Preview only show first 10 pages with watermark. For full document please download

Sample Park Outdoor Play Areasample Parkoutdoor

   EMBED


Share

Transcript

INSPECTION REPORT Sample Park - Sample Park Outdoor Play Area 01 July 2015 This report was generated by: Inspection was carried out by: Small World Inspections Sample Report Mel Campbell Annual Outdoor Playgrounds Created by Small World Inspections Page 1 of 21 Printed on 01/07/2015 Summary Sheet The following risks have been found: Item: Cableway - Spring stopper Hazard Control Measure Broken stopper Created by Small World Inspections Replace stopper Page 2 of 21 Printed on 01/07/2015 Report Detail Facility Name Site Sample Park Outdoor Play Area Overview Image Facility Type Sample Park Outdoor Playgrounds Report Annual Date 01/07/2015 Comments This inspection should be conducted on an annual basis beginning in July 2015 Seal Details Name: Mel Campbell Email Address: [email protected] Registration Number: 1061A Equipment: Balance Beam Rocker Image Details Comments Equipment Type: Rockers Manufacturer: Ledon Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Basket Swing Image Details Comments Equipment Type: Swings Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: Yes Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Created by Small World Inspections Page 3 of 21 Printed on 01/07/2015 Equipment: Bin Image Details Comments Equipment Type: Ancillary Manufacturer: Not applicable Installation Date: Compliant: Yes Inclusive: No Compliance: NONE Surface: Unknown Priority: 1 / Quality: 10 Equipment: Bouncing Disc Image Details Comments Equipment Type: General Manufacturer: Island Leisure Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Component: Base Top accordion Materials General Is the risk of the unit foreseeable to the child No Image Is the surface finish correct No Image Flammability Do any materials produce surface flash No Image Timber & Associated products Can water precipitation drain freely No Image Metals Are parts protected against atmospheric conditions and cathodic corrosion No Image Synthetics Is it possible to identify excessive wear of the gelcoat of GRP ( Glass -reinforced plastics ) No Image Dangerous substances Have any substances been used that could cause adverse health effects No Image Design & manufacture General Is the aimed age group under 36 months No Image Is the unit barriered from 600mm upwards Are there guardrails above 1m up to 2m Are there barriers from 2m to 3m Are grips between 16mm and 45mm diameter Created by Small World Inspections No Image Page 4 of 21 Printed on 01/07/2015 Areas to be grasped up to 60mm No Image Structural integrity Is the unit structurally sound Is the item safe? No Image Accessibility for adults Is the equipment designed to allow adults to gain access No Image Protection against falling Is the unit easily accessible No Image Are handrails on stairs, ramps and ladders between 600mm and 850mm when measured vertically No Image On steep elements up to 2m are the openings a maximum of 500mm No Image Finish of equipment Are sharp parts and materials radiused above 3mm No Image Do bolt heads protrude more 8mm No Image Moving parts Are there any crushing or shearing points Protect against entrapment Finger Are there any finger traps between 8mm - 25mm Are there any finger traps between 8mm - 25mm Head Are there any completely bound openings above 600mm between 230mm & 89mm No Image Head & Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground ( probe section A test template - up to 60 degrees) No Image Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground ( probe section B test template - max 45mm) No Image Foot Are there any foot entrapments above 30mm up to an angle of 45 degrees No Image Neck Are there angles that converge at less than 60 degrees No Image Whole body Are tunnels up to 1m in length with two openings above 400mm diameter No Image Are tunnels up to 2m in length with two openings above 500mm diameter No Image Are tunnels up to 2m in length above 750mm diameter No Image Head & Neck Is there a minimum clearance of 230mm above and below a suspension bridge to any rigid member No Image Clothes & hair Is there any where clothing can become whilst undergoing forced movement No Image Protection against injuries during movement and falling Created by Small World Inspections Page 5 of 21 Printed on 01/07/2015 Are there any obstacles in the falling space No Image Are there any obstacles in the free space No Image Is the fall height greater than 3m No Image Is the minimum extent of the falling space 1.5m No Image Does the impact area extend sufficiently for the free height of fall ie 2/3h + 0.5m No Image Are there fall heights above 600mm onto a non impact attenuating surface without forced movement No Image Is there a minimum of 1.5m falling space around the equipment up to a height of 1.5m No Image Are there any adjacent platforms with a free height of fall greater than 1m No