Preview only show first 10 pages with watermark. For full document please download

Save Vtr 150/kl 500w White

   EMBED


Share

Transcript

SAVE VTR 150/K L 500W WHITE Document type: Product card Document date: 2016-01-14 Item no. 14991 Generated by: Systemair Online Catalogue Version: Filter F7-G3 Description • High efficient rotary heat exchanger • Energy efficient RadiCal-fans, with modern EC technology • Separate settings of supply and extract air flow • Start-up wizard for easy commissioning • Modern design with integrated cooker hood • Automatic change to summer operation (without heat recovery) • Demand control regulation • Low sound level • Modbus communication via RS-485 SAVE VTR 150/K has an integrated cooker hood and should be placed above the hob. The unit has been adapted to suit different kitchen environments, with a modern design. The unit is double skinned, fully insulated and with complete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters. Energy efficient fans with EC motors will reduce energy consumptions. With these, up to 50% less energy consumption can be achieved in comparison to AC solutions and with the noise behavior decreased by one-half. Modern technology gives low SFP factor (Specific Fan Power). SAVE VTR 150/K is adapted for ventilation of smaller houses and apartments with an area of 100 m² . The extract air from the cooker hood is being by-passed, hence the heat exchanger is not being exposed to extract air from the kitchen. The integrated kitchen hood has push buttons for the damper, forcing and lighting. The damper is opened during food preparation by pushing the button once. Pushing it another time will force the ventilation and a third time will close the ventilation damper in the cooker hood and the unit will go back to normal. Commissioning of the unit will be done from one or more CD control panels. A start-up wizard will make the commissioning easier, which can avoid that the unit is running at wrong conditions. Symbols and text in the display will indicate chosen settings; Supply air temperature and fan speed. Commissioning of airflow on supply and extract, will be done at start-up but can be set from the menu settings as well. Timer-function for automatic change between day and night operation is integrated. Setting of filter period is also available. Alarm signal will indicate possible malfunctions. The CD panel also has a user level for authorized installers and service personnel. The CD panel is connected to the unit by means of cable with quick connectors (modular plugs), at the top of the unit. SAVE VTR 150/K is provided with outlet for control of external hot water or cooling battery and inlets prepared for demand controlled ventilation from external sensors, f. inst. CO2, presence or humidity sensor (potential free contact). The unit is delivered with supply air filter G3 and extract air filter G3. Option for F7 supply air filter is available. Note: No continuous ventilation through the cooker hood Technical parameters Default group Voltage Frequency Phase Input power, fan motor(s) (for each motor) 230 V 50 Hz 1 2 x 86 ~ W Input power, electrical heating battery 0,5 kW Recommended fuse 10 A Enclosure class 24 IP Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 1 / 7 Weight 54 Filter, supply air G3 (Standard) Filter, extract air G3 (Standard) Airflow range 0..270 kg m³/h ErP ErP ready 2016, 2018 Energy class, basic unit B Energy class, basic unit option A Performance Diagrams Supply Extract Dimensions Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 2 / 7 *) Hatch **) Incl. bracket Supply air Exhaust air Outdoor air Extract air Wiring Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 3 / 7 Wiring diagram SAVE VTR_150_K_WD_207998_GB.pdf (287,53kB) Scheme F7 = Filter outdoor air VR = Rotary heat recovery unit EF = Extract fan G3 = Filter extract air G4 = Extract/Supply filter (only for VTC unit) ETS = Extract air temp. sensor SF = Supply fan EH = Electric heater SS = Supply air temp. sensor OT = Overheating thermostat ET = Emergency thermostat EHS = Exhaust air sensor OS = Outdoor air sensor BP = Bypass cooker hood BD = Bypass integrated cooker hood DB = Bypass damper Accessories Electric accessories CD Control panel 3 (208175) CE/CD-diverting plug 4pin (37367) CO2RT-R-D Transmitter (6993) CEC Cable w/plug 12m (24782) CEC Cable w/plug 6m (24783) CO2 Sensor Wireless (25126) Presence detector/IR24-P (6995) Push button, impulse (9693) HR1 Room Humidistat IP21 (5150) F-T120 Timer frame (5137) PSS48 Transformer 24V (204385) PSS20 Transformer 24V (202692) Humidity Sensor Wireless (25127) Input Module Wireless (25128) TG-A130 Surface sensor 0-30°C (5159) T 120 Timer (5165) TG-K360 Duct sensor 0-60°C (4846) U-EK plastic housing AP1R IP54 (30198) RVAZ4 24A Actuator 0-10V (9862) SmartDial (25129) RS485 Gateway Wireless (25130) Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 4 / 7 Accessories BFVTR 150/K F7 Supply Air (207953) BFVTR 150/K G3 Extract Air (207950) Connectduct Ø 125/1,0 M/F (2556) BFVTR 150/K G3 Supply Air (207951) CVVX 125 Combi grille, black (26421) CVVX 125 Combi grille, white (26422) ZTR 15-0,4 valve 3-way (9670) VBC 125-2 Water heating batt (5457) VBC 125-3 Water heating batt (9839) LDC 125-600 Silencer (5190) LDC 125-900 Silencer (5191) CWK 125-3-2,5 Duct cooler,circ (30021) FK 125 Fast clamp (1608) Duct Cover White VTR 150/K (19566) ZTV 15-0,4 2-way valve (9829) ZTV 15-0,6 2-way valve (6571) ZTR 15-0,6 valve 3-way (6573) GEO heat exchanger box (312513) Duct Cover S.Steel VTR 150/K (19567) RDR-80/15-50m³/h (37293) CAD drawing VTR 150K L.dxf (278,44kB) Documentation SAVE_VTR150_Installation_and_service_207996_CE_GB_A004.pdf (2,17MB) SAVE_VTR150_User_manual_207997_GB_A002.pdf (1,06MB) Modbus for Residential units_D24810_User_manual (A005).pdf (263,77kB) CD panel Instruction for wall mounting 206858 GB_SE.pdf (221,37kB) Energy class label Energy class, basic unit Unit with local demand control Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 5 / 7 Eco design Basic unit Trade name Product name Systemair SAVE VTR 150/K L 500W White ErP compliance 2018 SEC Average -32,5 kWh/ (m².a) SEC Cold -72,9 kWh/ (m².a) SEC Warm -9,4 kWh/ (m².a) SEC Class B Unit category RVU Unit type BVU Drive Intergated VSD Heat recovery type Regenerative Temperature ratio 75 qv max P max Sound power 0,0748 169 44 qv ref 0,0524 Ps ref 50 % m³/s W dB(A) m³/s Pa SPI 1,55 kW/m³/s CTRL 0,85 - MISC 1,1 - x-value 2 - External Leakage 5 % Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 6 / 7 Internal Leakage Type of product 5 % RAHU/AARE AEC average 389 kWh AEC cold 389 kWh AEC warm 389 kWh AHS Average 4224 kWh/a AHS Cold 8262 kWh/a AHS Warm 1910 kWh/a Units with local demand control Trade name Product name Systemair SAVE VTR 150/K L 500W White ErP compliance 2018 SEC Average -38,1 kWh/ (m².a) SEC Cold -80,1 kWh/ (m².a) SEC Warm -14,1 kWh/ (m².a) SEC Class A Unit category RVU Unit type BVU Drive Intergated VSD Heat recovery type Regenerative Temperature ratio 75 qv max P max Sound power 0,0748 169 44 qv ref 0,0524 Ps ref 50 % m³/s W dB(A) m³/s Pa SPI 1,55 kW/m³/s CTRL 0,65 - MISC 1,1 - x-value 2 - External Leakage 5 % Internal Leakage 5 % Type of product RAHU/AARE AEC average 228 kWh AEC cold 228 kWh AEC warm 228 kWh AHS Average 4383 kWh/a AHS Cold 8574 kWh/a AHS Warm 1982 kWh/a Specification text Name: SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE SAVE VTR 150/K L 500W WHITE | Item no.: 14991 14991 14991 | Version: Filter F7­G3 Filter F7­G3 Document type: Product card Product card Product card | Document date: 2016­01­14 2016­01­14 2016­01­14 | Generated by: Online catalogue Online catalogue 7 / 7