ON) (incl. output load) Allowable Momentary Power Interruption 10 ms minimum (at the rated power voltage) Response Time ON–OFF: 40 ms maximum 1 100 ms maximum 2 OFF–ON: 100 ms maximum 3 Start-up Time 4 6 sec maximum Dielectric Strength Between live part and FE terminal: 500V AC, 1 minute Between housing and FE terminal: 500V AC, 1 minute Insulation Resistance Between live part and FE terminal: 10 MΩ minimum (500V DC megger) Between housing and FE terminal: 10 MΩ minimum (500V DC megger) Impulse Noise Immunity (noise simulator) Power terminal: ±1 kV 50 ns, 1μs (direct connection) I/O terminal: ±2kV 50 ns, 1μs (coupling adapter) Inrush Current 25A maximum Ground Ground resistance of 100Ω maximum Effect of Incorrect Wiring Reverse polarity: No operation, no damage Improper voltage: Permanent damage may occur 1. The time to shut off safety outputs after inputs are turned off or input monitor error is detected (when off-delay timer is set to 0s) 2. Time to shut off safety outputs after an error (except input monitor error) or a configuration change of logic or timer is detected (not depending on the off-delay timer value) 3. Auto start—Time to turn on safety outputs after safe inputs are turned on Manual start—Time to turn on safety outputs after start inputs are turned on Control start—Time to turn on safety outputs after the start inputs are turned off-on-off (maintain ON for 0.1 to 5s) 4. Time to change to Run state after power supply is turned on. Safety Control IP20 (IEC/EN60529) Corrosion Immunity Allowable Voltage Range Enabling Switches Degree of Protection 24V DC Interlock Switches Rated Voltage XW Series E-Stops TÜV approval: IEC/EN 61000-6-2, IEC/EN 61000-6-4, IEC/EN 61496-1, IEC 61508 Part 1-7, IEC/EN 62061, ISO 13849-1, ISO 13851 (FS1AC11S), EN 954-1 UL: UL508, CSA C22.2 No. 142 Applicable standards: IEC/EN 60204-1, IEC/EN 61131-2, ISO 10218-1, ANSI/RIA R15.06, ANSI B11.19, SEMI S2-0706, NFPA79 EN 954-1, 13849-1, 62061, 61496-1, 60204-1, 61131-2, 61000-6-2, 61000-6-4 ANSI/RIA R15.06 ANSI B11.19 SEMI S2 NFPA 79 Overview Operating Environment Light Curtains AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 419 Safety Control FS1A Overview Examples FS1A-C11S Logic 105 Enabling Switches Interlock Switches XW Series E-Stops (PHUJHQF\ 6WRS6ZLWFK Safety Control Category 3 Logic 105 is used for safeguarding measures of machine tools and robots, which use safety equipment such as light curtains with dual solid state outputs. Safety outputs are single output. Five dual channel safety inputs can be connected. Safety output 4 has an off-delay timer. Wiring Example Logic Chart 6DIHW\2XWSXW /LJKW&XUWDLQ 313W\SH 6DIHW\2XWSXW 6DIHW\2XWSXW 6DIHW\2XWSXW +ROG 6HOIKROG IXQFWLRQ 7ULJJHU 6HOIKROGIXQFWLRQFLUFXLW 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; +ROG 6HOIKROG IXQFWLRQ 7ULJJHU 6HOIKROGIXQFWLRQFLUFXLW 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; +ROG 6HOIKROG IXQFWLRQ 7ULJJHU 6HOIKROGIXQFWLRQFLUFXLW 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; DIP Switch and LED Display FS1A-C11S Logic 13b 6HOIKROGIXQFWLRQFLUFXLW 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; /RJLF +ROG 6HOIKROG IXQFWLRQ 7ULJJHU 6HOIKROGIXQFWLRQFLUFXLW 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; 6WDUW,QSXW ; 0RQLWRU,QSXW 6WDUW,QSXW ; 0RQLWRU,QSXW ([WHUQDO'HYLFH0RQLWRU 7; ('0 ([WHUQDO 'HYLFH 0RQLWRU ([WHUQDO'HYLFH0RQLWRU 7; ('0 ([WHUQDO 'HYLFH 0RQLWRU ([WHUQDO'HYLFH0RQLWRU 7; ('0 ([WHUQDO 'HYLFH 0RQLWRU ([WHUQDO'HYLFH0RQLWRU 7; ('0 ([WHUQDO 'HYLFH 0RQLWRU +ROG 6HOIKROG IXQFWLRQ 7ULJJHU &RQWURO Safety Output  +ROG < 266' Safety Output  ('0 < +ROG 266' Safety Output  ('0 < +ROG 266' Safety Output  ('0 < +ROG 266' ZLWK 2IIGHOD\ ('0 &RQWURO 6WDUW Output Line: 2 2 dual safety outputs of different operations The logic constructing an OR circuit applicable for selection of active safety input devices Category 4 In machine tools and