Image Are openings in guardrails without a horizontal bar a maximum of 500 mm No Image Are openings in guardrails with a horizontal bar a maximum of 1.2m No Image Means of access Is the minimum depth of tread on the stairs 110mm No Image Is there 140mm of clear space for the foot on the stairs No Image Are the ramps inclined to a maximum of 38 degrees No Image Are steep elements inclined over 45 degrees No Image Is it possible for adults to gain access to the equipment, accessible openings no less than 500mm No Image Connections Can fixings be undone without special tools No Image Are all connections of a positive nature No Image Consumable components Are replacable components protected against unauthorised intervention No Image Is it possible to replace damaged components prone to wear No Image Ropes Are ropes between 1m & 2m fixed at one end a minimum of 600mm away from equipment No Image Are ropes between 2m & 4m fixed at one end a minimum of 1m away from equipment No Image Are ropes between 1m & 2m fixed at one end a minimum of 900mm away from swinging equipment No Image Are wire ropes made from galvanised or corrosion free resistant wire No Image Chains Where chain connections are made, is the opening greater than 12mm or less than 8.6mm No Image Do chains have a maximum opening of 8.6mm in any one direction No Image Foundations Are prefabricated footing a minimum of 200mm below surface level No Image Are on site fabricated footings a minimum of 400mm below surface level No Image Marking Is the equipment visibly marked No Image Surfacing Surface Type Rockers Created by Small World Inspections Page 6 of 21 Printed on 01/07/2015 Equipment: Cableway Image Details Comments Equipment Type: Cableways Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: No Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 8 / Quality: 3 Component: Spring stopper Safety Requirements Materials General Is the risk of the unit foreseeable to the child No Image Is the surface finish correct No Image Flammability Do any materials produce surface flash No Image Timber & Associated Products Can water precipitation drain freely No Image Metals Are parts protected against atmospheric conditions and cathodic corrosion No Image Synthetics Is it possible to identify excessive wear of the gelcoat of GRP (Glass-reinforced plastics) No Image Dangerous Substances Have any substances been used that could cause adverse health effects No Image Design & Manufacture General At what age group is the item aimed No Image Are grips between 16mm and 45mm diameter No Image Areas to be grasped up to 60mm No Image Structural Integrity Is the unit structurally sound No Image Is the item safe? Created by Small World Inspections Page 7 of 21 Printed on 01/07/2015 Hazard Broken stopper P7 Risk Level Control Residual Risk Maintaining Score (P×S) Measure Score (P×S) Control Potential Harm Probability 3 × Severity 3 Falls, cuts and bruises 9 Replace stopper Probability 1 × Severity 1 1 Regular routine inspections Q3 Accessibility for Adults Is the equipment designed to allow adults to gain access No Image Protection against falling Is the unit not accessible and over 36 months No Image Are handrails on stairs, ramps and ladders between 600mm and 850mm when measured vertically No Image Is the unit accessible and first step is below 400mm No Image On steep elements up to 2m are the openings a maximum of 500mm No Image Is the unit accessible and the platform is below 600mm No Image Finish of equipment Are the sharp parts and materials radiused above 3mm No Image Do bolt heads protrude more 8mm No Image Moving parts Are there any crushing or shearing points No Image Protection against entrapment Finger Are there any finger traps between 8mm - 25mm No Image Head Are there any completely bound openings above 600mm between 230mm & 89mm No Image Head & Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground (probe section A test template - up to 60 degrees) No Image Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground (probe section B test template - max 45mm) No Image Foot Are there any foot entrapments above 30mm up to an angle of 45 degrees No Image Neck Are there angles that converge at less than 60 degrees No Image Whole Body Are tunnels up to 1m in length with two openings above 400mm diameter No Image Are tunnels up to 2m in length with two openings above 500mm diameter No Image Are tunnels up to 2m in length above 750mm diameter No Image Head and Neck Is there a minimum clearance of 230mm above and below a suspension bridge to any rigid member No Image Clothes and Hair Is there anywhere clothing can become entangled whilst undergoing forced movement Created by Small World Inspections Page 8 of 21 No Image Printed on 01/07/2015 Protection against injuries during movement and falling Are there any obstacles in the falling space No Image Are there any obstacles in the free space No Image Is the fall height greater than 3m No Image Is the minimum extent of