Preview only show first 10 pages with watermark. For full document please download

- Sai Phasak 6000 Va Online Ph9265.

   EMBED


Share

Transcript

O n lin e U P S MODEL Galleon 1K (L) PHASE CAPACITY INPUT 1000 VA/800 W O N L I N E Harmonic Distortion 1500 VA/1200 W Single phase with ground 2000 VA/1600 W 3000 VA/2400 W LCD Display ALARM Battery Mode MANAGEMENT Smart RS-232 USB Optional SNMP 6000 VA/4800 W 10000 VA /8000 W 300 VAC ± 3% 290 VAC ± 5 % or 145 VAC ± 5 % 40 Hz ~ 70 Hz ≧ 0.99 @ Nominal Voltage (Full load) 290 VAC ± 3% 46 ~ 54 Hz or 56 ~ 64 Hz ≧ 0.99 @ 100% load 208/220/230/240 VAC or 110/115/120/127 VAC ± 3% 47~53 Hz or 57~63 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 3:1 ≦ 3 % THD (Linear Load) ≦ 4 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) ≦ 7 % THD (Non-linear Load) 208/220/230/240 VAC ± 1% 46 ~ 54 Hz or 56 ~ 64 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz 3:1 ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) Zero 4 ms (Typical) Zero Pure Sinewave 85% 88% 89% 88% 83% 12 V / 7 Ah 3 12 V / 9 Ah 3 12 V / 7 Ah 6 12 V / 9 Ah 6 4 hours recover to 90% capacity 1.0 A 41.0 VDC ± 1% 82.1 VDC ±1% 12 V / 7 Ah 12 V / 9 Ah 20 20 7 hours recover to 90% 9 hours recover to 90% capacity capacity 1.0 A 273.0 VDC ±1% Depending on applications 3 3 Depending on applications 6 6 18-20 4.0 A 273.0 VDC ±1% 8.0 A 41.0 VDC ± 1% 82.1 VDC ±1% UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions http://www.dns-system.es Sounding every 4 seconds Sounding every second Overload Noise Level Galleon 10K (L) 300 VAC ± 5 % or 150 VAC ± 5 % Low Battery Fault PHYSICAL Standard Dimension,DxWxH(mm) Model Net Weight (kgs) Dimension, Dx W x H(mm) Long-run Model Net Weight (kgs) ENVIRONMENT Humidity Galleon 6K (L) 186 VAC ± 3% @ 100% load 120 VAC ± 3% @ 50% load Battery Type Long-run Numbers Model Charging Current (max.) Charging Voltage INDICATORS Galleon 3K (L) 175 VAC ± 5% or 85 VAC ± 5% @ 100% load High Line Transfer Transfer AC Mode to Batt. Mode Time Inverter to Bypass Waveform (Batt. Mode) EFFICIENCY AC Mode Battery Mode BATTERY Battery Type Numbers Standard Typical Recharge Time Model Charging Current (max.) Charging Voltage Galleon 2K (L) 176 VAC ± 3% @ 100% load 110 VAC ± 3% @ 50% load Low Line Comeback High Line Comeback Frequency Range Power Factor OUTPUT Output Voltage AC Voltage Regulation (Batt. Mode) Frequency Range (Synchronized Range) Frequency Range (Batt. Mode) Current Crest Ratio Galleon 1.5K (L) 160 VAC ± 5% or 80 VAC ± 5% @ 100% load 110 VAC ± 5% or 50 VAC ± 5% @ 50% load Low Line Transfer Voltage Range UPS Sounding twice every second Continuously sounding 397 x 145 x 220 13 421 x 190 x 318 14 26 397 x 145 x 220 7 592 x 250 x 576 28 81 421 x 190 x 318 7 13 83 592 x 250 x 576 13 25 27 Less than 55dB @ 1 Meter Less than 58dB @ 1 Meter 20-90 % RH @ 0- 40°C (non-condensing) Less than 45dB@ 1 Meter Supports Windows2 2000/2003/XP/Vista/2008, Windows2 7, Linux, Unix, and MAC Power management from SNMP manager and web browser *Derate to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC. ** L means long-run model