Sbt_clc02

   EMBED


Share

Transcript

Chilled ceiling and radiator CLC02 • Heating with radiator and cooling with chilled ceiling • Modulating control of heating and cooling valve • Dew point monitoring Plant diagram 7013 YC D3 YH N1 R1 D1 D2 D3 YH YC Room temperature controller Room unit with temp. sensor Window switch Occupancy sensor Dew point sensor Heating valve Cooling valve T R1 D1 D2 N1 LON Sequence diagram 70284 Y [%] Y TR SpH SpC H C YH YC Output signal Room temperature Effective heating setpoint Effective cooling setpoint Heating sequence Cooling sequence Heating valve Cooling valve Siemens Building Technologies Building Automation H C 100 YH YC SpH SpC 0 DESIGO RXC Applications Library Application CLC02 TR [°C] CA2A3815E02 / 09.2001 1/4 Functions For details refer to the “CLC” description of functions at the beginning of this section (CA2A3815E00). Application CLC02 includes the following functions: Function Brief description Proportional heating and cooling – PID control sequence – Two proportional control sequences, heating and cooling – Control of thermic valve actuators (AC 24 V, PWM) – Valve exercising feature See CA2A3815E00 6.1 6.4 6.6 Dew point sensor – Dew point sensor to prevent condensation formation 6.5 Operating modes 2, 3 Setpoint reset – Comfort, Stand-by, Economy and Building protection – Change of operating mode via /Auto switch on room unit, occupancy sensor, window contact or central command – Locally via room unit or via central command Temperature measurement – Via room unit or passive temperature sensor General functions – – – – – Room units – Versions available with temperature sensor, setpoint adjuster, /Auto switch and LCD display CLC02 can be used in conjunction with RXC10.1 and RXC20.1 Compatible controllers CA2A3815E02 / 09.2001 2/4 5 Occupancy sensor Window switch Master/slave operation Boost, night cooling etc. DESIGO RXC Applications Library Application CLC02 4 2.2, 7.4 2.2, 7.4 7.2 7.6, 7.7 8 Siemens Building Technologies Building Automation Connection diagrams 00229 1)2) L N AC 24 V 2) YH YC 3) N1 G D1 G0 GND YC1 GND Y1 D2 G D1 D2 D3 1)2) LON 2) CLA 3) Y2 1) 2) Q23 Q24 D2 RXC10.1 CLB LON D3 1) D1 1) 2) YH B1 3) YC 3) R1 T 4 3 2 1 1 2 B M QAX... N1 CLB CLA CLB CLA G CP+ Y2 CP– G 19 20 21 17 18 Q14 Y1 13 14 15 16 Q13 D2 D1 9 L 8 M 7 B1 6 N 5 N 4 GND 80106 3 25 26 RXC20.1 AC 230 V N L List of equipment Ref. N1 Description Room temperature controller Type RXC10.1 RXC20.1 3830 3834 R1 Room unit QAX30.1 QAX31.1 QAX32.1 QAX34.1 QAX39.1 1741 1741 1641 1645 1646 Wireless room unit Reciever QAX90.1, 91.1 RXZ90.1 1643 1644 Room temperature sensor QAA24 1721 B1 1) Type of operation (N/O or N/C) can be selected 2) Either an occupancy sensor or a window contact may be connected (but not both) 3) Note the maximum load for outputs Y1/Y2: max. 9.5 VA (see RXC20.1, data sheet 3834) Siemens Building Technologies Building Automation 1) 2) D1 Window contact D2 Occupancy sensor 1) 2) D3 Dew point sensor 1) Please provide AC24V supply! Thermic heating valve, 2-position (PWM) control 3) YH YC Thermic cooling valve, 2-position (PWM) control 3) DESIGO RXC Applications Library Application CLC02 Data sheet . . . Third-party device Third-party device QFX21 1551 STE71.11 STA71 4874 4877 . . . T3W..., T4W... STE72 STE71.1 STA71 4829 4873 4874 4877 . . . – – CA2A3815E02 / 09.2001 3/4 Configuration The parameters available with application CLC02 are shown below. They are set in the RXT10.1 commissioning and service tool in the Device, Configure, Settings menu option. Menu Parameter Values/range Basic setting Temperature setpoints Comfort heating 10 ... 35 °C 21 °C Comfort cooling 10 ... 35 °C 24 °C Stand-by heating 10 ... 35 °C 19 °C Stand-by cooling 10 ... 35 °C 28 °C Economy heating 10 ... 35 °C 15 °C Economy cooling 10 ... 35 °C 35 °C Building protection heating 10 ... 40 °C 12 °C Building protection cooling 10 ... 40 °C 40 °C Valve type – STE71.1 STE71.1 Sequences Room unit Cooling – STE72 Heating STE71.1 STE71.1 Sensor correction – 3 ... 3 K 0K Setpoint reset range ± 0 ... 10 K ±3K Display of heating/cooling symbol General functions Temperature unit °C or °F °C Temperature display in normal mode None / room temp. / setpoint room temp. Temperature display in setpoint shift mode Absolute or relative Absolute Occupancy override time 0 ... 90 min 30 min Receiver period 0 ... 105 min. 60 min. Send interval (heartbeat) Occupancy sensor 0 ... 105 min. 45 min. Digital input 1 or 2 No occ. sensor Type of operation: Room occupied: Contact open or closed Closed Switch-off delay 0 ... 90 min 5 min Switch-on delay 0 ... 90 min 5 min Digital input 1 or 2 No window switch Window closed: Contact open or closed Closed Window switch Type of operation: Dew point sensor Type of operation: Master/slave LONMARK bindings Enabled Digital input 1 or 2 No dew point sensor Condensation: Contact open or closed Closed Master or Slave Master Heating demand signal Enabled Cooling demand signal Enabled Morning boost Enabled Night cooling Enabled Service LED Enabled Reset shift Disabled See the sections headed “LonMark network variables” and “LonMark binding templates” Ordering Room controllers may be ordered either with the application described above or with the appropriate basic application. Please state the quantity, DESIGO RXC device name, type code and application. Example 1 15 Notes • The controllers will be delivered with the basic settings shown above. • Minimum order quantity: 10 controllers Example 2 2 Notes • The controllers will be delivered with the basic application • The application can be loaded into the controllers by means of the RXT10.1 tool • Minimum order quantity: 1 controller CA2A3815E02 / 09.2001 4/4 DESIGO RXC Applications Library Application CLC02 RXC20.1 individual room controllers with application CLC02 RXC20.1/CLC02 RXC20.1 room controllers . . . . . . . . RXC20.1 / 00020 Siemens Building Technologies Building Automation . . .