the falling space 1.5m No Image Does the impact area extend sufficiently for the free height of fall i.e. 2/3h + 0.5m No Image Are there fall heights above 600mm onto a non impact attenuating surface without forced movement No Image Is there a minimum of 1.5m falling space around the equipment up to a height of 1.5m No Image Are there any adjacent platforms with a free height of fall greater than 1m No Image Are openings in guardrails without a horizontal bar a maximum of 500mm No Image Are openings in guardrails with a horizontal bar a maximum of 1.2m No Image Means of Access Is the minimum depth of tread on the stairs 110mm No Image Is there 140mm of clear space for the foot on the stairs No Image Are the ramps inclined to a maximum of 38 degrees No Image Are steep elements inclined over 45 degrees No Image Is it possible for adults to gain access to the equipment, accessible openings no less than 500mm No Image Connections Can fixings be undone without special tools No Image Are all connections of a positive nature No Image Consumable components Are replaceable components protected against unauthorised intervention No Image Is it possible to replace damaged components prone to wear No Image Chains Where chain connections are made, is the opening greater than 12mm or less than 8.6mm No Image Do chains have a maximum opening of 8.6mm in any one direction No Image Foundations Are prefabricated footing a minimum of 200mm below surface level No Image Are on site fabricated footings a minimum of 400mm below surface level No Image Marking Is the equipment visibly marked No Image Surfacing What Type Additional requirements for cableways BS EN 1176-4 Stops Does the traveller stop without passing through 45 degrees No Image Traveller Is the traveller cladded to prevent access No Image Is there only one traveller No Image Suspension Assembly Created by Small World Inspections Page 9 of 21 Printed on 01/07/2015 Is the suspension element on a seating type cableway fully rigid? No Image Is it possible to form a noose with the suspension element No Image Is it possible to form a noose with the pulling device No Image Cableways in parallel Are 2 cableways arranged in parallel No Image Grips Can the user easily release their hold at all times No Image Is it possible to climb on the grip No Image Seats Can the user leave the seat freely at all times No Image When tested is the peak value of acceleration greater than 50g No Image When tested is the average surface compression greater than 90 N/cm2 No Image Speed Does the traveller exceed 7m/s No Image Free height of fall Is the free height of fall in the seating position greater than 2m No Image In the hanging position the free height of fall should not exceed 1.5m from the grip position > the distance to be taken minus 1.5m below the grip No Image Ground clearance Is there a clearance of 400mm below the seat when loaded with 130kg No Image Is there a clearance 1.5m minimum on a flexible type hanging runway at the starting position when loaded with 69.5kg No Image Is there a clearance 2m minimum on a flexible type hanging runway at the running position when loaded with 69.5kg No Image Is there a clearance 2m minimum on a rigid type hanging runway at the running position when loaded with 69.5kg No Image Cable height Is there 2.1m clearance minimum from the seat to the cable (1.8m if an enclosed traveller) No Image Is there 300mm clearance minimum from the grip to the cable No Image Falling Space and Impact Area Is there a minimum of 2m of falling space to either side of the cable No Image Is there a minimum of 2m of falling space beyond the grip or sear at 45 degrees No Image Component: Traveller Safety Requirements Materials General Is the risk of the unit foreseeable to the child No Image Is the surface finish correct No Image Flammability Do any materials produce surface flash No Image Timber & Associated Products Can water precipitation drain freely No Image Metals Created by Small World Inspections Page 10 of 21 Printed on 01/07/2015 Are parts protected against atmospheric conditions and cathodic corrosion No Image Synthetics Is it possible to identify excessive wear of the gelcoat of GRP (Glass-reinforced plastics) No Image Dangerous Substances Have any substances been used that could cause adverse health effects No Image Design & Manufacture General At what age group is the item aimed No Image Are grips between 16mm and 45mm diameter No Image Areas to be grasped up to 60mm No Image Structural Integrity Is the unit structurally sound Is the item safe? No Image Accessibility for Adults Is the equipment designed to allow adults to gain access No Image Protection against falling Is the unit not accessible and over 36 months No Image Are handrails on stairs, ramps and ladders between 600mm and 850mm when measured vertically No Image Is the unit accessible and first step is below 400mm No Image On steep elements up to 2m are the openings a maximum of 500mm No Image Is the unit