robots, a hazard source is isolated by a guard in automatic operation. In human-attended operation such as teaching and maintenance, the operator has to work inside a hazardous area. Logic 13b is used to configure a system in which teach or auto mode can be selected using a selector switch. Safety outputs are dual channel outputs. OR circuit can be configured in auto mode. Two dual channel direct opening input, one mode select input, one dual channel dependent input, and two dual channel safety inputs can be connected. Safety output 2 has an off-delay timer. Wiring Example Logic Chart /RJLFE (PHUJHQF\ 6WRS6ZLWFK (QDEOLQJ 6ZLWFK 6DIHW\2XWSXW 6HOHFWRU 6ZLWFK ,QWHUORFN 6ZLWFK Light Curtains Output Line: 4 4 single safety outputs of different operations Partial stop logic for apparatus with openings /LJKW&XUWDLQ 313W\SH 6DIHW\2XWSXW  6DIHW\,QSXW 7;7; 'XDO&KDQQHO 'LUHFW2SHQLQJ 6DIHW\,QSXW 7;7; 'XDO&KDQQHO 'HSHQGHQW 6DIHW\,QSXW 7;; 6DIHW\,QSXW 7;7; 0RGH6HOHFW AS-Interface Safety at Work 420 6HOIKROG IXQFWLRQ 7ULJJHU 7HDFK0RGH $XWR0RGH 'XDO&KDQQHO 'LUHFW2SHQLQJ 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; DIP Switch and LED Display 6HOIKROGIXQFWLRQ FLUFXLW +ROG 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; 6WDUW,QSXW ; 0RQLWRU,QSXW 6WDUW,QSXW ; 0RQLWRU,QSXW ([WHUQDO'HYLFH0RQLWRU 7; ('0 ([WHUQDO 'HYLFH 0RQLWRU ([WHUQDO'HYLFH0RQLWRU 7; ('0 ([WHUQDO 'HYLFH 0RQLWRU !  6HOIKROGIXQFWLRQ FLUFXLW +ROG 6HOIKROG IXQFWLRQ 7ULJJHU 6HOIKROGIXQFWLRQ FLUFXLW +ROG 6HOIKROG IXQFWLRQ 7ULJJHU !  6DIHW\2XWSXW < +ROG 266' ('0 6DIHW\2XWSXW +ROG 266' ZLWK 2IIGHOD\ ('0 &RQWURO &RQWURO 6WDUW www.IDEC.com < < < Safety Control Output Line: 2 2 dual safety outputs of different operations Partial stop logic applicable for selection of active safety input devices Category 4 Overview FS1A-C11S Logic 13C FS1A In machine tools and robots, a hazard source is isolated by a guard in automatic operation. In human-attended operation such as teaching and maintenance, the operator has to work inside a hazardous area. Logic 13C is used to configure a system in which teach or auto mode can be selected using a selector switch. Safety outputs are dual channel outputs. Three dual channel direct opening inputs, one mode select input, one dual channel dependent input, one dual channel safety input can be connected. Safety output 2 has an off-delay timer. Wiring Example (PHUJHQF\ 6WRS6ZLWFK Logic Chart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utput Line: 2 2 dual safety outputs of different operations Enabling Switches The logic for apparatus with a two-hand control device < +ROG Interlock Switches 6WDUW,QSXW ; 6DIHW\2XWSXW !  +ROG 6HOIKROG IXQFWLRQ 7ULJJHU 6DIHW\,QSXW 'XDO&KDQQHO6DIHW\ ;; DIP Switch and LED Display FS1A-C11S Logic 12A 6DIHW\,QSXW 7;7; XW Series E-Stops (QDEOLQJ 6ZLWFK 6HOIKROG IXQFWLRQFLUFXLW +ROG 6HOIKROG IXQFWLRQ 'XDO&KDQQHO 'LUHFW2SHQLQJ Category 4 Logic 12A is used for safeguarding measures of machine tools that use two-hand control. Safety outputs are dual channel outputs. Two dual channel direct opening inputs, one twohand control input (two safety inputs = one point), and two dual channel safety inputs can be connected. Safety output 2 has an off-delay timer. Wiring Example (PHUJHQF\ 6WRS 6ZLWFK Logic Chart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ight Curtains DIP Switch and LED Display 6DIHW\ 2XWSXW 'XDO&KDQQHO 'LUHFW2SHQLQJ Safety Control ,QWHUORFN 6ZLWFK 6DIHW\,QSXW 7;7; &RQWURO 6WDUW AS-Interface Safety at Work 800-262-IDEC (4332) • USA & Canada 421 Safety Control FS1A Overview FS1A-C01S Logic 004 Muting function logic for apparatus with openings Output Line: 1 2 dual safety outputs of the same operation Category 4 In Logic 004, muting functions are added to the dual solid state output of Logic 003. Dual direct-opening components such as emergency stop switches and interlock switches can be used at the same time. Muting Function