accessible and the platform is below 600mm No Image Finish of equipment Are the sharp parts and materials radiused above 3mm No Image Do bolt heads protrude more 8mm No Image Moving parts Are there any crushing or shearing points No Image Protection against entrapment Finger Are there any finger traps between 8mm - 25mm No Image Head Are there any completely bound openings above 600mm between 230mm & 89mm No Image Head & Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground (probe section A test template - up to 60 degrees) No Image Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground (probe section B test template - max 45mm) No Image Foot Are there any foot entrapments above 30mm up to an angle of 45 degrees Created by Small World Inspections Page 11 of 21 No Image Printed on 01/07/2015 Neck Are there angles that converge at less than 60 degrees No Image Whole Body Are tunnels up to 1m in length with two openings above 400mm diameter No Image Are tunnels up to 2m in length with two openings above 500mm diameter No Image Are tunnels up to 2m in length above 750mm diameter No Image Head and Neck Is there a minimum clearance of 230mm above and below a suspension bridge to any rigid member No Image Clothes and Hair Is there anywhere clothing can become entangled whilst undergoing forced movement No Image Protection against injuries during movement and falling Are there any obstacles in the falling space No Image Are there any obstacles in the free space No Image Is the fall height greater than 3m No Image Is the minimum extent of the falling space 1.5m No Image Does the impact area extend sufficiently for the free height of fall i.e. 2/3h + 0.5m No Image Are there fall heights above 600mm onto a non impact attenuating surface without forced movement No Image Is there a minimum of 1.5m falling space around the equipment up to a height of 1.5m No Image Are there any adjacent platforms with a free height of fall greater than 1m No Image Are openings in guardrails without a horizontal bar a maximum of 500mm No Image Are openings in guardrails with a horizontal bar a maximum of 1.2m No Image Means of Access Is the minimum depth of tread on the stairs 110mm No Image Is there 140mm of clear space for the foot on the stairs No Image Are the ramps inclined to a maximum of 38 degrees No Image Are steep elements inclined over 45 degrees No Image Is it possible for adults to gain access to the equipment, accessible openings no less than 500mm No Image Connections Can fixings be undone without special tools No Image Are all connections of a positive nature No Image Consumable components Are replaceable components protected against unauthorised intervention No Image Is it possible to replace damaged components prone to wear No Image Chains Where chain connections are made, is the opening greater than 12mm or less than 8.6mm No Image Do chains have a maximum opening of 8.6mm in any one direction No Image Foundations Are prefabricated footing a minimum of 200mm below surface level No Image Are on site fabricated footings a minimum of 400mm below surface level No Image Marking Is the equipment visibly marked Created by Small World Inspections No Image Page 12 of 21 Printed on 01/07/2015 Is the equipment visibly marked Surfacing What Type Additional requirements for cableways BS EN 1176-4 Stops Does the traveller stop without passing through 45 degrees No Image Traveller Is the traveller cladded to prevent access No Image Is there only one traveller No Image Suspension Assembly Is the suspension element on a seating type cableway fully rigid? No Image Is it possible to form a noose with the suspension element No Image Is it possible to form a noose with the pulling device No Image Cableways in parallel Are 2 cableways arranged in parallel No Image Grips Can the user easily release their hold at all times No Image Is it possible to climb on the grip No Image Seats Can the user leave the seat freely at all times No Image When tested is the peak value of acceleration greater than 50g No Image When tested is the average surface compression greater than 90 N/cm2 No Image Speed Does the traveller exceed 7m/s No Image Free height of fall Is the free height of fall in the seating position greater than 2m No Image In the hanging position the free height of fall should not exceed 1.5m from the grip position > the distance to be taken minus 1.5m below the grip No Image Ground clearance Is there a clearance of 400mm below the seat when loaded with 130kg No Image Is there a clearance 1.5m minimum on a flexible type hanging runway at the starting position when loaded with 69.5kg No Image Is there a clearance 2m minimum on a flexible type hanging runway at the running position when loaded with 69.5kg No Image Is there a clearance 2m minimum on a rigid type hanging runway at the running position when loaded with 69.5kg No Image Cable height Is there 2.1m clearance minimum from the seat to the cable (1.8m if an enclosed traveller) No Image Is there 300mm clearance minimum from the grip to the cable No Image Falling Space and Impact Area Is there a minimum of 2m of falling space to either side of the cable No Image Is there a minimum of 2m of falling space beyond the grip or sear at 45 degrees No Image Created by Small World Inspections Page 13 of 21 Printed on 01/07/2015 Equipment: Cradle Swings Image Details Comments Equipment Type: Swings Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: Yes Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Dish Roundabout Image Details Comments Equipment Type: Carousels Manufacturer: Sutcliffe Play Limited Installation Date: Compliant: Yes Inclusive: Yes Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Fencing Image Details Comments Equipment Type: Ancillary Manufacturer: NK Fencing Installation Date: Compliant: Yes Inclusive: No Compliance: NONE Surface: Unknown Priority: 1 / Quality: 10 Equipment: Flat Swings Image Details Comments Equipment Type: Swings Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Component: Chains Top Accordion Materials Created by Small World Inspections Page 14 of 21 Printed on 01/07/2015 General Is the risk of the unit foreseeable to the child? No Image Is the surface finish correct? No Image Flammability Do any materials produce surface flash? No Image Timber & Associated Products Can water precipitation drain freely? No Image Metals Are parts protected against atmospheric conditions and cathodic corrosion? No Image Synthetics Is it possible to identify excessive wear of the gelcoat GRP? No Image Dangerous Substances Have any substances been used that could cause adverse health effects? No Image Design & Manufacture General Are grips between 16mm and 45mm in diameter? No Image Areas to be grasped up to 60mm No Image Structural Integrity Is the unit structurally sound? No Image Accessibility for adults Is the equipment designed to allow adults to gain access? No Image Protection against falling Is the unit easily accessible? No Image Finish of equipment Are sharp parts and materials radiused above 3mm? No Image Do bolt heads protrude more than 8mm? No Image Moving parts Are there any crushing or shearing points? No Image Protection against entrapment Finger Are there any finger traps between 8mm - 25mm No Image Head Are there any completely bound openings above 600mm between 230mm & 89mm? No Image Head & Neck Are there any partially bound openings or V shaped openings above 600mm in acute angles above ground? (probe section A test template - up to 60 degrees) No Image Neck Are there any partially bound or V shaped openings above 600mm in acute angles above ground? (probe section B test template max 45mm) No Image Foot Are there any foot entrapments above 30mm up to an angle of 45 degrees? No Image Neck Are there angles that converge at less than 60 degrees? Created by Small World Inspections Page 15 of 21 No Image Printed on 01/07/2015 Clothes and hair Is there any where clothing can become entangled whilst undergoing forced movement? No Image Protection against injuries during movement and falling Are there any obstacles in the falling space? No Image Are there any obstacles in the free space? No Image Is the fall height greater than 3m? No Image Connections Can fixings be undone without special tools? No Image Are all connections of a positive nature? No Image Consumable components Are replaceable components protected against unauthorised intervention? No Image Is it possible to replace damaged components prone to wear? Is the item safe? No Image Ropes Are ropes between 1m & 2m fixed at one end a minimum of 600mm away from equipment? No Image Are ropes between 2m & 4m fixed at one end a minimum of 1m away from equipment? No Image Are ropes between 1m & 2m fixed at one end a minimum of 900mm away from swinging equipment? No Image Are wire ropes made from galvanised or corrosion free resistant wire? No Image Chains Where chain connections are made, is the opening greater than 12mm or less than 8.6mm? No Image Do chains have a maximum opening of 8.6mm in any one direction? No Image Foundations Are prefabricated footings a minimum of 200mm below surface level? No Image Are on site fabricated footings a minimum of 400mm below surface level? No Image Heavy Suspended Beams Is there a ground clearance of at least 400mm? No Image Is there a profile radiused to at least 50mm? No Image Does the range of movement go beyond the support posts? No Image Does the range of movement exceed 100mm? No Image Is there a minimum of 230mm clearance to the support posts? No Image Surfacing What Type Additional requirements for swings BS EN 1176 - 2 Swing Type Seat Type Are the seats mixed? No Image Are there more than 2 seats? No Image When tested is the peak value of acceleration greater than 50g? No Image Created by Small World Inspections Page 16 of 21 Printed on 01/07/2015 When tested is the average surface compression greater than 90 N/cm2? No Image Is the seat to frame distance