Improves Productivity XW Series E-Stops With a muting function, the system stops when detecting a human and temporarily defeats the light curtain while work objects are being supplied. This improves the system’s productivity. Muting functions can be used easily by connecting a light curtain, muting sensor, and muting lamp to the SafetyOne (Note). In muting status, the OFF signals of corresponding safety solid state outputs are defeated. Wiring Example Logic Chart +D]DUGRXV$UHD 0XWLQJ6HQVRU /LJKW&XUWDLQ 1RWH 0DNHVXUHWKDWWKH LQWHUVHFWLRQRI RSWLFDOD[HVLVZLWKLQ WKHKD]DUGRXVDUHD Interlock Switches 2EMHFW /LJKW&XUWDLQ 313W\SH 0XWLQJ6HQVRU 313W\SH /LJKW&XUWDLQ 313W\SH 0XWLQJ6HQVRU 313W\SH DIP Switch and LED Display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ote: When installing light curtain and muting sensor, ensure safety by referring to IEC TS 62046 technical documents. Light Curtains AS-Interface Safety at Work 422 Note: Use light curtains, muting sensors, and muting lamps which meet the safety regulations or safety category of the country or regions where the products are used. Otherwise safety cannot be ensured, resulting in possible danger. 6DIHW\,QSXW Safety Control Enabling Switches (PHUJHQF\ 6WRS6ZLWFK 0XWLQJ/DPS 6DIHW\,QSXW ;; www.IDEC.com < < Safety Control Safety Input Specifications Drive Terminals FS1A Safety Output Specifications Output Type Source output (N channel MOSFET) Rated Output Voltage Power supply voltage Minimum Output Voltage Power supply voltage – 2.0V Rated Drive Voltage Power supply voltage Minimum Drive Voltage Power supply voltage – 2.0V Number of Safety Outputs 4 (Y0, Y1, Y2, Y3) Number of Drive Terminals 14 1 output 500 mA maximum Maximum Drive Current 20 mA per terminal (28.8V DC) (Note) Maximum Output Current Total 1A maximum Note: Drive terminals of safety inputs send safety confirmation signals (pulse signals) for the diagnosis of safety components and input circuits. Wiring and diagnosis function change depending on the selected logic. See user’s manual “Chapter 5 Logic.” Basic specifications remain the same. Leakage Current Allowable Capacitive Load 1 µF maximum Receive Terminals Cable Length 2 100m maximum (total length per output) 0.1 mA maximum L/R = 25 ms 24V DC Input ON Voltage 15.0 to 28.8V DC Input OFF Voltage Open or 0 to 5.0V DC Number of Inputs 14 Input Current 10 mA per terminal (at the rated power voltage) Input Signal Sink input (for PNP output), Type 1 (IEC61131-2) 9 ,QWHUQDO &LUFXLW /RJLF &LUFXLW Wire Cable Length (Note) 100m maximum (total wire length per input) Allowable Wire Resistance 300Ω maximum 2IIF\FOH $SSUR[PV Note: When wiring between the SafetyOne and a component is 30m or more, use shielded cable to ensure electromagnetic immunity. 21 2)) ‡5HFHLYH7HUPLQDO 2SHUDWLQJ5DQJH 2IIWLPH$SSUR[—V 9ROWDJH 9   NŸ Monitor Output Specifications 215DQJH ,QWHUQDO&LUFXLW ;Q     7UDQVLWLRQ 5DQJH  9² 2))5DQJH    Start Input Specifications Source output (N channel MOSFET) Rated Output Voltage Power supply voltage Minimum Output Voltage Power supply voltage – 2.0V Number of Safety Outputs 4 (Y0, Y1, Y2, Y3) Maximum Output Current 1 output 500 mA maximum Total 1A maximum Leakage Current 0.1 mA maximum Safety Control  &XUUHQW P$ Output Type Rated Input Voltage 24V DC Allowable Inductive Load 1 L/R = 25 ms Input ON Voltage 15.0 to 28.8V DC Allowable Capacitive Load 1 µF maximum Input OFF Voltage Open or 0V to 5.0V DC Cable Length 100m maximum (total length per output) Number of Start Inputs 2 (X16, X17) Input Current 5 mA per terminal (at the rated power voltage) Input Signal Sink input (PNP output), Type 1 (IEC61131-2) Cable Length (Note) 100m maximum (total wire length per input) Allowable Wire Resistance 300Ω maximum Note: When wiring between the SafetyOne and a component is 30m or more, use shielded cable to ensure electromagnetic immunity. ‡6WDUW,QSXW2SHUDWLRQ5DQJH 9 ,QWHUQDO &LUFXLW /RJLF &LUFXLW