correct? D = 20% of suspension element + 200mm (Input measurements in mm) No Image Is the seat to seat distance correct? D = 20% of suspension element + 300mm (Input measurements in mm) No Image Is the splay of the top connections correct? D= seat width + 5% (Input measurements in mm) No Image Surfacing Requirements Is there a fenceline adjacent to the swing in an enclosure? No Image Is the swing frame attached to other equipment? No Image Is the surfacing compliant to the critical fall height? D = length of suispension member / 2 + height of swing seat No Image Are the suspension elements fully rigid? No Image Is the equipment visibly marked? No Image Surfacing Requirements Seat Type Are the seats mixed? No Image Are there more than 2 seats? No Image When tested is the peak value of acceleration greater than 50g? No Image When tested is the average surface compression greater than 90 N/cm2? No Image Is the seat to frame distance correct? D = 20% of suspension element + 200mm (Input measurements in mm) No Image Is the seat to seat distance correct? D = 20% of suspension element + 300mm (Input measurements in mm) No Image Is the splay of the top connections correct? D= seat width + 5% (Input measurements in mm) No Image Surfacing Requirements Is there a fenceline adjacent to the swing in an enclosure? No Image Is the swing frame attached to other equipment? No Image Is the surfacing compliant to the critical fall height? D = length of suispension member / 2 + height of swing No Image Are the suspension elements fully rigid? No Image Has the seat got a backrest? No Image Is the equipment visibly marked? No Image Surfacing Requirements Seat Type Is there more than 1 seat? No Image Is the surfacing compliant to the critical fall height? D = length of suispension member / 2 + height of swing No Image Is the bearing specifically designed for the swing? No Image Are the suspension elements fully rigid? No Image Are the supporting cables free to twist? No Image Is the equipment visibly marked? No Image Surfacing Requirements Surfacing Requirements Seat Type Are the seats mixed? Created by Small World Inspections No Image Page 17 of 21 Printed on 01/07/2015 When tested is the peak value of acceleration greater than 50g? No Image When tested is the average surface compression greater than 90 N/cm2? No Image Is the seat to frame distance correct? D = 20% of suspension element + 200mm (Input measurements in mm) No Image Is the seat to seat distance correct? D = 20% of suspension element + 300mm (Input measurements in mm) No Image Are the suspension elements fully rigid? No Image Is the splay of the top connections correct? D= seat width + 5% (Input measurements in mm) No Image Is there a minimum clearance of 400mm from the seat at 90 degrees from the horizontal to the central axis line? No Image Is the equipment visibly marked? No Image Surfacing requirements externally from the seat center line Surfacing Requirements Is the surfacing compliant to the critical fall height? D = length of suspension member / 2 + height of swing seat No Image Equipment: Gates Image Details Comments Equipment Type: Ancillary Manufacturer: NK Fencing Installation Date: Compliant: Yes Inclusive: No Compliance: NONE Surface: Unknown Priority: 1 / Quality: 10 Equipment: Rope Climber Image Details Comments Equipment Type: General Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Created by Small World Inspections Page 18 of 21 Printed on 01/07/2015 Equipment: Seats Image Details Comments Equipment Type: Ancillary Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: Yes Compliance: NONE Surface: Unknown Priority: 1 / Quality: 10 Equipment: See Saw Rocker Image Details Comments Equipment Type: Rockers Manufacturer: Fahr Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Signage Image Details Comments Equipment Type: General Manufacturer: Not Available Installation Date: Compliant: Yes Inclusive: Yes Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Surfacing Image Details Comments Equipment Type: Surfacing Manufacturer: Garden Escapes Installation Date: Compliant: Yes Inclusive: Yes Compliance: Surfacing BS EN 1177 Surface: Unknown Priority: 1 / Quality: 10 Created by Small World Inspections Page 19 of 21 Printed on 01/07/2015 Equipment: Toddler Multi Unit Image Details Comments Equipment Type: General Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Tower Multi Unit Image Details Comments Equipment Type: General Manufacturer: Playdale Playgrounds Limited Installation Date: Compliant: Yes Inclusive: No Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Equipment: Traditional Roundabout Image Details Comments Equipment Type: Carousels Manufacturer: Hags/SMP Limited Installation Date: Compliant: Yes Inclusive: Yes Compliance: Outdoor BS EN 1176 Surface: Unknown Priority: 1 / Quality: 10 Created by Small World Inspections Page 20 of 21 Printed on 01/07/2015 Outdoor Play Terms Created by Small World Inspections Page 21 of 21 Printed on 01/07/2015